{"product_id":"baxi-430-combi-2-1-boiler-30kw-natural-gas-lpg","title":"Baxi 430 Combi 2.1 Boiler 30kW (Natural Gas\/LPG)","description":"\u003cdiv style=\"font-size: 16px; max-width: 900px; font-family: Arial, Helvetica, sans-serif; color: #2b2b2b; line-height: 1.6;\"\u003e\n\u003cp style=\"margin: 0 0 20px 0; line-height: 1.6; color: #2b2b2b;\"\u003eThe \u003cstrong\u003eBaxi 430 Combi 2.1\u003c\/strong\u003e is a 30kW high-efficiency condensing combi boiler engineered for medium-sized homes with up to two bathrooms. It combines instant hot water and central heating in one compact, wall-mounted unit, removing the need for a separate cylinder or tank. Built with a \u003cstrong\u003estainless steel heat exchanger\u003c\/strong\u003e and \u003cstrong\u003ebrass hydraulics\u003c\/strong\u003e, it runs on Natural Gas or LPG without a conversion kit, and is backed by a \u003cstrong\u003e5-year parts and labour warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; margin: 0 0 24px 0;\"\u003e\n\u003cdiv style=\"flex: 1 1 140px; min-width: 140px; background: #008377CF; border-radius: 8px; padding: 16px 10px; text-align: center; margin: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; line-height: 1.2; font-size: 20px; color: #ffffff;\"\u003e30kW\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; color: #e7f5f3; margin-top: 4px; line-height: 1.3;\"\u003eDHW Output\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 140px; min-width: 140px; background: #008377CF; border-radius: 8px; padding: 16px 10px; text-align: center; margin: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; line-height: 1.2; font-size: 20px; color: #ffffff;\"\u003e27.1kW\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; color: #e7f5f3; margin-top: 4px; line-height: 1.3;\"\u003eCH Output (Condensing)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 140px; min-width: 140px; background: #008377CF; border-radius: 8px; padding: 16px 10px; text-align: center; margin: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; line-height: 1.2; font-size: 20px; color: #ffffff;\"\u003eA Rated\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; color: #e7f5f3; margin-top: 4px; line-height: 1.3;\"\u003eErP Efficiency\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 140px; min-width: 140px; background: #008377CF; border-radius: 8px; padding: 16px 10px; text-align: center; margin: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; line-height: 1.2; font-size: 20px; color: #ffffff;\"\u003e12.2 L\/min\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; color: #e7f5f3; margin-top: 4px; line-height: 1.3;\"\u003eDHW Flow Rate\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 140px; min-width: 140px; background: #008377CF; border-radius: 8px; padding: 16px 10px; text-align: center; margin: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; line-height: 1.2; font-size: 20px; color: #ffffff;\"\u003e5 Years\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; color: #e7f5f3; margin-top: 4px; line-height: 1.3;\"\u003eParts \u0026amp; Labour Warranty\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 140px; min-width: 140px; background: #008377CF; border-radius: 8px; padding: 16px 10px; text-align: center; margin: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; line-height: 1.2; font-size: 20px; color: #ffffff;\"\u003e29kg\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; color: #e7f5f3; margin-top: 4px; line-height: 1.3;\"\u003eInstaller Lift Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left: 4px solid #C0392B; background: #FDEDEB; border-radius: 6px; padding: 14px 16px; margin: 0 0 20px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #9b2c1f; margin-bottom: 6px; font-size: 14px;\"\u003eInstallation must be by a Gas Safe registered engineer\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #2b2b2b;\"\u003eThis appliance must be installed, commissioned and serviced only by a Gas Safe registered engineer, in accordance with Building Regulations and the manufacturer's Installation and Service Manual. A Benchmark Commissioning Checklist must be completed on installation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left: 4px solid #B7791F; background: #FEF6E7; border-radius: 6px; padding: 14px 16px; margin: 0 0 20px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #8a5a10; margin-bottom: 6px; font-size: 14px;\"\u003eCable sizing is site-specific\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #2b2b2b;\"\u003eThe boiler requires a permanent electrical live supply. Actual cable sizing for the fixed electrical connection must be calculated by a qualified electrician in accordance with BS 7671, based on cable run length and installation method.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left: 4px solid #008377CF; background: #EAF6F4; border-radius: 6px; padding: 14px 16px; margin: 0 0 20px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #00594f; margin-bottom: 6px; font-size: 14px;\"\u003eDual fuel flexibility as standard\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #2b2b2b;\"\u003eThis boiler ships ready for \u003cstrong\u003eNatural Gas\u003c\/strong\u003e and can be manually converted to \u003cstrong\u003eLPG\u003c\/strong\u003e without needing a separate conversion kit, making it a practical choice for both mains-gas properties and off-grid installations.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 17px; color: #00594f; margin: 28px 0 12px 0;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; margin: 0 0 24px 0;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; min-width: 260px; background: #F7FBFA; border: 1px solid #E0EDEB; border-radius: 8px; padding: 16px; margin: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 8px; font-size: 15px;\"\u003eStainless Steel Heat Exchanger\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #2b2b2b;\"\u003eA fully stainless steel primary heat exchanger resists corrosion and scale build-up far better than aluminium alternatives, supporting long-term reliability in hard water areas.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; min-width: 260px; background: #F7FBFA; border: 1px solid #E0EDEB; border-radius: 8px; padding: 16px; margin: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 8px; font-size: 15px;\"\u003ePre-Heated Siphonic Condensate Trap\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #2b2b2b;\"\u003eThe condensate trap is pre-heated before discharge, significantly reducing the risk of the pipe freezing and locking the boiler out during cold winter spells.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; min-width: 260px; background: #F7FBFA; border: 1px solid #E0EDEB; border-radius: 8px; padding: 16px; margin: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 8px; font-size: 15px;\"\u003eBrass Hydraulic Block\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #2b2b2b;\"\u003eBrass hydraulics replace lower-grade plastics at key water-carrying junctions, improving durability under the pressure cycling combi boilers experience during frequent hot water draw-off.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; min-width: 260px; background: #F7FBFA; border: 1px solid #E0EDEB; border-radius: 8px; padding: 16px; margin: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 8px; font-size: 15px;\"\u003eCombined PRV with Separate Drain\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #2b2b2b;\"\u003eThe pressure relief valve routes to its own dedicated drain point, allowing a faster and safer boiler drain-down for repairs without disturbing the main condensate route.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; min-width: 260px; background: #F7FBFA; border: 1px solid #E0EDEB; border-radius: 8px; padding: 16px; margin: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 8px; font-size: 15px;\"\u003eExternal Analogue Pressure Gauge\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #2b2b2b;\"\u003eA visible external gauge lets homeowners check and top up system pressure themselves, reducing avoidable engineer call-outs for simple low-pressure faults.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; min-width: 260px; background: #F7FBFA; border: 1px solid #E0EDEB; border-radius: 8px; padding: 16px; margin: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 8px; font-size: 15px;\"\u003eAmbizen and uSense 2 Smart Control Compatible\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #2b2b2b;\"\u003ePairing with the Baxi Ambizen or uSense 2 Smart Room Thermostat unlocks an A+ central heating efficiency rating and remote schedule control from a smartphone app.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 17px; color: #00594f; margin: 28px 0 12px 0;\"\u003eTechnical Specification\u003c\/div\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 0 0 24px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 12px; font-size: 14px;\"\u003ePerformance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #F7FBFA;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eMax DHW Output\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e30 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FFFFFF;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eMax CH Output (Condensing)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e27.1 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #F7FBFA;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eMin CH Output (Condensing)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e6.3 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FFFFFF;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eMax CH Output (Non-Condensing)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e25 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #F7FBFA;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eMax Gas Rate (Natural Gas, G20)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e3.26 m³\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FFFFFF;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eWater Heating Efficiency Class\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #F7FBFA;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eCentral Heating Efficiency (with uSense 2)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003eA+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FFFFFF;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eSAP 2009 Efficiency\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e94%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 12px; font-size: 14px;\"\u003eHydraulic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #F7FBFA;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eMax DHW Flow Rate (ΔT 35°C)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e12.2 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FFFFFF;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eMin DHW Flow Rate Required\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e2 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #F7FBFA;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eMin Operating DHW Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e0.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FFFFFF;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eIntegral Expansion Vessel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e7 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #F7FBFA;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eMax CH System Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e100 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FFFFFF;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eIntegral Automatic Bypass\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 12px; font-size: 14px;\"\u003eGas \u0026amp; Electrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #F7FBFA;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eFuel Type\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003eNatural Gas or LPG (manual conversion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FFFFFF;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eInlet Supply Pressure (Natural Gas)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e20 mbar nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #F7FBFA;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003ePermanent Live Required\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FFFFFF;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eExternal Fuse Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003eF0.5A L250VP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #F7FBFA;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003ePump Overrun\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FFFFFF;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eIntegral Frost Thermostat\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 12px; font-size: 14px;\"\u003eDimensions \u0026amp; Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #F7FBFA;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e700 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FFFFFF;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e395 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #F7FBFA;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e285 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FFFFFF;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eInstaller Lift Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #F7FBFA;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eMinimum Side Clearance\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e2.5 mm (min recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 12px; font-size: 14px;\"\u003eWarranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #F7FBFA;\"\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB; width: 55%;\"\u003eParts \u0026amp; Labour\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; color: #2b2b2b; border-bottom: 1px solid #E0EDEB;\"\u003e5 Years (subject to manufacturer's T\u0026amp;Cs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 17px; color: #00594f; margin: 28px 0 12px 0;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 24px 0;\"\u003e\n\u003cdetails style=\"margin: 0 0 10px 0; border: 1px solid #E0EDEB; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 16px; cursor: pointer; font-size: 14px; list-style: none;\"\u003eIs the Baxi 430 Combi 2.1 suitable for a 2-bathroom home?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; font-size: 14px; line-height: 1.6; color: #2b2b2b; background: #FFFFFF;\"\u003eYes. With a 30kW DHW output and 12.2 L\/min flow rate at 35°C rise, it is designed for medium-sized homes with up to two bathrooms and moderate simultaneous hot water demand.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin: 0 0 10px 0; border: 1px solid #E0EDEB; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 16px; cursor: pointer; font-size: 14px; list-style: none;\"\u003eCan this boiler run on LPG?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; font-size: 14px; line-height: 1.6; color: #2b2b2b; background: #FFFFFF;\"\u003eYes. The Baxi 430 Combi 2.1 is certified for both \u003cstrong\u003eNatural Gas and LPG\u003c\/strong\u003e and can be manually converted between the two without needing a separate conversion kit.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin: 0 0 10px 0; border: 1px solid #E0EDEB; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 16px; cursor: pointer; font-size: 14px; list-style: none;\"\u003eDoes it fit in a standard kitchen cupboard?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; font-size: 14px; line-height: 1.6; color: #2b2b2b; background: #FFFFFF;\"\u003eAt 700mm (H) x 395mm (W) x 285mm (D), the boiler is compact enough to fit within a 290mm deep cupboard, making it suitable for space-restricted installations.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin: 0 0 10px 0; border: 1px solid #E0EDEB; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 16px; cursor: pointer; font-size: 14px; list-style: none;\"\u003eWhat is the warranty on this boiler?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; font-size: 14px; line-height: 1.6; color: #2b2b2b; background: #FFFFFF;\"\u003eThe Baxi 430 Combi 2.1 comes with a \u003cstrong\u003e5-year parts and labour warranty\u003c\/strong\u003e, subject to registration and an annual service by a Gas Safe registered engineer.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin: 0 0 10px 0; border: 1px solid #E0EDEB; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 16px; cursor: pointer; font-size: 14px; list-style: none;\"\u003eIs a smart thermostat required?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; font-size: 14px; line-height: 1.6; color: #2b2b2b; background: #FFFFFF;\"\u003eNo, but pairing the boiler with the \u003cstrong\u003eBaxi Ambizen or uSense 2 Smart Room Thermostat\u003c\/strong\u003e raises the central heating efficiency rating from A to A+ and adds remote scheduling.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Baxi","offers":[{"title":"Default Title","offer_id":65218789540189,"sku":"7872836","price":835.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Baxi-400-Combi-2.1-NG-or-LPG-Boiler.jpg?v=1783688218","url":"https:\/\/qualityheating.co.uk\/products\/baxi-430-combi-2-1-boiler-30kw-natural-gas-lpg","provider":"AIZO Quality Heating","version":"1.0","type":"link"}