{"product_id":"adey-magnacleanse-2-complete-solution-kit-cp1-03-06199-mack02-system-flush","title":"Adey MagnaCleanse 2 Complete Solution Kit CP1-03-06199 MACK02 System Flush","description":"\u003cdiv style=\"font-size:16px;font-family:Arial,Helvetica,sans-serif;max-width:900px;margin:0 auto;color:#222;line-height:1.6;\"\u003e\n\n  \u003c!-- Intro --\u003e\n  \u003cp style=\"margin:0 0 18px;\"\u003eThe \u003cstrong\u003eADEY MagnaClean HP\u003c\/strong\u003e is a purpose-engineered \u003cstrong\u003emagnetic and non-magnetic system filter\u003c\/strong\u003e for \u003cstrong\u003eheat pumps, underfloor heating, and low-temperature renewable heating systems\u003c\/strong\u003e. Featuring ADEY's patented \u003cstrong\u003eCycloFlow™ Technology\u003c\/strong\u003e, it achieves exceptional \u003cstrong\u003efirst-pass capture\u003c\/strong\u003e of black iron oxide sludge and non-magnetic debris without restricting flow — even when the canister is full — protecting expensive heat pump equipment and maximising system efficiency. Backed by a \u003cstrong\u003e10-year warranty\u003c\/strong\u003e when registered, it is the benchmark filter for modern low-carbon heating installations.\u003c\/p\u003e\n\n  \u003c!-- Stat strip --\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;margin:0 0 24px;\"\u003e\n    \u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#fff;border-radius:6px;padding:14px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:22px;font-weight:700;\"\u003e28mm\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003eCompression connection\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#fff;border-radius:6px;padding:14px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:22px;font-weight:700;\"\u003e80 L\/min\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003eMax flow rate\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#fff;border-radius:6px;padding:14px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:22px;font-weight:700;\"\u003e6 bar\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003eMax operating pressure\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#fff;border-radius:6px;padding:14px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:22px;font-weight:700;\"\u003e95°C\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003eMax operating temp\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#fff;border-radius:6px;padding:14px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:22px;font-weight:700;\"\u003e10 Years\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003eWarranty (on registration)\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Installer warning --\u003e\n  \u003cdiv style=\"background:#fff3f3;border-left:4px solid #c0392b;border-radius:4px;padding:12px 16px;margin:0 0 14px;\"\u003e\n    \u003cstrong style=\"color:#c0392b;\"\u003eInstaller Note:\u003c\/strong\u003e Installation must be carried out by a suitably qualified engineer in accordance with current Building Regulations. Fit on the \u003cstrong\u003ereturn pipe\u003c\/strong\u003e, upstream of the heat pump, to protect the heat exchanger. \u003cstrong\u003eRegister the product\u003c\/strong\u003e with ADEY to activate the full 10-year warranty.\n  \u003c\/div\u003e\n\n  \u003c!-- Compatibility callout --\u003e\n  \u003cdiv style=\"background:#fff8e6;border-left:4px solid #e6a817;border-radius:4px;padding:12px 16px;margin:0 0 14px;\"\u003e\n    \u003cstrong style=\"color:#b07d0c;\"\u003eApplication:\u003c\/strong\u003e Specifically designed for \u003cstrong\u003eair source and ground source heat pumps\u003c\/strong\u003e, \u003cstrong\u003eunderfloor heating circuits\u003c\/strong\u003e, and any \u003cstrong\u003elow-temperature wet heating system\u003c\/strong\u003e with 28mm pipework. Not for use with 22mm pipework — use the \u003cstrong\u003eMagnaClean Micro\u003c\/strong\u003e for standard domestic boiler systems.\n  \u003c\/div\u003e\n\n  \u003c!-- Info callout --\u003e\n  \u003cdiv style=\"background:#e6f4f3;border-left:4px solid #008377CF;border-radius:4px;padding:12px 16px;margin:0 0 24px;\"\u003e\n    \u003cstrong style=\"color:#005c54;\"\u003eCycloFlow™ Technology:\u003c\/strong\u003e ADEY's proprietary \u003cstrong\u003eCycloFlow™\u003c\/strong\u003e creates a cyclonic water flow pattern within the canister, directing particles towards the magnet on the first pass and preventing re-suspension of captured debris — even when flow rates are high or the filter is heavily loaded.\n  \u003c\/div\u003e\n\n  \u003c!-- Feature cards --\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(250px,1fr));gap:16px;margin:0 0 28px;\"\u003e\n\n    \u003cdiv style=\"border:1px solid #d0ece9;border-top:3px solid #008377CF;border-radius:6px;padding:16px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;text-decoration:underline;margin-bottom:8px;\"\u003eCycloFlow™ First-Pass Capture\u003c\/div\u003e\n      \u003cp style=\"margin:0;font-size:15px;\"\u003ePatented \u003cstrong\u003eCycloFlow™ Technology\u003c\/strong\u003e generates a cyclonic flow that concentrates magnetic and non-magnetic particles at the magnet and gauze on the \u003cstrong\u003every first pass\u003c\/strong\u003e. This is critical in heat pump systems where lower flow velocities can cause debris to settle rather than be captured.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border:1px solid #d0ece9;border-top:3px solid #008377CF;border-radius:6px;padding:16px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;text-decoration:underline;margin-bottom:8px;\"\u003eNon-Blocking Design\u003c\/div\u003e\n      \u003cp style=\"margin:0;font-size:15px;\"\u003eThe MagnaClean HP is engineered to \u003cstrong\u003emaintain system flow even when the canister is fully loaded\u003c\/strong\u003e with debris. In heat pump systems, any restriction in flow can trip safety cutouts and cause costly call-outs — the HP's non-blocking architecture eliminates this risk.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border:1px solid #d0ece9;border-top:3px solid #008377CF;border-radius:6px;padding:16px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;text-decoration:underline;margin-bottom:8px;\"\u003eHigh Flow Rate — 80 L\/min\u003c\/div\u003e\n      \u003cp style=\"margin:0;font-size:15px;\"\u003eSupporting flows \u003cstrong\u003eup to 80 litres per minute\u003c\/strong\u003e with minimal pressure drop, the HP handles the higher volumetric flow rates typical of heat pump primary circuits and large UFH manifolds without compromising filtration performance or system operation.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border:1px solid #d0ece9;border-top:3px solid #008377CF;border-radius:6px;padding:16px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;text-decoration:underline;margin-bottom:8px;\"\u003eStainless Steel Gauze for Biofilm\u003c\/div\u003e\n      \u003cp style=\"margin:0;font-size:15px;\"\u003eA fine \u003cstrong\u003estainless steel gauze\u003c\/strong\u003e captures non-magnetic debris and provides a surface for \u003cstrong\u003ebiological film removal\u003c\/strong\u003e — particularly relevant in open or semi-open systems where bacterial growth can develop. This dual mechanism addresses threats that magnetic filtration alone cannot.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border:1px solid #d0ece9;border-top:3px solid #008377CF;border-radius:6px;padding:16px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;text-decoration:underline;margin-bottom:8px;\"\u003eOne-Way Chemical Dosing Valve\u003c\/div\u003e\n      \u003cp style=\"margin:0;font-size:15px;\"\u003eThe integrated \u003cstrong\u003eone-way dosing valve\u003c\/strong\u003e allows \u003cstrong\u003eADEY MC1+ Protector or MC3+ Cleaner\u003c\/strong\u003e to be introduced without draining down the system. Quick and tool-free inhibitor dosing means annual servicing is straightforward — an important advantage in plant rooms with limited access.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border:1px solid #d0ece9;border-top:3px solid #008377CF;border-radius:6px;padding:16px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;text-decoration:underline;margin-bottom:8px;\"\u003eLarge 28mm Canister Ports\u003c\/div\u003e\n      \u003cp style=\"margin:0;font-size:15px;\"\u003e\u003cstrong\u003e28mm compression fittings\u003c\/strong\u003e and large-bore canister ports match the pipework dimensions typical of heat pump primary circuits, ensuring \u003cstrong\u003eminimal restriction\u003c\/strong\u003e to the system. The \u003cstrong\u003e250.5mm × 115mm canister\u003c\/strong\u003e provides substantial debris-holding capacity between service intervals.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- Spec table --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;margin:0 0 28px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background:#008377CF;color:#fff;\"\u003e\n        \u003cth style=\"padding:10px 12px;text-align:left;width:45%;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"padding:10px 12px;text-align:left;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#f4fbfa;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003eMAGNAHP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003eHeat pumps, underfloor heating, low-temperature \u0026amp; renewable heating systems\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f4fbfa;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e\u003cstrong\u003eConnection Size\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e28mm compression\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e\u003cstrong\u003eMax Operating Pressure\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e6 bar\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f4fbfa;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e\u003cstrong\u003eMax Flow Rate\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003eUp to 80 litres\/minute\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e\u003cstrong\u003eMax Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e95°C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f4fbfa;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003eGlass-reinforced nylon\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e\u003cstrong\u003eFiltration Technology\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003eCycloFlow™ magnetic + stainless steel gauze (non-magnetic)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f4fbfa;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e250.5 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e\u003cstrong\u003eWidth (at lid)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e115 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f4fbfa;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e\u003cstrong\u003eInstallation Position\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003eIndoor, return pipe (recommended)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e\u003cstrong\u003eChemical Dosing\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003eOne-way valve (tool-free, no system drain required)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f4fbfa;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #d0ece9;\"\u003e10 years (registration required)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;\"\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;\"\u003e5060106370128\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- FAQs --\u003e\n  \u003cdiv style=\"margin:0 0 8px;\"\u003e\n    \u003cdetails style=\"border:1px solid #d0ece9;border-radius:6px;margin-bottom:8px;overflow:hidden;\"\u003e\n      \u003csummary style=\"background:#008377CF;color:#fff;padding:12px 16px;cursor:pointer;font-weight:600;list-style:none;\"\u003eWhy do heat pumps need a dedicated filter like the HP model?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:14px 16px;background:#f4fbfa;\"\u003e\n        \u003cp style=\"margin:0;\"\u003eHeat pump primary circuits operate at \u003cstrong\u003elow flow temperatures and high flow rates\u003c\/strong\u003e, and their heat exchangers have tighter tolerances than boiler heat exchangers. Even small amounts of sludge, debris, or biofilm can cause \u003cstrong\u003eCOP degradation, increased running costs, and premature component failure\u003c\/strong\u003e. A filter rated for heat pump flow rates and providing first-pass capture — like the MagnaClean HP — is essential.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border:1px solid #d0ece9;border-radius:6px;margin-bottom:8px;overflow:hidden;\"\u003e\n      \u003csummary style=\"background:#008377CF;color:#fff;padding:12px 16px;cursor:pointer;font-weight:600;list-style:none;\"\u003eWhat is CycloFlow™ Technology and why does it matter?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:14px 16px;background:#f4fbfa;\"\u003e\n        \u003cp style=\"margin:0;\"\u003e\u003cstrong\u003eCycloFlow™\u003c\/strong\u003e is ADEY's patented internal geometry that induces a cyclonic spiral flow path through the canister. This forces particles — magnetic and non-magnetic — to the outer wall and towards the capture zone on the \u003cstrong\u003efirst pass\u003c\/strong\u003e, rather than relying on multiple passes for full removal. In heat pump systems with long pipe runs and complex circuits, first-pass efficiency is vital.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border:1px solid #d0ece9;border-radius:6px;margin-bottom:8px;overflow:hidden;\"\u003e\n      \u003csummary style=\"background:#008377CF;color:#fff;padding:12px 16px;cursor:pointer;font-weight:600;list-style:none;\"\u003eHow do I activate the 10-year warranty?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:14px 16px;background:#f4fbfa;\"\u003e\n        \u003cp style=\"margin:0;\"\u003eThe \u003cstrong\u003e10-year warranty requires product registration\u003c\/strong\u003e with ADEY after installation. Registration can be completed at \u003cstrong\u003eadey.com\u003c\/strong\u003e. Without registration, a standard warranty period applies. Retaining proof of purchase and installation records is also recommended for warranty claims.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border:1px solid #d0ece9;border-radius:6px;margin-bottom:8px;overflow:hidden;\"\u003e\n      \u003csummary style=\"background:#008377CF;color:#fff;padding:12px 16px;cursor:pointer;font-weight:600;list-style:none;\"\u003eCan the HP filter be used on an underfloor heating system?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:14px 16px;background:#f4fbfa;\"\u003e\n        \u003cp style=\"margin:0;\"\u003eYes. The MagnaClean HP is equally well-suited to \u003cstrong\u003eunderfloor heating manifold circuits\u003c\/strong\u003e as to heat pump primary circuits. Fit it on the return pipe upstream of the manifold or heat pump heat exchanger. The \u003cstrong\u003e28mm compression connections\u003c\/strong\u003e are compatible with standard UFH pipework sizes when used with appropriate reducers where needed.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border:1px solid #d0ece9;border-radius:6px;margin-bottom:8px;overflow:hidden;\"\u003e\n      \u003csummary style=\"background:#008377CF;color:#fff;padding:12px 16px;cursor:pointer;font-weight:600;list-style:none;\"\u003eHow frequently should the MagnaClean HP be serviced?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:14px 16px;background:#f4fbfa;\"\u003e\n        \u003cp style=\"margin:0;\"\u003eADEY recommends cleaning the HP filter \u003cstrong\u003eannually\u003c\/strong\u003e as part of the heat pump's scheduled maintenance. The built-in one-way dosing valve allows \u003cstrong\u003einhibitor top-up without draining\u003c\/strong\u003e. Check ADEY MC1+ concentration levels at service and dose accordingly. On first-year installations following a new build or refurbishment, an interim check at 3–6 months is advisable.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"ADEY","offers":[{"title":"Default Title","offer_id":64930000273757,"sku":"MACK02","price":595.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Adey-MagnaCleanse2-System-Flush-CP1-03-06199.jpg?v=1780996627","url":"https:\/\/qualityheating.co.uk\/products\/adey-magnacleanse-2-complete-solution-kit-cp1-03-06199-mack02-system-flush","provider":"AIZO Quality Heating","version":"1.0","type":"link"}