{"product_id":"becker-and-wolf-floor-standing-300l-hot-water-heat-pump-r290","title":"Becker \u0026 Wolf 300L Floor Standing Heat Pump Water Heater R290 – BWHP300R290 – A+ Rated – WiFi – G3 Kit – Largest Domestic Model","description":"\u003cdiv style=\"font-family: inherit; font-size: 16px; line-height: 1.65; color: #111827;\"\u003e\n\u003cp style=\"margin-bottom: 1.4rem; line-height: 2.4;\"\u003e\u003cspan style=\"display: inline-block; background: #1a3a5c; color: #ffffff; border: 1.5px solid #1a3a5c; border-radius: 4px; padding: 4px 11px; font-size: 11px; font-weight: bold; letter-spacing: .06em; text-transform: uppercase; line-height: 1.6; margin-right: 5px; margin-bottom: 5px;\"\u003e300 Litres\u003c\/span\u003e \u003cspan style=\"display: inline-block; background: #0e7490; color: #ffffff; border: 1.5px solid #0e7490; border-radius: 4px; padding: 4px 11px; font-size: 11px; font-weight: bold; letter-spacing: .06em; text-transform: uppercase; line-height: 1.6; margin-right: 5px; margin-bottom: 5px;\"\u003eFloor Standing\u003c\/span\u003e \u003cspan style=\"display: inline-block; background: #0d9488; color: #ffffff; border: 1.5px solid #0d9488; border-radius: 4px; padding: 4px 11px; font-size: 11px; font-weight: bold; letter-spacing: .06em; text-transform: uppercase; line-height: 1.6; margin-right: 5px; margin-bottom: 5px;\"\u003eR290 Refrigerant\u003c\/span\u003e \u003cspan style=\"display: inline-block; background: #065f46; color: #ffffff; border: 1.5px solid #065f46; border-radius: 4px; padding: 4px 11px; font-size: 11px; font-weight: bold; letter-spacing: .06em; text-transform: uppercase; line-height: 1.6; margin-right: 5px; margin-bottom: 5px;\"\u003eA+ Energy Rating\u003c\/span\u003e \u003cspan style=\"display: inline-block; background: #b45309; color: #ffffff; border: 1.5px solid #b45309; border-radius: 4px; padding: 4px 11px; font-size: 11px; font-weight: bold; letter-spacing: .06em; text-transform: uppercase; line-height: 1.6; margin-right: 5px; margin-bottom: 5px;\"\u003eLargest Domestic Model\u003c\/span\u003e \u003cspan style=\"display: inline-block; background: #166534; color: #dcfce7; border: 1.5px solid #166534; border-radius: 4px; padding: 4px 11px; font-size: 11px; font-weight: bold; letter-spacing: .06em; text-transform: uppercase; line-height: 1.6; margin-right: 5px; margin-bottom: 5px;\"\u003eWiFi Smart Control\u003c\/span\u003e \u003cspan style=\"display: inline-block; background: #ffffff; color: #1a3a5c; border: 1.5px solid #ffffff; border-radius: 4px; padding: 4px 11px; font-size: 11px; font-weight: bold; letter-spacing: .06em; text-transform: uppercase; line-height: 1.6; margin-right: 5px; margin-bottom: 5px;\"\u003eG3 Kit Included\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 15.5px; color: #374151; margin-bottom: 1.4rem; line-height: 1.8;\"\u003eThe \u003cstrong style=\"color: #1a3a5c;\"\u003eBecker \u0026amp; Wolf BWHP300R290\u003c\/strong\u003e is the flagship domestic model in the Becker \u0026amp; Wolf all-in-one heat pump water heater range — a \u003cstrong style=\"color: #1a3a5c;\"\u003e300-litre floor-standing unit\u003c\/strong\u003e for households of \u003cstrong style=\"color: #1a3a5c;\"\u003e5–6 people\u003c\/strong\u003e or high-demand properties. With 300 litres of hot water storage, it provides the largest available reservoir in the Becker \u0026amp; Wolf domestic lineup, ensuring that even high simultaneous demand — multiple showers, a bath, and kitchen use — is met without running cold. Using R290 (propane) refrigerant (GWP 3), it achieves a strong \u003cstrong style=\"color: #1a3a5c;\"\u003eErP A+ rating\u003c\/strong\u003e and delivers mains-pressure hot water up to 75°C. The integrated \u003cstrong style=\"color: #1a3a5c;\"\u003e150mm air duct collar\u003c\/strong\u003e allows the unit to be installed in a utility room or plant room with ducting to outside air, and the \u003cstrong style=\"color: #1a3a5c;\"\u003e2 kW backup electric heater\u003c\/strong\u003e guarantees hot water even during the coldest nights. Supplied with a complete \u003cstrong style=\"color: #1a3a5c;\"\u003eG3 safety kit and potable expansion vessel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"background: #e0f2fe; border-left: 4px solid #0e7490; border-radius: 0 6px 6px 0; padding: .9rem 1.2rem; margin: .9rem 0; font-size: 14.5px; line-height: 1.75; color: #1a3a5c;\"\u003eℹ️  \u003cstrong style=\"color: #1a3a5c;\"\u003eCapacity:\u003c\/strong\u003e 300 L   ·  \u003cstrong style=\"color: #1a3a5c;\"\u003eInstallation:\u003c\/strong\u003e Floor Standing  ·  \u003cstrong style=\"color: #1a3a5c;\"\u003eSuitable for:\u003c\/strong\u003e 5–6 persons\u003c\/p\u003e\n\u003cp style=\"background: #f0fdfb; border-left: 4px solid #0d9488; border-radius: 0 6px 6px 0; padding: .9rem 1.2rem; margin: .9rem 0; font-size: 14.5px; line-height: 1.75; color: #022c22;\"\u003eℹ️ \u003cstrong style=\"color: #1a3a5c;\"\u003eEstimated Recovery Time (Heat Pump Mode):\u003c\/strong\u003e Heating 300L of cold water from 15°C to 55°C at the rated hot water production of 90 L\/h takes approximately \u003cstrong style=\"color: #1a3a5c;\"\u003e200 minutes (~3.3 hours)\u003c\/strong\u003e under standard conditions (20°C ambient air). In \u003cstrong style=\"color: #1a3a5c;\"\u003eBoost \/ Electric Backup Mode\u003c\/strong\u003e (2 kW immersion), recovery takes approximately \u003cstrong style=\"color: #1a3a5c;\"\u003e418 minutes (~7.0 hours)\u003c\/strong\u003e independent of ambient temperature. Hot water production rate for 300L estimated at ~90 L\/h based on ErP XL cycle and scaled heating capacity; verify against official datasheet. In practice, the large 300L reserve means the unit can meet high peak demand without the heat pump needing to fully reheat from cold.\u003c\/p\u003e\n\u003cp style=\"font-size: 10.5px; font-weight: 800; letter-spacing: .15em; text-transform: uppercase; color: #0d9488; margin-top: 1.8rem; margin-bottom: .6rem; padding-bottom: 4px; border-bottom: 2px solid #0d9488;\"\u003eKey Features\u003c\/p\u003e\n\u003cul style=\"list-style: none; padding: 0; margin: 0 0 1.4rem 0;\"\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eR290 (propane) refrigerant\u003c\/strong\u003e — natural refrigerant with a GWP of just 3 and zero ODP; fully F-Gas regulation compliant and future-proofed against HFC phase-outs\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eAll-in-one design\u003c\/strong\u003e — compressor, microchannel heat exchanger, fan, and tank all in one compact unit; no separate outdoor unit, no refrigerant pipework between units, significantly simpler and faster to install than split-unit heat pumps\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eA+ Energy Efficiency\u003c\/strong\u003e rating under ErP Directive — up to 4× cheaper to run than a direct electric immersion heater\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eMax water temperature 75°C\u003c\/strong\u003e — high enough to meet UK Legionella control requirements; thermal disinfection cycle can be set from the control panel\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eBackup 2 kW electric immersion heater\u003c\/strong\u003e — integrated auxiliary element maintains hot water availability during extreme cold or periods of high demand; ensures DHW supply even when heat pump performance is reduced\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eWiFi smart control\u003c\/strong\u003e — compatible with the Becker \u0026amp; Wolf app (iOS \u0026amp; Android); monitor and adjust water temperature, operating mode, schedules, and energy usage remotely\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eMultiple operating modes\u003c\/strong\u003e — Heat Pump Only (most efficient), Auto (intelligently switches between modes), Boost (electric only, maximum recovery speed), Holiday mode, Timer schedules\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eMagnesium anode protection\u003c\/strong\u003e — extends inner tank life by preventing corrosion through sacrificial anode action; replaces standard corrosion protection additives\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eVertical top discharge\u003c\/strong\u003e — hot exhaust air exits via the top; suitable for indoor installation in utility rooms, loft spaces, garages, or plant rooms. Air duct connection available on floor-standing models (150mm diameter) for through-wall ducting\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eWorking temperature range –7°C to +43°C\u003c\/strong\u003e — operates year-round in UK conditions; auxiliary electric heater automatically activates if ambient temperature drops below the heat pump's effective range\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eIPX1 weather protection\u003c\/strong\u003e — suitable for installation in damp environments including garages and service areas\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eBecker \u0026amp; Wolf App\u003c\/strong\u003e — available on Apple App Store and Google Play; remote access for customers and installers including diagnostics and fault alerts\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eIncludes G3 kit and potable expansion vessel\u003c\/strong\u003e — G3 safety group (pressure reducing valve, expansion valve, check valve, pressure gauge, tundish) and compatible potable expansion vessel included; ready for direct mains connection\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003e150mm air duct connection\u003c\/strong\u003e — floor-standing models include a 150mm diameter duct collar at the top for connecting through-wall or ceiling ducting to exhaust warm\/humid air to the outside — particularly useful in sealed utility rooms\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eDN20 water connections\u003c\/strong\u003e — larger pipe connections suitable for higher flow rates matching the larger tank capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul style=\"list-style: none; padding: 0; margin: 0 0 1.4rem 0;\"\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003e300 litre tank — the largest domestic Becker \u0026amp; Wolf model\u003c\/strong\u003e — sufficient stored capacity for 5–6 persons; substantially reduces the frequency of full tank reheating cycles, maximising heat pump efficiency and compressor longevity\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eHighest heating capacity in the floor-standing range\u003c\/strong\u003e — provides the fastest recovery of any domestic Becker \u0026amp; Wolf model\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eErP XL tapping cycle\u003c\/strong\u003e — the most demanding ErP test profile, reflecting the unit's suitability for large families and higher daily hot water draw patterns\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eIdeal for properties converting from large gas boiler DHW cylinders\u003c\/strong\u003e — 300L matches or exceeds the stored capacity of most traditional vented and unvented hot water cylinders\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 10.5px; font-weight: 800; letter-spacing: .15em; text-transform: uppercase; color: #0d9488; margin-top: 1.8rem; margin-bottom: .6rem; padding-bottom: 4px; border-bottom: 2px solid #0d9488;\"\u003eTechnical Specifications\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 1.5rem;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 13.5px; min-width: 340px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"background: #1a3a5c; color: #ffffff; font-weight: bold; text-align: left; padding: 8px 12px; font-size: 13px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background: #1a3a5c; color: #ffffff; font-weight: bold; text-align: left; padding: 8px 12px; font-size: 13px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc; font-weight: 600; color: #1a3a5c;\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc;\"\u003eBWHP300R290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff; font-weight: 600; color: #1a3a5c;\"\u003eBarcode \/ EAN\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff;\"\u003e5061085070031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc; font-weight: 600; color: #1a3a5c;\"\u003eTank Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc;\"\u003e300 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff; font-weight: 600; color: #1a3a5c;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff;\"\u003eR290 (propane) — GWP 3, ODP 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc; font-weight: 600; color: #1a3a5c;\"\u003eEnergy Efficiency Class\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc;\"\u003eA+ (ErP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff; font-weight: 600; color: #1a3a5c;\"\u003eTapping Cycle (ErP)\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff;\"\u003eXL (extra large)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc; font-weight: 600; color: #1a3a5c;\"\u003eAux. Electric Heater\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc;\"\u003e2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff; font-weight: 600; color: #1a3a5c;\"\u003eDefault Water Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff;\"\u003e55°C (adjustable up to 75°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc; font-weight: 600; color: #1a3a5c;\"\u003eWorking Ambient Range\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc;\"\u003e–7°C to +43°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff; font-weight: 600; color: #1a3a5c;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff;\"\u003e220–240 V \/ 1-phase \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc; font-weight: 600; color: #1a3a5c;\"\u003eAir Flow Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc;\"\u003e450 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff; font-weight: 600; color: #1a3a5c;\"\u003eAir Discharge Direction\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff;\"\u003eVertical (upward)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc; font-weight: 600; color: #1a3a5c;\"\u003eAir Duct Diameter\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc;\"\u003e150 mm (duct collar fitted as standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff; font-weight: 600; color: #1a3a5c;\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff;\"\u003e48 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc; font-weight: 600; color: #1a3a5c;\"\u003eIP Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc;\"\u003eIPX1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff; font-weight: 600; color: #1a3a5c;\"\u003eWater Pipe Connections\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff;\"\u003eDN20 (¾\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc; font-weight: 600; color: #1a3a5c;\"\u003eInstallation Type\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #f8fafc;\"\u003eFloor Standing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff; font-weight: 600; color: #1a3a5c;\"\u003eSuitable for\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px; border-bottom: 1px solid #e2e8f0; vertical-align: top; background: #ffffff;\"\u003e5–6 persons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"background: #fffbeb; border-left: 4px solid #b45309; border-radius: 0 6px 6px 0; padding: .9rem 1.2rem; margin: .9rem 0; font-size: 14.5px; line-height: 1.75; color: #4a2800;\"\u003e⚠️ Full technical specifications (rated heating capacity kW, exact COP, dimensions, net\/gross weight) for the BWHP300R290 are detailed in the manufacturer's datasheet at beckerwolf.com. As the flagship domestic model the 300L has the largest dimensions in the range; ensure adequate space (min Φ~620mm footprint, ~1.8–1.9m height) is available before ordering.\u003c\/p\u003e\n\u003cp style=\"font-size: 10.5px; font-weight: 800; letter-spacing: .15em; text-transform: uppercase; color: #0d9488; margin-top: 1.8rem; margin-bottom: .6rem; padding-bottom: 4px; border-bottom: 2px solid #0d9488;\"\u003eWhat's Included\u003c\/p\u003e\n\u003cul style=\"list-style: none; padding: 0; margin: 0 0 1.4rem 0;\"\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003eBWHP300R290 300L floor-standing heat pump water heater unit\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003eG3 safety group kit (pressure reducing valve, expansion relief valve, check valve, pressure gauge, tundish)\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003ePotable expansion vessel\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003eMagnesium anode\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003eInstallation and user manual\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003eBecker \u0026amp; Wolf WiFi module\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e150mm air duct collar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 10.5px; font-weight: 800; letter-spacing: .15em; text-transform: uppercase; color: #0d9488; margin-top: 1.8rem; margin-bottom: .6rem; padding-bottom: 4px; border-bottom: 2px solid #0d9488;\"\u003eInstallation Notes\u003c\/p\u003e\n\u003cul style=\"list-style: none; padding: 0; margin: 0 0 1.4rem 0;\"\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eInstallation by a qualified heating engineer is mandatory.\u003c\/strong\u003e F-Gas \/ REFCOM certification required for refrigerant\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eFloor loading:\u003c\/strong\u003e At full capacity, the 300L tank + unit weight is considerable — ensure the floor can support the combined load. Consult a structural engineer if uncertain about floor loading capacity\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eMinimum room size: ~15–20 m³\u003c\/strong\u003e for open-room installation without ducting; smaller rooms should use the 150mm duct to outside\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003e150mm air duct:\u003c\/strong\u003e Connect through-wall to draw from or exhaust to outside; reduces the impact on room temperature and allows installation in smaller spaces\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eElectrical:\u003c\/strong\u003e Dedicated single-phase 230V circuit; 16A MCB with RCD protection; ensure circuit cabling is rated for full boost current\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eWater connections:\u003c\/strong\u003e DN20 (¾\"); G3 safety group on cold water supply; potable expansion vessel on cold supply side\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eCondensate drain:\u003c\/strong\u003e Required — plan adequate drainage\u003c\/li\u003e\n\u003cli style=\"padding: 5px 0 5px 24px; position: relative; font-size: 14.5px; line-height: 1.7;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; color: #0d9488; font-weight: 800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eLevelling:\u003c\/strong\u003e Critical for correct refrigerant circuit operation; use adjustable feet if available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 10.5px; font-weight: 800; letter-spacing: .15em; text-transform: uppercase; color: #0d9488; margin-top: 1.8rem; margin-bottom: .6rem; padding-bottom: 4px; border-bottom: 2px solid #0d9488;\"\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cdiv style=\"border-top: 2px solid #e2e8f0; margin-bottom: 1.5rem;\"\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e2e8f0; padding: .9rem 0 .9rem 1.5rem; position: relative;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: .9rem; color: #0d9488; font-weight: 900; font-size: 15px;\"\u003eQ\u003c\/span\u003e\n\u003cp style=\"font-weight: bold; color: #1a3a5c; font-size: 14.5px; margin: 0 0 .3rem 0;\"\u003eCan this heat pump replace my gas boiler for hot water?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #374151; line-height: 1.75; margin: 0;\"\u003eYes — the Becker \u0026amp; Wolf all-in-one heat pump is designed as a direct replacement for gas water heaters and combi boiler DHW. It provides mains-pressure hot water independently of any boiler. You will need a suitable indoor space (minimum ~5–8m³ for wall-mounted, ~10–15m³ for floor-standing) with sufficient ventilation or air duct connection. An F-Gas or REFCOM qualified engineer must handle the refrigerant if the unit ever needs regassing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e2e8f0; padding: .9rem 0 .9rem 1.5rem; position: relative;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: .9rem; color: #0d9488; font-weight: 900; font-size: 15px;\"\u003eQ\u003c\/span\u003e\n\u003cp style=\"font-weight: bold; color: #1a3a5c; font-size: 14.5px; margin: 0 0 .3rem 0;\"\u003eWhat ambient temperature does the heat pump work at?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #374151; line-height: 1.75; margin: 0;\"\u003eThe heat pump operates in ambient air temperatures from \u003cstrong style=\"color: #1a3a5c;\"\u003e–7°C to +43°C\u003c\/strong\u003e. Below about 5°C, COP reduces; the integrated 2 kW electric backup heater automatically activates at low temperatures to maintain the set water temperature. In practice, most UK installations operate efficiently throughout the year.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e2e8f0; padding: .9rem 0 .9rem 1.5rem; position: relative;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: .9rem; color: #0d9488; font-weight: 900; font-size: 15px;\"\u003eQ\u003c\/span\u003e\n\u003cp style=\"font-weight: bold; color: #1a3a5c; font-size: 14.5px; margin: 0 0 .3rem 0;\"\u003eDoes it need an outdoor unit?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #374151; line-height: 1.75; margin: 0;\"\u003e\u003cstrong style=\"color: #1a3a5c;\"\u003eNo\u003c\/strong\u003e — this is a self-contained all-in-one unit. The heat pump compressor, heat exchanger, fan, and storage tank are all integrated in one unit. There is no separate outdoor unit and no refrigerant pipework to run between two units. The unit draws heat from the room air and can be installed entirely indoors, optionally ducted to draw or exhaust air through an external wall.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e2e8f0; padding: .9rem 0 .9rem 1.5rem; position: relative;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: .9rem; color: #0d9488; font-weight: 900; font-size: 15px;\"\u003eQ\u003c\/span\u003e\n\u003cp style=\"font-weight: bold; color: #1a3a5c; font-size: 14.5px; margin: 0 0 .3rem 0;\"\u003eWhat room size does this need for installation?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #374151; line-height: 1.75; margin: 0;\"\u003eAs a rough guide: \u003cstrong style=\"color: #1a3a5c;\"\u003ewall-mounted 80L\/100L\u003c\/strong\u003e units need a minimum space of approximately 5–8m³; \u003cstrong style=\"color: #1a3a5c;\"\u003efloor-standing 200–300L\u003c\/strong\u003e units need approximately 10–20m³. The heat pump extracts heat from the surrounding air — too small a space will cause the room to cool too quickly, reducing efficiency. Alternatively, connect a 150mm air duct (floor-standing models) to draw from or exhaust to outside air, allowing installation in smaller spaces.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e2e8f0; padding: .9rem 0 .9rem 1.5rem; position: relative;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: .9rem; color: #0d9488; font-weight: 900; font-size: 15px;\"\u003eQ\u003c\/span\u003e\n\u003cp style=\"font-weight: bold; color: #1a3a5c; font-size: 14.5px; margin: 0 0 .3rem 0;\"\u003eIs this MCS certified?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #374151; line-height: 1.75; margin: 0;\"\u003eThe Becker \u0026amp; Wolf heat pump water heaters are A+ ErP-rated and CE certified. Please check with Quality Heating \/ your installer regarding current MCS certification status for eligibility for any available UK government grants or incentive schemes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e2e8f0; padding: .9rem 0 .9rem 1.5rem; position: relative;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: .9rem; color: #0d9488; font-weight: 900; font-size: 15px;\"\u003eQ\u003c\/span\u003e\n\u003cp style=\"font-weight: bold; color: #1a3a5c; font-size: 14.5px; margin: 0 0 .3rem 0;\"\u003eWhat is the Legionella control cycle?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #374151; line-height: 1.75; margin: 0;\"\u003eThe Becker \u0026amp; Wolf units can reach \u003cstrong style=\"color: #1a3a5c;\"\u003e75°C\u003c\/strong\u003e, sufficient for thermal disinfection of the tank to control Legionella bacteria. A periodic disinfection cycle can be scheduled via the Becker \u0026amp; Wolf app or the control panel. UK guidance recommends domestic hot water systems store water at 60°C or above to control Legionella risk.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e2e8f0; padding: .9rem 0 .9rem 1.5rem; position: relative;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: .9rem; color: #0d9488; font-weight: 900; font-size: 15px;\"\u003eQ\u003c\/span\u003e\n\u003cp style=\"font-weight: bold; color: #1a3a5c; font-size: 14.5px; margin: 0 0 .3rem 0;\"\u003eCan it be connected to solar PV?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #374151; line-height: 1.75; margin: 0;\"\u003eYes — the unit can be timed or configured to run primarily during daylight hours when solar PV generation is highest, reducing running costs further. Integration with solar divert controllers (such as Eddi, Zappi, or similar) is possible by scheduling the boost\/immersion mode via the app or an external timer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e2e8f0; padding: .9rem 0 .9rem 1.5rem; position: relative;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: .9rem; color: #0d9488; font-weight: 900; font-size: 15px;\"\u003eQ\u003c\/span\u003e\n\u003cp style=\"font-weight: bold; color: #1a3a5c; font-size: 14.5px; margin: 0 0 .3rem 0;\"\u003eIs the 300L the right size for my property?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #374151; line-height: 1.75; margin: 0;\"\u003eThe BWHP300R290 is designed for \u003cstrong style=\"color: #1a3a5c;\"\u003e5–6 person households\u003c\/strong\u003e or properties with high peak hot water demand. As a guide: at approximately 50L per person per day, 300L provides roughly one day's hot water storage at full capacity. If you regularly run out of hot water in the morning peak with a smaller cylinder, or have multiple bathrooms in simultaneous use, the 300L is the right choice. For smaller households, the 200L or 250L models are likely sufficient and more economical.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e2e8f0; padding: .9rem 0 .9rem 1.5rem; position: relative;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: .9rem; color: #0d9488; font-weight: 900; font-size: 15px;\"\u003eQ\u003c\/span\u003e\n\u003cp style=\"font-weight: bold; color: #1a3a5c; font-size: 14.5px; margin: 0 0 .3rem 0;\"\u003eHow does the 300L compare to a traditional 300L unvented cylinder with an immersion heater?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #374151; line-height: 1.75; margin: 0;\"\u003eA traditional 300L direct cylinder with a 3kW immersion heater uses 3kW to produce 3kW of heat (COP = 1). The BWHP300R290 uses approximately 700–900W (in heat pump mode at 20°C ambient) to produce the equivalent of ~2.8kW of heat — effectively \u003cstrong style=\"color: #1a3a5c;\"\u003e3–4× cheaper to run\u003c\/strong\u003e per kWh of hot water produced. The trade-off is longer recovery time in heat pump mode vs the immersion's brute-force speed; the 2kW backup element is available for urgent recovery when needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-bottom: 1px solid #e2e8f0; padding: .9rem 0 .9rem 1.5rem; position: relative;\"\u003e\n\u003cspan style=\"position: absolute; left: 0; top: .9rem; color: #0d9488; font-weight: 900; font-size: 15px;\"\u003eQ\u003c\/span\u003e\n\u003cp style=\"font-weight: bold; color: #1a3a5c; font-size: 14.5px; margin: 0 0 .3rem 0;\"\u003eCan two units be installed for very high demand?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #374151; line-height: 1.75; margin: 0;\"\u003eYes — if a single 300L unit is insufficient (for example, in an HMO or small holiday let with 7+ occupants), two Becker \u0026amp; Wolf units can be installed on a shared hot water circuit with appropriate anti-scalding and balancing measures. Contact Becker \u0026amp; Wolf's technical team or Quality Heating for system design advice.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Becker \u0026 Wolf","offers":[{"title":"Default Title","offer_id":62926268498269,"sku":"BWHP300R290","price":1770.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/BeckerandWolfBWHP300R290FloorStanding300LHotWaterHeatpump1.jpg?v=1766488195","url":"https:\/\/qualityheating.co.uk\/products\/becker-and-wolf-floor-standing-300l-hot-water-heat-pump-r290","provider":"AIZO Quality Heating","version":"1.0","type":"link"}