{"product_id":"ecoflow-1ph-smart-meter-with-120a-cts-mid-approved-for-octopus-tenant-power","title":"EcoFlow 1ph Smart Meter with 120A CTs (MID Approved) for Octopus Tenant Power","description":"\u003c!-- SEO Product Name: EcoFlow 1ph Smart Meter with 120A CTs (MID Approved) | EFA-ADL200N-CT --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#2B2B2B; line-height:1.6; font-family:Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eThe \u003cstrong\u003eEcoFlow Single-Phase Smart Meter\u003c\/strong\u003e (model \u003cstrong\u003eEFA-ADL200N-CT\u003c\/strong\u003e) is a DIN-rail mounted energy meter used to add accurate, real-time power monitoring to a compatible EcoFlow home energy system. It measures grid import and export using an \u003cstrong\u003eexternal 120A current transformer (CT)\u003c\/strong\u003e, giving the inverter the live consumption data it needs to manage battery charging, discharging and self-consumption automatically.\u003c\/p\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eThis particular variant is \u003cstrong\u003eMID (Measuring Instruments Directive) approved\u003c\/strong\u003e and is supplied specifically for installations on the \u003cstrong\u003eOctopus Energy Tenant Power tariff\u003c\/strong\u003e. It is a bi-directional single-phase meter with \u003cstrong\u003eRS485 (Modbus-RTU) communication\u003c\/strong\u003e, allowing it to report live voltage, current, active power and energy data back to the connected EcoFlow inverter.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:20px -4px 24px -4px;\"\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 10px; border-radius:8px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e120 A\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.92;\"\u003eExternal CT Rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 10px; border-radius:8px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e1-Phase\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.92;\"\u003eBi-Directional Metering\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 10px; border-radius:8px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eClass 1.0\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.92;\"\u003eAccuracy Class\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 10px; border-radius:8px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eMID\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.92;\"\u003eCertified\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 10px; border-radius:8px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eRS485\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.92;\"\u003eModbus-RTU Comms\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 10px; border-radius:8px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e35mm\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.92;\"\u003eDIN Rail Mount\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FDECEC; border-left:4px solid #D32F2F; border-radius:0 8px 8px 0; padding:14px 18px; margin:10px 0 18px 0; font-size:15px; color:#2B2B2B;\"\u003e\n\u003cstrong\u003eImportant Safety Information:\u003c\/strong\u003e This meter is \u003cstrong\u003eMID approved specifically for the Octopus Energy Tenant Power tariff\u003c\/strong\u003e and is paired with pre-set parameters for that use case before dispatch. It is \u003cstrong\u003enot intended for general-purpose installations\u003c\/strong\u003e — a system cannot be commissioned with this meter unless it is being installed for the Octopus Tenant Power tariff. For any other application, use the standard EcoFlow single-phase smart meter instead.\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; letter-spacing:0.04em; text-transform:uppercase; padding:10px 16px; border-radius:6px; margin:28px 0 14px 0;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 -4px 20px -4px;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eExternal 120A CT Measurement\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eUses a \u003cstrong\u003eclamp-on 120A current transformer\u003c\/strong\u003e supplied with the meter, allowing installation without breaking into the main current-carrying conductors directly at the meter body.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eMID Approved Accuracy\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eCertified to the \u003cstrong\u003eMeasuring Instruments Directive (MID)\u003c\/strong\u003e with a \u003cstrong\u003eClass 1.0 accuracy rating\u003c\/strong\u003e, suitable for tariff billing and export verification purposes.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eBi-Directional Energy Metering\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eMeasures both \u003cstrong\u003eimported and exported energy\u003c\/strong\u003e independently, giving the connected EcoFlow inverter the data it needs for accurate self-consumption optimisation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eRS485 Modbus-RTU Communication\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eCommunicates with the EcoFlow hybrid inverter via \u003cstrong\u003eRS485 (Modbus-RTU)\u003c\/strong\u003e, enabling real-time power sampling for smart charge\/discharge control.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eCompact DIN Rail Design\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eMounts to a standard \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e inside the consumer unit or distribution board, keeping the installation neat and space-efficient.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003ePre-Configured for Octopus Tenant Power\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eSupplied with \u003cstrong\u003eparameters pre-set\u003c\/strong\u003e for the Octopus Tenant Power tariff, simplifying commissioning for this specific use case.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; letter-spacing:0.04em; text-transform:uppercase; padding:10px 16px; border-radius:6px; margin:28px 0 14px 0;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; overflow:hidden; margin-bottom:20px;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13px; letter-spacing:0.04em; text-transform:uppercase; padding:9px 14px;\"\u003eGeneral\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eManufacturer\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eEcoFlow\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eModel\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eEFA-ADL200N-CT\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eProduct Type\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eSingle-Phase External CT Smart Meter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eCertification\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eMID, CE\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eTariff Compatibility\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eOctopus Energy Tenant Power only (pre-configured)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13px; letter-spacing:0.04em; text-transform:uppercase; padding:9px 14px;\"\u003eElectrical\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003ePhase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eSingle-phase, 2-wire\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eRated Voltage\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eAC 110–240V (direct connection)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eCurrent Measurement\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eExternal CT, 120A \/ 40mA rated\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eAccuracy Class\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003e1.0\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eFrequency Range\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003e45–65Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eMeasurement Type\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eBi-directional active energy, power, current, voltage\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13px; letter-spacing:0.04em; text-transform:uppercase; padding:9px 14px;\"\u003eCommunication \u0026amp; Installation\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eCommunication Protocol\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eRS485 (Modbus-RTU)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eMounting\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003e35mm DIN rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eDimensions (W×D×H)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eApprox. 18 × 90 × 65 mm (meter body)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eCompatible Systems\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eEcoFlow PowerOcean and OCEAN 2 single-phase hybrid inverter systems\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFF6E5; border-left:4px solid #E0942A; border-radius:0 8px 8px 0; padding:14px 18px; margin:10px 0 18px 0; font-size:15px; color:#2B2B2B;\"\u003e\n\u003cstrong\u003ePlease Note:\u003c\/strong\u003e An additional external CT meter of this type is typically required where a \u003cstrong\u003ethird-party string inverter\u003c\/strong\u003e is already installed alongside the EcoFlow system, so that the EcoFlow inverter can correctly measure whole-home import and export.\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; letter-spacing:0.04em; text-transform:uppercase; padding:10px 16px; border-radius:6px; margin:28px 0 14px 0;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eCan I use this meter on any EcoFlow installation?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eNo. This specific meter is \u003cstrong\u003eMID approved and pre-configured exclusively for the Octopus Energy Tenant Power tariff\u003c\/strong\u003e. It cannot be used to commission a system on any other tariff or installation type.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eWhat does the 120A CT measure?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eThe \u003cstrong\u003e120A current transformer (CT)\u003c\/strong\u003e clamps around the main current-carrying conductor to measure current without requiring the conductor to be broken or wired directly through the meter body.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eHow does the meter communicate with my EcoFlow inverter?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eIt uses \u003cstrong\u003eRS485 (Modbus-RTU) communication\u003c\/strong\u003e, allowing the connected EcoFlow hybrid inverter to receive live voltage, current and power data for accurate energy management.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eIs this meter suitable for tariff billing purposes?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eYes, it carries \u003cstrong\u003eMID (Measuring Instruments Directive) approval\u003c\/strong\u003e with a Class 1.0 accuracy rating, which is the standard required for metering used in tariff-related billing and verification.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eWhere is this meter installed?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eIt mounts to a standard \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e within the consumer unit or distribution board, alongside the other electrical protection devices for the installation.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"EcoFlow","offers":[{"title":"Default Title","offer_id":65685054980445,"sku":"EFA-ADL200N-CT","price":99.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/EcoFlow1phMeter.png?v=1767182532","url":"https:\/\/qualityheating.co.uk\/products\/ecoflow-1ph-smart-meter-with-120a-cts-mid-approved-for-octopus-tenant-power","provider":"AIZO Quality Heating","version":"1.0","type":"link"}