{"product_id":"ariston-standard-horizontal-flue-kit-60-100mm-3318073-he-condensing-boiler-through-wall-coaxial-flue","title":"Ariston Standard Horizontal Flue Kit 60\/100mm 3318073 – HE Condensing Boiler Through-Wall Coaxial Flue","description":"\u003c!-- SEO Product Name: Ariston Standard Horizontal Flue Kit 60\/100mm 3318073 – HE Condensing Boiler Through-Wall Coaxial Flue --\u003e\n\u003cdiv style=\"font-size:16px;font-family:Arial,sans-serif;color:#222;max-width:900px;margin:0 auto;line-height:1.6;\"\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eAriston Standard Horizontal Flue Kit Ø60\/100mm (Part No. 3318073)\u003c\/strong\u003e is the \u003cstrong\u003emost common flue accessory for Ariston HE condensing boilers\u003c\/strong\u003e — a complete \u003cstrong\u003ethrough-wall coaxial horizontal termination assembly\u003c\/strong\u003e for the \u003cstrong\u003eE-Combi ONE, Clas ONE, Clas System ONE, Genus ONE, Alteas ONE, Alteas ONE+ NET, and E-System ONE\u003c\/strong\u003e ranges. The \u003cstrong\u003e1000mm overall length\u003c\/strong\u003e accommodates most standard domestic wall thicknesses in a straightforward straight-through installation, and the \u003cstrong\u003epush-fit coaxial construction\u003c\/strong\u003e — where combustion gases exhaust through the inner pipe while fresh combustion air enters through the outer annulus — eliminates the need for separate flue and air supply terminations at the wall face. Supplied as a complete set including all components needed for a standard horizontal installation. Also available bundled with the \u003cstrong\u003eVertical Starter (3318079) as Part No. 3318074\u003c\/strong\u003e — useful where the installer wants both flue route options to hand on site.\u003c\/p\u003e\n\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0;\"\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;border-radius:8px;padding:14px 18px;flex:1 1 130px;text-align:center;\"\u003e\n    \u003cdiv style=\"font-size:22px;font-weight:700;\"\u003eØ60\/100\u003c\/div\u003e\n    \u003cdiv style=\"font-size:13px;margin-top:4px;\"\u003eCoaxial Diameter\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;border-radius:8px;padding:14px 18px;flex:1 1 130px;text-align:center;\"\u003e\n    \u003cdiv style=\"font-size:22px;font-weight:700;\"\u003e1000 mm\u003c\/div\u003e\n    \u003cdiv style=\"font-size:13px;margin-top:4px;\"\u003eOverall Kit Length\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;border-radius:8px;padding:14px 18px;flex:1 1 130px;text-align:center;\"\u003e\n    \u003cdiv style=\"font-size:22px;font-weight:700;\"\u003eHorizontal\u003c\/div\u003e\n    \u003cdiv style=\"font-size:13px;margin-top:4px;\"\u003eOrientation\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;border-radius:8px;padding:14px 18px;flex:1 1 130px;text-align:center;\"\u003e\n    \u003cdiv style=\"font-size:22px;font-weight:700;\"\u003ePush-fit\u003c\/div\u003e\n    \u003cdiv style=\"font-size:13px;margin-top:4px;\"\u003eConnection — No Clamps\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;border-radius:8px;padding:14px 18px;flex:1 1 130px;text-align:center;\"\u003e\n    \u003cdiv style=\"font-size:22px;font-weight:700;\"\u003eHE Range\u003c\/div\u003e\n    \u003cdiv style=\"font-size:13px;margin-top:4px;\"\u003eBoiler Compatibility\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#fdecea;border-left:4px solid #c0392b;padding:14px 16px;border-radius:6px;margin:18px 0;\"\u003e\n  \u003cstrong\u003e⚠ Gas Safe Registered Installer Required:\u003c\/strong\u003e Flue installation must be carried out by a \u003cstrong\u003eGas Safe registered engineer\u003c\/strong\u003e in compliance with the Gas Safety (Installation and Use) Regulations 1998, current Building Regulations, and \u003cstrong\u003eBS 5440-1:2008\u003c\/strong\u003e. Terminal position must comply with the minimum clearances from openings, gutters, and obstructions specified in the boiler installation manual.\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#fdecea;border-left:4px solid #c0392b;padding:14px 16px;border-radius:6px;margin:18px 0;\"\u003e\n  \u003cstrong\u003e⚠ HE Boilers Only — Not Compatible with Next Evo X Water Heaters:\u003c\/strong\u003e The 3318073 belongs to Ariston's \u003cstrong\u003eHE (High Efficiency) Ø60\/100 coaxial flue system\u003c\/strong\u003e and is designed for \u003cstrong\u003eAriston condensing boilers only\u003c\/strong\u003e. It is \u003cstrong\u003enot compatible\u003c\/strong\u003e with the Ariston Next Evo X range of gas water heaters, which use the \u003cstrong\u003eSE flue system — Part No. 3319648\u003c\/strong\u003e. Do not interchange HE and SE flue accessories.\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#e6f4f3;border-left:4px solid #008377;padding:14px 16px;border-radius:6px;margin:18px 0;\"\u003e\n  \u003cstrong\u003eℹ Also Available as 3318074 Bundle:\u003c\/strong\u003e If you also need the \u003cstrong\u003eVertical Starter (3318079)\u003c\/strong\u003e — for example to give the installer the option to route vertically on the day — the \u003cstrong\u003e3318074\u003c\/strong\u003e supplies this horizontal kit and the vertical starter together in one order. Buy the \u003cstrong\u003e3318073 alone\u003c\/strong\u003e when the flue route is confirmed as horizontal and the vertical starter is not needed.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(260px,1fr));gap:16px;margin:24px 0;\"\u003e\n\n  \u003cdiv style=\"border:1px solid #ddd;border-radius:8px;padding:16px;\"\u003e\n    \u003cdiv style=\"font-size:16px;font-weight:700;border-bottom:2px solid #008377;padding-bottom:6px;margin-bottom:10px;\"\u003eCoaxial Design — Single Wall Penetration\u003c\/div\u003e\n    \u003cp style=\"margin:0;font-size:15px;\"\u003eThe \u003cstrong\u003econcentric coaxial construction\u003c\/strong\u003e carries both combustion exhaust gases (inner pipe) and incoming fresh combustion air (outer annulus) through \u003cstrong\u003eone 100mm hole in the wall\u003c\/strong\u003e. This eliminates the need for a separate air intake grille and reduces the visual impact at the wall face compared to twin-pipe systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border:1px solid #ddd;border-radius:8px;padding:16px;\"\u003e\n    \u003cdiv style=\"font-size:16px;font-weight:700;border-bottom:2px solid #008377;padding-bottom:6px;margin-bottom:10px;\"\u003e1000mm Length — Most Walls in One Kit\u003c\/div\u003e\n    \u003cp style=\"margin:0;font-size:15px;\"\u003eThe \u003cstrong\u003e1000mm overall length\u003c\/strong\u003e covers the vast majority of standard UK domestic cavity and solid wall thicknesses without any extensions. The kit can be \u003cstrong\u003ecut to length on site\u003c\/strong\u003e where the wall is thinner than the kit — follow the installation manual's trimming procedure to ensure the inner pipe seal remains correctly positioned after cutting.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border:1px solid #ddd;border-radius:8px;padding:16px;\"\u003e\n    \u003cdiv style=\"font-size:16px;font-weight:700;border-bottom:2px solid #008377;padding-bottom:6px;margin-bottom:10px;\"\u003ePush-fit Throughout — Fast, Leak-free Assembly\u003c\/div\u003e\n    \u003cp style=\"margin:0;font-size:15px;\"\u003eAll joints in the HE Ø60\/100 system — including the connection to the boiler turret and any extensions or elbows — use \u003cstrong\u003epush-fit with integral lip seals\u003c\/strong\u003e. No sealant or external clamps are required on flue joints. This speeds installation and eliminates sealant compatibility concerns on condensing flue gas temperatures.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border:1px solid #ddd;border-radius:8px;padding:16px;\"\u003e\n    \u003cdiv style=\"font-size:16px;font-weight:700;border-bottom:2px solid #008377;padding-bottom:6px;margin-bottom:10px;\"\u003eExtendable with HE Accessories\u003c\/div\u003e\n    \u003cp style=\"margin:0;font-size:15px;\"\u003eWhere walls exceed the kit length or the flue must route around an obstacle, the \u003cstrong\u003efull HE Ø60\/100 accessory range\u003c\/strong\u003e extends and redirects the run: \u003cstrong\u003e3318078 (500mm extension)\u003c\/strong\u003e, \u003cstrong\u003e3318077 (1m extension)\u003c\/strong\u003e, \u003cstrong\u003e3318465 (2m extension)\u003c\/strong\u003e, \u003cstrong\u003e3318075 (90° elbow)\u003c\/strong\u003e, \u003cstrong\u003e3318076 (45° bend pair)\u003c\/strong\u003e. Maximum permissible run decreases with each elbow — refer to the installation manual.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border:1px solid #ddd;border-radius:8px;padding:16px;\"\u003e\n    \u003cdiv style=\"font-size:16px;font-weight:700;border-bottom:2px solid #008377;padding-bottom:6px;margin-bottom:10px;\"\u003eCorrect Slope — Condensate Drainage\u003c\/div\u003e\n    \u003cp style=\"margin:0;font-size:15px;\"\u003eThe horizontal flue must be installed with a \u003cstrong\u003eslight downward fall toward the terminal\u003c\/strong\u003e (approximately 2–3° or 44mm per metre) so that condensate formed in the flue drains away from the boiler rather than back into the heat exchanger. This slope is a \u003cstrong\u003eBuilding Regulations and manufacturer requirement\u003c\/strong\u003e — not optional.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border:1px solid #ddd;border-radius:8px;padding:16px;\"\u003e\n    \u003cdiv style=\"font-size:16px;font-weight:700;border-bottom:2px solid #008377;padding-bottom:6px;margin-bottom:10px;\"\u003eGenuine Ariston HE Part\u003c\/div\u003e\n    \u003cp style=\"margin:0;font-size:15px;\"\u003eAs a \u003cstrong\u003egenuine Ariston HE flue accessory\u003c\/strong\u003e, the 3318073 is dimensioned and tested to match the HE boiler range's combustion fan pressure, flue gas temperature, and turret geometry. Third-party Ø60\/100 kits may vary in internal diameter, gasket sizing, or terminal design in ways that impair combustion performance or compromise weatherproofing — and may void the boiler warranty.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"overflow-x:auto;margin:24px 0;\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;\"\u003e\n  \u003ctr style=\"background:#008377CF;color:#fff;\"\u003e\n    \u003cth style=\"padding:10px 12px;text-align:left;\" colspan=\"2\"\u003eSpecifications — Ariston Standard Horizontal Flue Kit 3318073\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e3318073\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e\u003cstrong\u003eFlue System\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003eHE Ø60\/100 mm coaxial (concentric)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e\u003cstrong\u003eOrientation\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003eHorizontal — through wall\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e\u003cstrong\u003eOverall Length\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e1000 mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e\u003cstrong\u003eWall Hole Required\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e110 mm diameter (core drill)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003ePush-fit with lip seal — no sealant or clamps on flue joints\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e\u003cstrong\u003eCompatible Boiler Ranges\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003eE-Combi ONE 24\/30, Clas ONE 24\/30\/38, Clas System ONE, Genus ONE+ Wi-Fi, Alteas ONE, Alteas ONE+ NET, E-System ONE\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e\u003cstrong\u003eNot Compatible With\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003eAriston Next Evo X gas water heaters — use SE kit 3319648 for those appliances\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e\u003cstrong\u003eMax Horizontal Run — E-Combi ONE 24 kW\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e8 m (Ø60\/100) — refer to installation manual for elbow deductions\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e\u003cstrong\u003eMax Horizontal Run — E-Combi ONE 30 kW\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e7 m (Ø60\/100) — refer to installation manual for elbow deductions\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e\u003cstrong\u003eRequired Installation Slope\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003eFall toward terminal — approx. 2–3° (44mm per metre)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e\u003cstrong\u003eAlso Available As\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px 12px;border-bottom:1px solid #e0e0e0;\"\u003e3318074 (this kit + Vertical Starter 3318079, bundled); 3319163 (silver version for Alteas ONE+ NET)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px 12px;\"\u003e\u003cstrong\u003eHE Extension Accessories\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px 12px;\"\u003e3318078 (500mm), 3318077 (1m), 3318465 (2m), 3318075 (90° elbow), 3318076 (45° bend pair)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin:28px 0;\"\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;padding:12px 16px;border-radius:6px 6px 0 0;font-weight:700;font-size:16px;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\n  \u003cdetails style=\"border:1px solid #ddd;border-top:none;padding:0;\"\u003e\n    \u003csummary style=\"padding:14px 16px;cursor:pointer;font-weight:600;background:#f9f9f9;\"\u003eCan I cut the 3318073 kit to fit a thinner wall?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:14px 16px;border-top:1px solid #eee;\"\u003eYes — the kit can be trimmed on site to match the wall thickness. \u003cstrong\u003eCut only the outer pipe\u003c\/strong\u003e to the required length; the inner flue pipe must remain at its original length to ensure the exhaust seal is correctly positioned within the boiler turret. Follow the cutting procedure in the Ariston installation manual precisely — incorrect trimming can displace the inner pipe seal and cause flue gas spillage.\u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails style=\"border:1px solid #ddd;border-top:none;padding:0;\"\u003e\n    \u003csummary style=\"padding:14px 16px;cursor:pointer;font-weight:600;background:#f9f9f9;\"\u003eWhat size hole do I need to core-drill through the wall?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:14px 16px;border-top:1px solid #eee;\"\u003eA \u003cstrong\u003e110mm diameter core-drilled hole\u003c\/strong\u003e is required through the external wall to accommodate the Ø60\/100 coaxial flue pipe and allow the wall plate to seat flush. The hole should be drilled with a slight downward slope toward the outside — approximately 2–3° — to ensure correct condensate drainage toward the terminal. Always check the installation manual for the exact offset from the boiler's centreline to the flue outlet position before marking the wall.\u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails style=\"border:1px solid #ddd;border-top:none;padding:0;\"\u003e\n    \u003csummary style=\"padding:14px 16px;cursor:pointer;font-weight:600;background:#f9f9f9;\"\u003eWhat if my wall is thicker than 1000mm, or I need to route around an obstacle?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:14px 16px;border-top:1px solid #eee;\"\u003eAdd \u003cstrong\u003eHE Ø60\/100 coaxial extension pipes\u003c\/strong\u003e between the boiler turret and the wall terminal: \u003cstrong\u003e3318078 (500mm)\u003c\/strong\u003e, \u003cstrong\u003e3318077 (1000mm)\u003c\/strong\u003e, or \u003cstrong\u003e3318465 (2000mm)\u003c\/strong\u003e. For direction changes, use \u003cstrong\u003e3318075 (90° elbow)\u003c\/strong\u003e or \u003cstrong\u003e3318076 (45° bend pair)\u003c\/strong\u003e. Each elbow reduces the maximum permissible total flue run — check the installation manual's flue length table for the specific deduction per fitting at your boiler's output.\u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails style=\"border:1px solid #ddd;border-top:none;padding:0;\"\u003e\n    \u003csummary style=\"padding:14px 16px;cursor:pointer;font-weight:600;background:#f9f9f9;\"\u003eShould I order 3318073 or 3318074?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:14px 16px;border-top:1px solid #eee;\"\u003eOrder the \u003cstrong\u003e3318073\u003c\/strong\u003e when you are certain the flue will run horizontally and you do not need the Vertical Starter. Order the \u003cstrong\u003e3318074 bundle\u003c\/strong\u003e if you also want the \u003cstrong\u003eVertical Starter (3318079)\u003c\/strong\u003e available on site — useful when the flue route is not yet confirmed, or for an installer stocking both options. The 3318074 costs marginally more than the 3318073 alone but avoids a second order if the vertical route turns out to be necessary.\u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails style=\"border:1px solid #ddd;border-top:none;padding:0;\"\u003e\n    \u003csummary style=\"padding:14px 16px;cursor:pointer;font-weight:600;background:#f9f9f9;\"\u003eIs there a silver version for the Alteas ONE+ NET?\u003c\/summary\u003e\n    \u003cdiv style=\"padding:14px 16px;border-top:1px solid #eee;\"\u003eYes — \u003cstrong\u003ePart No. 3319163\u003c\/strong\u003e is the silver-finish version of this horizontal coaxial kit, colour-matched to the Alteas ONE+ NET's premium silver flue range (3319163–3319168). It is mechanically identical to the 3318073; the only difference is colour. Use 3319163 where visible flue pipework should coordinate with the boiler's silver aesthetic.\u003c\/div\u003e\n  \u003c\/details\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ariston","offers":[{"title":"Default Title","offer_id":65084856598877,"sku":"3318073","price":59.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/AristonHorizontalCoaxialKitplusVerticalStarter60-100mm3318074HEBoilerFlueBundle.jpg?v=1782481615","url":"https:\/\/qualityheating.co.uk\/products\/ariston-standard-horizontal-flue-kit-60-100mm-3318073-he-condensing-boiler-through-wall-coaxial-flue","provider":"AIZO Quality Heating","version":"1.0","type":"link"}