{"product_id":"enphase-3-phase-q-cable-female-field-wireable-connector","title":"Enphase 3-Phase Q Cable Female Field Wireable Connector","description":"\u003cdiv style=\"font-size:16px; max-width:900px; font-family:Arial,Helvetica,sans-serif; color:#222; line-height:1.6;\"\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eEnphase IQ Field Wireable Three-Phase Female Connector\u003c\/strong\u003e (part number \u003cstrong\u003eQ-CONN-3P-10F\u003c\/strong\u003e) is the \u003cstrong\u003efemale-gender field-wireable connector\u003c\/strong\u003e for three-phase Enphase Q Cable and IQ Cable installations. Part of the sixth-generation \u003cstrong\u003eEnphase IQ System\u003c\/strong\u003e, it allows installers to \u003cstrong\u003eterminate raw three-phase cable on-site\u003c\/strong\u003e at exactly the length required — eliminating pre-cut cable waste and enabling flexible AC wiring for arrays spread across multiple roof sections or buildings. Compatible with conductor sizes from \u003cstrong\u003e2.5mm² to 6mm²\u003c\/strong\u003e and cable outer diameters of \u003cstrong\u003e8–21mm\u003c\/strong\u003e, rated to \u003cstrong\u003e690V AC and 25A\u003c\/strong\u003e with an \u003cstrong\u003eIP67 protection class\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:12px; margin:20px 0;\"\u003e\n  \u003cdiv style=\"background:#008377CF; color:#fff; border-radius:6px; padding:14px 22px; text-align:center; min-width:140px;\"\u003e\n    \u003cdiv style=\"font-size:22px; font-weight:bold;\"\u003e690V AC\u003c\/div\u003e\n    \u003cdiv style=\"font-size:12px; margin-top:4px;\"\u003eRated Voltage\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#008377CF; color:#fff; border-radius:6px; padding:14px 22px; text-align:center; min-width:140px;\"\u003e\n    \u003cdiv style=\"font-size:22px; font-weight:bold;\"\u003e25A\u003c\/div\u003e\n    \u003cdiv style=\"font-size:12px; margin-top:4px;\"\u003eRated Current\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#008377CF; color:#fff; border-radius:6px; padding:14px 22px; text-align:center; min-width:140px;\"\u003e\n    \u003cdiv style=\"font-size:22px; font-weight:bold;\"\u003eIP67\u003c\/div\u003e\n    \u003cdiv style=\"font-size:12px; margin-top:4px;\"\u003eProtection Class\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#008377CF; color:#fff; border-radius:6px; padding:14px 22px; text-align:center; min-width:140px;\"\u003e\n    \u003cdiv style=\"font-size:22px; font-weight:bold;\"\u003e-40 to +110°C\u003c\/div\u003e\n    \u003cdiv style=\"font-size:12px; margin-top:4px;\"\u003eTemperature Range\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"border-left:4px solid #e53e3e; background:#fff5f5; padding:14px 18px; margin:20px 0; border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#e53e3e;\"\u003e⚠ Never Connect or Disconnect Under Load:\u003c\/strong\u003e These connectors are \u003cstrong\u003enot load-break rated\u003c\/strong\u003e. The Enphase system AC power must be \u003cstrong\u003efully disconnected\u003c\/strong\u003e before mating or separating connector pairs. Connecting or disconnecting under load risks arcing and damage to the connector contacts and to the microinverter AC circuitry.\n\u003c\/div\u003e\n\n\u003cdiv style=\"border-left:4px solid #f6ad55; background:#fffaf0; padding:14px 18px; margin:20px 0; border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#b7791f;\"\u003e⚠ Correct Phase Assignment Required:\u003c\/strong\u003e When assembling, match each conductor to the \u003cstrong\u003ecorrect phase terminal (L1, L2, L3, Neutral)\u003c\/strong\u003e as labelled on the contact carrier. A phase mismatch will disrupt the phase balance of the three-phase microinverter circuit and can cause system errors or generation loss.\n\u003c\/div\u003e\n\n\u003cdiv style=\"border-left:4px solid #008377; background:#e6f4f3; padding:14px 18px; margin:20px 0; border-radius:4px;\"\u003e\n  \u003cstrong style=\"color:#008377;\"\u003eℹ Crimping Tool \u0026amp; Ferrules Required:\u003c\/strong\u003e Assembly requires a \u003cstrong\u003eMulti-Contact PV-compatible crimping tool\u003c\/strong\u003e. For flexible conductors, Enphase recommends using \u003cstrong\u003eferrules\u003c\/strong\u003e to ensure a clean, reliable contact. Sold in packs of 10 — one connector per pack position.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display:grid; grid-template-columns:repeat(auto-fit,minmax(260px,1fr)); gap:16px; margin:24px 0;\"\u003e\n\n  \u003cdiv style=\"border:2px solid #008377; border-radius:8px; padding:18px;\"\u003e\n    \u003cdiv style=\"font-size:15px; font-weight:bold; color:#008377; border-bottom:2px solid #008377; padding-bottom:6px; margin-bottom:10px;\"\u003eFemale Socket — Q Cable Branch Connection\u003c\/div\u003e\n    \u003cp\u003eThe female Q-CONN-3P-10F \u003cstrong\u003econnects to any open three-phase Q Cable connector port\u003c\/strong\u003e, allowing the installer to bring in a raw cable feed to that point in the branch. In combination with the male Q-CONN-3P-10M, it enables \u003cstrong\u003eend-feed and center-feed configurations\u003c\/strong\u003e for three-phase microinverter branch circuits at any point along the array.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border:2px solid #008377; border-radius:8px; padding:18px;\"\u003e\n    \u003cdiv style=\"font-size:15px; font-weight:bold; color:#008377; border-bottom:2px solid #008377; padding-bottom:6px; margin-bottom:10px;\"\u003eRemote Array Section Connection\u003c\/div\u003e\n    \u003cp\u003eUsing \u003cstrong\u003emated pairs of male and female connectors\u003c\/strong\u003e, installers can bridge between separate sections of an array — for example, connecting a second roof slope or outbuilding array into the same three-phase Q Cable branch circuit. This eliminates the need for junction boxes and reduces overall system complexity.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border:2px solid #008377; border-radius:8px; padding:18px;\"\u003e\n    \u003cdiv style=\"font-size:15px; font-weight:bold; color:#008377; border-bottom:2px solid #008377; padding-bottom:6px; margin-bottom:10px;\"\u003eWide Cable Compatibility\u003c\/div\u003e\n    \u003cp\u003eAccepts cable outer diameters of \u003cstrong\u003e8–21mm\u003c\/strong\u003e and conductor cross-sections of \u003cstrong\u003e2.5mm² to 6mm²\u003c\/strong\u003e. Works with Enphase three-phase raw Q Cable and compatible homerun cables. The three-phase Q Cable contains \u003cstrong\u003efour flexible 2.5mm² conductors rated to 25A\u003c\/strong\u003e, with each connector supplying 230VAC L-N nominal per phase.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border:2px solid #008377; border-radius:8px; padding:18px;\"\u003e\n    \u003cdiv style=\"font-size:15px; font-weight:bold; color:#008377; border-bottom:2px solid #008377; padding-bottom:6px; margin-bottom:10px;\"\u003eRobust Weather \u0026amp; Temperature Rating\u003c\/div\u003e\n    \u003cp\u003eCertified to \u003cstrong\u003eIEC 61984\u003c\/strong\u003e with \u003cstrong\u003eIP67 protection\u003c\/strong\u003e and a temperature range of \u003cstrong\u003e-40°C to +110°C\u003c\/strong\u003e (90°C wet\/dry rating from Enphase EU documentation). This makes the Q-CONN-3P-10F fully suitable for exposed rooftop environments in all UK and European weather conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:15px; margin:24px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background:#008377; color:#fff;\"\u003e\n      \u003cth style=\"padding:10px 14px; text-align:left;\" colspan=\"2\"\u003eTechnical Specifications — Q-CONN-3P-10F (Three-Phase Female Connector)\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background:#e6f4f3;\"\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eQ-CONN-3P-10F\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eConnector Gender\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eFemale (socket)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#e6f4f3;\"\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003ePhase Configuration\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eThree-phase (L1, L2, L3 + Neutral)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eRated Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eUp to 690V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#e6f4f3;\"\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eRated Current\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003e25A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eProtection Class\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eIP67 (IEC 60529); also noted as IP66\/IP68 in some regional documentation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#e6f4f3;\"\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eTemperature Range\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003e-40°C to +110°C; 90°C wet\/dry rated (per Enphase EU store)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eConductor Cross-Section\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003e2.5mm² to 6mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#e6f4f3;\"\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eCable Outer Diameter\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003e8–21mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eCertification\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eIEC 61984\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#e6f4f3;\"\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eAssembly Tool Required\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eMulti-Contact PV-compatible crimping tool\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eCompatible Mating Connector\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eQ-CONN-3P-10M (three-phase male)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#e6f4f3;\"\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eDisconnect Tool\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eQ-DISC-3P-10\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:9px 14px; font-weight:bold;\"\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd style=\"padding:9px 14px;\"\u003eEnphase IQ System (6th-generation Q Cable \/ three-phase)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"margin:24px 0;\"\u003e\n  \u003cdetails style=\"border:1px solid #008377; border-radius:6px; margin-bottom:10px;\"\u003e\n    \u003csummary style=\"background:#008377CF; color:#fff; padding:12px 16px; cursor:pointer; font-weight:bold; border-radius:5px;\"\u003eWhat is the difference between Q-CONN-3P-10F and Q-CONN-10F?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:14px 16px;\"\u003e\n      The \u003cstrong\u003eQ-CONN-3P-10F is the three-phase female connector\u003c\/strong\u003e for three-phase Q Cable carrying L1, L2, L3, and Neutral. The \u003cstrong\u003eQ-CONN-10F is the single-phase female connector\u003c\/strong\u003e for two-wire single-phase Q Cable. Always match the connector to your cable type.\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n  \u003cdetails style=\"border:1px solid #008377; border-radius:6px; margin-bottom:10px;\"\u003e\n    \u003csummary style=\"background:#008377CF; color:#fff; padding:12px 16px; cursor:pointer; font-weight:bold; border-radius:5px;\"\u003eDo I need both male and female connectors for a field connection?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:14px 16px;\"\u003e\n      Yes. For an \u003cstrong\u003eend-feed or junction splice\u003c\/strong\u003e, you need one \u003cstrong\u003eQ-CONN-3P-10M (male)\u003c\/strong\u003e and one \u003cstrong\u003eQ-CONN-3P-10F (female)\u003c\/strong\u003e. They mate together to form the complete electrical connection. Both parts are available separately from AIZO Quality Heating.\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n  \u003cdetails style=\"border:1px solid #008377; border-radius:6px; margin-bottom:10px;\"\u003e\n    \u003csummary style=\"background:#008377CF; color:#fff; padding:12px 16px; cursor:pointer; font-weight:bold; border-radius:5px;\"\u003eWhat disconnect tool is needed for three-phase connectors?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:14px 16px;\"\u003e\n      Use the \u003cstrong\u003eEnphase Q-DISC-3P-10 three-phase disconnect tool\u003c\/strong\u003e. This is a different tool from the single-phase Q-DISC-10 and is specifically designed for the three-phase connector body.\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n  \u003cdetails style=\"border:1px solid #008377; border-radius:6px; margin-bottom:10px;\"\u003e\n    \u003csummary style=\"background:#008377CF; color:#fff; padding:12px 16px; cursor:pointer; font-weight:bold; border-radius:5px;\"\u003eHow many microinverters can a three-phase Q Cable branch support?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:14px 16px;\"\u003e\n      A \u003cstrong\u003emaximum 25A circuit breaker\u003c\/strong\u003e is required on each three-phase microinverter circuit. The maximum number of IQ Microinverters per circuit depends on the inverter model and output rating — refer to the \u003cstrong\u003eEnphase Three-Phase Q Cable Design Technical Brief\u003c\/strong\u003e and use the Enphase Vrise Calculator to confirm your installation design.\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Enphase","offers":[{"title":"Default Title","offer_id":64997161664861,"sku":"Q-CONN-3P-10F","price":11.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/enphase3phasefemaleconnector.jpg?v=1781701458","url":"https:\/\/qualityheating.co.uk\/products\/enphase-3-phase-q-cable-female-field-wireable-connector","provider":"AIZO Quality Heating","version":"1.0","type":"link"}