{"product_id":"esbe-ara655-2-point-actuator-for-vrg-valves-230v-60-seconds","title":"ESBE ARA655 2-Point Actuator 230V 60s 6Nm | 12120900","description":"\u003c!-- SEO Product Name: ESBE ARA655 2-Point Actuator 230V 60s 6Nm | 12120900 | IP41 --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#222222; line-height:1.6; font-family:Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThe \u003cstrong\u003eESBE ARA655\u003c\/strong\u003e is a compact \u003cstrong\u003e2-point (on\/off) rotary actuator\u003c\/strong\u003e for motorising ESBE rotary valves \u003cstrong\u003eDN15 to DN50\u003c\/strong\u003e. With a \u003cstrong\u003e60 second running time per 90°\u003c\/strong\u003e, \u003cstrong\u003eup to 6 Nm of torque\u003c\/strong\u003e and \u003cstrong\u003e230 V AC supply\u003c\/strong\u003e, it is the standard partner for \u003cstrong\u003eESBE VRG230 and VRG330 diverting valves\u003c\/strong\u003e in heat pump, cylinder and zone change-over applications.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThe actuator is \u003cstrong\u003esupplied complete with the ARA803 adaptor kit\u003c\/strong\u003e for ESBE VRG, VRB and VRH valves and a \u003cstrong\u003e1.5 m connection cable already attached\u003c\/strong\u003e. A \u003cstrong\u003epull-and-turn knob\u003c\/strong\u003e gives instant \u003cstrong\u003emanual operation\u003c\/strong\u003e, and the same actuator will also accept a \u003cstrong\u003e3-point signal\u003c\/strong\u003e where required. Fit the optional \u003cstrong\u003eARA801 auxiliary switch kit\u003c\/strong\u003e for a position-proving contact. ESBE's special \u003cstrong\u003evalve-to-actuator interface\u003c\/strong\u003e gives the assembled unit \u003cstrong\u003eunique stability and precise regulation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:10px; margin:20px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; text-align:center; background:#f1f8f7; border-top:4px solid #008377CF; padding:12px 8px; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-size:22px; font-weight:bold; color:#008377CF;\"\u003e60 s\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; color:#444444;\"\u003eRunning time per 90°\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; text-align:center; background:#f1f8f7; border-top:4px solid #008377CF; padding:12px 8px; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-size:22px; font-weight:bold; color:#008377CF;\"\u003e6 Nm\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; color:#444444;\"\u003eMax. torque (5 Nm nominal at 20°C)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; text-align:center; background:#f1f8f7; border-top:4px solid #008377CF; padding:12px 8px; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-size:22px; font-weight:bold; color:#008377CF;\"\u003e230 V AC\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; color:#444444;\"\u003eSupply, 50 Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; text-align:center; background:#f1f8f7; border-top:4px solid #008377CF; padding:12px 8px; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-size:22px; font-weight:bold; color:#008377CF;\"\u003eIP41\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; color:#444444;\"\u003eEnclosure, protection class II\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; text-align:center; background:#f1f8f7; border-top:4px solid #008377CF; padding:12px 8px; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-size:22px; font-weight:bold; color:#008377CF;\"\u003e1.5 m\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; color:#444444;\"\u003ePre-fitted connection cable\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; text-align:center; background:#f1f8f7; border-top:4px solid #008377CF; padding:12px 8px; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-size:22px; font-weight:bold; color:#008377CF;\"\u003e90°\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; color:#444444;\"\u003eOperating range\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:6px solid #b3261e; background:#fdecea; padding:12px 16px; margin:14px 0; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#b3261e; margin-bottom:4px;\"\u003eElectrical safety\u003c\/div\u003e\n\u003cdiv\u003eIsolate the mains supply before removing any actuator cover or working on the wiring. Installation, wiring and commissioning must be carried out by a competent person in accordance with \u003cstrong\u003eBS 7671\u003c\/strong\u003e and the installation instruction supplied with the product. Provide a suitable means of isolation in the supply to the actuator.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:6px solid #a06a00; background:#fff6e0; padding:12px 16px; margin:14px 0; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#a06a00; margin-bottom:4px;\"\u003eCompatibility and selection\u003c\/div\u003e\n\u003cdiv\u003eDesigned for ESBE rotary valves \u003cstrong\u003eDN15 to DN50\u003c\/strong\u003e. For diverting duty the actuator only uses the \u003cstrong\u003eend positions\u003c\/strong\u003e of its travel. The \u003cstrong\u003e60 second\u003c\/strong\u003e version gives a \u003cstrong\u003eslower, more gradual change-over\u003c\/strong\u003e than the 30 second ARA645. Check any \u003cstrong\u003eswitching-time requirement\u003c\/strong\u003e set by the heat pump or cylinder manufacturer before choosing the running time.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:6px solid #008377CF; background:#f1f8f7; padding:12px 16px; margin:14px 0; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:4px;\"\u003eReady to fit\u003c\/div\u003e\n\u003cdiv\u003eThe \u003cstrong\u003eARA803 adaptor kit (16000500)\u003c\/strong\u003e for ESBE valve series VRG, VRB, VRH, G, MG, F, BIV, T, TM, H and HG is \u003cstrong\u003eincluded\u003c\/strong\u003e. Adaptor kits for \u003cstrong\u003eMeibes, Watts, Honeywell Centra Corona, Lovato, PAW and WITA\u003c\/strong\u003e valves are available separately from ESBE.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size:20px; color:#008377CF; margin:30px 0 12px 0; padding-bottom:6px; border-bottom:2px solid #008377CF; font-weight:bold;\"\u003eKey features\u003c\/h3\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:12px; margin:14px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #cfe5e2; border-top:4px solid #008377CF; border-radius:4px; padding:12px 14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003e\u003cstrong\u003e2-point on\/off control\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eSingle pole single throw (SPST) control signal, \u003cstrong\u003erecommended for diverting applications\u003c\/strong\u003e such as heat pump to cylinder change-over.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #cfe5e2; border-top:4px solid #008377CF; border-radius:4px; padding:12px 14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003e\u003cstrong\u003eAlso accepts 3-point\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eAll ARA600 2-point actuators can \u003cstrong\u003ealso be used with a 3-point control signal\u003c\/strong\u003e when a controller requires it.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #cfe5e2; border-top:4px solid #008377CF; border-radius:4px; padding:12px 14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003e\u003cstrong\u003eQuick manual override\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eA \u003cstrong\u003epull-and-turn knob\u003c\/strong\u003e on the front lets you move the valve by hand for commissioning, filling and fault-finding.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #cfe5e2; border-top:4px solid #008377CF; border-radius:4px; padding:12px 14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003e\u003cstrong\u003eAdaptor kit included\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eSupplied with the \u003cstrong\u003eARA803 adaptor kit\u003c\/strong\u003e, so it mounts directly on ESBE \u003cstrong\u003eVRG, VRB and VRH\u003c\/strong\u003e rotary valves.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #cfe5e2; border-top:4px solid #008377CF; border-radius:4px; padding:12px 14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003e\u003cstrong\u003eOptional auxiliary switch\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eAdd the \u003cstrong\u003eARA801 kit\u003c\/strong\u003e (6(3) A, 230 V AC) to confirm valve position. The switch is set \u003cstrong\u003etool-free\u003c\/strong\u003e under the knob.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #cfe5e2; border-top:4px solid #008377CF; border-radius:4px; padding:12px 14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003e\u003cstrong\u003eCompact and quiet\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eReliable, \u003cstrong\u003equiet operation\u003c\/strong\u003e in a compact housing with \u003cstrong\u003edouble-insulated (class II)\u003c\/strong\u003e construction and \u003cstrong\u003e-5°C to +55°C\u003c\/strong\u003e ambient rating.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size:20px; color:#008377CF; margin:30px 0 12px 0; padding-bottom:6px; border-bottom:2px solid #008377CF; font-weight:bold;\"\u003eTechnical specification\u003c\/h3\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:4px; margin:14px 0; overflow:hidden;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:8px 14px;\"\u003eProduct identification\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eBrand\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eESBE\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eModel\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eARA655 2-point actuator, 230 V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eManufacturer part number\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e12120900\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eSeries\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eARA600 2-point (SPST)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eSupersedes\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eESBE article 12002700\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:4px; margin:14px 0; overflow:hidden;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:8px 14px;\"\u003eElectrical\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eSupply voltage\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e230 V AC ±10%, 50 Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003ePower consumption\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e5 VA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eControl signal\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e2-point SPST (3-point also possible)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eProtection class\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eII\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eEnclosure rating\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eIP41\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eRated impulse voltage\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e4 kV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003ePollution degree\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e2\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eSupplementary fuse\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eT6.3A, 250 V (IEC 60127)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eBranch fuse\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e16 A, characteristic C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:4px; margin:14px 0; overflow:hidden;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:8px 14px;\"\u003ePerformance\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eRunning time (90°)\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e60 seconds\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eOperating range\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e90°\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eTorque, nominal (20°C ±5°C)\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e5 Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eTorque, maximum\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e6 Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eManual operation\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003ePull-and-turn knob\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:4px; margin:14px 0; overflow:hidden;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:8px 14px;\"\u003eMechanical and environment\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eConnection cable\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e1.5 m, attached\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eWeight\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e0.4 kg\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eAmbient temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e-5°C to +55°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eMounting height\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eC + 77 mm (C per valve datasheet)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:4px; margin:14px 0; overflow:hidden;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:8px 14px;\"\u003eCompatible valves\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eDirect fit (ARA803 supplied)\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eESBE VRG100, VRG200, VRG300, VRH100, VRB100; also G, MG, F, BIV, T, TM, H and HG series\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eOptional accessory\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eARA801 auxiliary switch kit (16200700)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:4px; margin:14px 0; overflow:hidden;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:8px 14px;\"\u003eCompliance\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eDirectives\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eLVD 2014\/35\/EU, EMC 2014\/30\/EU, RoHS 2011\/65\/EU\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eUK\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eUKCA Declaration of Conformity published by ESBE for the ARA600 2-point range\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size:20px; color:#008377CF; margin:30px 0 12px 0; padding-bottom:6px; border-bottom:2px solid #008377CF; font-weight:bold;\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin:8px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; cursor:pointer; font-weight:bold;\"\u003eWhat does 2-point control mean?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px;\"\u003eA 2-point (on\/off) actuator drives the valve to \u003cstrong\u003eone end position when powered\u003c\/strong\u003e and to the \u003cstrong\u003eother end position when the signal changes\u003c\/strong\u003e. It is ideal for \u003cstrong\u003ediverting and change-over valves\u003c\/strong\u003e such as ESBE VRG230 and VRG330.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin:8px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; cursor:pointer; font-weight:bold;\"\u003eWhich valves does it fit?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px;\"\u003eIt mounts on ESBE rotary valves \u003cstrong\u003eDN15 to DN50\u003c\/strong\u003e: \u003cstrong\u003eVRG100, VRG200, VRG300, VRH100, VRB100\u003c\/strong\u003e and others via the \u003cstrong\u003eARA803 adaptor kit supplied in the box\u003c\/strong\u003e.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin:8px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; cursor:pointer; font-weight:bold;\"\u003eHow does the ARA655 differ from the ARA645?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px;\"\u003eBoth are 230 V, 6 Nm, 2-point actuators. The \u003cstrong\u003eARA655 runs in 60 seconds\u003c\/strong\u003e per 90°, the \u003cstrong\u003eARA645 in 30 seconds\u003c\/strong\u003e. Choose the running time that suits the application and the equipment manufacturer's guidance.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin:8px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; cursor:pointer; font-weight:bold;\"\u003eCan I add an auxiliary switch?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px;\"\u003eYes. Fit the \u003cstrong\u003eARA801 auxiliary switch kit\u003c\/strong\u003e. The switch point is set by lifting off the knob, with \u003cstrong\u003eno tools needed\u003c\/strong\u003e.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin:8px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; cursor:pointer; font-weight:bold;\"\u003eCan I operate the valve by hand?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px;\"\u003eYes. \u003cstrong\u003ePull and turn the knob\u003c\/strong\u003e on the front of the actuator to move the valve manually.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin:8px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; cursor:pointer; font-weight:bold;\"\u003eIs the cable included?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px;\"\u003eYes. A \u003cstrong\u003e1.5 m connection cable is attached\u003c\/strong\u003e at the factory.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"ESBE","offers":[{"title":"Default Title","offer_id":67580893725062,"sku":"ARA655","price":215.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/esbe-actuator-30s-60s.jpg?v=1791356731","url":"https:\/\/qualityheating.co.uk\/products\/esbe-ara655-2-point-actuator-for-vrg-valves-230v-60-seconds","provider":"AIZO Quality Heating","version":"1.0","type":"link"}