{"product_id":"10kw-slimjim-electric-flow-boiler-170l-direct-cylinder","title":"EHC 10kW SlimJim Electric Flow Boiler \u0026 170L Direct Cylinder","description":"\u003c!-- SEO Product Name: EHC SlimJim 10kW \u0026 170L Direct Cylinder Pack | EHCSJ10\/170 --\u003e\n\u003cdiv style=\"font-size: 16px; max-width: 900px; color: #222222; font-family: Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"margin: 0 0 14px; line-height: 1.6;\"\u003eThe \u003cstrong\u003eEHC SlimJim 10 kW Electric Flow Boiler with 170L Direct Cylinder\u003c\/strong\u003e (EHCSJ10\/170) is a \u003cstrong\u003epre-matched boiler and unvented cylinder package\u003c\/strong\u003e for all-electric heating and hot water. A \u003cstrong\u003e100% efficient, flueless SlimJim boiler\u003c\/strong\u003e heats the radiators, while a \u003cstrong\u003estainless steel direct unvented cylinder\u003c\/strong\u003e with \u003cstrong\u003etwo 3 kW immersion heaters\u003c\/strong\u003e supplies mains pressure hot water.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 14px; line-height: 1.6;\"\u003eThe pack includes the \u003cstrong\u003e24\/7 programmer, room thermostat, hot water programmer, high efficiency circulating pump, lockshield pump valves, 8 litre Robo kit, automatic air vent and magnetic filter\u003c\/strong\u003e, plus the cylinder's \u003cstrong\u003einlet control set, temperature and pressure relief valve, expansion vessel and tundish\u003c\/strong\u003e. You only need to add radiators, radiator valves and pipework.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 14px; line-height: 1.6;\"\u003eEHC positions this pack for \u003cstrong\u003etwo-bedroom properties\u003c\/strong\u003e. Because the boiler is 100% efficient there is no need to oversize it, so size the installation from a \u003cstrong\u003eheat loss calculation to BS EN 12831\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 10px; margin: 20px 0;\"\u003e\n\u003cdiv style=\"flex: 1 1 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px 8px; text-align: center; background: #E6F2F1;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; color: #008377cf;\"\u003e10 kW\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #333333; margin-top: 4px;\"\u003eBoiler output\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px 8px; text-align: center; background: #E6F2F1;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; color: #008377cf;\"\u003e170 L\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #333333; margin-top: 4px;\"\u003eDirect cylinder\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px 8px; text-align: center; background: #E6F2F1;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; color: #008377cf;\"\u003e100%\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #333333; margin-top: 4px;\"\u003eEfficient, no flue\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px 8px; text-align: center; background: #E6F2F1;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; color: #008377cf;\"\u003e41.7 A\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #333333; margin-top: 4px;\"\u003eBoiler load current\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px 8px; text-align: center; background: #E6F2F1;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; color: #008377cf;\"\u003e25 Years\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #333333; margin-top: 4px;\"\u003eCylinder warranty\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px 8px; text-align: center; background: #E6F2F1;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; color: #008377cf;\"\u003e2 Bed\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #333333; margin-top: 4px;\"\u003eEHC sizing guide\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left: 6px solid #B3261E; background: #FDECEA; padding: 14px 18px; margin: 14px 0; border-radius: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #b3261e; font-size: 17px; margin-bottom: 6px;\"\u003eElectrical safety, load check and unvented regulations\u003c\/div\u003e\n\u003cdiv style=\"line-height: 1.55;\"\u003eHave a qualified electrician carry out a \u003cstrong\u003eload check\u003c\/strong\u003e before installation; the incoming supply may need upgrading. The manufacturer recommends \u003cstrong\u003e50 A protection\u003c\/strong\u003e for the boiler, a \u003cstrong\u003e30 mA double pole RCD\u003c\/strong\u003e and a minimum \u003cstrong\u003e10 mm² cable cross-section\u003c\/strong\u003e, with final sizing to \u003cstrong\u003eBS 7671\u003c\/strong\u003e by the electrician. The maximum permitted network impedance is \u003cstrong\u003e0.29 Ω\u003c\/strong\u003e. The two \u003cstrong\u003e3 kW immersion heaters\u003c\/strong\u003e must be included in the electrician's load assessment. The cylinder is an \u003cstrong\u003eunvented hot water system\u003c\/strong\u003e, so it must be installed, commissioned and its discharge arranged by a \u003cstrong\u003eG3-qualified installer\u003c\/strong\u003e to the Building Regulations.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left: 6px solid #008377CF; background: #E6F2F1; padding: 14px 18px; margin: 14px 0; border-radius: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; font-size: 17px; margin-bottom: 6px;\"\u003eHow a direct cylinder works with this pack\u003c\/div\u003e\n\u003cdiv style=\"line-height: 1.55;\"\u003eThe SlimJim boiler heats the \u003cstrong\u003eradiators only\u003c\/strong\u003e. The \u003cstrong\u003edirect cylinder\u003c\/strong\u003e heats domestic hot water with its \u003cstrong\u003etwo 3 kW immersion elements\u003c\/strong\u003e, controlled by the \u003cstrong\u003ehot water programmer\u003c\/strong\u003e. Because a direct cylinder reheats more slowly than an indirect one, the manufacturer suggests considering an \u003cstrong\u003eindirect cylinder pack\u003c\/strong\u003e for properties with high hot water demand. Radiators, valves and pipework are not included.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size: 20px; color: #008377cf; border-bottom: 3px solid #008377CF; padding-bottom: 6px; margin: 30px 0 14px; font-weight: bold;\"\u003eKey features\u003c\/h3\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px; margin: 14px 0;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 6px; padding: 14px; background: #FFFFFF;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; font-size: 16px; margin-bottom: 6px;\"\u003eComplete pre-matched pack\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 1.5;\"\u003eBoiler, \u003cstrong\u003eunvented stainless steel cylinder\u003c\/strong\u003e, controls, pump, Robo kit, air vent and magnetic filter are specified together, so there is one pack to order and fewer parts to source.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 6px; padding: 14px; background: #FFFFFF;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; font-size: 16px; margin-bottom: 6px;\"\u003e100% efficient, no flue\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 1.5;\"\u003eThe \u003cstrong\u003einsulated stainless steel heat exchanger\u003c\/strong\u003e converts all the electricity into heat, with \u003cstrong\u003eno flue, no gas supply and no combustion analysis\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 6px; padding: 14px; background: #FFFFFF;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; font-size: 16px; margin-bottom: 6px;\"\u003eCompact SlimJim boiler\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 1.5;\"\u003eThe wall-mounted boiler measures \u003cstrong\u003e912 x 203 x 172 mm\u003c\/strong\u003e and weighs \u003cstrong\u003e11 kg\u003c\/strong\u003e, designed to free up cupboard space.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 6px; padding: 14px; background: #FFFFFF;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; font-size: 16px; margin-bottom: 6px;\"\u003eNeptune stainless steel cylinder\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 1.5;\"\u003eA floor-standing \u003cstrong\u003e170 litre direct unvented cylinder\u003c\/strong\u003e with a \u003cstrong\u003e25 year warranty\u003c\/strong\u003e and \u003cstrong\u003e2 x 3 kW immersion\u003c\/strong\u003e heating.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 6px; padding: 14px; background: #FFFFFF;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; font-size: 16px; margin-bottom: 6px;\"\u003eBuilt-in boiler protection\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 1.5;\"\u003eA \u003cstrong\u003erun-dry water level sensor\u003c\/strong\u003e, \u003cstrong\u003e100°C thermal cut-out\u003c\/strong\u003e and \u003cstrong\u003ehigh current safety device\u003c\/strong\u003e protect the boiler, with in-built fault diagnostics for faster servicing.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 6px; padding: 14px; background: #FFFFFF;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; font-size: 16px; margin-bottom: 6px;\"\u003eFlexible control and system fit\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eVolt-free or 240 V control\u003c\/strong\u003e via a DIP switch, \u003cstrong\u003ethree selectable power stages\u003c\/strong\u003e, and suitability for \u003cstrong\u003eradiators and wet underfloor heating\u003c\/strong\u003e on a sealed system.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size: 20px; color: #008377cf; border-bottom: 3px solid #008377CF; padding-bottom: 6px; margin: 30px 0 14px; font-weight: bold;\"\u003eInstallation essentials\u003c\/h3\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px; margin: 14px 0;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; border: 1px solid #008377CF; border-radius: 6px; background: #E6F2F1; overflow: hidden;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 8px 14px;\"\u003e1. Site the boiler\u003c\/div\u003e\n\u003cdiv style=\"padding: 12px 14px; font-size: 15px; line-height: 1.5;\"\u003eMount it \u003cstrong\u003eupright\u003c\/strong\u003e on a wall with an adequate fixing. Allow \u003cstrong\u003e400 mm\u003c\/strong\u003e at the front and \u003cstrong\u003e50 mm\u003c\/strong\u003e each side. Fit frost protection where the room can fall below 0°C.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; border: 1px solid #008377CF; border-radius: 6px; background: #E6F2F1; overflow: hidden;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 8px 14px;\"\u003e2. Site the cylinder\u003c\/div\u003e\n\u003cdiv style=\"padding: 12px 14px; font-size: 15px; line-height: 1.5;\"\u003eThe floor-standing cylinder weighs \u003cstrong\u003e40 kg\u003c\/strong\u003e empty and \u003cstrong\u003e208 kg\u003c\/strong\u003e full, at \u003cstrong\u003e1200 x 510 mm\u003c\/strong\u003e. Check the floor can carry the full weight.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; border: 1px solid #008377CF; border-radius: 6px; background: #E6F2F1; overflow: hidden;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 8px 14px;\"\u003e3. Connect the pipework\u003c\/div\u003e\n\u003cdiv style=\"padding: 12px 14px; font-size: 15px; line-height: 1.5;\"\u003eFlow (top) and return (bottom) are \u003cstrong\u003e22 mm compression\u003c\/strong\u003e and must never be reversed. Fit full bore lockshield isolation valves.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; border: 1px solid #008377CF; border-radius: 6px; background: #E6F2F1; overflow: hidden;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 8px 14px;\"\u003e4. Filter, pump and air vent\u003c\/div\u003e\n\u003cdiv style=\"padding: 12px 14px; font-size: 15px; line-height: 1.5;\"\u003eFit the \u003cstrong\u003emagnetic filter on the return before the pump\u003c\/strong\u003e. Position the \u003cstrong\u003eautomatic air vent\u003c\/strong\u003e to the side of the boiler, never directly above it.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; border: 1px solid #008377CF; border-radius: 6px; background: #E6F2F1; overflow: hidden;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 8px 14px;\"\u003e5. Cylinder safety discharge\u003c\/div\u003e\n\u003cdiv style=\"padding: 12px 14px; font-size: 15px; line-height: 1.5;\"\u003eThe inlet control set, \u003cstrong\u003etemperature and pressure relief valve\u003c\/strong\u003e and \u003cstrong\u003etundish\u003c\/strong\u003e must be piped to a safe discharge to G3 by a qualified installer.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; border: 1px solid #008377CF; border-radius: 6px; background: #E6F2F1; overflow: hidden;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 8px 14px;\"\u003e6. Flush and commission\u003c\/div\u003e\n\u003cdiv style=\"padding: 12px 14px; font-size: 15px; line-height: 1.5;\"\u003eFlush to BS 7593, add inhibitor, and commission at a normal working pressure of about \u003cstrong\u003e1.0 to 1.5 bar\u003c\/strong\u003e. Clean the magnetic filter annually.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size: 20px; color: #008377cf; border-bottom: 3px solid #008377CF; padding-bottom: 6px; margin: 30px 0 14px; font-weight: bold;\"\u003eWhat is in the pack\u003c\/h3\u003e\n\u003cdiv style=\"border: 1px solid #008377CF; border-radius: 6px; overflow: hidden; margin: 14px 0;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 9px 14px;\"\u003ePack contents\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eBoiler\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003eSlimJim 10 kW electric flow boiler\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eCylinder\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003eNeptune 170 litre direct unvented stainless steel cylinder (NDIR170L) with combination valve, temperature and pressure relief valve, DHW expansion vessel, tundish and 2 x 3 kW immersion elements\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eControls\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e24\/7 programmer, room thermostat, hot water programmer\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003ePump and system\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003eHigh efficiency circulating pump, lockshield pump valves, 8 litre Robo kit, automatic air vent, magnetic filter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eDocuments\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003eInstallation and maintenance instructions, Benchmark logbook\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eNot included\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003eRadiators, radiator valves and pipework\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size: 20px; color: #008377cf; border-bottom: 3px solid #008377CF; padding-bottom: 6px; margin: 30px 0 14px; font-weight: bold;\"\u003eSlimJim pack range at a glance\u003c\/h3\u003e\n\u003cdiv style=\"border: 1px solid #008377CF; border-radius: 6px; overflow: hidden; margin: 14px 0;\"\u003e\n\u003cdiv style=\"display: flex; background: #008377CF; color: #ffffff; font-weight: bold;\"\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 9px 10px; font-size: 14px;\"\u003ePack code\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 9px 10px; font-size: 14px;\"\u003eBoiler\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 9px 10px; font-size: 14px;\"\u003eCylinder\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 9px 10px; font-size: 14px;\"\u003eImmersion\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 9px 10px; font-size: 14px;\"\u003eProtection\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 9px 10px; font-size: 14px;\"\u003eEHC sizing guide\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #F3F9F8; border-bottom: 1px solid #D5E8E6; font-weight: normal;\"\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003eEHCSJ7\/120\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e7 kW\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e120 L direct\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e2 x 3 kW\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e40 A\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e1 bed\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #FFFFFF; border-bottom: 1px solid #D5E8E6; font-weight: normal;\"\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003eEHCSJ10\/120\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e10 kW\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e120 L direct\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e2 x 3 kW\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e50 A\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e1 to 2 bed\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #F3F9F8; border-bottom: 1px solid #D5E8E6; font-weight: normal;\"\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003eEHCSJ10\/150\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e10 kW\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e150 L direct\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e2 x 3 kW\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e50 A\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e1 to 2 bed\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #E6F2F1; border-bottom: 1px solid #D5E8E6; font-weight: bold;\"\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003eEHCSJ10\/170\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e10 kW\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e170 L direct\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e2 x 3 kW\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e50 A\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e2 bed\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #F3F9F8; border-bottom: 1px solid #D5E8E6; font-weight: normal;\"\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003eEHCSJ10\/170IND\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e10 kW\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e170 L indirect\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e1 x 3 kW\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e50 A\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 90px; padding: 8px 10px; font-size: 14px; line-height: 1.4;\"\u003e1 to 2 bed\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size: 20px; color: #008377cf; border-bottom: 3px solid #008377CF; padding-bottom: 6px; margin: 30px 0 14px; font-weight: bold;\"\u003eTechnical specification\u003c\/h3\u003e\n\u003cdiv style=\"border: 1px solid #008377CF; border-radius: 6px; overflow: hidden; margin: 14px 0;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 9px 14px;\"\u003ePack\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eModel \/ MPN\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003eEHCSJ10\/170\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eBoiler\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003eEHC SlimJim 10 kW single phase electric flow boiler\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eCylinder\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e170L pack code, Neptune NDIR170L direct unvented\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eCylinder type\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003eDirect (2 x 3 kW immersion elements)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eEHC sizing guide\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e2 bedrooms\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 9px 14px;\"\u003eBoiler\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eHeat output\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e10 kW (34,121 BTU\/h)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eSupply\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e240 V AC, single phase, 50 Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eLoad current\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e41.7 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eRecommended protection\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e50 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eMinimum cable cross-section\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e10 mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eMaximum network impedance\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e0.29 Ω\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eDimensions (H x W x D)\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e912 x 203 x 172 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eWeight\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e11 kg\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eFlow temperature\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e30 to 80°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eOverheat protection\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e100°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eSystem pressure\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003eMinimum 0.5 bar, maximum 3 bar\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eConnections\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e22 mm compression, flow top, return bottom\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eProtection class\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003eIP22\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eErP rating (heating)\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003eD\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 9px 14px;\"\u003eCylinder\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eModel\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003eNDIR170L\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eCapacity\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e170 litres\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eHeight x diameter\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e1200 x 510 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eWeight empty \/ full\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e40 kg \/ 208 kg\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eImmersion heater\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e2 x 3 kW\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #FFFFFF; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eMaterial\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003eStainless steel, unvented\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #F3F9F8; border-bottom: 1px solid #D5E8E6;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; padding: 8px 14px; font-weight: bold; color: #1f3b39;\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv style=\"flex: 2 1 300px; padding: 8px 14px; line-height: 1.5;\"\u003e25 years\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size: 20px; color: #008377cf; border-bottom: 3px solid #008377CF; padding-bottom: 6px; margin: 30px 0 14px; font-weight: bold;\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 6px; margin: 8px 0; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 14px; cursor: pointer;\"\u003eWhat is included in this pack?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px; line-height: 1.55;\"\u003eThe \u003cstrong\u003e10 kW SlimJim boiler\u003c\/strong\u003e, the \u003cstrong\u003e170 litre direct unvented cylinder\u003c\/strong\u003e, \u003cstrong\u003e24\/7 programmer, room thermostat and hot water programmer\u003c\/strong\u003e, plus the \u003cstrong\u003epump, lockshield valves, 8 litre Robo kit, air vent and magnetic filter\u003c\/strong\u003e. Radiators, valves and pipework are not included.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 6px; margin: 8px 0; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 14px; cursor: pointer;\"\u003eHow is the hot water heated?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px; line-height: 1.55;\"\u003eThe cylinder is \u003cstrong\u003edirect\u003c\/strong\u003e: its \u003cstrong\u003etwo 3 kW immersion elements\u003c\/strong\u003e heat the water, while the boiler heats the radiators only. For higher hot water demand, consider an indirect pack.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 6px; margin: 8px 0; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 14px; cursor: pointer;\"\u003eWhat electrical supply does it need?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px; line-height: 1.55;\"\u003eA \u003cstrong\u003e240 V single phase\u003c\/strong\u003e supply. The boiler draws \u003cstrong\u003e41.7 A\u003c\/strong\u003e and the manufacturer recommends \u003cstrong\u003e50 A\u003c\/strong\u003e protection, a 30 mA double pole RCD and a minimum 10 mm² cable, with final sizing to BS 7671 and a load check by a qualified electrician. Include the cylinder's immersion heater(s) in that assessment.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 6px; margin: 8px 0; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 14px; cursor: pointer;\"\u003eWhat size is the cylinder and how heavy is it?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px; line-height: 1.55;\"\u003eThe \u003cstrong\u003eNDIR170L\u003c\/strong\u003e cylinder is \u003cstrong\u003e1200 mm\u003c\/strong\u003e high and \u003cstrong\u003e510 mm\u003c\/strong\u003e in diameter, and weighs \u003cstrong\u003e40 kg\u003c\/strong\u003e empty and \u003cstrong\u003e208 kg\u003c\/strong\u003e full.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 6px; margin: 8px 0; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 14px; cursor: pointer;\"\u003eCan I use it with underfloor heating?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px; line-height: 1.55;\"\u003eYes. The SlimJim suits \u003cstrong\u003ewet underfloor heating\u003c\/strong\u003e as well as radiators, with a flow temperature of 30 to 80°C. Add the manufacturer's required controls for the underfloor circuit.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 6px; margin: 8px 0; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 14px; cursor: pointer;\"\u003eWho can install the unvented cylinder?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px; line-height: 1.55;\"\u003eAn unvented cylinder must be installed and commissioned by a \u003cstrong\u003eG3-qualified installer\u003c\/strong\u003e, with the discharge pipework to the Building Regulations. The electrical work should be carried out by a qualified electrician to \u003cstrong\u003eBS 7671\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e","brand":"EHC","offers":[{"title":"Default Title","offer_id":57822480204125,"sku":"EHCSJ10\/180","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Slimjim-A1-90-direct-2_228cc7b2-db37-48fa-8ce0-56ea0589839b.jpg?v=1750714135","url":"https:\/\/qualityheating.co.uk\/products\/10kw-slimjim-electric-flow-boiler-170l-direct-cylinder","provider":"AIZO Quality Heating","version":"1.0","type":"link"}