{"product_id":"elterm-low-loss-header-1-40kw-insulated-hydraulic-separator","title":"Elterm Low Loss Header 1\" 40kW Insulated Hydraulic Separator","description":"\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#2B2B2B; line-height:1.6; font-family:Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"line-height:1.7; margin:0 0 16px 0; font-size:16px;\"\u003eThe \u003cstrong\u003eElterm SHE-OC 40\u003c\/strong\u003e is a fully \u003cstrong\u003einsulated hydraulic low loss header\u003c\/strong\u003e rated to \u003cstrong\u003e40kW\u003c\/strong\u003e, designed to hydraulically separate the primary heat source circuit (boiler or heat pump) from the secondary heating circuit(s). Fitted with \u003cstrong\u003e1\" (25mm) threaded connections\u003c\/strong\u003e, it is the most widely specified size in the Elterm SHE-OC range and is commonly paired with domestic and light commercial \u003cstrong\u003eheat pumps\u003c\/strong\u003e, gas and oil boilers, and multi-zone heating systems.\u003c\/p\u003e\n\u003cp style=\"line-height:1.7; margin:0 0 16px 0; font-size:16px;\"\u003eHydraulic separation removes the need to manually balance pump flow rates between the primary and secondary circuits, allowing each pump to operate independently without interference. The unit also incorporates \u003cstrong\u003edesludging and automatic air venting\u003c\/strong\u003e functions, and its \u003cstrong\u003ebuilt-in neodymium magnetic SMART separator\u003c\/strong\u003e captures ferromagnetic debris circulating in the system water, protecting the heat source heat exchanger from fouling.\u003c\/p\u003e\n    \u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 -4px 26px -4px;\"\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e40 kW\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eMax. Power (ΔT=15K)\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e55 kW\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eMax. Power (ΔT=20K)\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e1\" (25mm)\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eConnection Size\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e2.3 m³\/h\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eMax. Flow Rate\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e110°C\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eMax. Temperature\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e6 bar\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eNominal Pressure\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background:#E6F4F3; border-left:4px solid #008377CF; padding:14px 18px; margin:0 0 18px 0; border-radius:4px;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:4px; font-size:14px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eGood to Know: Built-In Magnetic Filtration\u003c\/div\u003e\n        \u003cdiv style=\"font-size:15px; color:#2B2B2B;\"\u003eThis model includes the \u003cstrong\u003epatented neodymium SMART magnetic separator\u003c\/strong\u003e as standard, which continuously removes ferromagnetic sludge and debris from the circulating water without needing a separate in-line magnetic filter.\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background:#FFF6E5; border-left:4px solid #E0942A; padding:14px 18px; margin:0 0 18px 0; border-radius:4px;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#E0942A; margin-bottom:4px; font-size:14px; text-transform:uppercase; letter-spacing:0.03em;\"\u003ePlease Note: Vertical Installation Only\u003c\/div\u003e\n        \u003cdiv style=\"font-size:15px; color:#2B2B2B;\"\u003eThe manufacturer states this header \u003cstrong\u003emust be installed vertically\u003c\/strong\u003e, with the automatic air vent positioned in the upper section. The larger primary (boiler\/heat pump) connections are marked with directional arrows and must be connected exactly as labelled: supply to the upper stub, return to the lower stub.\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 -6px 26px -6px;\"\u003e\n        \u003cdiv style=\"flex:1 1 45%; min-width:250px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px 18px; margin:6px; box-sizing:border-box;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eIndependent Circuit Operation\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.55;\"\u003eBy hydraulically decoupling the primary and secondary circuits, each pump can be sized and controlled independently, eliminating the flow-rate conflicts that cause short-cycling and reduced boiler or heat pump efficiency.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 45%; min-width:250px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px 18px; margin:6px; box-sizing:border-box;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eEPP Insulated Body\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.55;\"\u003eThe \u003cstrong\u003eSHE-OC\u003c\/strong\u003e designation denotes the insulated version of the Elterm SHE range, finished in moulded EPP foam to minimise standing heat loss from the header body when not in active use.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 45%; min-width:250px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px 18px; margin:6px; box-sizing:border-box;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eReturn Water Temperature Protection\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.55;\"\u003eBy maintaining a stable minimum return temperature to the heat source, the header helps protect boilers from low-temperature return water corrosion and supports more consistent heat pump flow temperatures.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 45%; min-width:250px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px 18px; margin:6px; box-sizing:border-box;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eAutomatic Air Venting \u0026amp; Desludging\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.55;\"\u003eAn integrated automatic air vent continuously purges trapped air, while a drain valve at the base allows the system to be flushed of sediment during commissioning and annual maintenance.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 45%; min-width:250px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px 18px; margin:6px; box-sizing:border-box;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eWall-Mounting Bracket Included\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.55;\"\u003eUnits in this power range are supplied with a \u003cstrong\u003emounting bracket\u003c\/strong\u003e as standard, simplifying installation against a plant room wall without additional structural support.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 45%; min-width:250px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px 18px; margin:6px; box-sizing:border-box;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eCompatible With Elterm Distribution Manifolds\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.55;\"\u003eThe 125mm connection spacing on this header is compatible with Elterm's \u003cstrong\u003eRGP 2D+ and 3D+ pumped distribution manifolds\u003c\/strong\u003e, allowing the system to be expanded into multiple heating zones from a single low loss header.\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003ctable style=\"width:100%; border-collapse:collapse; margin:0 0 28px 0; font-size:14.5px;\"\u003e\n        \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 14px; font-size:14.5px;\"\u003eIdentification\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#FFFFFF;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eManufacturer\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003eElterm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#F2F8F7;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eModel\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003eSHE 40-OC (25\/65)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#FFFFFF;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eProduct Code\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003eSHE-OC 40 \/ 402040\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#F2F8F7;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eEAN\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003e5904378081287\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#FFFFFF;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eRange\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003eSHE-OC insulated low loss headers\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 14px; font-size:14.5px;\"\u003ePerformance\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#FFFFFF;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eMax. Power (ΔT = 15K)\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003e40 kW\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#F2F8F7;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eMax. Power (ΔT = 20K)\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003e55 kW\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#FFFFFF;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eMax. Flow Rate\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003e2.3 m³\/h\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#F2F8F7;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eMax. Operating Temperature\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003e110°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#FFFFFF;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eNominal Pressure\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003e6 bar\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 14px; font-size:14.5px;\"\u003ePhysical\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#FFFFFF;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eConnection Size (A)\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003e1\" (25mm) threaded, internal\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#F2F8F7;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eInternal Volume\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003e1.4 litres\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#FFFFFF;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eOverall Height (HC)\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003e≈600 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#F2F8F7;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003ePrimary Connection Height (H1)\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003e290 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#FFFFFF;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eSecondary Connection Height (H2)\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003e250 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#F2F8F7;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eInsulation\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003eEPP moulded foam\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#FFFFFF;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eMounting\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003eWall bracket included\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 14px; font-size:14.5px;\"\u003eConstruction \u0026amp; Features\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#FFFFFF;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eMagnetic Separator\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003eBuilt-in neodymium SMART magnet\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#F2F8F7;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eAir Venting\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003eAutomatic air vent, top-mounted\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#FFFFFF;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eDrain \/ Desludge Valve\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003eIntegrated base drain valve\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#F2F8F7;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eTemperature Sensing\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003eCapillary measuring pocket for sensor\/thermometer\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#FFFFFF;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eCompatible Manifolds\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003eElterm RGP 2D+ \/ RGP 3D+ (125mm connection spacing)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 14px; font-size:14.5px;\"\u003eCompliance \u0026amp; Warranty\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#FFFFFF;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003ePressure Equipment Compliance\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003eManufactured to PED 2014\/68\/EU, EN 13445\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background:#F2F8F7;\"\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA; font-weight:600; width:45%;\"\u003eManufacturer Warranty\u003c\/td\u003e\n            \u003ctd style=\"padding:9px 14px; border-bottom:1px solid #D9EDEA;\"\u003e2 years (24 months) from date of sale\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n    \u003cdetails style=\"margin:0 0 10px 0; border:1px solid #D9EDEA; border-radius:6px; overflow:hidden;\"\u003e\n        \u003csummary style=\"background:#008377CF; color:#FFFFFF; padding:12px 16px; font-weight:700; cursor:pointer; font-size:15px; list-style:none;\"\u003eDoes the SHE-OC 40 need to be installed vertically?\u003c\/summary\u003e\n        \u003cdiv style=\"padding:14px 16px; font-size:14.5px; line-height:1.6; background:#FFFFFF;\"\u003eYes. Elterm's installation manual specifies the header must be mounted \u003cstrong\u003evertically\u003c\/strong\u003e, with the automatic air vent at the top. The primary (heat source) connections are the larger upper stubs and must be piped exactly to the arrows marked on the casing.\u003c\/div\u003e\n    \u003c\/details\u003e\n    \u003cdetails style=\"margin:0 0 10px 0; border:1px solid #D9EDEA; border-radius:6px; overflow:hidden;\"\u003e\n        \u003csummary style=\"background:#008377CF; color:#FFFFFF; padding:12px 16px; font-weight:700; cursor:pointer; font-size:15px; list-style:none;\"\u003eIs this the insulated or non-insulated version?\u003c\/summary\u003e\n        \u003cdiv style=\"padding:14px 16px; font-size:14.5px; line-height:1.6; background:#FFFFFF;\"\u003eThis is the \u003cstrong\u003einsulated (SHE-OC) version\u003c\/strong\u003e, finished with moulded EPP foam to reduce standing heat loss. Elterm also produce a non-insulated 'SHE' equivalent at the same power rating for installations where the header will be boxed in or is not required to retain heat.\u003c\/div\u003e\n    \u003c\/details\u003e\n    \u003cdetails style=\"margin:0 0 10px 0; border:1px solid #D9EDEA; border-radius:6px; overflow:hidden;\"\u003e\n        \u003csummary style=\"background:#008377CF; color:#FFFFFF; padding:12px 16px; font-weight:700; cursor:pointer; font-size:15px; list-style:none;\"\u003eWhat is the built-in magnet for?\u003c\/summary\u003e\n        \u003cdiv style=\"padding:14px 16px; font-size:14.5px; line-height:1.6; background:#FFFFFF;\"\u003eThe \u003cstrong\u003eneodymium SMART magnetic separator\u003c\/strong\u003e is built into the header body and continuously attracts ferromagnetic particles (rust and sludge) circulating in the system water, reducing the fouling load reaching the boiler or heat pump heat exchanger.\u003c\/div\u003e\n    \u003c\/details\u003e\n    \u003cdetails style=\"margin:0 0 10px 0; border:1px solid #D9EDEA; border-radius:6px; overflow:hidden;\"\u003e\n        \u003csummary style=\"background:#008377CF; color:#FFFFFF; padding:12px 16px; font-weight:700; cursor:pointer; font-size:15px; list-style:none;\"\u003eCan this header be used with a heat pump?\u003c\/summary\u003e\n        \u003cdiv style=\"padding:14px 16px; font-size:14.5px; line-height:1.6; background:#FFFFFF;\"\u003eYes. Low loss headers in this range are commonly specified alongside domestic and light commercial heat pumps to hydraulically separate the heat pump's fixed minimum flow circuit from the secondary heating circuit(s), which is often a stated requirement in heat pump installation manuals.\u003c\/div\u003e\n    \u003c\/details\u003e\n    \u003cdetails style=\"margin:0 0 10px 0; border:1px solid #D9EDEA; border-radius:6px; overflow:hidden;\"\u003e\n        \u003csummary style=\"background:#008377CF; color:#FFFFFF; padding:12px 16px; font-weight:700; cursor:pointer; font-size:15px; list-style:none;\"\u003eDoes the 40kW rating change with flow temperature?\u003c\/summary\u003e\n        \u003cdiv style=\"padding:14px 16px; font-size:14.5px; line-height:1.6; background:#FFFFFF;\"\u003eThe 40kW figure is based on a 15K temperature differential (ΔT=15K) across the header. At a 20K differential the same unit is rated to 55kW, reflecting the higher heat carried per litre of flow at a wider temperature split.\u003c\/div\u003e\n    \u003c\/details\u003e\n    \u003cdetails style=\"margin:0 0 10px 0; border:1px solid #D9EDEA; border-radius:6px; overflow:hidden;\"\u003e\n        \u003csummary style=\"background:#008377CF; color:#FFFFFF; padding:12px 16px; font-weight:700; cursor:pointer; font-size:15px; list-style:none;\"\u003eIs a mounting bracket included?\u003c\/summary\u003e\n        \u003cdiv style=\"padding:14px 16px; font-size:14.5px; line-height:1.6; background:#FFFFFF;\"\u003eYes, Elterm supplies units up to and including the 100kW size in this range with a \u003cstrong\u003ewall-mounting bracket\u003c\/strong\u003e as standard.\u003c\/div\u003e\n    \u003c\/details\u003e\n\u003c\/div\u003e","brand":"Elterm","offers":[{"title":"Default Title","offer_id":65336383996253,"sku":"SHE-OC-40","price":170.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/EltermLowLossHeader1inch40kWInsulatedHydraulicSeparator.jpg?v=1784712649","url":"https:\/\/qualityheating.co.uk\/products\/elterm-low-loss-header-1-40kw-insulated-hydraulic-separator","provider":"AIZO Quality Heating","version":"1.0","type":"link"}