{"product_id":"viridian-ct-clamp-for-clearline-inverter-vir-csi-ct-export-power-limiting-dno-compliance-g98-g99-export-cap-requires-vir-csi-wifi","title":"Pince ampèremétrique Viridian pour onduleur Clearline | VIR-CSI-CT | Limitation de l’injection au réseau | Conformité DNO | Limitation de l’injection G98\/G99 | Nécessite le VIR-CSI-WIFI","description":"\u003cdiv style=\"font-family:inherit;font-size:16px;line-height:1.65;color:#1a1a1a;\"\u003e\n\n\u003cp style=\"margin-bottom:1.25rem;line-height:2.2;\"\u003e\n\u003cspan style=\"display:inline-block;background:#c0392b;color:#ffffff;border:1.5px solid #c0392b;border-radius:4px;padding:3px 10px;font-size:11px;font-weight:700;letter-spacing:.05em;text-transform:uppercase;line-height:1.6;margin-right:5px;margin-bottom:5px;\"\u003eLimitation de la puissance d’exportation\u003c\/span\u003e\n\u003cspan style=\"display:inline-block;background:#1d4d1d;color:#ffffff;border:1.5px solid #1d4d1d;border-radius:4px;padding:3px 10px;font-size:11px;font-weight:700;letter-spacing:.05em;text-transform:uppercase;line-height:1.6;margin-right:5px;margin-bottom:5px;\"\u003eConformité aux exigences du gestionnaire de réseau de distribution\u003c\/span\u003e\n\u003cspan style=\"display:inline-block;background:#2e6e2e;color:#ffffff;border:1.5px solid #2e6e2e;border-radius:4px;padding:3px 10px;font-size:11px;font-weight:700;letter-spacing:.05em;text-transform:uppercase;line-height:1.6;margin-right:5px;margin-bottom:5px;\"\u003eCompteur d’importation\/exportation vers le réseau\u003c\/span\u003e\n\u003cspan style=\"display:inline-block;background:#e8850a;color:#ffffff;border:1.5px solid #e8850a;border-radius:4px;padding:3px 10px;font-size:11px;font-weight:700;letter-spacing:.05em;text-transform:uppercase;line-height:1.6;margin-right:5px;margin-bottom:5px;\"\u003eModule complémentaire pour onduleur Clearline\u003c\/span\u003e\n\u003cspan style=\"display:inline-block;background:#555555;color:#ffffff;border:1.5px solid #555555;border-radius:4px;padding:3px 10px;font-size:11px;font-weight:700;letter-spacing:.05em;text-transform:uppercase;line-height:1.6;margin-right:5px;margin-bottom:5px;\"\u003eModule Wi-Fi requis\u003c\/span\u003e\n\u003cspan style=\"display:inline-block;background:#ffffff;color:#2e6e2e;border:1.5px solid #2e6e2e;border-radius:4px;padding:3px 10px;font-size:11px;font-weight:700;letter-spacing:.05em;text-transform:uppercase;line-height:1.6;margin-right:5px;margin-bottom:5px;\"\u003eViridian Solar\u003c\/span\u003e\n\u003c\/p\u003e\n\n\u003cp style=\"font-size:15.5px;color:#2a2a2a;margin-bottom:1.4rem;line-height:1.8;\"\u003eLa \u003cstrong style=\"color:#1d4d1d;\"\u003esonde de courant Viridian pour onduleur Clearline\u003c\/strong\u003e (VIR-CSI-CT) est l’accessoire de transformateur de courant qui permet la \u003cstrong style=\"color:#1d4d1d;\"\u003elimitation de la puissance d’exportation\u003c\/strong\u003e sur les onduleurs Clearline CSI. Installée sur le câble d’alimentation principal du réseau électrique au niveau du tableau électrique, elle mesure en permanence le flux de puissance en temps réel au point de raccordement au réseau et transmet ces données à l’onduleur, qui ajuste dynamiquement sa puissance de sortie afin de respecter une limite d’exportation maximale configurée. Cela est indispensable lorsque votre \u003cstrong style=\"color:#1d4d1d;\"\u003eautorisation de raccordement délivrée par le gestionnaire de réseau de distribution (GRD)\u003c\/strong\u003e fixe une puissance d’exportation maximale autorisée — par exemple, une autorisation G98 avec une limite d’exportation de 3,68 kW ou une autorisation G99 avec un niveau d’exportation spécifique. La sonde de courant \u003cstrong style=\"color:#1d4d1d;\"\u003edoit être utilisée avec le module Wi-Fi VIR-CSI-WIFI\u003c\/strong\u003e — les deux sont nécessaires pour que la fonction de limitation de l’exportation fonctionne.\u003c\/p\u003e\n\n\u003cp style=\"background:#fdf0ed;border-left:4px solid #c0392b;border-radius:0 6px 6px 0;padding:.85rem 1.15rem;margin:.9rem 0;font-size:14.5px;line-height:1.7;color:#4a0800;\"\u003e🔴 \u003cstrong style=\"color:#1d4d1d;\"\u003eImportant :\u003c\/strong\u003e La sonde de courant doit être installée sur le \u003cstrong style=\"color:#1d4d1d;\"\u003ecâble d’alimentation du réseau\u003c\/strong\u003e (le conducteur sous tension entre le compteur électrique et le tableau électrique) par un \u003cstrong style=\"color:#1d4d1d;\"\u003eélectricien qualifié\u003c\/strong\u003e. Une installation incorrecte entraînera une mesure erronée de la puissance exportée et pourrait amener l’onduleur à exporter plus de puissance que ce qui est autorisé. \u003cstrong style=\"color:#1d4d1d;\"\u003eLe VIR-CSI-WIFI et le VIR-CSI-CT sont tous deux nécessaires pour limiter l’exportation — aucun des deux ne peut remplir cette fonction sans l’autre.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp style=\"font-size:10.5px;font-weight:800;letter-spacing:.14em;text-transform:uppercase;color:#2e6e2e;margin-top:1.7rem;margin-bottom:.55rem;padding-bottom:4px;border-bottom:2px solid #2e6e2e;\"\u003eCaractéristiques principales\u003c\/p\u003e\n\n\u003cul style=\"list-style:none;padding:0;margin:0 0 1.4rem 0;\"\u003e\n\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003ePermet de limiter la puissance d’exportation\u003c\/strong\u003e sur n’importe quel onduleur Clearline CSI — indispensable pour respecter les exigences du GRD lorsque votre autorisation de raccordement G98\/G99 fixe une limite d’exportation maximale\u003c\/li\u003e\n\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eInstallation par serrage\u003c\/strong\u003e — se fixe autour du conducteur sous tension (ou neutre) d’alimentation du réseau ; inutile de couper ou de raccorder le câble, ce qui réduit le temps d’installation\u003c\/li\u003e\n\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eSe connecte au port de communication RS485\/CT de l’onduleur\u003c\/strong\u003e — port dédié sur tous les modèles Clearline CSI ; aucun enregistreur de données ni compteur externe n’est nécessaire\u003c\/li\u003e\n\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eMesure en continu en temps réel\u003c\/strong\u003e — l’onduleur lit la sortie de la sonde de courant plusieurs fois par seconde et ajuste sa puissance de sortie CA en temps réel afin de maintenir le point de consigne d’exportation\u003c\/li\u003e\n\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eDéfinition de la limite d’exportation via l’application WE Mate\u003c\/strong\u003e — l’installateur configure le niveau de puissance d’exportation cible (en watts) dans Paramètres avancés → Limite de puissance ; l’onduleur maintient automatiquement cette limite\u003c\/li\u003e\n\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eFonctionnement sans exportation\u003c\/strong\u003e — définissez la limite d’exportation sur 0 W si votre GRD ou votre autorisation de raccordement ne permet aucune exportation (mode d’autoconsommation uniquement)\u003c\/li\u003e\n\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eCompatible avec tous les modèles Clearline CSI\u003c\/strong\u003e — compatible avec tous les onduleurs Clearline monophasés, du CSI1000S au CSI6000D\u003c\/li\u003e\n\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eDoit être utilisé avec le VIR-CSI-WIFI ou le VIR-CSI-WIFI-S\u003c\/strong\u003e — le module Wi-Fi assure la liaison entre la mesure de la sonde de courant et l’algorithme de régulation de puissance de l’onduleur\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp style=\"font-size:10.5px;font-weight:800;letter-spacing:.14em;text-transform:uppercase;color:#2e6e2e;margin-top:1.7rem;margin-bottom:.55rem;padding-bottom:4px;border-bottom:2px solid #2e6e2e;\"\u003eQuand faut-il une sonde de courant ?\u003c\/p\u003e\n\n\u003cp style=\"background:#fef3e2;border-left:4px solid #e8850a;border-radius:0 6px 6px 0;padding:.85rem 1.15rem;margin:.9rem 0;font-size:14.5px;line-height:1.7;color:#4a2800;\"\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eVous avez besoin de la sonde de courant si votre autorisation de raccordement délivrée par le GRD (G98 ou G99) inclut l’une des conditions suivantes :\u003c\/strong\u003e\n\n• Une puissance d’exportation maximale autorisée (par ex. 3,68 kW, 2 kW ou 0 kW)\n• Une exigence de limitation de l’exportation ou de fonctionnement sans exportation\n• Une condition stipulant que la puissance de sortie de l’onduleur doit être bridée en fonction des conditions du réseau\n\nSi votre autorisation de raccordement ne comporte aucune restriction d’exportation, la sonde de courant n’est pas nécessaire. Consultez votre lettre d’offre de raccordement du GRD ou demandez conseil à votre installateur certifié MCS.\u003c\/p\u003e\n\n\u003cp style=\"font-size:10.5px;font-weight:800;letter-spacing:.14em;text-transform:uppercase;color:#2e6e2e;margin-top:1.7rem;margin-bottom:.55rem;padding-bottom:4px;border-bottom:2px solid #2e6e2e;\"\u003eCaractéristiques techniques\u003c\/p\u003e\n\n\u003cdiv style=\"overflow-x:auto;margin-bottom:1.5rem;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:13.5px;min-width:360px;\"\u003e\n\n\u003ctr\u003e\n\n\u003cth style=\"background:#1d4d1d;color:#ffffff;font-weight:700;text-align:left;padding:7px 11px;\"\u003eCaractéristique\u003c\/th\u003e\n\n\u003cth style=\"background:#1d4d1d;color:#ffffff;font-weight:700;text-align:left;padding:7px 11px;\"\u003eValeur\u003c\/th\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;font-weight:600;color:#1d4d1d;\"\u003eFonction\u003c\/td\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;\"\u003eTransformateur de courant pour mesure en temps réel de l’importation\/exportation vers le réseau\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;font-weight:600;color:#1d4d1d;\"\u003ePoint d’installation\u003c\/td\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;\"\u003eCâble d’alimentation du réseau entre le compteur électrique et le tableau électrique\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;font-weight:600;color:#1d4d1d;\"\u003eMéthode d’installation\u003c\/td\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;\"\u003ePar serrage (transformateur de courant à noyau fendu) — aucune coupe du câble n’est nécessaire\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;font-weight:600;color:#1d4d1d;\"\u003eConnexion à l’onduleur\u003c\/td\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;\"\u003ePort de communication RS485\/CT (port COM 2 sur tous les modèles Clearline CSI)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;font-weight:600;color:#1d4d1d;\"\u003eAccessoire requis\u003c\/td\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;\"\u003eModule Wi-Fi VIR-CSI-WIFI ou VIR-CSI-WIFI-S (doit être installé pour que la limitation de l’exportation fonctionne)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;font-weight:600;color:#1d4d1d;\"\u003eConfiguration\u003c\/td\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;\"\u003eVia l’application WE Mate → Paramètres avancés → Limite de puissance → Activer la limite de puissance → Définir la puissance d’exportation et le rapport de la sonde de courant\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;font-weight:600;color:#1d4d1d;\"\u003eOnduleurs compatibles\u003c\/td\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;\"\u003eToute la gamme Viridian Clearline CSI (CSI1000S–CSI6000D)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;font-weight:600;color:#1d4d1d;\"\u003eExigence pour l’installateur\u003c\/td\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;\"\u003eÉlectricien qualifié — l’installation au niveau du tableau électrique implique des équipements sous tension\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;font-weight:600;color:#1d4d1d;\"\u003eFabricant\u003c\/td\u003e\n\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;\"\u003eViridian Solar Ltd, Papworth, Cambridge\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003cp style=\"font-size:10.5px;font-weight:800;letter-spacing:.14em;text-transform:uppercase;color:#2e6e2e;margin-top:1.7rem;margin-bottom:.55rem;padding-bottom:4px;border-bottom:2px solid #2e6e2e;\"\u003eFoire aux questions\u003c\/p\u003e\n\n\u003cp style=\"border-bottom:1px solid #c8e6c8;padding:.85rem 0 .85rem 1.4rem;position:relative;margin:0;\"\u003e\u003cspan style=\"position:absolute;left:0;top:.85rem;color:#2e6e2e;font-weight:900;font-size:14.5px;\"\u003eQ\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;font-size:14.5px;\"\u003eAi-je besoin d’une sonde de courant si mon autorisation de raccordement délivrée par le GRD ne comporte aucune restriction d’exportation ?\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;color:#2a2a2a;line-height:1.7;\"\u003eNon. Si votre autorisation de raccordement G98 ou G99 n’impose aucune restriction sur la puissance d’exportation, la sonde de courant n’est pas nécessaire. La plupart des installations domestiques simples G98 inférieures à 3,68 kW peuvent exporter librement. Consultez votre document d’offre de raccordement du GRD pour vérifier si une limite d’exportation s’applique.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"border-bottom:1px solid #c8e6c8;padding:.85rem 0 .85rem 1.4rem;position:relative;margin:0;\"\u003e\u003cspan style=\"position:absolute;left:0;top:.85rem;color:#2e6e2e;font-weight:900;font-size:14.5px;\"\u003eQ\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;font-size:14.5px;\"\u003ePuis-je utiliser la sonde de courant sans le module Wi-Fi ?\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;color:#2a2a2a;line-height:1.7;\"\u003eNon. \u003cstrong style=\"color:#1d4d1d;\"\u003eLe VIR-CSI-CT et le VIR-CSI-WIFI doivent être utilisés ensemble pour limiter l’exportation.\u003c\/strong\u003e La sonde de courant mesure l’intensité ; le module Wi-Fi transmet cette mesure au système de régulation de l’onduleur. Sans le module Wi-Fi, l’onduleur ne peut pas lire les données de la sonde de courant.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"border-bottom:1px solid #c8e6c8;padding:.85rem 0 .85rem 1.4rem;position:relative;margin:0;\"\u003e\u003cspan style=\"position:absolute;left:0;top:.85rem;color:#2e6e2e;font-weight:900;font-size:14.5px;\"\u003eQ\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;font-size:14.5px;\"\u003eOù la sonde de courant est-elle exactement installée ?\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;color:#2a2a2a;line-height:1.7;\"\u003eLa sonde de courant est installée sur le \u003cstrong style=\"color:#1d4d1d;\"\u003econducteur principal d’alimentation du réseau\u003c\/strong\u003e — généralement le câble sous tension (phase) entre votre compteur électrique et le tableau électrique principal. Cela lui permet de mesurer la puissance totale circulant vers ou depuis le réseau (importation et exportation). L’installation à cet endroit doit être effectuée par un électricien qualifié.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"border-bottom:1px solid #c8e6c8;padding:.85rem 0 .85rem 1.4rem;position:relative;margin:0;\"\u003e\u003cspan style=\"position:absolute;left:0;top:.85rem;color:#2e6e2e;font-weight:900;font-size:14.5px;\"\u003eQ\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;font-size:14.5px;\"\u003ePuis-je configurer un fonctionnement sans exportation (autoconsommation uniquement) ?\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;color:#2a2a2a;line-height:1.7;\"\u003eOui. Définissez la limite d’exportation sur \u003cstrong style=\"color:#1d4d1d;\"\u003e0 W\u003c\/strong\u003e dans l’application WE Mate sous Paramètres avancés → Limite de puissance. L’onduleur ajustera alors en permanence sa puissance de sortie afin de correspondre à la consommation du foyer, empêchant ainsi toute puissance de revenir vers le réseau. Notez que le fonctionnement sans exportation ne peut être garanti dans toutes les conditions dynamiques — le temps de réponse peut entraîner de légères exportations transitoires occasionnelles ; cela est normal et accepté par la plupart des GRD.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp style=\"border-bottom:1px solid #c8e6c8;padding:.85rem 0 .85rem 1.4rem;position:relative;margin:0;\"\u003e\u003cspan style=\"position:absolute;left:0;top:.85rem;color:#2e6e2e;font-weight:900;font-size:14.5px;\"\u003eQ\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;font-size:14.5px;\"\u003eQue se passe-t-il si le câble de la sonde de courant est déconnecté après la mise en service ?\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;color:#2a2a2a;line-height:1.7;\"\u003eSi la communication avec la sonde de courant est perdue, l’onduleur repassera généralement à une puissance de sortie nominale sans restriction. Cela peut entraîner un dépassement de la limite d’exportation. Veillez à ce que le câble de la sonde soit acheminé et fixé afin d’éviter toute déconnexion accidentelle, et vérifiez l’application WE Mate pour détecter d’éventuelles alertes de défaut de communication.\u003c\/span\u003e\u003c\/p\u003e\n\n\n\n\u003c\/div\u003e","brand":"Viridian Solar","offers":[{"title":"Default Title","offer_id":63646266294621,"sku":"VIR-CSI-CT","price":69.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Fox-ESS-CT-Clampwithcable.jpg?v=1765171650","url":"https:\/\/qualityheating.co.uk\/fr\/products\/viridian-ct-clamp-for-clearline-inverter-vir-csi-ct-export-power-limiting-dno-compliance-g98-g99-export-cap-requires-vir-csi-wifi","provider":"AIZO Quality Heating","version":"1.0","type":"link"}