{"product_id":"enphase-3-phase-q-cable-male-field-wireable-connector","title":"Enphase 3-Phase Q Cable Male Field Wireable Connector","description":"\u003c!-- SEO Product Name: Enphase 3-Phase Q Cable Male Field Wireable Connector - Q-CONN-3P-10M --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; font-family:Arial,Helvetica,sans-serif; color:#222; line-height:1.6;\"\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eEnphase IQ Field Wireable Three-Phase Male Connector\u003c\/strong\u003e (part number \u003cstrong\u003eQ-CONN-3P-10M\u003c\/strong\u003e) is the \u003cstrong\u003emale-gender field-wireable connector\u003c\/strong\u003e for three-phase Enphase Q Cable and IQ Cable installations. Designed for the sixth-generation \u003cstrong\u003eEnphase IQ System\u003c\/strong\u003e, these connectors allow installers to \u003cstrong\u003eterminate raw three-phase cable on-site\u003c\/strong\u003e without pre-made assemblies — providing maximum flexibility in three-phase microinverter array layouts. Compatible with conductor cross-sections from \u003cstrong\u003e2.5mm² to 6mm²\u003c\/strong\u003e and cable outer diameters of \u003cstrong\u003e8–21mm\u003c\/strong\u003e, the Q-CONN-3P-10M is rated to \u003cstrong\u003e690V AC and 25A\u003c\/strong\u003e with a \u003cstrong\u003eminimum IP67 protection class\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:12px; margin:20px 0;\"\u003e\n  \u003cdiv style=\"background:#008377CF; color:#fff; border-radius:6px; padding:14px 22px; text-align:center; min-width:140px;\"\u003e\n    \u003cdiv style=\"font-size:22px; font-weight:bold;\"\u003e690V AC\u003c\/div\u003e\n    \u003cdiv style=\"font-size:12px; margin-top:4px;\"\u003eRated Voltage\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#008377CF; color:#fff; border-radius:6px; padding:14px 22px; text-align:center; min-width:140px;\"\u003e\n    \u003cdiv style=\"font-size:22px; font-weight:bold;\"\u003e25A\u003c\/div\u003e\n    \u003cdiv style=\"font-size:12px; margin-top:4px;\"\u003eRated Current\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#008377CF; color:#fff; border-radius:6px; padding:14px 22px; text-align:center; min-width:140px;\"\u003e\n    \u003cdiv style=\"font-size:22px; font-weight:bold;\"\u003eIP67\u003c\/div\u003e\n    \u003cdiv style=\"font-size:12px; margin-top:4px;\"\u003eProtection Class\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#008377CF; color:#fff; border-radius:6px; padding:14px 22px; text-align:center; min-width:140px;\"\u003e\n    \u003cdiv style=\"font-size:22px; font-weight:bold;\"\u003e-40 to +110°C\u003c\/div\u003e\n    \u003cdiv style=\"font-size:12px; margin-top:4px;\"\u003eTemperature Range\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"border-left:4px solid #e53e3e; background:#fff5f5; padding:14px 18px; margin:20px 0; border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#e53e3e;\"\u003e⚠ Never Connect or Disconnect Under Load:\u003c\/strong\u003e The Q-CONN-3P-10M connectors are \u003cstrong\u003enot load-break rated\u003c\/strong\u003e. Always ensure the Enphase system AC power is fully disconnected before mating or separating connectors. Connection or disconnection under load may cause arcing, damage, or serious injury.\n\u003c\/div\u003e\n\n\u003cdiv style=\"border-left:4px solid #f6ad55; background:#fffaf0; padding:14px 18px; margin:20px 0; border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#b7791f;\"\u003e⚠ Phase Assignment:\u003c\/strong\u003e When assembling the connector, match conductors to the \u003cstrong\u003ecorrect L1, L2, L3, and Neutral terminals\u003c\/strong\u003e as labelled on the contact carrier. Incorrect phase assignment will affect the phase balance of the three-phase microinverter circuit and may cause system faults.\n\u003c\/div\u003e\n\n\u003cdiv style=\"border-left:4px solid #008377; background:#e6f4f3; padding:14px 18px; margin:20px 0; border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#008377;\"\u003eℹ Crimping Tool Required:\u003c\/strong\u003e Assembly of three-phase field wireable connectors requires a \u003cstrong\u003eMulti-Contact PV-compatible crimping tool\u003c\/strong\u003e. For flexible wires, Enphase recommends using \u003cstrong\u003eferrules\u003c\/strong\u003e before insertion into the contact carrier for a secure, corrosion-resistant termination.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display:grid; grid-template-columns:repeat(auto-fit,minmax(260px,1fr)); gap:16px; margin:24px 0;\"\u003e\n\n  \u003cdiv style=\"border:2px solid #008377; border-radius:8px; padding:18px;\"\u003e\n    \u003cdiv style=\"font-size:15px; font-weight:bold; color:#008377; border-bottom:2px solid #008377; padding-bottom:6px; margin-bottom:10px;\"\u003eEnd-Feed \u0026amp; Center-Feed Capability\u003c\/div\u003e\n    \u003cp\u003eA mated pair of Q-CONN-3P-10M (male) and Q-CONN-3P-10F (female) connectors enables \u003cstrong\u003eend-feeding of the branch circuit\u003c\/strong\u003e with an AC supply connection from raw cable. A male connector can also be used with appropriate adapter cables to \u003cstrong\u003ecenter-feed the branch\u003c\/strong\u003e, giving greater layout flexibility in complex rooftop arrays.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border:2px solid #008377; border-radius:8px; padding:18px;\"\u003e\n    \u003cdiv style=\"font-size:15px; font-weight:bold; color:#008377; border-bottom:2px solid #008377; padding-bottom:6px; margin-bottom:10px;\"\u003eCable Waste Elimination\u003c\/div\u003e\n    \u003cp\u003eBy allowing \u003cstrong\u003eon-site termination of raw Q Cable\u003c\/strong\u003e to the exact length needed, field wireable connectors eliminate the need for pre-made cable assemblies of fixed lengths. This reduces cable waste on site, simplifies logistics, and allows arrays positioned in multiple roof sections or buildings to be connected without excessive cable runs.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border:2px solid #008377; border-radius:8px; padding:18px;\"\u003e\n    \u003cdiv style=\"font-size:15px; font-weight:bold; color:#008377; border-bottom:2px solid #008377; padding-bottom:6px; margin-bottom:10px;\"\u003eBroad Cable Compatibility\u003c\/div\u003e\n    \u003cp\u003eThe connector accepts cable outer diameters of \u003cstrong\u003e8 to 21mm\u003c\/strong\u003e and conductor cross-sections of \u003cstrong\u003e2.5mm² to 6mm²\u003c\/strong\u003e, covering the full range of three-phase Q Cable and standard homerun cable gauges typically used in IQ Microinverter installations across the UK and Europe.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border:2px solid #008377; border-radius:8px; padding:18px;\"\u003e\n    \u003cdiv style=\"font-size:15px; font-weight:bold; color:#008377; border-bottom:2px solid #008377; padding-bottom:6px; margin-bottom:10px;\"\u003eIEC 61984 \u0026amp; IP67 Certified\u003c\/div\u003e\n    \u003cp\u003eCertified to \u003cstrong\u003eIEC 61984\u003c\/strong\u003e (connectors for low-voltage circuits) with a \u003cstrong\u003eminimum IP67 weatherproof rating\u003c\/strong\u003e and a temperature resistance of \u003cstrong\u003e90°C wet and dry\u003c\/strong\u003e. The Australian\/Enphase product page also notes IP66\/IP68, confirming the connectors comfortably exceed IP67 requirements — suitable for fully exposed rooftop use.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:15px; margin:24px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background:#008377; color:#fff;\"\u003e\n      \u003cth style=\"padding:10px 14px; text-align:left;\" colspan=\"2\"\u003eTechnical Specifications — Q-CONN-3P-10M (Three-Phase Male Connector)\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background:#e6f4f3;\"\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eQ-CONN-3P-10M\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eConnector Gender\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eMale (plug)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#e6f4f3;\"\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003ePhase Configuration\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eThree-phase (L1, L2, L3 + Neutral)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eRated Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eUp to 690V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#e6f4f3;\"\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eRated Current\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003e25A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eProtection Class\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eIP67 (IEC 60529); also noted as IP66\/IP68 in some regional documentation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#e6f4f3;\"\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eTemperature Range\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003e-40°C to +110°C; 90°C wet\/dry rated (per Enphase EU store)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eConductor Cross-Section\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003e2.5mm² to 6mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#e6f4f3;\"\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eCable Outer Diameter\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003e8–21mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eCertification\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eIEC 61984\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#e6f4f3;\"\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eAssembly Tool Required\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eMulti-Contact PV-compatible crimping tool\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eCompatible Mating Connector\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eQ-CONN-3P-10F (three-phase female)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#e6f4f3;\"\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eDisconnect Tool\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eQ-DISC-3P-10\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eEnphase IQ System (6th-generation Q Cable \/ three-phase)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"margin:24px 0;\"\u003e\n  \u003cdetails style=\"border:1px solid #008377; border-radius:6px; margin-bottom:10px;\"\u003e\n    \u003csummary style=\"background:#008377CF; color:#fff; padding:12px 16px; cursor:pointer; font-weight:bold; border-radius:5px;\"\u003eWhat is the difference between Q-CONN-3P-10M and Q-CONN-10M?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:14px 16px;\"\u003e\n      The \u003cstrong\u003eQ-CONN-3P-10M is the three-phase version\u003c\/strong\u003e for use with three-phase Q Cable carrying L1, L2, L3, and Neutral. The \u003cstrong\u003eQ-CONN-10M is the single-phase version\u003c\/strong\u003e for standard two-wire single-phase Q Cable. Ensure you order the correct connector for your cable type.\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n  \u003cdetails style=\"border:1px solid #008377; border-radius:6px; margin-bottom:10px;\"\u003e\n    \u003csummary style=\"background:#008377CF; color:#fff; padding:12px 16px; cursor:pointer; font-weight:bold; border-radius:5px;\"\u003eDo I need to buy the male and female connector separately?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:14px 16px;\"\u003e\n      Yes. The \u003cstrong\u003eQ-CONN-3P-10M (male) and Q-CONN-3P-10F (female)\u003c\/strong\u003e are sold individually. For an end-feed or junction connection, you will need one of each. Both are available from AIZO Quality Heating.\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n  \u003cdetails style=\"border:1px solid #008377; border-radius:6px; margin-bottom:10px;\"\u003e\n    \u003csummary style=\"background:#008377CF; color:#fff; padding:12px 16px; cursor:pointer; font-weight:bold; border-radius:5px;\"\u003eWhat tool do I need to disconnect a mated three-phase connector pair?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:14px 16px;\"\u003e\n      Use the \u003cstrong\u003eEnphase Q-DISC-3P-10 disconnect tool\u003c\/strong\u003e, which is the three-phase specific disconnect tool. The single-phase Q-DISC-10 is not suitable for three-phase connector bodies.\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n  \u003cdetails style=\"border:1px solid #008377; border-radius:6px; margin-bottom:10px;\"\u003e\n    \u003csummary style=\"background:#008377CF; color:#fff; padding:12px 16px; cursor:pointer; font-weight:bold; border-radius:5px;\"\u003eCan I use these connectors with standard market three-phase cable, not just Enphase Q Cable?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:14px 16px;\"\u003e\n      Yes — provided the cable has a \u003cstrong\u003econductor cross-section of 2.5mm² to 6mm²\u003c\/strong\u003e and an \u003cstrong\u003eouter diameter of 8–21mm\u003c\/strong\u003e. The connectors are compatible with Enphase raw three-phase Q Cable or equivalent homerun cable of suitable specification. Always follow the Enphase three-phase Q Cable design guide for maximum circuit lengths and current limits.\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Enphase","offers":[{"title":"Default Title","offer_id":64997153898845,"sku":"Q-CONN-3P-10M","price":11.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Enphase3phaseMaleConnector.jpg?v=1781701188","url":"https:\/\/qualityheating.co.uk\/products\/enphase-3-phase-q-cable-male-field-wireable-connector","provider":"AIZO Quality Heating","version":"1.0","type":"link"}