{"product_id":"eph-controls-22mm-3-port-mid-position-valve-b322mid-7-1-kvs","title":"EPH Controls 22mm 3 Port Mid Position Valve | B322MID | 7.1 Kvs","description":"\u003c!-- SEO Product Name: EPH Controls 22mm 3 Port Mid Position Valve | B322MID | 7.1 Kvs --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#222222; line-height:1.65; font-family:inherit;\"\u003e\n\u003cp style=\"margin:0 0 16px; font-size:16px;\"\u003eThe \u003cstrong style=\"color:#008377CF;\"\u003eEPH Controls B322MID\u003c\/strong\u003e is a \u003cstrong style=\"color:#008377CF;\"\u003e22mm compression 3 port motorised mid-position valve\u003c\/strong\u003e for domestic heating systems that have both a \u003cstrong style=\"color:#008377CF;\"\u003ehot water cylinder and a central heating circuit\u003c\/strong\u003e. In mid-position operation, a call for heating alone opens \u003cstrong style=\"color:#008377CF;\"\u003ePort A\u003c\/strong\u003e, a call for hot water alone opens \u003cstrong style=\"color:#008377CF;\"\u003ePort B\u003c\/strong\u003e, and a call for both brings the valve to the \u003cstrong style=\"color:#008377CF;\"\u003emid position with Port A and Port B open\u003c\/strong\u003e, delivering a \u003cstrong style=\"color:#008377CF;\"\u003e7.1 Kvs flow rate\u003c\/strong\u003e through the valve.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 16px; font-size:16px;\"\u003eThe \u003cstrong style=\"color:#008377CF;\"\u003e230V actuator\u003c\/strong\u003e uses a \u003cstrong style=\"color:#008377CF;\"\u003espring return\u003c\/strong\u003e that closes Port A and opens Port B if mains power is lost, and a \u003cstrong style=\"color:#008377CF;\"\u003emanual override lever\u003c\/strong\u003e allows the system to be filled, flushed or drained. The valve is rated for a \u003cstrong style=\"color:#008377CF;\"\u003emaximum operating pressure of 21 bar\u003c\/strong\u003e and a \u003cstrong style=\"color:#008377CF;\"\u003epermanent operating temperature of 2…88°C\u003c\/strong\u003e. It is supplied with a \u003cstrong style=\"color:#008377CF;\"\u003e1.2 metre, 5 core cable\u003c\/strong\u003e, has a \u003cstrong style=\"color:#008377CF;\"\u003eremovable actuator head\u003c\/strong\u003e and can also be wired as a \u003cstrong style=\"color:#008377CF;\"\u003ediverter valve\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:10px; margin:24px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; background:#E6F3F2; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-size:22px; font-weight:bold; line-height:1.2;\"\u003e22mm\u003c\/div\u003e\n\u003cdiv style=\"color:#555555; font-size:13px; margin-top:6px;\"\u003eCompression connections\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; background:#E6F3F2; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-size:22px; font-weight:bold; line-height:1.2;\"\u003e7.1\u003c\/div\u003e\n\u003cdiv style=\"color:#555555; font-size:13px; margin-top:6px;\"\u003eKvs flow rate\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; background:#E6F3F2; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-size:22px; font-weight:bold; line-height:1.2;\"\u003e88°C\u003c\/div\u003e\n\u003cdiv style=\"color:#555555; font-size:13px; margin-top:6px;\"\u003eMax. fluid temperature\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; background:#E6F3F2; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-size:22px; font-weight:bold; line-height:1.2;\"\u003e21 bar\u003c\/div\u003e\n\u003cdiv style=\"color:#555555; font-size:13px; margin-top:6px;\"\u003eMax. operating pressure\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; background:#E6F3F2; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-size:22px; font-weight:bold; line-height:1.2;\"\u003e5W\u003c\/div\u003e\n\u003cdiv style=\"color:#555555; font-size:13px; margin-top:6px;\"\u003eActuator power\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; background:#E6F3F2; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-size:22px; font-weight:bold; line-height:1.2;\"\u003e1.2m\u003c\/div\u003e\n\u003cdiv style=\"color:#555555; font-size:13px; margin-top:6px;\"\u003e5 core cable supplied\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E6F3F2; border-left:6px solid #008377CF; border-radius:4px; padding:14px 18px; margin:18px 0;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-weight:bold; font-size:16px; margin-bottom:4px;\"\u003eValve position by wiring\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003e\n\u003cstrong style=\"color:#008377CF;\"\u003eNo supply or 230V to orange or grey:\u003c\/strong\u003e hot water, Port B open. \u003cstrong style=\"color:#008377CF;\"\u003e230V to white:\u003c\/strong\u003e mid position, Port A and Port B open. \u003cstrong style=\"color:#008377CF;\"\u003e230V to grey and white together:\u003c\/strong\u003e central heating, Port A open. Without power the valve \u003cstrong style=\"color:#008377CF;\"\u003espring returns\u003c\/strong\u003e to Port A closed and Port B open.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFF6E0; border-left:6px solid #B26A00; border-radius:4px; padding:14px 18px; margin:18px 0;\"\u003e\n\u003cdiv style=\"color:#B26A00; font-weight:bold; font-size:16px; margin-bottom:4px;\"\u003eFitting notes\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eFit the valve so the \u003cstrong style=\"color:#008377CF;\"\u003eactuator head is not below the horizontal level of the pipework\u003c\/strong\u003e, with flow in the direction of the arrow, from the \u003cstrong style=\"color:#008377CF;\"\u003ecentre port to Port A or Port B\u003c\/strong\u003e. The \u003cstrong style=\"color:#008377CF;\"\u003eopen vent and cold feed must not be isolated\u003c\/strong\u003e. Use the valve body only for grip when tightening the compression nuts, and \u003cstrong style=\"color:#008377CF;\"\u003edo not overtighten\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FDECEA; border-left:6px solid #B3261E; border-radius:4px; padding:14px 18px; margin:18px 0;\"\u003e\n\u003cdiv style=\"color:#B3261E; font-weight:bold; font-size:16px; margin-bottom:4px;\"\u003eInstallation safety\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eInstallation must be carried out by a \u003cstrong style=\"color:#008377CF;\"\u003equalified person in accordance with wiring regulations\u003c\/strong\u003e. \u003cstrong style=\"color:#008377CF;\"\u003eFuse the system to no more than 3A.\u003c\/strong\u003e Use \u003cstrong style=\"color:#008377CF;\"\u003e230V only\u003c\/strong\u003e, an \u003cstrong style=\"color:#008377CF;\"\u003eearth connection is required\u003c\/strong\u003e, and \u003cstrong style=\"color:#008377CF;\"\u003enever insulate or cover the actuator\u003c\/strong\u003e because it must not exceed its \u003cstrong style=\"color:#008377CF;\"\u003e50°C maximum ambient temperature\u003c\/strong\u003e. This is \u003cstrong style=\"color:#008377CF;\"\u003enot a fail-safe, no-fail or safety product\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color:#008377CF; font-size:22px; font-weight:bold; margin:36px 0 16px; padding-bottom:8px; border-bottom:3px solid #008377CF;\"\u003eKey Features\u003c\/h3\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:14px; margin:20px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; min-width:240px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:6px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-weight:bold; font-size:17px; margin-bottom:6px;\"\u003eMid-position operation\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eServes \u003cstrong style=\"color:#008377CF;\"\u003ecentral heating and hot water circuits together\u003c\/strong\u003e, with \u003cstrong style=\"color:#008377CF;\"\u003ePort A and Port B open\u003c\/strong\u003e when both call for heat.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; min-width:240px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:6px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-weight:bold; font-size:17px; margin-bottom:6px;\"\u003eHigh flow rate\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003e\n\u003cstrong style=\"color:#008377CF;\"\u003e7.1 Kvs\u003c\/strong\u003e through the 22mm body, with maximum close-off pressures of \u003cstrong style=\"color:#008377CF;\"\u003e1.6 bar (Port A)\u003c\/strong\u003e and \u003cstrong style=\"color:#008377CF;\"\u003e1.2 bar (Port B)\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; min-width:240px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:6px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-weight:bold; font-size:17px; margin-bottom:6px;\"\u003eSpring return actuator\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003e\n\u003cstrong style=\"color:#008377CF;\"\u003e230V, 5W\u003c\/strong\u003e impedance-protected motor; on power loss the valve \u003cstrong style=\"color:#008377CF;\"\u003ereturns to Port A closed, Port B open\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; min-width:240px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:6px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-weight:bold; font-size:17px; margin-bottom:6px;\"\u003eManual override\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eA \u003cstrong style=\"color:#008377CF;\"\u003emanual lever\u003c\/strong\u003e opens the valve for \u003cstrong style=\"color:#008377CF;\"\u003efilling, flushing or draining\u003c\/strong\u003e; return it to \u003cstrong style=\"color:#008377CF;\"\u003eAuto\u003c\/strong\u003e for normal operation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; min-width:240px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:6px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-weight:bold; font-size:17px; margin-bottom:6px;\"\u003eReady to wire\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eSupplied with a \u003cstrong style=\"color:#008377CF;\"\u003e1.2 metre, 5 core cable\u003c\/strong\u003e (blue, orange, grey, white, yellow\/green) and \u003cstrong style=\"color:#008377CF;\"\u003enuts and olives\u003c\/strong\u003e for the compression joints.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; min-width:240px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:6px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-weight:bold; font-size:17px; margin-bottom:6px;\"\u003eDiverter wiring option\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eWith \u003cstrong style=\"color:#008377CF;\"\u003egrey and white cores\u003c\/strong\u003e linked, the valve works as a \u003cstrong style=\"color:#008377CF;\"\u003ediverter\u003c\/strong\u003e: 0V opens Port B (hot water), 230V opens Port A (heating).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color:#008377CF; font-size:22px; font-weight:bold; margin:36px 0 16px; padding-bottom:8px; border-bottom:3px solid #008377CF;\"\u003eTechnical Specification\u003c\/h3\u003e\n\u003cdiv style=\"margin:20px 0; border:1px solid #008377CF; border-radius:6px; overflow:hidden;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; font-size:16px; padding:10px 16px;\"\u003eValve\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F3F9F8; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eProduct code\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003eB322MID\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eEAN \/ GTIN\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003e5391515072541\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F3F9F8; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eConnection\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003e22mm compression\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003ePorts\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003e3 (centre port to Port A or Port B)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F3F9F8; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eFunction\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003eMid position; can be wired as a diverter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eKvs (m³\/h)\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003e7.1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F3F9F8; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eMax. close-off pressure\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003e1.6 bar (Port A); 1.2 bar (Port B)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eMax. static \/ operating pressure\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003e21 bar\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F3F9F8; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003ePermanent operating temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003e2…88°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; font-size:16px; padding:10px 16px;\"\u003eActuator\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F3F9F8; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eMotor supply voltage\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003e230V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003ePower consumption\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003e5W\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F3F9F8; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eMax. ambient temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003e50°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eProtection rating\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003eIP20\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F3F9F8; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eMovement\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003eRotary, multi position; spring return\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eClassification\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003eType 1.AA in accordance with EN 60730\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F3F9F8; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eRated impulse voltage\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003e2500V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eLead\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003e1.2 metre, 5 core cable; earth connection required\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F3F9F8; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eMax. supply fuse\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003e3A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eSpindle\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003e4mm flat; actuator head removable from the valve body\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; font-size:16px; padding:10px 16px;\"\u003eWiring Colours (Mid Position)\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F3F9F8; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eBlue\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003eNeutral supply\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eOrange\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003eHot water ON from cylinder thermostat or programmer; also connect to boiler and pump live\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F3F9F8; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eGrey\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003eHot water OFF from cylinder thermostat or programmer\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eWhite\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003eCentral heating ON from room thermostat or programmer\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F3F9F8; padding:9px 16px; border-bottom:1px solid #D5E8E6; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:bold; color:#008377CF;\"\u003eYellow \/ green\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px;\"\u003eEarth\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color:#008377CF; font-size:22px; font-weight:bold; margin:36px 0 16px; padding-bottom:8px; border-bottom:3px solid #008377CF;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv style=\"margin:20px 0;\"\u003e\n\u003cdetails style=\"margin:0 0 10px; border:1px solid #008377CF; border-radius:6px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:12px 16px; cursor:pointer;\"\u003eHow does a mid-position valve work?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:15px;\"\u003eA call for \u003cstrong style=\"color:#008377CF;\"\u003eheating only\u003c\/strong\u003e opens \u003cstrong style=\"color:#008377CF;\"\u003ePort A\u003c\/strong\u003e; a call for \u003cstrong style=\"color:#008377CF;\"\u003ehot water only\u003c\/strong\u003e opens \u003cstrong style=\"color:#008377CF;\"\u003ePort B\u003c\/strong\u003e; \u003cstrong style=\"color:#008377CF;\"\u003eboth calls together\u003c\/strong\u003e bring the valve to the \u003cstrong style=\"color:#008377CF;\"\u003emid position\u003c\/strong\u003e with Port A and Port B open. The boiler and pump live is taken from the \u003cstrong style=\"color:#008377CF;\"\u003eorange\u003c\/strong\u003e core.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"margin:0 0 10px; border:1px solid #008377CF; border-radius:6px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:12px 16px; cursor:pointer;\"\u003eWhat happens if the power fails?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:15px;\"\u003eThe actuator \u003cstrong style=\"color:#008377CF;\"\u003espring returns\u003c\/strong\u003e to \u003cstrong style=\"color:#008377CF;\"\u003ePort A closed and Port B open\u003c\/strong\u003e. EPH states this is \u003cstrong style=\"color:#008377CF;\"\u003enot a fail-safe, no-fail or safety product\u003c\/strong\u003e, so it should not be relied on for safety functions.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"margin:0 0 10px; border:1px solid #008377CF; border-radius:6px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:12px 16px; cursor:pointer;\"\u003eHow should I position the valve?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:15px;\"\u003eMount it so the \u003cstrong style=\"color:#008377CF;\"\u003eactuator head is not below the horizontal level of the pipework\u003c\/strong\u003e, with flow in the direction of the arrow from the centre port to Port A or Port B. Do not isolate the open vent or cold feed.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"margin:0 0 10px; border:1px solid #008377CF; border-radius:6px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:12px 16px; cursor:pointer;\"\u003eHow do I fill, flush or drain the system?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:15px;\"\u003eMove the \u003cstrong style=\"color:#008377CF;\"\u003emanual override lever\u003c\/strong\u003e to the raised manual position to hold the valve open, flush and drain as required, then refill and add inhibitor if needed. \u003cstrong style=\"color:#008377CF;\"\u003eReturn the lever to Auto\u003c\/strong\u003e before commissioning.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"margin:0 0 10px; border:1px solid #008377CF; border-radius:6px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:12px 16px; cursor:pointer;\"\u003eCan I use it as a diverter valve?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:15px;\"\u003eYes. Connect the \u003cstrong style=\"color:#008377CF;\"\u003egrey and white cores together\u003c\/strong\u003e to the heating switch: \u003cstrong style=\"color:#008377CF;\"\u003e0V opens Port B\u003c\/strong\u003e (hot water, normally open) and \u003cstrong style=\"color:#008377CF;\"\u003e230V opens Port A\u003c\/strong\u003e (heating). Terminate the \u003cstrong style=\"color:#008377CF;\"\u003eorange core safe\u003c\/strong\u003e, as it carries 230V when grey and white are also live.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"margin:0 0 10px; border:1px solid #008377CF; border-radius:6px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:12px 16px; cursor:pointer;\"\u003eIs the actuator replaceable?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:15px;\"\u003eThe actuator can be \u003cstrong style=\"color:#008377CF;\"\u003eremoved from the valve body\u003c\/strong\u003e by setting the lever to manual, loosening the side screw and the two base screws. It refits to the \u003cstrong style=\"color:#008377CF;\"\u003e4mm flat spindle\u003c\/strong\u003e, so the valve body can stay in the pipework.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"EPH Controls","offers":[{"title":"Default Title","offer_id":67573083832710,"sku":"B322MID","price":87.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/EPH-B322MID-22mm-3-Port-Motorised-Mid-Position-Valve.jpg?v=1791217034","url":"https:\/\/qualityheating.co.uk\/products\/eph-controls-22mm-3-port-mid-position-valve-b322mid-7-1-kvs","provider":"AIZO Quality Heating","version":"1.0","type":"link"}