{"product_id":"drayton-trv4-15mm-angled-trv-valve-body-no-head-07-15-180","title":"Drayton TRV4 15mm Angled TRV Valve Body (No Head) - 07 15 180","description":"\u003c!-- SEO Product Name: Drayton TRV4 15mm Angled TRV Valve Body (No Head) - 07 15 180 --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#2B2B2B; line-height:1.6; font-family:Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eThe \u003cstrong\u003eDrayton TRV4 15mm Angled Valve Body\u003c\/strong\u003e (MPN \u003cstrong\u003e07 15 180\u003c\/strong\u003e) is the \u003cstrong\u003evalve body only\u003c\/strong\u003e, supplied without a sensing head. It's intended for installers replacing a worn valve body while reusing an existing TRV4 sensing head, or for new installations where the head is being purchased and fitted separately.\u003c\/p\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eThe body carries the same internal performance as the rest of the TRV4 range, including \u003cstrong\u003enon-stick valve internals\u003c\/strong\u003e, a \u003cstrong\u003edouble gland seal\u003c\/strong\u003e, and a \u003cstrong\u003epre-setting facility\u003c\/strong\u003e to balance the radiator's flow rate directly from the valve. As a 15mm angled body, it accepts any standard TRV4 sensing head via the \u003cstrong\u003eM30 x 1.5mm\u003c\/strong\u003e fitting.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:20px -4px 24px -4px;\"\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e15mm\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:500; margin-top:4px; opacity:0.92;\"\u003eValve Size\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003eAngled\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:500; margin-top:4px; opacity:0.92;\"\u003eBody Style\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003eNo Head\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:500; margin-top:4px; opacity:0.92;\"\u003eSupplied Without\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003eM30 x 1.5mm\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:500; margin-top:4px; opacity:0.92;\"\u003eHead Fitting\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e10 bar\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:500; margin-top:4px; opacity:0.92;\"\u003eMax Static Pressure\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e110°C\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:500; margin-top:4px; opacity:0.92;\"\u003eMax Flow Temperature\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FDECEC; border-left:4px solid #D32F2F; border-radius:0 8px 8px 0; padding:14px 18px; margin:0 0 20px 0;\"\u003e\u003cp style=\"margin:0; font-size:15px; line-height:1.6; color:#2B2B2B;\"\u003e\u003cstrong\u003e⚠ Important Safety Information:\u003c\/strong\u003e This product is the \u003cstrong\u003evalve body only\u003c\/strong\u003e — no sensing head is included. A compatible \u003cstrong\u003eTRV4 sensing head\u003c\/strong\u003e must be purchased separately for the valve to function as a thermostatic radiator valve.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 -6px 24px -6px;\"\u003e\n\u003cdiv style=\"background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; flex:1 1 260px; margin:6px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eBody-Only Replacement\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; line-height:1.6; color:#2B2B2B;\"\u003eIdeal for \u003cstrong\u003ereplacing a worn or damaged valve body\u003c\/strong\u003e while keeping an existing, working TRV4 sensing head, avoiding the cost of a full valve and head assembly.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; flex:1 1 260px; margin:6px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eReverse Flow Capability\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; line-height:1.6; color:#2B2B2B;\"\u003eThe 15mm angled body supports \u003cstrong\u003einstallation on the flow or return\u003c\/strong\u003e, with the head fitted vertically or horizontally once attached.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; flex:1 1 260px; margin:6px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eNon-Stick Internals\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; line-height:1.6; color:#2B2B2B;\"\u003eValve internals are specially formulated to \u003cstrong\u003eresist limescale build-up\u003c\/strong\u003e, helping the valve continue to open and close freely over years of service.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; flex:1 1 260px; margin:6px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eDouble Gland Seal\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; line-height:1.6; color:#2B2B2B;\"\u003eA \u003cstrong\u003edouble gland seal\u003c\/strong\u003e protects against water leakage, with a top seal that allows the sensing head to be removed \u003cstrong\u003ewithout draining down the system\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; flex:1 1 260px; margin:6px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003ePre-Setting Balancing\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; line-height:1.6; color:#2B2B2B;\"\u003eThe two-pipe body includes a \u003cstrong\u003epre-setting facility\u003c\/strong\u003e, allowing installers to balance the radiator's flow rate directly from the valve during commissioning.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; flex:1 1 260px; margin:6px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eStandard M30 Head Fitting\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; line-height:1.6; color:#2B2B2B;\"\u003eAccepts any \u003cstrong\u003eTRV4-compatible sensing head\u003c\/strong\u003e via the standard \u003cstrong\u003eM30 x 1.5mm\u003c\/strong\u003e thread, in Classic, Chrome, White or Anthracite finish.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 24px 0;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:9px 14px; font-size:13px; letter-spacing:0.04em; text-transform:uppercase; border-radius:6px 6px 0 0;\"\u003eGeneral\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-top:none; border-radius:0 0 6px 6px; overflow:hidden;\"\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; padding:9px 14px; font-weight:600; color:#2B2B2B;\"\u003eMPN\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; padding:9px 14px; color:#2B2B2B;\"\u003e07 15 180\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; padding:9px 14px; font-weight:600; color:#2B2B2B;\"\u003eProduct type\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; padding:9px 14px; color:#2B2B2B;\"\u003eValve body only, no sensing head\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; padding:9px 14px; font-weight:600; color:#2B2B2B;\"\u003eBody style\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; padding:9px 14px; color:#2B2B2B;\"\u003eAngled\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; padding:9px 14px; font-weight:600; color:#2B2B2B;\"\u003eValve size\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; padding:9px 14px; color:#2B2B2B;\"\u003e15mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; padding:9px 14px; font-weight:600; color:#2B2B2B;\"\u003eHead fitting thread\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; padding:9px 14px; color:#2B2B2B;\"\u003eM30 x 1.5mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; padding:9px 14px; font-weight:600; color:#2B2B2B;\"\u003eConnection\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; padding:9px 14px; color:#2B2B2B;\"\u003eCompression fitting to BS EN 1254-2, 1\/2\" BSP threaded radiator connection\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F7FAFA; \"\u003e\n\u003cdiv style=\"flex:1 1 220px; padding:9px 14px; font-weight:600; color:#2B2B2B;\"\u003eMaterial\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; padding:9px 14px; color:#2B2B2B;\"\u003eChrome-plated brass\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"height:14px;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:9px 14px; font-size:13px; letter-spacing:0.04em; text-transform:uppercase; border-radius:6px 6px 0 0;\"\u003ePerformance\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-top:none; border-radius:0 0 6px 6px; overflow:hidden;\"\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; padding:9px 14px; font-weight:600; color:#2B2B2B;\"\u003eMaximum test pressure\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; padding:9px 14px; color:#2B2B2B;\"\u003e20 bar\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; padding:9px 14px; font-weight:600; color:#2B2B2B;\"\u003eMaximum flow temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; padding:9px 14px; color:#2B2B2B;\"\u003e110°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; padding:9px 14px; font-weight:600; color:#2B2B2B;\"\u003eMaximum static pressure\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; padding:9px 14px; color:#2B2B2B;\"\u003e10 bar at 65°C, 6 bar at 110°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; padding:9px 14px; font-weight:600; color:#2B2B2B;\"\u003eMaximum differential pressure\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; padding:9px 14px; color:#2B2B2B;\"\u003e1 bar, to ensure valve closure\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#F7FAFA; \"\u003e\n\u003cdiv style=\"flex:1 1 220px; padding:9px 14px; font-weight:600; color:#2B2B2B;\"\u003eMaximum recommended differential pressure\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; padding:9px 14px; color:#2B2B2B;\"\u003e0.2 bar, for low-noise operation\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"height:14px;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 8px 0;\"\u003e\n\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:13px 18px; font-size:15px; font-weight:700; cursor:pointer; list-style:none;\"\u003eDoes this include a sensing head?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px; font-size:14px; line-height:1.65; color:#2B2B2B; background:#ffffff;\"\u003eNo, MPN \u003cstrong\u003e07 15 180\u003c\/strong\u003e is the \u003cstrong\u003evalve body only\u003c\/strong\u003e. A compatible TRV4 sensing head must be fitted separately for it to work as a thermostatic radiator valve.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:13px 18px; font-size:15px; font-weight:700; cursor:pointer; list-style:none;\"\u003eWhich sensing heads are compatible with this body?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px; font-size:14px; line-height:1.65; color:#2B2B2B; background:#ffffff;\"\u003eAny \u003cstrong\u003eTRV4-compatible sensing head\u003c\/strong\u003e with the standard M30 x 1.5mm fitting, including Classic, Chrome, White and Anthracite finishes.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:13px 18px; font-size:15px; font-weight:700; cursor:pointer; list-style:none;\"\u003eCan this body be used with a TRV3 head?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px; font-size:14px; line-height:1.65; color:#2B2B2B; background:#ffffff;\"\u003eNo — \u003cstrong\u003eTRV4 sensing heads are not compatible with TRV3 bodies\u003c\/strong\u003e, and this is a TRV4 body. Use a genuine TRV4 head, or the dedicated TRV4-to-TRV3 conversion head where applicable.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:13px 18px; font-size:15px; font-weight:700; cursor:pointer; list-style:none;\"\u003eCan this valve be installed on the flow or return?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px; font-size:14px; line-height:1.65; color:#2B2B2B; background:#ffffff;\"\u003eYes, the 15mm angled body has \u003cstrong\u003ereverse flow capability\u003c\/strong\u003e and can be installed on either the flow or the return pipework.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:13px 18px; font-size:15px; font-weight:700; cursor:pointer; list-style:none;\"\u003eWhy would I buy just the valve body?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px; font-size:14px; line-height:1.65; color:#2B2B2B; background:#ffffff;\"\u003eIt's typically used when \u003cstrong\u003ereplacing a worn or damaged valve body\u003c\/strong\u003e while keeping an existing, working sensing head, or when the head is being sourced separately for a specific finish.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Drayton Controls","offers":[{"title":"Default Title","offer_id":65797336727901,"sku":"0715180","price":29.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/DraytonTRV415mmAngledTRVValveBody.jpg?v=1788419918","url":"https:\/\/qualityheating.co.uk\/products\/drayton-trv4-15mm-angled-trv-valve-body-no-head-07-15-180","provider":"AIZO Quality Heating","version":"1.0","type":"link"}