{"product_id":"belcom-firefighter-2x2x22awg-rs485-cable-lszh-4302p2254-01-600v","title":"Belcom FireFighter 2x2x22AWG RS485 Cable LSZH | 4302P2254-01 | 600V","description":"\u003c!-- SEO Product Name: Belcom FireFighter 2x2x22AWG RS485 Cable LSZH | 4302P2254-01 | 600V --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; color:#222222; line-height:1.5;\"\u003e\n\u003cp style=\"margin:0 0 14px 0; line-height:1.6;\"\u003eThe \u003cstrong\u003eBelcom FireFighter 430 Series 4302P2254-01\u003c\/strong\u003e is a \u003cstrong\u003e2 pair, 22AWG low capacitance RS485 \/ TIA-485 control cable\u003c\/strong\u003e built for interference-free, high-speed data transmission in demanding installations. It combines an \u003cstrong\u003eoverall aluminium\/polyester foil screen\u003c\/strong\u003e with a \u003cstrong\u003etinned copper braid (65% coverage)\u003c\/strong\u003e and a \u003cstrong\u003estranded tinned copper drain wire\u003c\/strong\u003e for a high level of noise protection.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0; line-height:1.6;\"\u003eThe black \u003cstrong\u003eLSZH FireFighter SHF-1 outer jacket\u003c\/strong\u003e delivers \u003cstrong\u003elow smoke, zero halogen\u003c\/strong\u003e performance with \u003cstrong\u003eEuroclass Dca,s1,d2,a1\u003c\/strong\u003e classification, making it a sound choice where fire behaviour matters. It suits \u003cstrong\u003eModbus, BACnet MS\/TP, HART and CanOpen\u003c\/strong\u003e networks, with a \u003cstrong\u003e600 V rating\u003c\/strong\u003e, a \u003cstrong\u003e-20°C to +90°C temperature range\u003c\/strong\u003e and \u003cstrong\u003eUV resistance to ISO 4892-2\/A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:10px; margin:18px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; padding:14px 8px; border-radius:8px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:bold;\"\u003e2 x 2\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003ePairs x 22AWG\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; padding:14px 8px; border-radius:8px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:bold;\"\u003e120 Ω\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eNominal impedance\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; padding:14px 8px; border-radius:8px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:bold;\"\u003e36.1 pF\/m\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eCapacitance (cond.\/cond.)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; padding:14px 8px; border-radius:8px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:bold;\"\u003e78%\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eVelocity of propagation\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; padding:14px 8px; border-radius:8px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:bold;\"\u003e600 V\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eRated voltage\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; padding:14px 8px; border-radius:8px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:bold;\"\u003eDca,s1,d2,a1\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eEuroclass\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:6px solid #c0392b; background:#fdecea; padding:12px 16px; margin:14px 0; border-radius:4px; line-height:1.55;\"\u003e\n\u003cstrong\u003eFire and installation compliance:\u003c\/strong\u003e Cable selection and fire performance must meet the project specification and BS 7671 requirements. Confirm the required cable class for the building before installing.\u003c\/div\u003e\n\u003cdiv style=\"border-left:6px solid #e6a100; background:#fff6e0; padding:12px 16px; margin:14px 0; border-radius:4px; line-height:1.55;\"\u003e\n\u003cstrong\u003ePlease note:\u003c\/strong\u003e The Euroclass rating includes \u003cstrong\u003ed2\u003c\/strong\u003e, which places no limit on flaming droplets. All values are nominal; the overall diameter is quoted at ±10% and values should be treated as a guide.\u003c\/div\u003e\n\u003cdiv style=\"border-left:6px solid #008377CF; background:#e6f3f2; padding:12px 16px; margin:14px 0; border-radius:4px; line-height:1.55;\"\u003e\n\u003cstrong\u003ePair colour code:\u003c\/strong\u003e Pair 1 is white\/blue paired with blue\/white. Pair 2 is \u003cstrong\u003ewhite\/orange paired with orange\/white\u003c\/strong\u003e.\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px 0; font-size:20px; color:#008377CF; border-bottom:2px solid #008377CF; padding-bottom:6px;\"\u003eKey Features\u003c\/h3\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:12px; margin:14px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 250px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:6px; padding:14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003eDouble screening\u003c\/div\u003e\n\u003cdiv style=\"line-height:1.5; font-size:15px;\"\u003e\n\u003cstrong\u003eAluminium\/polyester foil plus 65% tinned copper braid\u003c\/strong\u003e with a drain wire for enhanced noise protection in harsh environments.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 250px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:6px; padding:14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003eLow capacitance\u003c\/div\u003e\n\u003cdiv style=\"line-height:1.5; font-size:15px;\"\u003e\n\u003cstrong\u003e36.1 pF\/m conductor-to-conductor\u003c\/strong\u003e supports reliable high-speed RS485 data transmission.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 250px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:6px; padding:14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003eLSZH jacket\u003c\/div\u003e\n\u003cdiv style=\"line-height:1.5; font-size:15px;\"\u003e\n\u003cstrong\u003eFireFighter SHF-1 Low Smoke Zero Halogen\u003c\/strong\u003e compound, halogen free to IEC 60754 and low smoke to IEC 61034.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 250px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:6px; padding:14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003eFlame and fire retardant\u003c\/div\u003e\n\u003cdiv style=\"line-height:1.5; font-size:15px;\"\u003eFlame retardant to \u003cstrong\u003eIEC 60332-1\u003c\/strong\u003e and fire retardant to \u003cstrong\u003eIEC 60332-3-24\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 250px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:6px; padding:14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003eStranded tinned copper\u003c\/div\u003e\n\u003cdiv style=\"line-height:1.5; font-size:15px;\"\u003e\n\u003cstrong\u003e22AWG stranded tinned copper conductors\u003c\/strong\u003e with polyethylene (PE) insulation for flexibility and corrosion resistance.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 250px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:6px; padding:14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003eProtocol ready\u003c\/div\u003e\n\u003cdiv style=\"line-height:1.5; font-size:15px;\"\u003eSuited to \u003cstrong\u003eModbus, BACnet MS\/TP, HART and CanOpen\u003c\/strong\u003e automation systems.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px 0; font-size:20px; color:#008377CF; border-bottom:2px solid #008377CF; padding-bottom:6px;\"\u003eTechnical Specification\u003c\/h3\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:6px; overflow:hidden; margin:14px 0;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:10px 14px;\"\u003eGeneral\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eManufacturer\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eBelcom\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eSeries\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eFireFighter 430 Series\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003ePart number\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003e4302P2254-01\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eFormation\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003e2 x 2 x 22 AWG\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eApplication\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eRS485 \/ TIA-485 control and data cable\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:10px 14px;\"\u003eConstruction\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eConductor\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eStranded tinned copper wire (22AWG)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eInsulation\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003ePolyethylene (PE)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eOverall shield\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eAluminium\/polyester tape\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eDrain wire\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eStranded tinned copper wire\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eOverall braid shield\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eTinned copper wire braid, 65% coverage\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eOuter jacket\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eLSZH FireFighter SHF-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eColour\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eBlack\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eNominal overall diameter\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003e8.25 mm ± 10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eWeight\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003e108 kg\/km\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:10px 14px;\"\u003eElectrical\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eRated voltage\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003e600 V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eNominal capacitance (cond.\/cond.)\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003e36.1 pF\/m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eNominal capacitance (cond.\/cond.\/screen)\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003e65.6 pF\/m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eNominal conductor DC resistance\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003e48.2 Ω\/km\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eNominal shield DC resistance\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003e4.6 Ω\/km\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eNominal velocity of propagation\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003e78%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eNominal impedance\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003e120 Ω\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:10px 14px;\"\u003eEnvironmental and Fire Behaviour\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eTemperature range\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003e-20°C up to +90°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eUV resistance\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eISO 4892-2\/A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eFlame retardant\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eIEC 60332-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eFire retardant\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eIEC 60332-3-24\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eHalogen free\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eIEC 60754\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eSmoke emission\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eIEC 61034\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#eef6f5; padding:9px 14px; border-bottom:1px solid #d5e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold;\"\u003eEuroclass\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;\"\u003eDca,s1,d2,a1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px 0; font-size:20px; color:#008377CF; border-bottom:2px solid #008377CF; padding-bottom:6px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv style=\"margin:14px 0;\"\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:11px 14px; cursor:pointer; font-weight:bold;\"\u003eWhich protocols is this cable suitable for?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; line-height:1.55;\"\u003eThe manufacturer lists RS485 applications including \u003cstrong\u003eModbus, BACnet MS\/TP, HART and CanOpen\u003c\/strong\u003e automation systems.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:11px 14px; cursor:pointer; font-weight:bold;\"\u003eWhat is the cable impedance and capacitance?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; line-height:1.55;\"\u003eNominal impedance is \u003cstrong\u003e120 Ω\u003c\/strong\u003e. Capacitance is 36.1 pF\/m conductor-to-conductor and 65.6 pF\/m conductor-to-conductor-and-screen.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:11px 14px; cursor:pointer; font-weight:bold;\"\u003eIs it halogen free and low smoke?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; line-height:1.55;\"\u003eYes. The \u003cstrong\u003eLSZH FireFighter SHF-1 jacket\u003c\/strong\u003e is halogen free to IEC 60754 with smoke emission tested to IEC 61034, and carries a Euroclass of Dca,s1,d2,a1.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:11px 14px; cursor:pointer; font-weight:bold;\"\u003eWhat temperature range can it handle?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; line-height:1.55;\"\u003eThe rated temperature range is \u003cstrong\u003e-20°C up to +90°C\u003c\/strong\u003e, and the jacket is UV resistant to ISO 4892-2\/A.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:11px 14px; cursor:pointer; font-weight:bold;\"\u003eHow is the cable screened?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; line-height:1.55;\"\u003eEach cable has an \u003cstrong\u003eoverall aluminium\/polyester tape screen\u003c\/strong\u003e, a \u003cstrong\u003etinned copper braid with 65% coverage\u003c\/strong\u003e and a stranded tinned copper drain wire.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:11px 14px; cursor:pointer; font-weight:bold;\"\u003eWhat are the pair colours?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; line-height:1.55;\"\u003ePair 1 is white\/blue paired with blue\/white, and pair 2 is white\/orange paired with orange\/white.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Belcom","offers":[{"title":"Default Title","offer_id":67812199137670,"sku":"4302P2254","price":2.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/BelcomFireFighter2x2x22AWGRS485CableLSZH4302P2254.jpg?v=1793276081","url":"https:\/\/qualityheating.co.uk\/products\/belcom-firefighter-2x2x22awg-rs485-cable-lszh-4302p2254-01-600v","provider":"AIZO Quality Heating","version":"1.0","type":"link"}