{"product_id":"baxi-usense-2-gateway-power-adapter-kit","title":"Baxi uSense 2 Gateway \u0026 Power Adapter Kit","description":"\u003cdiv style=\"font-size:16px;line-height:1.65;color:#2a2a2a;font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',Roboto,Helvetica,Arial,sans-serif;max-width:900px;margin:0 auto;\"\u003e\n\u003cp style=\"font-size:1.05em;margin:0 0 18px;\"\u003eThe \u003cstrong\u003eBaxi uSense 2 Gateway \u0026amp; Power Adapter Kit (MPN 7822453)\u003c\/strong\u003e is the wiring bridge between a \u003cstrong\u003eBaxi uSense 2 Wired Smart Room Thermostat (7775937)\u003c\/strong\u003e and any Baxi appliance that doesn't connect to it directly — including \u003cstrong\u003eBaxi air source heat pumps\u003c\/strong\u003e and \u003cstrong\u003eolder Baxi, Potterton and Main combi boilers\u003c\/strong\u003e. The kit supplies \u003cstrong\u003e24 V power\u003c\/strong\u003e to the gateway, and the gateway in turn provides \u003cstrong\u003eOpenTherm\u003c\/strong\u003e, \u003cstrong\u003eRBUS\u003c\/strong\u003e and \u003cstrong\u003e230 V switched-live\u003c\/strong\u003e connection options to the appliance.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 22px;\"\u003eIn a \u003cstrong\u003emulti-zone installation\u003c\/strong\u003e you need \u003cstrong\u003eone gateway plus one uSense 2 per zone\u003c\/strong\u003e, so the kit also expands the system's zoning capability beyond a single room.\u003c\/p\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(4,1fr);gap:10px;margin:0 0 28px;\"\u003e\n\u003cdiv style=\"background:#008377CF;color:#ffffff;padding:18px 12px;border-radius:8px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.45em;font-weight:700;line-height:1.1;\"\u003e3-in-1\u003c\/div\u003e\n\u003cdiv style=\"font-size:.85em;opacity:.95;margin-top:4px;\"\u003eOpenTherm · RBUS · 230 V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF;color:#ffffff;padding:18px 12px;border-radius:8px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.45em;font-weight:700;line-height:1.1;\"\u003e24 V\u003c\/div\u003e\n\u003cdiv style=\"font-size:.85em;opacity:.95;margin-top:4px;\"\u003ePower output\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF;color:#ffffff;padding:18px 12px;border-radius:8px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.45em;font-weight:700;line-height:1.1;\"\u003e50 m\u003c\/div\u003e\n\u003cdiv style=\"font-size:.85em;opacity:.95;margin-top:4px;\"\u003eMax thermostat distance\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF;color:#ffffff;padding:18px 12px;border-radius:8px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.45em;font-weight:700;line-height:1.1;\"\u003eZone-ready\u003c\/div\u003e\n\u003cdiv style=\"font-size:.85em;opacity:.95;margin-top:4px;\"\u003e1 kit per zone\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#e6f4f3;border-left:4px solid #008377CF;padding:14px 18px;margin:0 0 22px;border-radius:4px;\"\u003e\n\u003cstrong style=\"color:#005c54;\"\u003eRequired for heat pumps and most older combis.\u003c\/strong\u003e You \u003cstrong\u003edo not need this kit\u003c\/strong\u003e for the newer Baxi 200 \/ 400 \/ 600 \/ 800 Combi 2, the Assure 500 Combi 2, or the Baxi Split ASHP — those connect directly to the uSense 2. \u003cstrong\u003eEverything else does.\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"background:#008377CF;color:#ffffff;padding:12px 18px;margin:28px 0 16px;border-radius:6px;font-size:1.15em;font-weight:600;letter-spacing:.2px;\"\u003eKey features\u003c\/h3\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(2,1fr);gap:14px;margin:0 0 24px;\"\u003e\n\u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:8px;padding:16px 18px;\"\u003e\n\u003ch4 style=\"margin:0 0 8px;color:#005c54;font-size:1.02em;font-weight:600;\"\u003eThree connection options\u003c\/h4\u003e\n\u003cp style=\"margin:0;font-size:.95em;line-height:1.55;\"\u003eGateway terminals support \u003cstrong\u003eOpenTherm (OT)\u003c\/strong\u003e for modulating control, \u003cstrong\u003eRBUS\u003c\/strong\u003e for native Baxi connection, and \u003cstrong\u003e230 V switched-live (ON\/OFF)\u003c\/strong\u003e for legacy applications — pick whichever your appliance supports.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:8px;padding:16px 18px;\"\u003e\n\u003ch4 style=\"margin:0 0 8px;color:#005c54;font-size:1.02em;font-weight:600;\"\u003eMulti-zone enabler\u003c\/h4\u003e\n\u003cp style=\"margin:0;font-size:.95em;line-height:1.55;\"\u003eEach gateway + uSense 2 acts as an \u003cstrong\u003eindependent heating zone\u003c\/strong\u003e. Add as many as the system has zones — every one shows up separately in the Baxi Thermostat app.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:8px;padding:16px 18px;\"\u003e\n\u003ch4 style=\"margin:0 0 8px;color:#005c54;font-size:1.02em;font-weight:600;\"\u003ePower adapter included\u003c\/h4\u003e\n\u003cp style=\"margin:0;font-size:.95em;line-height:1.55;\"\u003eComes with the \u003cstrong\u003e24 V power adapter\u003c\/strong\u003e that runs the gateway, plus an adhesive mounting pad for tidy installation. The adapter must be sited \u003cstrong\u003eoutside the appliance casing\u003c\/strong\u003e, not within it.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:8px;padding:16px 18px;\"\u003e\n\u003ch4 style=\"margin:0 0 8px;color:#005c54;font-size:1.02em;font-weight:600;\"\u003eOpenTherm boiler-side modulation\u003c\/h4\u003e\n\u003cp style=\"margin:0;font-size:.95em;line-height:1.55;\"\u003eOn OpenTherm-connected boilers the gateway forwards modulating commands so the uSense 2 controls \u003cstrong\u003eflow temperature and burner output\u003c\/strong\u003e, not just on\/off — better efficiency and smoother room temperatures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:8px;padding:16px 18px;\"\u003e\n\u003ch4 style=\"margin:0 0 8px;color:#005c54;font-size:1.02em;font-weight:600;\"\u003eBoiler Plus compliant pairing\u003c\/h4\u003e\n\u003cp style=\"margin:0;font-size:.95em;line-height:1.55;\"\u003eWith the gateway connecting via \u003cstrong\u003eOpenTherm or RBUS\u003c\/strong\u003e, the uSense 2 satisfies \u003cstrong\u003eBoiler Plus\u003c\/strong\u003e on combi installations — no extra weather-compensation kit needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:8px;padding:16px 18px;\"\u003e\n\u003ch4 style=\"margin:0 0 8px;color:#005c54;font-size:1.02em;font-weight:600;\"\u003ePolarity-free thermostat wiring\u003c\/h4\u003e\n\u003cp style=\"margin:0;font-size:.95em;line-height:1.55;\"\u003eThe low-voltage line between the gateway and the uSense 2 room unit is \u003cstrong\u003epolarity-free\u003c\/strong\u003e — either wire to either terminal — making installation faster and harder to get wrong.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff8e1;border-left:4px solid #f59e0b;padding:14px 18px;margin:0 0 22px;border-radius:4px;\"\u003e\n\u003cstrong style=\"color:#92400e;\"\u003eQualified installer only.\u003c\/strong\u003e The gateway side connects to \u003cstrong\u003emains 230 V\u003c\/strong\u003e. Live, neutral, earth, common and switched-live must be identified correctly before connection. Incorrect wiring will damage the room unit and gateway, and may invalidate the appliance's warranty. Connect \u003cstrong\u003e230 V to the OpenTherm or low-voltage terminals will destroy the kit\u003c\/strong\u003e.\u003c\/div\u003e\n\u003ch3 style=\"background:#008377CF;color:#ffffff;padding:12px 18px;margin:28px 0 16px;border-radius:6px;font-size:1.15em;font-weight:600;letter-spacing:.2px;\"\u003eWhen is the gateway required?\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;margin:0 0 24px;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#008377CF;color:#ffffff;\"\u003e\n\u003cth style=\"padding:11px 12px;text-align:left;\"\u003eAppliance range\u003c\/th\u003e\n\u003cth style=\"padding:11px 12px;text-align:center;\"\u003eGateway needed?\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;\"\u003eBaxi 200 \/ 400 \/ 600 \/ 800 Combi 2\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;text-align:center;color:#005c54;\"\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;\"\u003eBaxi Assure 500 Combi 2\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;text-align:center;color:#005c54;\"\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;\"\u003eBaxi Split ASHP (heat pump)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;text-align:center;color:#005c54;\"\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;\"\u003eMain Eco Compact (Combi)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;text-align:center;color:#005c54;\"\u003e\u003cstrong\u003eRequired\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;\"\u003eAll other Baxi, Potterton \u0026amp; Main combi ranges\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;text-align:center;color:#005c54;\"\u003e\u003cstrong\u003eRequired\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;\"\u003eBaxi Assure Mono ASHP (heat pump)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;text-align:center;color:#005c54;\"\u003e\u003cstrong\u003eRequired\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;\"\u003eBaxi HP40 Mono 2 AWHP (heat pump)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;text-align:center;color:#005c54;\"\u003e\u003cstrong\u003eRequired\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;\"\u003eBaxi Assure HP50 Mono 2 AWHP (heat pump)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;text-align:center;color:#005c54;\"\u003e\u003cstrong\u003eRequired\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;\"\u003eMulti-zone systems (any compatible appliance)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 12px;border-bottom:1px solid #e8e8e8;text-align:center;color:#005c54;\"\u003e\u003cstrong\u003eRequired — one per zone\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"background:#008377CF;color:#ffffff;padding:12px 18px;margin:28px 0 16px;border-radius:6px;font-size:1.15em;font-weight:600;letter-spacing:.2px;\"\u003eTechnical specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;margin:0 0 24px;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:.95em;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;font-weight:600;color:#005c54;width:42%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;\"\u003eBaxi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;font-weight:600;color:#005c54;width:42%;\"\u003eMPN\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;\"\u003e7822453\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;font-weight:600;color:#005c54;width:42%;\"\u003eProduct\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;\"\u003eGateway \u0026amp; Power Adapter Kit for the Baxi uSense 2 Smart Room Thermostat (7775937)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;font-weight:600;color:#005c54;width:42%;\"\u003eConnection options to appliance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;\"\u003eOpenTherm, RBUS, 230 V switched-live (ON\/OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;font-weight:600;color:#005c54;width:42%;\"\u003ePower adapter output\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;font-weight:600;color:#005c54;width:42%;\"\u003eMains input\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;\"\u003e230 V (live + neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;font-weight:600;color:#005c54;width:42%;\"\u003eMax distance to room unit\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;\"\u003e50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;font-weight:600;color:#005c54;width:42%;\"\u003ePolarity (room-unit cable)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;\"\u003eNone — either wire to either terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;font-weight:600;color:#005c54;width:42%;\"\u003eDefault OpenTherm settings\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;\"\u003eCH flow 80 °C, DHW 60 °C (adjustable from uSense 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;font-weight:600;color:#005c54;width:42%;\"\u003eIn the box\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;\"\u003eGateway · 24 V power adapter · adhesive mounting pad · installation guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;font-weight:600;color:#005c54;width:42%;\"\u003eCompanion product\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;\"\u003eBaxi uSense 2 Wired Smart Room Thermostat (sold separately, MPN 7775937)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;font-weight:600;color:#005c54;width:42%;\"\u003eInstallation\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e8e8e8;\"\u003eBy a qualified electrician or heating engineer only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"background:#008377CF;color:#ffffff;padding:12px 18px;margin:28px 0 16px;border-radius:6px;font-size:1.15em;font-weight:600;letter-spacing:.2px;\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cdetails style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;margin:0 0 8px;padding:0;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;cursor:pointer;font-weight:600;border-radius:6px 6px 0 0;list-style:none;\"\u003eDo I definitely need this kit?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px;\"\u003eOnly for certain appliances. The newer Baxi 200 \/ 400 \/ 600 \/ 800 Combi 2, the Assure 500 Combi 2 and the Baxi Split ASHP connect \u003cstrong\u003edirectly\u003c\/strong\u003e to the uSense 2 — no gateway required. \u003cstrong\u003eAll other Baxi, Potterton and Main combis, plus the Baxi Mono ASHP \/ HP40 \/ HP50 heat pumps, do need the gateway.\u003c\/strong\u003e Multi-zone systems always need one per zone.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;margin:0 0 8px;padding:0;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;cursor:pointer;font-weight:600;border-radius:6px 6px 0 0;list-style:none;\"\u003eWhat's in the box?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px;\"\u003eThe \u003cstrong\u003egateway\u003c\/strong\u003e, a \u003cstrong\u003e24 V power adapter\u003c\/strong\u003e, an \u003cstrong\u003eadhesive mounting pad\u003c\/strong\u003e for the adapter, and the installation guide. The uSense 2 thermostat itself (7775937) is \u003cstrong\u003esold separately\u003c\/strong\u003e.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;margin:0 0 8px;padding:0;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;cursor:pointer;font-weight:600;border-radius:6px 6px 0 0;list-style:none;\"\u003eWhy do I need the power adapter?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px;\"\u003eThe gateway runs on 24 V DC. The supplied power adapter steps down 230 V mains to 24 V and feeds the gateway via a plug-in connector. Per Baxi's installation guide the adapter must be located \u003cstrong\u003eoutside the appliance casing\u003c\/strong\u003e, secured with the adhesive pad provided.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;margin:0 0 8px;padding:0;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;cursor:pointer;font-weight:600;border-radius:6px 6px 0 0;list-style:none;\"\u003eHow far can the thermostat be from the gateway?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px;\"\u003eUp to \u003cstrong\u003e50 m\u003c\/strong\u003e of cable run between the room unit and the gateway. The cable is low-voltage and polarity-free — either wire to either terminal.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;margin:0 0 8px;padding:0;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;cursor:pointer;font-weight:600;border-radius:6px 6px 0 0;list-style:none;\"\u003eCan I use it with a System or Heat-Only boiler?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px;\"\u003e\n\u003cstrong\u003eNo.\u003c\/strong\u003e The uSense 2 system, gateway included, is \u003cstrong\u003enot compatible with System or Heat-Only boilers\u003c\/strong\u003e. Use one of Baxi's programmable thermostats designed for those installations instead.\u003c\/div\u003e\u003c\/details\u003e\u003cdiv style=\"background:#008377CF;color:#ffffff;padding:18px 22px;border-radius:8px;margin:30px 0 0;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.05em;font-weight:600;margin-bottom:6px;\"\u003eDon't forget the thermostat\u003c\/div\u003e\n\u003cdiv style=\"font-size:.95em;opacity:.95;\"\u003eThis kit is the bridge — you also need the \u003cstrong\u003eBaxi uSense 2 Wired Smart Room Thermostat (MPN 7775937)\u003c\/strong\u003e. Order both for a complete installation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Baxi","offers":[{"title":"Default Title","offer_id":64567324836189,"sku":"7822453","price":77.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/BaxiuSense2Gateway_PowerAdapterKit7822453.webp?v=1777554924","url":"https:\/\/qualityheating.co.uk\/products\/baxi-usense-2-gateway-power-adapter-kit","provider":"AIZO Quality Heating","version":"1.0","type":"link"}