{"product_id":"10mm2-black-solar-pv-dc-cable-100m-reel-h1z2z2-k","title":"10mm2 Black Solar PV DC Cable - 100M Reel (H1Z2Z2-K)","description":"\u003c!-- SEO Product Name: 10mm2 Black Solar PV DC Cable - 100M Reel (H1Z2Z2-K, EN 50618) --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#2B2B2B; line-height:1.6; font-family:Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eThis \u003cstrong\u003e100 metre reel of 10mm² solar PV DC cable\u003c\/strong\u003e is a single-core H1Z2Z2-K cable built to the \u003cstrong\u003eEN 50618\u003c\/strong\u003e and \u003cstrong\u003eIEC 62930\u003c\/strong\u003e photovoltaic cable standards, designed for wiring between solar panels, DC combiners, and inverters in UK PV installations.\u003c\/p\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eThe cable is \u003cstrong\u003ehalogen-free, flame-retardant and low-smoke\u003c\/strong\u003e, with an XLPO (cross-linked polyolefin) insulation and jacket that is fully UV- and ozone-resistant, giving it an anticipated service life in line with the 25–30 year lifespan of a modern solar array.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:20px -4px; justify-content:space-between;\"\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 8px; border-radius:6px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e10mm²\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eConductor Size\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 8px; border-radius:6px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e1.5\/1.5kV\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eRated DC Voltage\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 8px; border-radius:6px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e98A\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eMax Current (Exposed)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 8px; border-radius:6px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e-40°C to +90°C\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eOperating Range\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 8px; border-radius:6px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eEN 50618\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eCertified Standard\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 8px; border-radius:6px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eHalogen-Free\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eFire Safety\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:20px -6px;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:6px; padding:16px; margin:6px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eTÜV-Approved to EN 50618\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eCertified to the \u003cstrong\u003eEN 50618 (H1Z2Z2-K)\u003c\/strong\u003e and \u003cstrong\u003eIEC 62930\u003c\/strong\u003e international standards for photovoltaic wiring.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:6px; padding:16px; margin:6px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eHalogen-Free \u0026amp; Flame Retardant\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eLow-smoke, \u003cstrong\u003ehalogen-free construction\u003c\/strong\u003e means the cable will not emit toxic fumes in the event of a fire, tested to EN 60754-1 and EN 60332-1-2.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:6px; padding:16px; margin:6px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eUV \u0026amp; Ozone Resistant\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eXLPO insulation and jacket are \u003cstrong\u003efully weather, UV and ozone resistant\u003c\/strong\u003e, tested to EN 50289-4-17 for permanent outdoor exposure.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:6px; padding:16px; margin:6px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003e25+ Year Service Life\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eElectron-beam cross-linked XLPO construction gives the cable an \u003cstrong\u003eanticipated service life of 25–30 years\u003c\/strong\u003e, matching the working life of a solar PV system.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:6px; padding:16px; margin:6px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eHigh Current Carrying Capacity\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eRated to carry \u003cstrong\u003e98A when exposed in free air\u003c\/strong\u003e, dropping to 79A on surfaces with contact and 61A in conduit — more than sufficient for typical string and DC main runs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:6px; padding:16px; margin:6px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eFlexible Class 5 Copper Conductor\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eFine-wire \u003cstrong\u003eClass 5 flexible tinned copper\u003c\/strong\u003e conductor (142 x 0.285mm strands) to DIN VDE 0295 \/ IEC 60228 for easy routing and termination.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13px; text-transform:uppercase; letter-spacing:0.05em; padding:9px 14px; margin-top:14px; border-radius:4px 4px 0 0;\"\u003eElectrical Specification\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-top:none; border-radius:0 0 4px 4px; overflow:hidden; margin-bottom:4px;\"\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eConductor Cross-Section\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e10mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eRated Voltage (DC)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e1.5\/1.5kV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eRated Voltage (AC)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e1.0\/1.0kV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eMax. Permitted Voltage (DC)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e1.8kV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eConductor Resistance at 20°C\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e≤ 1.95 Ω\/km\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eMin. Insulation Resistance at 20°C\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e420 MΩ\/km\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eTest Voltage (AC)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e6.5kV, 50Hz, 5 min\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eSpark Test\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003eAC 10kV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13px; text-transform:uppercase; letter-spacing:0.05em; padding:9px 14px; margin-top:14px; border-radius:4px 4px 0 0;\"\u003eCurrent Carrying Capacity (Ambient 60°C)\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-top:none; border-radius:0 0 4px 4px; overflow:hidden; margin-bottom:4px;\"\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eExposed in Free Air\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e98A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eOn Surface Without Contact\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e93A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eOn Surface With Contact\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e79A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eIn Conduit, Pipe or Duct\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e61A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13px; text-transform:uppercase; letter-spacing:0.05em; padding:9px 14px; margin-top:14px; border-radius:4px 4px 0 0;\"\u003eConstruction\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-top:none; border-radius:0 0 4px 4px; overflow:hidden; margin-bottom:4px;\"\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eConductor\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003eClass 5 flexible tinned copper, 142 x 0.285mm strands (DIN VDE 0295 \/ IEC 60228)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eInsulation\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003eXLPO, electron-beam cross-linked, low-smoke halogen-free — 0.7mm nominal thickness\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eJacket\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003eXLPO, electron-beam cross-linked, low-smoke halogen-free — 0.8mm nominal thickness\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eOuter Diameter\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003eApprox. 7.5mm ± 0.2mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eColour\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003eBlack\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eMinimum Bend Radius\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e4 x overall diameter (fixed) \/ 5 x overall diameter (flexing)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13px; text-transform:uppercase; letter-spacing:0.05em; padding:9px 14px; margin-top:14px; border-radius:4px 4px 0 0;\"\u003eEnvironmental \u0026amp; Fire Performance\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-top:none; border-radius:0 0 4px 4px; overflow:hidden; margin-bottom:4px;\"\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eOperating Temperature Range\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e-40°C to +90°C (max. conductor temperature +120°C)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eShort-Circuit Temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e250°C for 5 seconds\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eUV \u0026amp; Weather Resistance\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003eTested to EN 50289-4-17\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eOzone Resistance\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003eTested to EN 50396, cl. 8.1.3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eHalogen-Free\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003eTested to EN 60754-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eFlame Retardant\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003eTested to EN 60332-1-2\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eAnticipated Service Life\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003e30 years\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13px; text-transform:uppercase; letter-spacing:0.05em; padding:9px 14px; margin-top:14px; border-radius:4px 4px 0 0;\"\u003eStandards \u0026amp; Approvals\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-top:none; border-radius:0 0 4px 4px; overflow:hidden; margin-bottom:4px;\"\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eCable Standard\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003eEN 50618 (H1Z2Z2-K)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; color:#333333; font-size:14px;\"\u003eAdditional Standard\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; color:#222222; font-size:14px;\"\u003eIEC 62930\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FDECEC; border-left:4px solid #D32F2F; padding:14px 18px; margin:18px 0; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#D32F2F; font-size:14px; margin-bottom:4px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eImportant Safety Information\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px; color:#2B2B2B; line-height:1.6;\"\u003eThis cable is for \u003cstrong\u003eDC use only\u003c\/strong\u003e and must never be disconnected under load. Isolate the DC side of the PV system fully before connecting or disconnecting any cable runs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E6F4F3; border-left:4px solid #008377CF; padding:14px 18px; margin:18px 0; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; font-size:14px; margin-bottom:4px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eGood to Know\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px; color:#2B2B2B; line-height:1.6;\"\u003eAlso available as a \u003cstrong\u003e500m reel\u003c\/strong\u003e in black, and in both 100m and 500m lengths in red, for correct positive\/negative polarity identification across your installation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:20px 0;\"\u003e\n\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eWhat is H1Z2Z2-K cable and why is it used for solar panels?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eH1Z2Z2-K is the European standard designation for single-core, double-insulated, halogen-free photovoltaic cable certified to \u003cstrong\u003eEN 50618\u003c\/strong\u003e. It is the industry-standard cable type for DC wiring between solar panels, combiners and inverters across UK and EU installations.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eIs this cable suitable for outdoor use?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eYes. The cable's XLPO insulation and jacket are \u003cstrong\u003eUV and ozone resistant\u003c\/strong\u003e and rated for continuous outdoor exposure across an operating range of -40°C to +90°C, with an anticipated service life of up to 30 years.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eCan this cable be used both for panel-to-panel and DC main runs?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eYes. At 10mm², this cable is commonly used both for interconnecting PV modules\/strings and for longer \u003cstrong\u003eDC main cable runs\u003c\/strong\u003e from the array combiner to the inverter, where the larger cross-section reduces voltage drop over distance.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eWhat connectors are compatible with this cable?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003e10mm² H1Z2Z2-K cable is compatible with standard \u003cstrong\u003eMC4 and MC4-compatible solar connectors\u003c\/strong\u003e rated for 10mm² conductors — confirm your chosen connector's crimp barrel size matches this cable's conductor diameter before ordering.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eDo I need to run cables in red and black for polarity?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eBest practice for DC PV wiring is to use one black cable for negative and one red (or clearly marked) cable for positive to maintain clear polarity identification throughout the system, in line with standard UK wiring practice.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eWhat's the difference between the 100m and 500m reel?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eBoth reels contain the same 10mm² H1Z2Z2-K black cable to the same specification — the only difference is the length supplied per reel, allowing you to size the purchase to the scale of your installation.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Kuka Cable","offers":[{"title":"Default Title","offer_id":65812879573341,"sku":"PV842910-100M","price":220.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SolarCable4mm_Single-CoreDCCable-100m_Black.png?v=1762448450","url":"https:\/\/qualityheating.co.uk\/products\/10mm2-black-solar-pv-dc-cable-100m-reel-h1z2z2-k","provider":"AIZO Quality Heating","version":"1.0","type":"link"}