{"product_id":"biasi-multipoint-gas-water-heater-flue-accessories-wall-mount-horizontal-flue-vertical-flue-extensions-and-bends","title":"Biasi Multipoint Gas Water Heater Flue Accessories","description":"\u003cdiv style=\"font-size:16px;font-family:'Segoe UI',Tahoma,Geneva,Verdana,sans-serif;max-width:900px;margin:0 auto;color:#1a1a1a;line-height:1.65;\"\u003e\n\n  \u003cp style=\"margin:0 0 18px;\"\u003eThe \u003cstrong\u003eBiasi Multipoint flue accessories range\u003c\/strong\u003e is designed exclusively for the \u003cstrong\u003eBiasi Multipoint 14S and 16S gas instantaneous water heaters\u003c\/strong\u003e. The Multipoint uses a \u003cstrong\u003eØ 60\/100 mm coaxial flue system\u003c\/strong\u003e (C13\/C33 appliance type) — the same diameter as the Biasi condensing boiler range but with \u003cstrong\u003ededicated terminals and connectors specific to the Multipoint\u003c\/strong\u003e. These parts are \u003cstrong\u003enot interchangeable with the condensing boiler flue accessories\u003c\/strong\u003e. The system must exit through an external wall or roof; the flue \u003cstrong\u003ecannot be connected to a shared or common flue\u003c\/strong\u003e. All Multipoint flue accessories use push-fit connections with integrated seals. The Multipoint operates as a \u003cstrong\u003enon-condensing water heater\u003c\/strong\u003e, so flue gas temperatures reach up to \u003cstrong\u003e118°C at nominal input\u003c\/strong\u003e — all accessories are rated accordingly.\u003c\/p\u003e\n\n  \u003cdiv style=\"background:#fff4f4;border-left:4px solid #cc2222;border-radius:4px;padding:13px 16px;margin:0 0 14px;\"\u003e\n    \u003cstrong style=\"color:#cc2222;\"\u003eInstallation — Gas Safe Engineer Required.\u003c\/strong\u003e All Multipoint flue components must be \u003cstrong\u003einstalled by a Gas Safe Registered Engineer\u003c\/strong\u003e in accordance with current Gas Safety (Installation \u0026amp; Use) Regulations and the Biasi Multipoint installation manual. The flue \u003cstrong\u003emust not be connected to a common or shared chimney\u003c\/strong\u003e. The unit must be installed vertically — inclination will cause incomplete combustion. Maximum permitted flue lengths must not be exceeded. \u003cstrong\u003eDo not mix Multipoint flue parts with condensing boiler flue accessories\u003c\/strong\u003e — part numbers and terminal designs differ.\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"background:#fffbf0;border-left:4px solid #e09000;border-radius:4px;padding:13px 16px;margin:0 0 14px;\"\u003e\n    \u003cstrong style=\"color:#b06800;\"\u003eFlue Length and Elbow Deductions.\u003c\/strong\u003e The Multipoint 14S and 16S are \u003cstrong\u003eC13\/C33 appliance type\u003c\/strong\u003e with a Ø 60\/100 mm coaxial flue. Each \u003cstrong\u003e90° elbow deducts from the permitted maximum run\u003c\/strong\u003e; each \u003cstrong\u003e45° elbow deducts a smaller amount\u003c\/strong\u003e — refer to the Biasi Multipoint installation manual for the specific permitted maximum length for your installation route. The flue gas temperature at nominal input reaches \u003cstrong\u003e118°C\u003c\/strong\u003e, which is significantly higher than a condensing boiler — ensure all accessories, wall penetrations, and sealants are rated for this temperature.\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"background:#e6f4f3;border-left:4px solid #008377CF;border-radius:4px;padding:13px 16px;margin:0 0 22px;\"\u003e\n    \u003cstrong style=\"color:#005c54;\"\u003eMultipoint Flue System Overview.\u003c\/strong\u003e The Biasi Multipoint 14S and 16S connect to the flue via a \u003cstrong\u003esingle coaxial collar at the top of the unit\u003c\/strong\u003e (item 1 in the unit parts diagram). The coaxial system draws combustion air through the outer duct and exhausts flue gases through the inner duct — providing a \u003cstrong\u003eroom-sealed (fan-flued) installation\u003c\/strong\u003e with no requirement for additional room ventilation. A \u003cstrong\u003evertical connection adapter (10999.1399.0)\u003c\/strong\u003e is used when the flue must first exit the unit vertically before routing horizontally to the terminal.\n  \u003c\/div\u003e\n\n  \u003c!-- Products table --\u003e\n  \u003cp style=\"font-weight:700;font-size:16px;margin:0 0 12px;color:#005c54;border-bottom:2px solid #008377CF;padding-bottom:6px;\"\u003eBiasi Multipoint Flue Accessories\u003c\/p\u003e\n\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;margin:0 0 26px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background:#008377CF;color:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 10px;font-weight:700;width:30%;\"\u003eProduct\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;font-weight:700;width:18%;\"\u003ePart No.\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;font-weight:700;\"\u003eDescription\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n\n      \u003ctr style=\"background:#e6f4f3;\"\u003e\n        \u003ctd style=\"padding:9px 10px;font-weight:600;\"\u003eWall Mount Kit\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;\"\u003e10999.4111.0\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;\"\u003e\n\u003cstrong\u003eWall mounting kit for the Biasi Multipoint 14S and 16S water heater.\u003c\/strong\u003e Provides the wall fixings, expansion screws, and mounting hardware required to securely hang the Multipoint on the installation wall. The Multipoint must be mounted \u003cstrong\u003evertically on a flat, stable surface\u003c\/strong\u003e capable of supporting the unit's weight. When the installation wall is a combustible material, a \u003cstrong\u003enon-combustible heat-resistant mounting board\u003c\/strong\u003e exceeding the unit frame size by at least 10 mm in all directions must be used — this kit provides the fixing hardware for that board arrangement. Clearance requirements: \u003cstrong\u003e450 mm above\u003c\/strong\u003e, \u003cstrong\u003e50 mm each side\u003c\/strong\u003e, and \u003cstrong\u003e300 mm below\u003c\/strong\u003e the unit must be maintained to combustible materials. The installation template (Figure 5.6–5.8 in the Multipoint manual) shows the two top-hole and two bottom-hole fixing pattern with centres at \u003cstrong\u003e180 mm horizontally and 601 mm vertically\u003c\/strong\u003e.\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 10px;font-weight:600;\"\u003eHorizontal Flue Kit\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;\"\u003e10999.1398.0\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;\"\u003e\n\u003cstrong\u003eComplete horizontal flue terminal kit for the Biasi Multipoint 14S and 16S\u003c\/strong\u003e, Ø 60\/100 mm coaxial. Designed for a standard \u003cstrong\u003edirect through-wall exit\u003c\/strong\u003e where the flue exits horizontally through an external wall. Includes the terminal, outer air duct, inner flue pipe, and wall plate with all seals. The Multipoint flue terminal is \u003cstrong\u003especific to the Multipoint water heater\u003c\/strong\u003e and must not be substituted with condensing boiler terminals (different part numbers apply). For installations requiring a longer horizontal run, add \u003cstrong\u003e1 m extensions (10999.0149.0)\u003c\/strong\u003e and \u003cstrong\u003eelbows\u003c\/strong\u003e as required, staying within the maximum permitted flue length stated in the installation manual. The flue must slope \u003cstrong\u003eslightly downward towards the terminal\u003c\/strong\u003e to allow condensate drainage away from the unit.\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr style=\"background:#e6f4f3;\"\u003e\n        \u003ctd style=\"padding:9px 10px;font-weight:600;\"\u003eVertical Flue Kit\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;\"\u003e10999.1405.0\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;\"\u003e\n\u003cstrong\u003eComplete vertical flue terminal kit for the Biasi Multipoint 14S and 16S\u003c\/strong\u003e, Ø 60\/100 mm coaxial. Used for \u003cstrong\u003eroof-exit installations\u003c\/strong\u003e where a wall exit is not possible or practical. Includes the roof terminal, inner and outer pipes, and seals. An appropriate \u003cstrong\u003eroof flashing plate\u003c\/strong\u003e must be sourced to suit the specific roof type (pitched or flat) — verify compatibility and roof penetration requirements before installation. For longer vertical runs, \u003cstrong\u003e1 m extension pieces (10999.0149.0)\u003c\/strong\u003e and \u003cstrong\u003epipe support brackets\u003c\/strong\u003e are required at the intervals specified in the installation manual. The \u003cstrong\u003eVertical Connection adapter (10999.1399.0)\u003c\/strong\u003e is used at the boiler collar to transition from the unit's top connection to the vertical flue pipe.\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 10px;font-weight:600;\"\u003eVertical Connection Adapter\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;\"\u003e10999.1399.0\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;\"\u003e\n\u003cstrong\u003eVertical flue connection adaptor for the Biasi Multipoint 14S and 16S.\u003c\/strong\u003e Connects the coaxial flue collar at the \u003cstrong\u003etop of the Multipoint unit\u003c\/strong\u003e to a vertical or angled flue run. This adaptor is the \u003cstrong\u003efirst piece of the flue system at the boiler\u003c\/strong\u003e on a vertical installation, transitioning from the unit's integrated flue collar to the standard 60\/100 mm coaxial pipe system. Required on all vertical flue installations and on horizontal runs that route upward before turning horizontally. Supplied with integrated push-fit seal. \u003cstrong\u003eNote: the Multipoint flue collar connection geometry differs from the condensing boiler range\u003c\/strong\u003e — always use Multipoint-specific adaptor parts.\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr style=\"background:#e6f4f3;\"\u003e\n        \u003ctd style=\"padding:9px 10px;font-weight:600;\"\u003e1 m Flue Extension\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;\"\u003e10999.0149.0\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;\"\u003e\n\u003cstrong\u003e1 metre coaxial flue extension for the Biasi Multipoint 14S and 16S\u003c\/strong\u003e, Ø 60\/100 mm. Used to extend the flue run beyond the length provided in the terminal kit — on either horizontal or vertical routes. Each extension adds 1 m to the total flue run. Combine with \u003cstrong\u003e90° elbows (10999.0152.0)\u003c\/strong\u003e and \u003cstrong\u003e45° elbows (10999.0153.0)\u003c\/strong\u003e to navigate corners and obstructions. The total extended run must remain within the maximum permitted flue length for the Multipoint as stated in the installation manual. Push-fit connection with integrated seal — no additional sealant or adhesive required.\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 10px;font-weight:600;\"\u003e90° Flue Elbow\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;\"\u003e10999.0152.0\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;\"\u003e\n\u003cstrong\u003e90° coaxial elbow for the Biasi Multipoint 14S and 16S flue system\u003c\/strong\u003e, Ø 60\/100 mm. Changes the direction of the flue run by 90° — used to route the flue around structural obstacles, over ceilings, or to turn from a vertical to a horizontal run. \u003cstrong\u003eEach 90° elbow deducts from the maximum permitted flue length\u003c\/strong\u003e — refer to the Biasi Multipoint installation manual for the exact deduction value. Push-fit connection with integrated seal. \u003cstrong\u003eDo not use condensing boiler 90° elbows (e.g. 10999.0390.1) on the Multipoint\u003c\/strong\u003e — Multipoint-specific elbows must be used.\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr style=\"background:#e6f4f3;\"\u003e\n        \u003ctd style=\"padding:9px 10px;font-weight:600;\"\u003e45° Flue Elbow\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;\"\u003e10999.0153.0\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 10px;\"\u003e\n\u003cstrong\u003e45° coaxial elbow for the Biasi Multipoint 14S and 16S flue system\u003c\/strong\u003e, Ø 60\/100 mm. Provides a gentler 45° change of direction — useful for angling the flue gradually away from a wall surface, routing around shallow obstructions, or improving flue aesthetics where a 90° elbow would be intrusive. \u003cstrong\u003eEach 45° elbow deducts a smaller amount from the maximum permitted flue length\u003c\/strong\u003e than a 90° elbow — refer to the Biasi Multipoint installation manual for the exact deduction value. Two 45° elbows can be used in place of a single 90° elbow where a smoother bend is preferred. Push-fit connection with integrated seal.\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- Quick reference strip --\u003e\n  \u003cp style=\"font-weight:700;font-size:16px;margin:0 0 12px;color:#005c54;border-bottom:2px solid #008377CF;padding-bottom:6px;\"\u003eQuick Reference — Multipoint Flue Accessories at a Glance\u003c\/p\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:10px;margin:0 0 26px;\"\u003e\n    \u003cdiv style=\"background:#e6f4f3;border-radius:6px;padding:12px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#005c54;font-size:15px;\"\u003eWall Mount Kit\u003c\/div\u003e\n      \u003cdiv style=\"font-size:13px;color:#444;margin-top:4px;\"\u003e10999.4111.0\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background:#e6f4f3;border-radius:6px;padding:12px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#005c54;font-size:15px;\"\u003eHorizontal Flue Kit\u003c\/div\u003e\n      \u003cdiv style=\"font-size:13px;color:#444;margin-top:4px;\"\u003e10999.1398.0\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background:#e6f4f3;border-radius:6px;padding:12px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#005c54;font-size:15px;\"\u003eVertical Flue Kit\u003c\/div\u003e\n      \u003cdiv style=\"font-size:13px;color:#444;margin-top:4px;\"\u003e10999.1405.0\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background:#e6f4f3;border-radius:6px;padding:12px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#005c54;font-size:15px;\"\u003eVertical Connection\u003c\/div\u003e\n      \u003cdiv style=\"font-size:13px;color:#444;margin-top:4px;\"\u003e10999.1399.0\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background:#e6f4f3;border-radius:6px;padding:12px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#005c54;font-size:15px;\"\u003e1 m Extension\u003c\/div\u003e\n      \u003cdiv style=\"font-size:13px;color:#444;margin-top:4px;\"\u003e10999.0149.0\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background:#e6f4f3;border-radius:6px;padding:12px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#005c54;font-size:15px;\"\u003e90° Elbow\u003c\/div\u003e\n      \u003cdiv style=\"font-size:13px;color:#444;margin-top:4px;\"\u003e10999.0152.0\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background:#e6f4f3;border-radius:6px;padding:12px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#005c54;font-size:15px;\"\u003e45° Elbow\u003c\/div\u003e\n      \u003cdiv style=\"font-size:13px;color:#444;margin-top:4px;\"\u003e10999.0153.0\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- FAQs --\u003e\n  \u003cp style=\"font-weight:700;font-size:16px;margin:0 0 10px;color:#005c54;\"\u003eFrequently Asked Questions\u003c\/p\u003e\n\n  \u003cdetails style=\"border:1px solid #dde8e7;border-radius:6px;margin-bottom:8px;\"\u003e\n    \u003csummary style=\"background:#008377CF;color:#fff;padding:11px 15px;border-radius:5px;cursor:pointer;font-weight:600;list-style:none;\"\u003eCan I use Biasi condensing boiler flue accessories on the Multipoint?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:13px 15px;font-size:15px;\"\u003eNo. Although both the condensing boiler range and the Multipoint water heater use a \u003cstrong\u003eØ 60\/100 mm coaxial flue diameter\u003c\/strong\u003e, the terminal designs, connection geometry, and part numbers are \u003cstrong\u003edifferent and not interchangeable\u003c\/strong\u003e. The Multipoint operates at significantly higher flue gas temperatures (up to \u003cstrong\u003e118°C\u003c\/strong\u003e) compared to a condensing boiler (typically 40–85°C), and the dedicated Multipoint accessories are designed for these higher temperatures. Always use the Multipoint-specific parts listed above.\u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails style=\"border:1px solid #dde8e7;border-radius:6px;margin-bottom:8px;\"\u003e\n    \u003csummary style=\"background:#008377CF;color:#fff;padding:11px 15px;border-radius:5px;cursor:pointer;font-weight:600;list-style:none;\"\u003eCan the Multipoint be connected to a shared or common flue?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:13px 15px;font-size:15px;\"\u003eNo. The Biasi Multipoint installation manual explicitly states that \u003cstrong\u003ethe flue cannot be connected to a common flue\u003c\/strong\u003e. The unit must have its own dedicated sealed flue system exiting directly through an external wall or roof. This is a regulatory requirement under the Gas Safety (Installation \u0026amp; Use) Regulations and Building Regulations Part J.\u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails style=\"border:1px solid #dde8e7;border-radius:6px;margin-bottom:8px;\"\u003e\n    \u003csummary style=\"background:#008377CF;color:#fff;padding:11px 15px;border-radius:5px;cursor:pointer;font-weight:600;list-style:none;\"\u003eWhen do I need the Vertical Connection Adapter (10999.1399.0)?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:13px 15px;font-size:15px;\"\u003eThe \u003cstrong\u003eVertical Connection Adapter\u003c\/strong\u003e is required whenever the flue run exits the unit vertically — either on a full vertical (roof-exit) installation, or on an installation where the flue first rises vertically before being redirected horizontally to the wall terminal. It is the \u003cstrong\u003efirst piece of the flue system at the unit collar\u003c\/strong\u003e on these routes. On a direct horizontal wall-exit installation using the Horizontal Flue Kit (10999.1398.0), the connection at the unit is handled by the terminal kit itself and the adapter is not required.\u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails style=\"border:1px solid #dde8e7;border-radius:6px;margin-bottom:8px;\"\u003e\n    \u003csummary style=\"background:#008377CF;color:#fff;padding:11px 15px;border-radius:5px;cursor:pointer;font-weight:600;list-style:none;\"\u003eWhat clearances are required around the Multipoint on a combustible wall?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:13px 15px;font-size:15px;\"\u003eThe Biasi Multipoint installation manual requires the following minimum clearances to combustible materials: \u003cstrong\u003e450 mm above the unit\u003c\/strong\u003e, \u003cstrong\u003e50 mm each side\u003c\/strong\u003e, \u003cstrong\u003e300 mm below\u003c\/strong\u003e, and \u003cstrong\u003e350 mm in front\u003c\/strong\u003e. Where the installation wall itself is a combustible material, a \u003cstrong\u003enon-combustible heat-resistant mounting board\u003c\/strong\u003e extending at least 10 mm beyond the unit frame in all directions must be fitted before the Wall Mount Kit (10999.4111.0) is used. Electric wires and equipment must maintain a minimum \u003cstrong\u003e400 mm horizontal clearance\u003c\/strong\u003e from the unit.\u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails style=\"border:1px solid #dde8e7;border-radius:6px;margin-bottom:8px;\"\u003e\n    \u003csummary style=\"background:#008377CF;color:#fff;padding:11px 15px;border-radius:5px;cursor:pointer;font-weight:600;list-style:none;\"\u003eDoes the Multipoint need additional room ventilation because it is room-sealed?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:13px 15px;font-size:15px;\"\u003eNo. The Biasi Multipoint 14S and 16S are \u003cstrong\u003eroom-sealed (fan-flued) appliances — appliance type C13\/C33\u003c\/strong\u003e. Combustion air is drawn from outside through the outer duct of the coaxial flue system, and flue gases are expelled through the inner duct to outside. Because the unit does not draw air from the room, \u003cstrong\u003eno additional room ventilation is required\u003c\/strong\u003e for the combustion process. Standard room ventilation requirements for habitable spaces still apply in accordance with Building Regulations.\u003c\/div\u003e\n  \u003c\/details\u003e\n\n\u003c\/div\u003e","brand":"Biasi","offers":[{"title":"Wall Mount Kit","offer_id":64865285079389,"sku":"10999.4111.0","price":59.0,"currency_code":"GBP","in_stock":true},{"title":"Horizontal Flue Kit","offer_id":64865285112157,"sku":"10999.1398.0","price":60.0,"currency_code":"GBP","in_stock":true},{"title":"Vertical Flue Kit","offer_id":64865285144925,"sku":"10999.1405.0","price":130.0,"currency_code":"GBP","in_stock":true},{"title":"Vertical Connection Adapter","offer_id":64865285177693,"sku":"10999.1399.0","price":50.0,"currency_code":"GBP","in_stock":true},{"title":"1 m Flue Extension","offer_id":64865285538141,"sku":"10999.0149.0","price":65.0,"currency_code":"GBP","in_stock":true},{"title":"90° Flue Elbow","offer_id":64865285734749,"sku":"10999.0149.0","price":60.0,"currency_code":"GBP","in_stock":true},{"title":"45° Flue Elbow","offer_id":64865285701981,"sku":"10999.0153.0","price":60.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/PipeSpacingFrame-10999.0822.1.png?v=1780386758","url":"https:\/\/qualityheating.co.uk\/products\/biasi-multipoint-gas-water-heater-flue-accessories-wall-mount-horizontal-flue-vertical-flue-extensions-and-bends","provider":"AIZO Quality Heating","version":"1.0","type":"link"}