{"title":"Solar Cables, Battery Cables \u0026 Connectors","description":"\u003cp\u003eExplore our premium collection featuring top-quality solar cables from Cableworld, robust battery cables, and reliable Stäubli MC4 connectors. Perfectly suited for photovoltaic installations and energy storage systems, these components ensure safe, efficient power transfer and robust connections. Whether you’re wiring solar panels, linking battery banks, or creating secure connector joints, this collection offers durable, weatherproof electrical solutions designed to meet industry standards and provide lasting performance.\u003c\/p\u003e","products":[{"product_id":"battery-hazard-warning-label","title":"Battery Hazard Warning Label Pack","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance with International Shipping Regulations:\u003c\/strong\u003e Designed for lithium battery shipments to meet IATA, ADR, IMDG, and RID requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLabel Size and Visibility:\u003c\/strong\u003e Includes self-adhesive labels sized approximately 100mm x 100mm with red hatched border and clear black text for high visibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability:\u003c\/strong\u003e Printed on semi-gloss paper with permanent acrylic adhesive ensuring labels remain legible and intact through handling and transport.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Information:\u003c\/strong\u003e Labels include UN lithium battery mark (e.g., UN3480 or UN3481), telephone number space for emergency contact, and handling instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultipurpose Pack:\u003c\/strong\u003e Suitable for various lithium battery types including those packed with or contained in equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMCS and Dangerous Goods Safety Compliance:\u003c\/strong\u003e Essential for professional battery packers and shippers to ensure safe and legal transport.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy This Label Pack?\u003c\/h3\u003e\n\u003cp\u003eEnsure your lithium battery shipments are fully compliant with the latest regulations and safety standards by using this comprehensive Battery Hazard Label Pack. Clear, durable, and professionally designed labels reduce handling risks and aid efficient processing by carriers and customs officials. This pack supports peace of mind for businesses shipping lithium batteries domestically or internationally.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBAT-HAZ-PACK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLabel Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 100mm x 100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePaper Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSemi-gloss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdhesive Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePermanent acrylic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePack size varies; suitable for multiple shipments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIATA, ADR, IMDG, RID regulations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"AIZO - Quality Heating","offers":[{"title":"Default Title","offer_id":58693525799261,"sku":"BAT-HAZ-PACK","price":7.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/BatteryHazardLabelPack.png?v=1763458168"},{"product_id":"solar-cable-4mma-single-core-black-100m","title":"Solar Cable 4mm² Single-Core DC Cable - 100m, Black","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eSolar Cable 4mm² Single-Core DC Cable - 100m, Black\u003c\/h2\u003e\n\u003cp\u003eThe CABLE4-1-100 is a high-quality 4mm² single-core DC solar cable, supplied in a 100-meter length with black UV-resistant PVC insulation. Engineered specifically for photovoltaic (PV) and renewable energy systems, this cable features a flexible, stranded, tinned copper conductor for durability and excellent conductivity. Rated for system voltages up to 1500 V DC and suitable for currents up to 32-55 A depending on installation conditions, it supports safe and efficient power transfer in solar arrays. The sheath is halogen-free, flame-retardant, and resistant to UV, water, oils, and chemicals, ensuring long service life in outdoor conditions. It complies with European standards EN 50618 and H1Z2Z2-K for PV cables, making it ideal for roof and ground-mounted solar installations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePart No: CABLE4-1-100\u003c\/li\u003e\n\u003cli\u003eLength: 100 meters\u003c\/li\u003e\n\u003cli\u003eCable type: Single-core DC solar cable\u003c\/li\u003e\n\u003cli\u003eCross-sectional area: 4 mm²\u003c\/li\u003e\n\u003cli\u003eConductor: Flexible tinned copper (Class 5)\u003c\/li\u003e\n\u003cli\u003eSheath: Black, UV-resistant, halogen-free PVC\u003c\/li\u003e\n\u003cli\u003eVoltage rating: Up to 1500 V DC\u003c\/li\u003e\n\u003cli\u003eCurrent rating: 32-55 A (installation dependent)\u003c\/li\u003e\n\u003cli\u003eStandards: EN 50618, H1Z2Z2-K certified\u003c\/li\u003e\n\u003cli\u003eTemperature range: -40°C to +90°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"seo-keywords\"\u003e\n\u003cul\u003e\n\u003cli\u003e4mm² single-core solar cable black\u003c\/li\u003e\n\u003cli\u003eCABLE4-1-100 DC solar cable 100m\u003c\/li\u003e\n\u003cli\u003etinned copper flexible solar cable 4 mm²\u003c\/li\u003e\n\u003cli\u003eUV resistant DC cable for PV systems\u003c\/li\u003e\n\u003cli\u003eEN 50618 certified solar PV cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Cableworld","offers":[{"title":"Default Title","offer_id":58693525832029,"sku":"SolarCable-4mm-100m","price":85.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SolarCable4mm_Single-CoreDCCable-100m_Black.png?v=1762448450"},{"product_id":"staubli-mc4-basic-crimping-tool-2-5-4-6mm2","title":"Staubli MC4 Basic Crimping Tool - 2.5\/4\/66mm²","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eMC4 Basic Crimping Pliers 2.5\/4\/6mm²\u003c\/h2\u003e\n\u003cp\u003eThe MC4-CRIMP-TOOL is a simple yet effective crimping pliers designed for reliable connection of standard MC4 solar connectors with cable diameters of 2.5 mm², 4 mm², and 6 mm². It features a ratchet mechanism for consistent, process-safe crimps and opens only after the proper crimping cycle is complete. This basic tool is ideal for small-scale installations or private use and supports assembly of TÜV-approved products. Note that it is not suitable for MC4-Evo2 connectors. The ergonomic two-component handles ensure comfortable, slip-resistant grip for precise and fatigue-free operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePart No: MC4-CRIMP-TOOL\u003c\/li\u003e\n\u003cli\u003eCrimp sizes: 2.5, 4.0, and 6.0 mm² cable diameters\u003c\/li\u003e\n\u003cli\u003eRatchet mechanism ensures consistent crimps\u003c\/li\u003e\n\u003cli\u003eErgonomic non-slip handles\u003c\/li\u003e\n\u003cli\u003eDesigned for standard MC4 connectors only (not for MC4-Evo2)\u003c\/li\u003e\n\u003cli\u003eSuitable for small quantities and private use\u003c\/li\u003e\n\u003cli\u003eLightweight and portable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"seo-keywords\"\u003e\n\u003cul\u003e\n\u003cli\u003eMC4 Basic Crimping Pliers 2.5 4 6mm2\u003c\/li\u003e\n\u003cli\u003eMC4-CRIMP-TOOL solar connector crimper\u003c\/li\u003e\n\u003cli\u003esolar cable crimp pliers MC4 connectors\u003c\/li\u003e\n\u003cli\u003ePV crimping tool standard MC4 cables\u003c\/li\u003e\n\u003cli\u003eergonomic solar crimping pliers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Staubli","offers":[{"title":"Default Title","offer_id":58693525963101,"sku":"MC4-CRIMP-TOOL","price":135.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Staubli-MC4-Basic-Crimping-Tool.jpg?v=1762443936"},{"product_id":"solar-dc-cable-6mma-single-core-black-100m","title":"Solar DC Cable 6mm² Single-Core 100m - Black","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Cross-Section: 6 mm²\u003c\/strong\u003e — ensures optimal current capacity and low voltage drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage: 1800 V DC\u003c\/strong\u003e — suitable for high-voltage photovoltaic (PV) systems and other direct current applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current: 32 A\u003c\/strong\u003e (DIN VDE 0298 part 4 compliant) — guarantees reliable current carrying capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range: -40°C to +90°C\u003c\/strong\u003e — remains resilient under extreme environmental conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectron Beam Cross-Linked Sheathing\u003c\/strong\u003e — provides superior resistance to UV, ozone, ammonia, acids, mineral oils, and physical wear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcellent Fire Resistance\u003c\/strong\u003e — enhances safety in installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Tin-Coated Copper Conductors\u003c\/strong\u003e — for easy handling and longevity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour: Black\u003c\/strong\u003e — professional, discreet finish suitable for visible installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy This Cable?\u003c\/h3\u003e\n\u003cp\u003eThis 6mm² single-core cable is ideal for solar PV systems, electric vehicles, charging stations, and other DC power applications. Its robust construction meets the latest European standard EN 50618 (H1Z2Z2-K), ensuring low smoke and zero halogen characteristics that improve safety in case of fire. The cable's high voltage and temperature rating provide peace of mind for both residential and commercial installations, making it a dependable choice for long-term performance and compliance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCABLE6-1-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 (Single-Core)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSheathing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectron beam cross-linked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTin-coated copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (approx.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Cableworld","offers":[{"title":"Default Title","offer_id":58693528289629,"sku":"SolarCable-6mm-100m","price":130.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/H1Z2Z2-K-Solar-PV-Cable.webp?v=1763454213"},{"product_id":"pv-ultra-tuff-sheath-solar-cable-4mma-4-core-solartek-black-per-1-mtr","title":"4mm2 Four Core DC Cable 25m, SolarTek, PV Ultra Tuff Sheath Solar Cable","description":"\u003ch2\u003e4mm2 Four Core DC Cable 25m - Two Red and Two Black\u003c\/h2\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Cross-Section: 4 mm² per core\u003c\/strong\u003e — ensures efficient current transmission with minimal voltage drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour Core Design (Two Red and Two Black cores)\u003c\/strong\u003e — perfect for complex DC circuits and clear polarity identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage: 1500 V DC (Max 1800 V DC)\u003c\/strong\u003e — suitable for demanding solar photovoltaic (PV) and other DC electrical applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current: Up to 44 A\u003c\/strong\u003e — supports reliable power delivery for moderate load installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range: -40°C to +90°C (withstand up to 120°C for limited hours)\u003c\/strong\u003e — built to perform in harsh environmental conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble Insulated, Low Smoke Halogen Free (LSHF) XLPE Sheath\u003c\/strong\u003e — offers excellent fire safety, UV resistance, and chemical protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Tinned Copper Conductors\u003c\/strong\u003e — designed for ease of handling and long-lasting durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarbonTek® Bedding and SolarTek® Outer Sheath\u003c\/strong\u003e — enhances mechanical protection and lifespan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in High-Tensile Rip Cord\u003c\/strong\u003e — facilitates easy and safe sheath stripping without damaging conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliant with EN 50618 (H1Z2Z2-K) Standard\u003c\/strong\u003e — ensuring suitability for photovoltaic DC systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy This Cable?\u003c\/h3\u003e\n\u003cp\u003eThe 4mm² four core DC cable is designed for photovoltaic (PV) system interconnections, offering superior resistance to UV, abrasion, and fire. Its double insulated construction ensures Class II or equivalent safety ratings according to UK wiring regulations (BS7671). This cable enables swift, cost-effective installations without the need for additional conduit or armouring, reducing installation time and complexity. Perfect for professional solar panel installers and renewable energy projects demanding safe, reliable DC cabling.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-PV-ULTRA4C4.0-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (Two Red and Two Black)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 mm² per core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 V DC (Max 1800 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 44 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +90°C (up to 120°C for 20,000 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSheath Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Insulated Low Smoke Halogen Free XLPE, CarbonTek® Bedding, SolarTek® Outer Sheath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible Tinned Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in High-Tensile Rip Cord for easy stripping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 50618 (H1Z2Z2-K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Doncaster Cables","offers":[{"title":"Default Title","offer_id":58693531566429,"sku":"PV-ULTRA4C4.0","price":250.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/DoncasterPV-Ultra-DoubleInsulatedMulticoreDCCable.jpg?v=1763456003"},{"product_id":"6mm2-four-core-dc-cable-25m-solartek-pv-ultra-tuff-sheath-solar-cable","title":"6mm2 Four Core DC Cable 25m, SolarTek, PV Ultra Tuff Sheath Solar Cable","description":"\u003ch2\u003e6mm2 Four Core DC Solar Cable 25m - Two Red and Two Black\u003c\/h2\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Cross-Section: 6 mm² per core\u003c\/strong\u003e — supports efficient current flow with minimal voltage drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour Core Design (Two Red and Two Black cores)\u003c\/strong\u003e — ideal for multiple DC circuits or balanced load connections in PV systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage: 1800 V DC\u003c\/strong\u003e — designed for high-voltage photovoltaic (PV) system requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current: Up to 57 A\u003c\/strong\u003e — suitable for demanding DC power applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range: -40°C to +90°C (withstanding up to 120°C for limited hours)\u003c\/strong\u003e — ensures reliable operation in harsh environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble Insulated, Low Smoke Halogen Free (LSHF) XLPE Sheath\u003c\/strong\u003e — provides excellent fire safety, UV resistance, and chemical protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Tinned Copper Conductors\u003c\/strong\u003e — facilitates easy installation and long-term durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarbonTek® Bedding and SolarTek® Outer Sheath\u003c\/strong\u003e — enhances mechanical protection and longevity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour Coding:\u003c\/strong\u003e Two cores red, two cores black for clear and safe polarity identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplies with EN 50618 (H1Z2Z2-K) Standard\u003c\/strong\u003e — ensures suitability for photovoltaic DC systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in high-tensile rip cord\u003c\/strong\u003e — simplifies cable stripping without damaging conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Buy This Cable?\u003c\/h3\u003e\n\n\u003cp\u003eThis 6mm² four core DC cable provides a high-quality solution for complex solar PV installations requiring multiple live conductors. Its robust construction and double insulation meet the latest safety and performance standards, including low smoke, zero halogen, and high-temperature tolerance. Designed for ease of installation and longevity, it reduces the need for additional conduit or junction boxes, saving installation time and cost. Ideal for professional solar PV installers and renewable energy projects that demand reliable and safe DC power cabling.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-PV-ULTRA4C6.0-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (Two Red and Two Black)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 mm² per core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1800 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 57 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +90°C (up to 120°C for 20,000 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSheath Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Insulated Low Smoke Halogen Free XLPE, CarbonTek® Bedding, SolarTek® Outer Sheath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible Tinned Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo Red and Two Black cores\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in high-tensile rip cord for easy stripping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 50618 (H1Z2Z2-K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Doncaster Cables","offers":[{"title":"Default Title","offer_id":58693531599197,"sku":"PV-ULTRA4C6.0","price":295.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/DoncasterPV-Ultra-DoubleInsulatedMulticoreDCCable.jpg?v=1763456003"},{"product_id":"4mm2-two-core-dc-cable-25m-red-and-black-solartek-pv-ultra-tuff-sheath-solar-cable","title":"4mm2 Two Core DC Cable 25m - Red and Black, SolarTek PV Ultra Tuff Sheath Solar Cable","description":"\u003ch2\u003e4mm2 Two Core DC Cable 25m - Red and Black\u003c\/h2\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Cross-Section: 4 mm² per core\u003c\/strong\u003e — ideal for efficient current transmission with low voltage drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo Core Design (Red and Black)\u003c\/strong\u003e — facilitates easy identification of positive and negative DC connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage: 1500 V DC (Max 1800 V DC)\u003c\/strong\u003e — suitable for solar PV systems and other high-voltage DC applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current: Up to 52 A\u003c\/strong\u003e — supports a wide range of DC power requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range: -40°C to +90°C\u003c\/strong\u003e — reliable performance in extreme weather conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble Insulated, Electron Beam Cross-Linked XLPE Sheath\u003c\/strong\u003e — providing excellent resistance to UV, ozone, abrasion, and chemical exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Tinned Copper Conductors\u003c\/strong\u003e — ensures ease of installation and enhanced durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour Coding:\u003c\/strong\u003e Red and Black cores for clear polarity distinction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy This Cable?\u003c\/h3\u003e\n\u003cp\u003eThis 4mm² two core DC cable is built to meet the high standards of solar photovoltaic systems and other direct current applications. It complies with EN 50618 (H1Z2Z2-K) standard, offering safety features like low smoke and zero halogen emissions in case of fire. Its robust double insulation and flexible construct make it perfect for long-lasting, safe, and efficient installations in residential, commercial, and renewable energy projects.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-PV-ULTRA2C4.0-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (Red and Black)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 mm² per core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 V DC (Max 1800 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 52 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSheath Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectron Beam Cross-Linked XLPE (LSZH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed and Black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Doncaster Cables","offers":[{"title":"Default Title","offer_id":58693531631965,"sku":"PV-ULTRA2C4.0","price":175.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/DoncasterPV-Ultra-DoubleInsulatedMulticoreSolarDCCable.png?v=1763456003"},{"product_id":"pv-on-roof-and-hazard-labels-pack","title":"PV on Roof and Hazard Labels Pack","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Label Set:\u003c\/strong\u003e Combination pack containing both general hazard labels and specific \"PV on Roof\" hazard labels for solar installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Durability:\u003c\/strong\u003e Self-adhesive, thick polyolefin material designed to endure harsh outdoor environmental conditions including UV exposure and weathering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance:\u003c\/strong\u003e Labels comply with ISO 7010 safety and hazard communication standards, ensuring industry-recognised safety marking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear and Visible:\u003c\/strong\u003e Bright colours and bold graphics designed to provide clear warnings and improve safety for installers, maintenance personnel, and emergency responders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Application:\u003c\/strong\u003e Peel and stick backing enables quick and reliable attachment to roofs, control boxes, junction boxes, and system components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Use:\u003c\/strong\u003e Suitable for residential, commercial, and industrial photovoltaic systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003ePV on Roof and Hazard Labels Pack\u003c\/strong\u003e offers an all-in-one solution to meet safety labelling requirements for solar PV systems. It improves hazard awareness and helps ensure regulatory compliance, minimising risks associated with photovoltaic installations. This pack is essential for professional installers, contractors, and system operators committed to safety and best practice in solar power deployment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBOHAZARD-SET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-adhesive polyolefin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLabel Sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 100mm x 100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 7010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncludes hazard warning labels and PV on Roof safety labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"AIZO - Quality Heating","offers":[{"title":"Default Title","offer_id":58693531795805,"sku":"BOHAZARD-SET","price":4.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/PVonRoofandHazardLabelsPack.png?v=1763458455"},{"product_id":"6mm2-two-core-dc-cable-25m-red-and-black-pv-ultra-tuff-sheath-solar-cable","title":"6mm2 Two Core DC Cable 25m - Red and Black PV Ultra Tuff Sheath Solar Cable","description":"\u003ch2\u003e6mm2 Two Core DC Cable 25m - Red and Black\u003c\/h2\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Cross-Section: 6 mm² per core\u003c\/strong\u003e — supports efficient current flow with minimal voltage drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo Core Design (Red and Black)\u003c\/strong\u003e — ideal for positive and negative connections in DC circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage: 1500 V DC (Max 1800 V DC)\u003c\/strong\u003e — perfect for solar PV systems and other direct current applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current: Up to 57 A\u003c\/strong\u003e (depending on installation) — suitable for high power DC installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range: -40°C to +90°C\u003c\/strong\u003e — robust for extreme environmental conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Performance Double Insulation\u003c\/strong\u003e — low-smoke zero-halogen (LSZH), flame and UV resistant for outdoor longevity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectron Beam Cross-Linked XLPE Sheath\u003c\/strong\u003e — superior chemical, ozone, and abrasion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Tinned Copper Conductors\u003c\/strong\u003e — for ease of installation and durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour Coding:\u003c\/strong\u003e Red and Black cores for clear polarity identification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy This Cable?\u003c\/h3\u003e\n\u003cp\u003eThis 6mm² two core DC cable is specifically designed for solar photovoltaic systems, providing outstanding resistance to fire, UV radiation, and harsh outdoor conditions. It meets the stringent EN 50618 (H1Z2Z2-K) standard for solar cables, ensuring safety and longevity in demanding environments. The double insulated, flexible design facilitates clean and safe installation of DC power lines where reliability is paramount. Perfect for renewable energy setups, electric vehicle charging, and other high-voltage DC power applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-PV-ULTRA2C6.0-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (Red and Black)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 mm² per core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 V DC (Max 1800 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 57 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSheath Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectron Beam Cross-Linked XLPE (LSZH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed and Black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Doncaster Cables","offers":[{"title":"Default Title","offer_id":58693531861341,"sku":"PV-ULTRA2C6.0","price":195.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/DoncasterPV-Ultra-DoubleInsulatedMulticoreSolarDCCable.png?v=1763456003"},{"product_id":"mc4-pre-terminated-cable-2m-pack-of-2","title":"Staubli MC4 Pre Terminated Cable 2m (Pack of 2)","description":"\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Terminated with MC4 Connectors:\u003c\/strong\u003e Comes with male and female MC4 connectors for quick plug-and-play installation in solar PV systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 2 metres per cable, ideal for short connections between solar panels or to inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Cross-Section:\u003c\/strong\u003e 4 mm² high-quality tinned copper conductor for excellent conductivity and durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current:\u003c\/strong\u003e Rated up to 44A, suitable for most residential and commercial photovoltaic setups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather and UV Resistant:\u003c\/strong\u003e Cable and connectors designed for long-lasting outdoor use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePack Includes:\u003c\/strong\u003e 2 pre-terminated cables (one with male MC4 connector, one with female MC4 connector).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy This Product?\u003c\/h3\u003e\n\u003cp\u003eThis pair of MC4 pre-terminated cables provides a convenient and reliable solution for solar panel wiring, reducing installation time and ensuring secure, waterproof electrical connections. Perfect for both installers and DIY solar enthusiasts, the cables are compliant with international photovoltaic standards and compatible with most solar panel models, guaranteeing performance and safety.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMC4-2M-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength per Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMC4 Male and Female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePack of 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Staubli","offers":[{"title":"Default Title","offer_id":58693531959645,"sku":"MC4-2M-2PACK","price":17.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/MC4Preterminatedcable2mPackof2.webp?v=1771929600"},{"product_id":"sta-ubli-mc4-female-connector-single","title":"Staubli MC4 Female Connector - Single","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eMC4 Female Connector - 0014 Single - 6 mm²\u003c\/h2\u003e\n\u003cp\u003eThe MC4-14-FEM is a high-quality single MC4 female connector designed for photovoltaic systems using 6 mm² cable. Featuring a secure snap-in lock and a safety lock clip compliant with NEC 2011 standards, this connector ensures stable and safe connections that can only be released with a special tool. Built with proven MULTILAM technology for long-term stability, it provides consistently low power loss throughout its lifetime. Made from UV-resistant, weatherproof plastic with tinned copper contacts and stainless steel clips, it is rated for up to 39 A current and 1500 V DC voltage, making it ideal for reliable outdoor solar panel connections.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePart No: MC4-14-FEM\u003c\/li\u003e\n\u003cli\u003eSuitable for 6 mm² cable cross-section\u003c\/li\u003e\n\u003cli\u003eSnap-in lock with safety lock clip (requires tool for release)\u003c\/li\u003e\n\u003cli\u003eProven MULTILAM contact technology for low power loss\u003c\/li\u003e\n\u003cli\u003eRated current: 39 A, Rated voltage: 1500 V DC\u003c\/li\u003e\n\u003cli\u003eMaterial: UV-resistant thermoplastic housing, tinned copper contacts, stainless steel clips\u003c\/li\u003e\n\u003cli\u003eWeatherproof with IP67 rating\u003c\/li\u003e\n\u003cli\u003eCompatible with standard MC4 connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"seo-keywords\"\u003e\n\u003cul\u003e\n\u003cli\u003eMC4 Female Connector 6mm2\u003c\/li\u003e\n\u003cli\u003eMC4-14-FEM solar connector single\u003c\/li\u003e\n\u003cli\u003esolar panel MC4 female plug\u003c\/li\u003e\n\u003cli\u003ephotovoltaic MC4 connector 6 mm²\u003c\/li\u003e\n\u003cli\u003eMULTILAM MC4 female clip weatherproof\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Staubli","offers":[{"title":"Default Title","offer_id":58693532451165,"sku":"MC4-14-FEM","price":1.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/MC4FemaleConnector-0014Single-6mm2.webp?v=1762445526"},{"product_id":"sta-ubli-mc4-male-connector-single","title":"Staubli MC4 Male Connector - Single","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eStaubli MC4 Male Connector - 0015 Single - 6 mm²\u003c\/h2\u003e\n\u003cp\u003eThe Staubli MC4-15-MAL is a high-quality single MC4 male connector designed for photovoltaic systems utilizing 6 mm² cable. It features a secure snap-in locking mechanism complemented by a safety lock clip in accordance with NEC 2011 standards, ensuring connections are secure and can only be released with a special tool. Manufactured with proven MULTILAM technology, it offers excellent long-term stability and maintains low power loss across its lifespan. This connector is made from UV-resistant, weatherproof thermoplastic housing with tinned copper contacts and stainless steel clips, rated for 39 A current and 1500 V DC voltage, suitable for durable outdoor solar panel installations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePart No: MC4-15-MAL\u003c\/li\u003e\n\u003cli\u003eSuitable for 6 mm² cable cross-section\u003c\/li\u003e\n\u003cli\u003eSnap-in lock with safety lock clip (tool required for release)\u003c\/li\u003e\n\u003cli\u003eProven MULTILAM contact technology\u003c\/li\u003e\n\u003cli\u003eRated current: 39 A, voltage: 1500 V DC\u003c\/li\u003e\n\u003cli\u003eUV-resistant thermoplastic housing, tinned copper contacts\u003c\/li\u003e\n\u003cli\u003eWeatherproof with IP67 rating\u003c\/li\u003e\n\u003cli\u003eCompatible with standard MC4 connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"seo-keywords\"\u003e\n\u003cul\u003e\n\u003cli\u003eMC4 Male Connector 6mm2\u003c\/li\u003e\n\u003cli\u003eMC4-15-MAL solar connector single\u003c\/li\u003e\n\u003cli\u003ephotovoltaic MC4 male plug\u003c\/li\u003e\n\u003cli\u003eMULTILAM MC4 male clip weatherproof\u003c\/li\u003e\n\u003cli\u003esolar panel MC4 male connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Staubli","offers":[{"title":"Default Title","offer_id":58693532483933,"sku":"MC4-15-MAL","price":1.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/StaubliMC4MaleConnector-Single.jpg?v=1762445790"},{"product_id":"keto-battery-disconnector-with-2-x-100a-fuses","title":"Jean Muller KETO Battery Disconnector with 2 x 100A Fuses","description":"\u003cp\u003eThe Jean Muller KETO-00-100A fuse-switch-disconnector is a reliable battery isolator specifically designed for secure DC circuit protection in large battery storage and solar PV systems. This unit combines a compact size 00 switch body with high-quality 100A NH fuse-links (included) for safe and effective battery disconnection.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 135.179%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 7.67481%;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"width: 6.74854%;\"\u003ePoles\u003c\/th\u003e\n\u003cth style=\"width: 8.86573%;\"\u003eRated Current\u003c\/th\u003e\n\u003cth style=\"width: 8.86573%;\"\u003eDC Voltage Rating\u003c\/th\u003e\n\u003cth style=\"width: 9.792%;\"\u003eFuse-links Included\u003c\/th\u003e\n\u003cth style=\"width: 10.5859%;\"\u003eTerminals\u003c\/th\u003e\n\u003cth style=\"width: 8.07179%;\"\u003eCable Area\u003c\/th\u003e\n\u003cth style=\"width: 12.4385%;\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003cth style=\"width: 11.1152%;\"\u003eMounting\u003c\/th\u003e\n\u003cth style=\"width: 8.60108%;\"\u003eWeight\u003c\/th\u003e\n\u003cth style=\"width: 7.27784%;\"\u003eMPN\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 7.67481%;\"\u003e\u003cstrong\u003eKETO-00-100A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 6.74854%;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 8.86573%;\"\u003e160A\u003c\/td\u003e\n\u003ctd style=\"width: 8.86573%;\"\u003e440V DC\u003c\/td\u003e\n\u003ctd style=\"width: 9.792%;\"\u003e2 x NH00 100A Fuse-links\u003c\/td\u003e\n\u003ctd style=\"width: 10.5859%;\"\u003eM8 lugs\u003c\/td\u003e\n\u003ctd style=\"width: 8.07179%;\"\u003e25-95mm²\u003c\/td\u003e\n\u003ctd style=\"width: 12.4385%;\"\u003e106 x 195 x 84 mm\u003c\/td\u003e\n\u003ctd style=\"width: 11.1152%;\"\u003eWall mountable\u003c\/td\u003e\n\u003ctd style=\"width: 8.60108%;\"\u003e0.72 kg\u003c\/td\u003e\n\u003ctd style=\"width: 7.27784%;\"\u003eKETO-00-100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes high-quality 100A NH fuse-links for protection and easy replacement.\u003c\/li\u003e\n\u003cli\u003eCompact size 00 body for efficient panel space usage.\u003c\/li\u003e\n\u003cli\u003eThree-pole switching for enhanced safety in battery disconnection.\u003c\/li\u003e\n\u003cli\u003eRobust M8 terminal lugs supporting cables from 25mm² up to 95mm².\u003c\/li\u003e\n\u003cli\u003eWall mountable with clear isolator handle position indication.\u003c\/li\u003e\n\u003cli\u003eRated for up to 440V DC making it suitable for large battery banks and solar systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy Jean Muller KETO-00-100A?\u003c\/h3\u003e\n\u003cp\u003eDesigned for professional renewable energy and storage applications, the Jean Muller KETO-00-100A disconnector offers trusted safety and reliability to protect both your batteries and system users. The included 100A fuse-links ensure appropriate overcurrent protection, making it a cost-effective and space-saving solution for energy storage safety.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete solution with fuse-links included, reducing procurement complexity.\u003c\/li\u003e\n\u003cli\u003eTrusted Jean Muller brand quality and industry compliance.\u003c\/li\u003e\n\u003cli\u003eSimple installation and maintenance with standardized connections.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":58693532549469,"sku":"KETO-00-100A-Kit","price":38.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/jean-muller-KETO_disconnector.webp?v=1763377500"},{"product_id":"keto-battery-disconnector-with-2-x-80a-fuses","title":"Jean Muller KETO Battery Disconnector with 2 x 80A Fuses","description":"\u003cp\u003eThe Jean Muller KETO-00-80A fuse-switch-disconnector is a high-performance battery isolator ideal for DC circuit protection in solar energy storage and off-grid power systems. KETO battery disconnector featuring a compact size 00 body combined with reliable 80A NH fuse-links, this unit provides secure disconnection and protection of battery banks and inverter connections.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable style=\"border-collapse: collapse; width: 135.179%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width: 7.67481%;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"width: 6.74854%;\"\u003ePoles\u003c\/th\u003e\n\u003cth style=\"width: 8.86573%;\"\u003eRated Current\u003c\/th\u003e\n\u003cth style=\"width: 8.86573%;\"\u003eDC Voltage Rating\u003c\/th\u003e\n\u003cth style=\"width: 9.792%;\"\u003eFuse-links Included\u003c\/th\u003e\n\u003cth style=\"width: 10.5859%;\"\u003eTerminals\u003c\/th\u003e\n\u003cth style=\"width: 8.07179%;\"\u003eCable Area\u003c\/th\u003e\n\u003cth style=\"width: 12.4385%;\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003cth style=\"width: 11.1152%;\"\u003eMounting\u003c\/th\u003e\n\u003cth style=\"width: 8.60108%;\"\u003eWeight\u003c\/th\u003e\n\u003cth style=\"width: 7.27784%;\"\u003eMPN\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"width: 7.67481%;\"\u003e\u003cstrong\u003eKETO-00-80A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 6.74854%;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 8.86573%;\"\u003e160A\u003c\/td\u003e\n\u003ctd style=\"width: 8.86573%;\"\u003e440V DC\u003c\/td\u003e\n\u003ctd style=\"width: 9.792%;\"\u003e2 x NH00 80A Fuse-links\u003c\/td\u003e\n\u003ctd style=\"width: 10.5859%;\"\u003eM8 lugs\u003c\/td\u003e\n\u003ctd style=\"width: 8.07179%;\"\u003e25-95mm²\u003c\/td\u003e\n\u003ctd style=\"width: 12.4385%;\"\u003e106 x 195 x 84 mm\u003c\/td\u003e\n\u003ctd style=\"width: 11.1152%;\"\u003eWall mountable\u003c\/td\u003e\n\u003ctd style=\"width: 8.60108%;\"\u003e0.72 kg\u003c\/td\u003e\n\u003ctd style=\"width: 7.27784%;\"\u003eKETO-00-80A\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eIncludes high-quality 80A NH fuse-links compliant with IEC 60269 standards.\u003c\/li\u003e\n\u003cli\u003eCompact size 00 body ideal for space-saving panel installation.\u003c\/li\u003e\n\u003cli\u003eThree-pole design ensures safe and reliable battery disconnection.\u003c\/li\u003e\n\u003cli\u003eRobust M8 terminal lugs support cables ranging from 25mm² to 95mm².\u003c\/li\u003e\n\u003cli\u003eWall mount capable with clear open\/close visual indication.\u003c\/li\u003e\n\u003cli\u003eRated up to 440V DC suitable for large battery and solar systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Buy Jean Muller KETO-00-80A?\u003c\/h3\u003e\n\n\u003cp\u003eChosen by renewable energy professionals, the Jean Muller KETO-00-80A battery disconnector offers dependable protection and isolation for battery systems. Complete with 80A fuse-links included, it simplifies procurement and delivers trusted brand quality, ensuring safety and longevity in your DC power applications.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eComes with fuse-links included to streamline installation.\u003c\/li\u003e\n\u003cli\u003eJean Muller brand reliability trusted in industrial and renewable sectors.\u003c\/li\u003e\n\u003cli\u003eEasy installation and maintenance with standard terminal and mounting options.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":58693532615005,"sku":"KETO-00-80A-Kit","price":36.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/jean-muller-keto-fuse-switch-disconnector-size-00.webp?v=1763377500"},{"product_id":"givenergy-plug-to-plug-grommet-for-2-6-5-2-and-8-2-batteries-with-g3","title":"GivEnergy Plug to Plug + Grommet for 2.6, 5.2 and 8.2 batteries with G3","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eGivEnergy Plug to Plug + Grommet for 2.6, 5.2 and 8.2 Batteries with G3\u003c\/h2\u003e\n\u003cp\u003eThe GIV-BC-LP-G is a high-quality plug to plug cable pack designed for GivEnergy batteries with capacities of 2.6 kWh, 5.2 kWh, and 8.2 kWh featuring the G3 connection system. This cable ensures a safe, reliable, and efficient electrical connection between the battery and inverter or other system components. It includes a durable grommet to provide strain relief and protection against environmental factors. Compatible with GivEnergy's Generation 3 batteries, the cable facilitates seamless integration for smooth power transfer and optimal battery management communication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePart No: GIV-BC-LP-G\u003c\/li\u003e\n\u003cli\u003eCompatible with GivEnergy 2.6kWh, 5.2kWh, and 8.2kWh G3 batteries\u003c\/li\u003e\n\u003cli\u003ePlug to plug cable for safe electrical connections\u003c\/li\u003e\n\u003cli\u003eIncludes grommet for cable protection and strain relief\u003c\/li\u003e\n\u003cli\u003eSupports battery to inverter connection\u003c\/li\u003e\n\u003cli\u003eEnsures efficient power transfer and battery communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"seo-keywords\"\u003e\n\u003cul\u003e\n\u003cli\u003eGivEnergy plug to plug cable G3\u003c\/li\u003e\n\u003cli\u003eGIV-BC-LP-G battery cable pack\u003c\/li\u003e\n\u003cli\u003eGivEnergy 2.6kWh 5.2kWh 8.2kWh battery cable\u003c\/li\u003e\n\u003cli\u003eG3 battery inverter connection cable\u003c\/li\u003e\n\u003cli\u003eGivEnergy battery cable with grommet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"GivEnergy","offers":[{"title":"Default Title","offer_id":58693534777693,"sku":"GIV-BC-LP-G","price":79.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/GivEnergy-gen1-to-gen2-battery-cable.png?v=1762442729"},{"product_id":"givenergy-battery-cable-for-gen-2-to-gen-2","title":"GivEnergy Battery cable for Gen 2 to Gen 2","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eGivEnergy Plug to Plug for 9.5 and 5.2 Batteries with G2 Inverters (Requires Grommet)\u003c\/h2\u003e\n\u003cp\u003eThe GIV-BAT-CAB-G2-G2 is a plug-to-plug battery cable designed for connecting GivEnergy 9.5 kWh and 5.2 kWh batteries with Generation 2 (G2) inverters. This cable features an all-in-one connector at both ends, allowing quick and secure connections between compatible G2 batteries and inverters. Note that this cable requires a grommet for proper installation and protection from environmental factors. It supports both battery power and communication signals, enabling optimal system performance and seamless integration into GivEnergy energy storage solutions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePart No: GIV-BAT-CAB-G2-G2\u003c\/li\u003e\n\u003cli\u003eCompatible with GivEnergy 9.5 kWh and 5.2 kWh batteries\u003c\/li\u003e\n\u003cli\u003eDesigned for use with G2 inverters\u003c\/li\u003e\n\u003cli\u003eAll-in-one plug-to-plug connectors at both ends\u003c\/li\u003e\n\u003cli\u003eSupports power and communication signals\u003c\/li\u003e\n\u003cli\u003eRequires grommet for cable protection and strain relief\u003c\/li\u003e\n\u003cli\u003eEnables secure, efficient battery-to-inverter connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"seo-keywords\"\u003e\n\u003cul\u003e\n\u003cli\u003eGivEnergy Plug to Plug cable G2 inverter\u003c\/li\u003e\n\u003cli\u003eGIV-BAT-CAB-G2-G2 battery cable\u003c\/li\u003e\n\u003cli\u003e9.5 kWh 5.2 kWh battery cabling G2 inverter\u003c\/li\u003e\n\u003cli\u003ebattery communication and power cable\u003c\/li\u003e\n\u003cli\u003eG2 inverter compatible battery cable with grommet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"GivEnergy","offers":[{"title":"Default Title","offer_id":58693534941533,"sku":"GIV-BAT-CAB-G2-G2","price":88.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/GivEnergy-gen2-to-gen2-cable.png?v=1762442914"},{"product_id":"givenergy-plug-to-plug-grommet-for-9-5-batteries-with-g3","title":"GivEnergy plug to plug cable + Grommet for 5.12 and 9.5 batteries with G3","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eGivEnergy Plug to Plug + Grommet for 9.5 and 5.12 Batteries with G3\u003c\/h2\u003e\n\u003cp\u003eThe GIV-BC-PP-G is a premium plug to plug cable designed for seamless connection between GivEnergy 9.5 kWh and 5.12 kWh Generation 3 (G3) batteries. This cable facilitates both power and communication transmission, ensuring optimal battery management and system performance. It includes a protective grommet for strain relief and environmental protection. Ideal for connecting multiple G3 batteries or integrating with compatible G3 inverters, this cable supports flexible, safe, and efficient installation in residential and commercial energy storage setups.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePart No: GIV-BC-PP-G\u003c\/li\u003e\n\u003cli\u003eCompatible with GivEnergy 9.5 kWh and 5.12 kWh G3 batteries\u003c\/li\u003e\n\u003cli\u003ePlug-to-plug connection for quick and secure installation\u003c\/li\u003e\n\u003cli\u003eIncludes grommet for cable protection and strain relief\u003c\/li\u003e\n\u003cli\u003eSupports power and communication signals\u003c\/li\u003e\n\u003cli\u003eEnables modular system scalability and reliable battery management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"seo-keywords\"\u003e\u003cul\u003e\n\u003cli\u003eGivEnergy G3 battery plug to plug cable\u003c\/li\u003e\n\u003cli\u003eGIV-BC-PP-G battery cable with grommet\u003c\/li\u003e\n\u003cli\u003e9.5 kWh 5.12 kWh GivEnergy battery cable\u003c\/li\u003e\n\u003cli\u003eplug to plug cable G3 battery connection\u003c\/li\u003e\n\u003cli\u003eGivEnergy modular battery cable system\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e","brand":"GivEnergy","offers":[{"title":"Default Title","offer_id":58693534974301,"sku":"GIV-BC-PP-G","price":79.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/GivEnergy-gen2-to-gen2-cable.png?v=1762442914"},{"product_id":"dektite-lead-multi-cable-solar-flashing-tiled-or-slate","title":"Dektite Lead Multi Cable Solar Flashing (Tiled or Slate)","description":"\u003ch2\u003eDektite Lead Multicable Solar Flashing (Tiled or Slate)\u003c\/h2\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigned for Tile and Slate Roofs:\u003c\/strong\u003e Features an acrylic-coated lead base that provides excellent weatherproofing and durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Cable Capacity:\u003c\/strong\u003e Can accommodate up to 10 cables, reducing the need for multiple roof penetrations and simplifying installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Made with a black EPDM rubber cone with high UV resistance, resistant to extreme weather conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Roof Pitch Compatibility:\u003c\/strong\u003e Suitable for roof pitches from 0° to 45°.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Quick to fit with no ongoing maintenance required, trusted by professional installers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Backed by a 20-year manufacturer warranty for long-lasting reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy This Solar Flashing?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDektite Lead Multicable Solar Flashing\u003c\/strong\u003e offers a robust and weatherproof solution for routing multiple solar cables through tiled or slate roofs. Its lead base conforms easily to roof shapes, ensuring a watertight seal, while the EPDM cone is flexible yet tough, protecting cables from weather damage. This flashing reduces installation time, improves roof aesthetics by consolidating cables, and ensures long-term protection for both roof and cables.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDNLS10MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcrylic-coated lead base with black EPDM rubber cone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 10 cables (4-8mm diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoof Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTile and slate roofs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoof Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0° to 45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e490mm x 410mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-50°C to 115°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Deks","offers":[{"title":"Default Title","offer_id":58693535760733,"sku":"DNLS10MB","price":47.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/dektite-nulead-multicable-solar-flashing-black-epdm-1500x1500-opaque.jpg?v=1759422826"},{"product_id":"dektite-aluminium-multicable-solar-flashing-metal-roof","title":"Dektite Aluminium Multicable Solar Flashing (Metal Roof)","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigned for Metal Roofs:\u003c\/strong\u003e Specifically fits trapezoidal or corrugated metal roof profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Cable Capacity:\u003c\/strong\u003e Accommodates up to 12 solar cables, reducing the need for multiple roof penetrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Made from tough, UV-resistant EPDM rubber with a flexible aluminium base band for excellent weatherproofing and longevity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Roof Pitch Compatibility:\u003c\/strong\u003e Suitable for roof pitches from 0° to 45°.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy to Fit and Maintain:\u003c\/strong\u003e Installer-friendly design requiring no ongoing maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustry Standard:\u003c\/strong\u003e Purpose-made, compliant with MCS requirements for professional PV installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Backed by a 20-year warranty for long-term assurance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy This Solar Flashing?\u003c\/h3\u003e\n\u003cp\u003eThis \u003cstrong\u003eDektite Aluminium Multicable Solar Flashing\u003c\/strong\u003e provides a reliable, weatherproof seal for solar cables passing through metal roofs, preventing water ingress and damage to cables. Its aluminium edging enhances mechanical strength, while the EPDM rubber ensures UV resistance and flexibility. Ideal for commercial and residential photovoltaic installations, it simplifies installation by accommodating multiple cables through a single roof penetration, saving time and improving system aesthetics.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDFE101BM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUV-resistant EPDM rubber with flexible aluminium band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 12 cables (4-8mm diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoof Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrapezoidal and corrugated metal roofs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoof Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0° to 45°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e139mm x 139mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Deks","offers":[{"title":"Default Title","offer_id":58693535793501,"sku":"DFE101BM","price":21.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/DFE101BMDektiteAluminiumMulticableSolarFlashing.webp?v=1763457072"},{"product_id":"cable-pack-for-fox-lv5200-battery","title":"Cable Pack for Fox LV5200 Battery","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eCable Pack for Fox LV5200 Battery\u003c\/h2\u003e\n\u003cp\u003eThe FE-CABLE is an essential cable pack designed specifically for the Fox LV5200 battery, enabling seamless and reliable electrical connections within your energy storage setup. This cable pack ensures compatibility and optimal performance with the Fox LV5200 low-voltage lithium battery system, which features a nominal capacity of 5.12 kWh, a nominal voltage of 51.2 V, and advanced CAN\/RS485 communication capabilities. The cable pack supports safe, efficient power transfer and easy integration with Fox ESS battery modules, designed for long cycle life and stable operation across varying temperature ranges.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePart No: FE-CABLE\u003c\/li\u003e\n\u003cli\u003eDesigned for Fox LV5200 battery\u003c\/li\u003e\n\u003cli\u003eSupports low-voltage LiFePO4 system\u003c\/li\u003e\n\u003cli\u003eEnables CAN\/RS485 communication\u003c\/li\u003e\n\u003cli\u003eEnsures safe and reliable power connections\u003c\/li\u003e\n\u003cli\u003eCompatible with Fox ESS battery modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"seo-keywords\"\u003e\n\u003cul\u003e\n\u003cli\u003eFox LV5200 battery cable pack\u003c\/li\u003e\n\u003cli\u003eFE-CABLE Fox ESS connection cable\u003c\/li\u003e\n\u003cli\u003elow-voltage lithium battery cables\u003c\/li\u003e\n\u003cli\u003eFox ESS LV5200 compatible cable\u003c\/li\u003e\n\u003cli\u003ecable kit for Fox LV5200 batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Fox ESS","offers":[{"title":"Default Title","offer_id":58693536022877,"sku":"FE-CABLE","price":69.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/LV5200-Cable-Pack.webp?v=1763456669"},{"product_id":"imo-stag-ac-isolators","title":"IMO Stag IS4P AC Isolator 4-Pole 20A 32A 40A 63A 100A 125A IP65 EN60947-3 UKCA Solar PV Inverter AC Switch Disconnector Lockable Padlockable Made in UK MCS Compliant","description":"\u003cdiv style=\"font-size:16px;font-family:'Segoe UI',Helvetica,Arial,sans-serif;color:#222;background:transparent;max-width:900px;line-height:1.5;\"\u003e\n\u003cp style=\"font-size:16px;line-height:1.75;color:#333;margin:0 0 18px;\"\u003eThe \u003cstrong\u003eIMO Stag IS4P AC Isolator\u003c\/strong\u003e is the \u003cstrong\u003estandard AC switch-isolator for UK solar PV and inverter installations\u003c\/strong\u003e, available in ratings from \u003cstrong\u003e20 A to 125 A\u003c\/strong\u003e to suit domestic, commercial and industrial applications. Manufactured in the United Kingdom by Stag Electrical — one of the most widely recognised names in the UK wholesale electrical market — these isolators are \u003cstrong\u003eEN 60947-3 and IEC 60947-3 compliant\u003c\/strong\u003e, carrying full \u003cstrong\u003eUKCA, CE and SEMKO approvals\u003c\/strong\u003e. The IP65-rated polycarbonate enclosure is \u003cstrong\u003edust-tight and water-jet resistant\u003c\/strong\u003e, making it suitable for outdoor meter cupboards, consumer unit enclosures and any installation where moisture or dust exposure is a concern. The \u003cstrong\u003einterlocked lid prevents the enclosure from being opened while the isolator is in the ON position\u003c\/strong\u003e, and the \u003cstrong\u003elockable red\/yellow rotary handle\u003c\/strong\u003e can be padlocked in the OFF position — essential for safe isolation during inverter or battery maintenance. The 4th pole is an \u003cstrong\u003eEarly Make Late Break\u003c\/strong\u003e configuration, suitable for switching a neutral conductor. Multiple cable gland knockout holes (M20\/M25 on smaller sizes; M20\/M25\/M32 on larger) provide flexibility for any installation geometry.\u003c\/p\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(110px,1fr));gap:10px;margin-bottom:24px;\"\u003e\n\u003cdiv style=\"background:#008377;color:#fff;border-radius:8px;padding:14px 12px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.1;\"\u003e20–\n125A\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.85;margin-top:5px;\"\u003eRating range\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#005c54;color:#fff;border-radius:8px;padding:14px 12px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.1;\"\u003e4-pole\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.85;margin-top:5px;\"\u003eEMLB 4th pole\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377;color:#fff;border-radius:8px;padding:14px 12px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.1;\"\u003eIP65\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.85;margin-top:5px;\"\u003eEnclosure rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#005c54;color:#fff;border-radius:8px;padding:14px 12px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.1;\"\u003eUKCA\nCE\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.85;margin-top:5px;\"\u003eApprovals\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377;color:#fff;border-radius:8px;padding:14px 12px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.1;\"\u003eEN\n60947-3\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.85;margin-top:5px;\"\u003eStandard\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#005c54;color:#fff;border-radius:8px;padding:14px 12px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.1;\"\u003eMade\nin UK\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.85;margin-top:5px;\"\u003eCountry of origin\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fef2f2;border-left:4px solid #dc2626;border-radius:0 8px 8px 0;padding:14px 18px;margin:6px 0 16px;font-size:15px;color:#7f1d1d;\"\u003e\n\u003cstrong\u003e⚠ Competent person installation required:\u003c\/strong\u003e AC isolators are connected directly to the live AC output of the solar inverter or to the grid supply. Installation must be performed by a \u003cstrong\u003ecompetent electrician in accordance with BS 7671 (IET Wiring Regulations)\u003c\/strong\u003e and applicable building regulations.\u003c\/div\u003e\n\u003cdiv style=\"background:#e6f4f3;border-left:4px solid #008377;border-radius:0 8px 8px 0;padding:14px 18px;margin:6px 0 16px;font-size:15px;color:#005c54;\"\u003e\n\u003cstrong\u003eℹ MCS requirement — AC isolator mandatory for UK solar PV installations:\u003c\/strong\u003e MCS-accredited solar PV installations require an accessible AC isolator between the inverter and the grid connection point. The Stag IS4P range is suitable for this application. The lockable handle allows the isolator to be locked in the OFF position for emergency isolation and during maintenance, as required by the MCS MIS 3002 installation standard.\u003c\/div\u003e\n\u003cdiv style=\"font-size:16px;font-weight:700;color:#005c54;border-bottom:3px solid #008377;padding-bottom:8px;margin:28px 0 14px;text-transform:uppercase;letter-spacing:.05em;\"\u003eSelect the Correct Rating — Full Variant Table\u003c\/div\u003e\n\u003cp style=\"font-size:15px;color:#444;margin:0 0 12px;\"\u003eThe AC isolator must be rated at or above the maximum output current of the inverter it protects. Use the table below to select the correct IS4P variant. The 20 A or 32 A isolator covers the vast majority of domestic solar PV installations.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;margin-bottom:20px;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctr style=\"background:#008377;color:#fff;\"\u003e\n\u003cth style=\"padding:9px 12px;text-align:left;font-size:13px;font-weight:700;\"\u003ePart no.\u003c\/th\u003e\n\u003cth style=\"padding:9px 12px;text-align:left;font-size:13px;font-weight:700;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding:9px 12px;text-align:left;font-size:13px;font-weight:700;\"\u003eTypical PV \/ inverter application\u003c\/th\u003e\n\u003cth style=\"padding:9px 12px;text-align:left;font-size:13px;font-weight:700;\"\u003eEnclosure (H×W×D)\u003c\/th\u003e\n\u003cth style=\"padding:9px 12px;text-align:left;font-size:13px;font-weight:700;\"\u003eMax cable\u003c\/th\u003e\n\u003cth style=\"padding:9px 12px;text-align:left;font-size:13px;font-weight:700;\"\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;font-weight:700;color:#005c54;\"\u003eIS4P20\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003e20 A\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003eSingle-phase inverter up to 4.6 kW (20 A output)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003e125×100×85 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003e10 mm²\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;font-weight:700;color:#005c54;\"\u003eIS4P32\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003e32 A\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003eSingle-phase inverter up to 7.3 kW; 3-phase up to 11 kW motor\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003e125×100×85 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003e10 mm²\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;font-weight:700;color:#005c54;\"\u003eIS4P40\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003e40 A\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003e3-phase inverter up to 15 kW; larger AC coupled systems\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003e175×115×100 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003e10 mm²\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003e0.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;font-weight:700;color:#005c54;\"\u003eIS4P63\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003e63 A\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003e3-phase inverter up to 22 kW; commercial PV\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003e175×115×100 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003e16 mm²\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003e0.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;font-weight:700;color:#005c54;\"\u003eIS4P100\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003e100 A\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003eLarge commercial 3-phase inverter up to 37 kW\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003e240×160×120 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003e35 mm²\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#f0f9f8;border-bottom:1px solid #e0e0e0;\"\u003e1.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;font-weight:700;color:#005c54;\"\u003eIS4P125\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003e125 A\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003eLarge commercial 3-phase inverter up to 45 kW\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003e240×160×120 mm\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003e35 mm²\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;font-size:13px;background:#fff;border-bottom:1px solid #e0e0e0;\"\u003e1.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:13px;color:#666;margin:-12px 0 20px;\"\u003eAll variants are 4-pole, 230 – 440 V AC, IP65, EN 60947-3. IS4P20L and IS4P32L are larger-enclosure variants of the 20 A and 32 A models (175×115×100 mm), available for installations requiring larger cable management space. Inverter output current = rated power (W) ÷ voltage (V). For a 3.68 kW single-phase inverter: 3,680 W ÷ 230 V = 16 A → use IS4P20. Always round up to the next standard rating.\u003c\/p\u003e\n\u003cdiv style=\"font-size:16px;font-weight:700;color:#005c54;border-bottom:3px solid #008377;padding-bottom:8px;margin:28px 0 14px;text-transform:uppercase;letter-spacing:.05em;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display:flex;gap:14px;align-items:flex-start;padding:14px 16px;background:#e6f4f3;border-left:4px solid #008377;border-radius:0 6px 6px 0;margin-bottom:8px;\"\u003e\n\u003cdiv style=\"flex-shrink:0;width:28px;height:28px;background:#008377;border-radius:50%;display:flex;align-items:center;justify-content:center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1;\"\u003e\n\u003cdiv style=\"font-size:15px;font-weight:700;color:#005c54;margin-bottom:4px;\"\u003eEN 60947-3 \/ IEC 60947-3 Compliant — UKCA, CE, SEMKO Approved\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;color:#444;line-height:1.6;\"\u003eThe IS4P range is type-tested and approved to \u003cstrong\u003eEN 60947-3\u003c\/strong\u003e, the European standard for switch-disconnectors and fuse-combination units. This is the standard cited by MCS MIS 3002 and BS 7671 for safe isolation of AC circuits in solar PV installations. Approvals include \u003cstrong\u003eUKCA\u003c\/strong\u003e (UK Conformity Assessed, required post-Brexit for placing products on the UK market), \u003cstrong\u003eCE\u003c\/strong\u003e (European market), and \u003cstrong\u003eSEMKO\u003c\/strong\u003e (Scandinavian mark). RoHS compliant. Rated insulation voltage Ui: 690 V, providing substantial headroom above the 415 V operating voltage.\u003c\/div\u003e\n\u003cdiv style=\"margin-top:8px;\"\u003e\n\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eEN 60947-3 \/ IEC 60947-3\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eUKCA\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eCE\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eSEMKO\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eRoHS\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;gap:14px;align-items:flex-start;padding:14px 16px;background:#f8f8f8;border-left:4px solid #008377;border-radius:0 6px 6px 0;margin-bottom:8px;\"\u003e\n\u003cdiv style=\"flex-shrink:0;width:28px;height:28px;background:#008377;border-radius:50%;display:flex;align-items:center;justify-content:center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1;\"\u003e\n\u003cdiv style=\"font-size:15px;font-weight:700;color:#005c54;margin-bottom:4px;\"\u003eIP65 Enclosure, IP20 Body — Outdoor and Meter-Cupboard Rated\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;color:#444;line-height:1.6;\"\u003eThe \u003cstrong\u003epolycarbonate enclosure is IP65\u003c\/strong\u003e: completely sealed against dust and protected against low-pressure water jets from any direction. This makes the IS4P suitable for installation in outdoor meter enclosures, external consumer unit housings, garage walls and any location where rain splash or garden hosepipe exposure is possible. The switch mechanism body itself is rated IP20. Stainless steel lid screws resist corrosion in damp external locations.\u003c\/div\u003e\n\u003cdiv style=\"margin-top:8px;\"\u003e\n\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eIP65 enclosure\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eIP20 body\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003ePolycarbonate + SS screws\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;gap:14px;align-items:flex-start;padding:14px 16px;background:#e6f4f3;border-left:4px solid #008377;border-radius:0 6px 6px 0;margin-bottom:8px;\"\u003e\n\u003cdiv style=\"flex-shrink:0;width:28px;height:28px;background:#008377;border-radius:50%;display:flex;align-items:center;justify-content:center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1;\"\u003e\n\u003cdiv style=\"font-size:15px;font-weight:700;color:#005c54;margin-bottom:4px;\"\u003eInterlocked Lid — Cannot Open in the ON Position\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;color:#444;line-height:1.6;\"\u003eA mechanical interlock prevents the enclosure lid from being opened while the rotary handle is in the ON position. This is a critical safety feature: it is not possible to inadvertently touch live terminals while the circuit is energised. The handle must be rotated to OFF before the lid will release. This interlock is required by the wiring regulations for accessible isolators in consumer-facing installations.\u003c\/div\u003e\n\u003cdiv style=\"margin-top:8px;\"\u003e\n\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eLid interlocked in ON position\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eCannot access live terminals\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;gap:14px;align-items:flex-start;padding:14px 16px;background:#f8f8f8;border-left:4px solid #008377;border-radius:0 6px 6px 0;margin-bottom:8px;\"\u003e\n\u003cdiv style=\"flex-shrink:0;width:28px;height:28px;background:#008377;border-radius:50%;display:flex;align-items:center;justify-content:center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1;\"\u003e\n\u003cdiv style=\"font-size:15px;font-weight:700;color:#005c54;margin-bottom:4px;\"\u003eLockable Red\/Yellow Rotary Handle — Padlockable in OFF\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;color:#444;line-height:1.6;\"\u003eThe distinctive \u003cstrong\u003ered and yellow rotary handle\u003c\/strong\u003e follows the BS 7671 colour convention for isolation devices. A padlock can be fitted through the handle when it is in the OFF position, preventing the circuit from being re-energised during maintenance. This is an MCS installation requirement for solar PV AC isolators: the firefighter or emergency service must be able to lock off the supply before approaching the roof or inverter. The lockable handle also serves for energy company meter testing isolation and general contractor lock-off\/tag-out procedures.\u003c\/div\u003e\n\u003cdiv style=\"margin-top:8px;\"\u003e\n\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eRed\/yellow handle\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003ePadlockable in OFF\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eMCS compliant\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;gap:14px;align-items:flex-start;padding:14px 16px;background:#e6f4f3;border-left:4px solid #008377;border-radius:0 6px 6px 0;margin-bottom:8px;\"\u003e\n\u003cdiv style=\"flex-shrink:0;width:28px;height:28px;background:#008377;border-radius:50%;display:flex;align-items:center;justify-content:center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1;\"\u003e\n\u003cdiv style=\"font-size:15px;font-weight:700;color:#005c54;margin-bottom:4px;\"\u003e4th Pole — Early Make Late Break for Neutral Switching\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;color:#444;line-height:1.6;\"\u003eAll IS4P variants are \u003cstrong\u003e4-pole\u003c\/strong\u003e. Three poles switch the line conductors (L1, L2, L3 in three-phase; L1 plus two additional poles in single-phase use). The \u003cstrong\u003e4th pole is configured as Early Make Late Break (EMLB)\u003c\/strong\u003e for neutral switching: when closing the isolator, the neutral connects before the live poles; when opening, the neutral disconnects after the live poles. This sequence ensures the neutral is always in place before current flows, preventing overvoltages from neutral loss. The 4th pole can also be used to switch a neutral in a 3-phase+N system.\u003c\/div\u003e\n\u003cdiv style=\"margin-top:8px;\"\u003e\n\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003e4-pole\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003e4th pole: Early Make Late Break\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eNeutral switching\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;gap:14px;align-items:flex-start;padding:14px 16px;background:#f8f8f8;border-left:4px solid #008377;border-radius:0 6px 6px 0;margin-bottom:8px;\"\u003e\n\u003cdiv style=\"flex-shrink:0;width:28px;height:28px;background:#008377;border-radius:50%;display:flex;align-items:center;justify-content:center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1;\"\u003e\n\u003cdiv style=\"font-size:15px;font-weight:700;color:#005c54;margin-bottom:4px;\"\u003eMultiple Gland Knockouts — Flexible Cable Entry\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;color:#444;line-height:1.6;\"\u003eThe enclosure features \u003cstrong\u003emultiple pre-formed gland knockout holes\u003c\/strong\u003e on the base, top and sides. Sizes: M20 and M25 on the 20A, 32A, 40A and 63A enclosures; M20, M25 and M32 on the 100A, 125A and 150A enclosures. These accept standard IP65 cable glands, allowing the installer to choose cable entry positions to suit the specific installation geometry and maintain the enclosure’s IP65 rating (unused knockouts should be plugged with appropriate blanking glands).\u003c\/div\u003e\n\u003cdiv style=\"margin-top:8px;\"\u003e\n\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eM20\/M25 knockouts (20– 63A)\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eM20\/M25\/M32 knockouts (100– 125A)\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eTop, base and side entry\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;gap:14px;align-items:flex-start;padding:14px 16px;background:#e6f4f3;border-left:4px solid #008377;border-radius:0 6px 6px 0;margin-bottom:8px;\"\u003e\n\u003cdiv style=\"flex-shrink:0;width:28px;height:28px;background:#008377;border-radius:50%;display:flex;align-items:center;justify-content:center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1;\"\u003e\n\u003cdiv style=\"font-size:15px;font-weight:700;color:#005c54;margin-bottom:4px;\"\u003eFlame-Retardant Polycarbonate — UK Manufactured\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;color:#444;line-height:1.6;\"\u003eThe IS4P enclosure is moulded from \u003cstrong\u003eflame-retardant polycarbonate\u003c\/strong\u003e, a material with excellent electrical insulation properties, impact resistance and UV stability for external use. In the event of an internal fault, the enclosure is self-extinguishing and does not propagate flame to adjacent materials. \u003cstrong\u003eMade in the United Kingdom\u003c\/strong\u003e by Stag Electrical, the IS4P range is a staple of the UK wholesale electrical and solar trade and has been specified by UK installers for decades.\u003c\/div\u003e\n\u003cdiv style=\"margin-top:8px;\"\u003e\n\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eFlame-retardant polycarbonate\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eUV stable\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eMade in UK\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;gap:14px;align-items:flex-start;padding:14px 16px;background:#f8f8f8;border-left:4px solid #008377;border-radius:0 6px 6px 0;margin-bottom:8px;\"\u003e\n\u003cdiv style=\"flex-shrink:0;width:28px;height:28px;background:#008377;border-radius:50%;display:flex;align-items:center;justify-content:center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex:1;\"\u003e\n\u003cdiv style=\"font-size:15px;font-weight:700;color:#005c54;margin-bottom:4px;\"\u003eOptional Auxiliary Contacts (SAC) — Remote Status Monitoring\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;color:#444;line-height:1.6;\"\u003eOptional \u003cstrong\u003eSAC auxiliary contact modules\u003c\/strong\u003e are available for the IS4P range, fitting onto the left-hand side of the isolator body. Each SAC provides \u003cstrong\u003e1 normally open (NO) and 1 normally closed (NC) contact\u003c\/strong\u003e (rated 6 A at 230 V AC15; 1.1 A at 125 V DC13). These allow the isolator’s switch position to be signalled remotely to a monitoring system, inverter, or energy management controller. Three SAC variants cover the full IS4P range: SAC32-11 (for 20A\/32A), SAC63-11 (for 40A\/63A), SAC150-11 (for 80A–150A).\u003c\/div\u003e\n\u003cdiv style=\"margin-top:8px;\"\u003e\n\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003e1NO + 1NC auxiliary\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eSAC32-11 \/ SAC63-11 \/ SAC150-11\u003c\/span\u003e\u003cspan style=\"display:inline-block;background:#008377;color:#fff;border-radius:20px;padding:3px 11px;font-size:13px;font-weight:700;letter-spacing:.02em;margin:2px 4px 2px 0;white-space:nowrap;\"\u003eRemote status signalling\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:16px;font-weight:700;color:#005c54;border-bottom:3px solid #008377;padding-bottom:8px;margin:28px 0 14px;text-transform:uppercase;letter-spacing:.05em;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003cdiv style=\"overflow-x:auto;margin-bottom:24px;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377;color:#fff;font-weight:700;padding:9px 14px;font-size:13px;letter-spacing:.06em;text-transform:uppercase;\"\u003eAll IS4P Variants — Common Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003e4 (L1, L2, L3 + Early Make Late Break neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eRated voltage (AC21)\u003c\/td\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003e230 – 440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eRated insulation voltage Ui\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eProtection class (enclosure)\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eProtection class (body)\u003c\/td\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eEnclosure material\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003ePolycarbonate, flame-retardant, UV stabilised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eLid screws\u003c\/td\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eLid interlock\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003ePrevents opening in ON position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eHandle\u003c\/td\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eLockable red\/yellow rotary (padlockable in OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eMechanical life\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003e10,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eRated cond. short circuit current\u003c\/td\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003e20 × Ie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eShort time withstand (1 s)\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003e12 × Ie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eRated make\/break capacity\u003c\/td\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003e8 × Ie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eGland knockouts\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eM20\/M25 (20 A – 63 A) · M20\/M25\/M32 (80 A – 150 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377;color:#fff;font-weight:700;padding:9px 14px;font-size:13px;letter-spacing:.06em;text-transform:uppercase;\"\u003eStandards and Approvals\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eProduct standard\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eEN 60947-3 \/ IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eApprovals\u003c\/td\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eUKCA, CE, SEMKO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eEnvironmental\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eRoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eCountry of manufacture\u003c\/td\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eUnited Kingdom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377;color:#fff;font-weight:700;padding:9px 14px;font-size:13px;letter-spacing:.06em;text-transform:uppercase;\"\u003eVariant Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eIS4P20 (20A)\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eDims: 125×100×85 mm · Cable: 10 mm² · Torque: 2 N m · Weight: 0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eIS4P32 (32A)\u003c\/td\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eDims: 125×100×85 mm · Cable: 10 mm² · Torque: 2 N m · Weight: 0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eIS4P40 (40A)\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eDims: 175×115×100 mm · Cable: 10 mm² · Torque: 2 N m · Weight: 0.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eIS4P63 (63A)\u003c\/td\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eDims: 175×115×100 mm · Cable: 16 mm² · Torque: 2 N m · Weight: 0.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eIS4P100 (100A)\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eDims: 240×160×120 mm · Cable: 35 mm² · Torque: 3 N m · Weight: 1.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eIS4P125 (125A)\u003c\/td\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eDims: 240×160×120 mm · Cable: 35 mm² · Torque: 3 N m · Weight: 1.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377;color:#fff;font-weight:700;padding:9px 14px;font-size:13px;letter-spacing:.06em;text-transform:uppercase;\"\u003eOptional Accessories\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eAuxiliary contacts (20A \/ 32A)\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eSAC32-11: 1NO + 1NC, 6 A @ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eAuxiliary contacts (40A \/ 63A)\u003c\/td\u003e\n\u003ctd style=\"background:#fff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eSAC63-11: 1NO + 1NC, 6 A @ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:46%;border-bottom:1px solid #e0e0e0;\"\u003eAuxiliary contacts (80A – 150A)\u003c\/td\u003e\n\u003ctd style=\"background:#f0f9f8;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e0e0e0;\"\u003eSAC150-11: 1NO + 1NC, 6 A @ 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:16px;font-weight:700;color:#005c54;border-bottom:3px solid #008377;padding-bottom:8px;margin:28px 0 14px;text-transform:uppercase;letter-spacing:.05em;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px;font-size:15px;font-weight:700;color:#005c54;cursor:pointer;list-style:none;display:flex;align-items:center;justify-content:space-between;background:#f5fbfa;\"\u003e\u003cspan\u003eWhich rating do I need for my solar inverter?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px;font-size:15px;color:#444;line-height:1.65;border-top:1px solid #cde3e1;background:#fff;\"\u003eDivide the inverter’s rated output power (in watts) by the circuit voltage to get the output current, then select the next standard IS4P rating above that figure. Examples: a 3.68 kW single-phase inverter at 230 V outputs 16 A → use the \u003cstrong\u003eIS4P20\u003c\/strong\u003e. A 5.0 kW single-phase inverter at 230 V outputs 21.7 A → use the \u003cstrong\u003eIS4P32\u003c\/strong\u003e. A 10 kW three-phase inverter at 415 V outputs 13.9 A → use the \u003cstrong\u003eIS4P20\u003c\/strong\u003e. If in doubt, select the next size up. Never select a rating lower than the inverter’s rated maximum output current.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px;font-size:15px;font-weight:700;color:#005c54;cursor:pointer;list-style:none;display:flex;align-items:center;justify-content:space-between;background:#f5fbfa;\"\u003e\u003cspan\u003eIs this isolator required for MCS-accredited solar installations?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px;font-size:15px;color:#444;line-height:1.65;border-top:1px solid #cde3e1;background:#fff;\"\u003eYes. MCS MIS 3002 requires an accessible AC isolator between the inverter and the grid connection point. The isolator must be lockable in the OFF position so that the supply can be isolated and locked off for emergency services or during maintenance. The Stag IS4P meets this requirement: it is lockable, accessible, EN 60947-3 compliant, and carries UKCA approval for the UK market.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px;font-size:15px;font-weight:700;color:#005c54;cursor:pointer;list-style:none;display:flex;align-items:center;justify-content:space-between;background:#f5fbfa;\"\u003e\u003cspan\u003eWhat is the Early Make Late Break 4th pole, and do I need to use it?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px;font-size:15px;color:#444;line-height:1.65;border-top:1px solid #cde3e1;background:#fff;\"\u003eEMLB (Early Make Late Break) describes the switching sequence of the 4th pole relative to the other three poles. When the isolator is turned ON, the 4th pole connects \u003cstrong\u003ebefore\u003c\/strong\u003e the other three poles. When turned OFF, the 4th pole disconnects \u003cstrong\u003eafter\u003c\/strong\u003e the other three. This is the correct sequence for a neutral conductor. In a standard UK single-phase PV system (230 V AC), you have L + N. Connect L to one of the numbered poles and N to the EMLB pole. The other two numbered poles remain unused (or are wired as part of a multi-pole scheme). In a three-phase system, use L1, L2, L3 on the three numbered poles and N on the EMLB 4th pole.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px;font-size:15px;font-weight:700;color:#005c54;cursor:pointer;list-style:none;display:flex;align-items:center;justify-content:space-between;background:#f5fbfa;\"\u003e\u003cspan\u003eCan this isolator be mounted outdoors?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px;font-size:15px;color:#444;line-height:1.65;border-top:1px solid #cde3e1;background:#fff;\"\u003eYes, the IP65 enclosure is rated for outdoor surface mounting. IP65 means the enclosure is fully dust-tight and protected against low-pressure water jets from any direction (e.g. rain, garden hose spray). It is not rated for submersion (IP67\/68), so do not install where it may flood. The polycarbonate material is UV stabilised for long-term outdoor use. Stainless steel lid screws prevent corrosion. Ensure all unused gland knockouts are fitted with appropriate IP65-rated blanking glands to maintain the enclosure’s ingress protection.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px;font-size:15px;font-weight:700;color:#005c54;cursor:pointer;list-style:none;display:flex;align-items:center;justify-content:space-between;background:#f5fbfa;\"\u003e\u003cspan\u003eWhat is the difference between IS4P20 and IS4P20L (the ‘L’ variant)?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px;font-size:15px;color:#444;line-height:1.65;border-top:1px solid #cde3e1;background:#fff;\"\u003eThe ‘L’ suffix denotes a \u003cstrong\u003elarger enclosure\u003c\/strong\u003e. The IS4P20L uses the same 20 A switch mechanism as the IS4P20 but is housed in the larger 175×115×100 mm enclosure (the same body used for the 40 A and 63 A models). This gives more room inside the enclosure for cable management, particularly useful when the installer needs to bring larger cables to the isolator or where there are multiple cables entering the same enclosure. Weight increases from 0.52 kg to 0.75 kg. Electrically identical to the IS4P20.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px;font-size:15px;font-weight:700;color:#005c54;cursor:pointer;list-style:none;display:flex;align-items:center;justify-content:space-between;background:#f5fbfa;\"\u003e\u003cspan\u003eCan I fit auxiliary contacts for remote monitoring?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px;font-size:15px;color:#444;line-height:1.65;border-top:1px solid #cde3e1;background:#fff;\"\u003eYes. Optional \u003cstrong\u003eSAC auxiliary contact modules\u003c\/strong\u003e clip onto the left-hand side of the isolator body. Select the correct SAC for your isolator: SAC32-11 for IS4P20 and IS4P32; SAC63-11 for IS4P40 and IS4P63; SAC150-11 for IS4P80 through IS4P150. Each SAC provides one normally open (NO) and one normally closed (NC) contact rated at 6 A at 230 V AC. These can be wired to an inverter’s external signal input, a building management system, or a remote alarm panel to indicate whether the isolator is open or closed.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:16px;font-weight:700;color:#005c54;border-bottom:3px solid #008377;padding-bottom:8px;margin:28px 0 14px;text-transform:uppercase;letter-spacing:.05em;\"\u003eRelated Products\u003c\/div\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(210px,1fr));gap:10px;margin-bottom:10px;\"\u003e\n\u003cdiv style=\"border:1px solid #cde3e1;border-radius:8px;padding:16px 18px;text-align:center;background:#f5fbfa;\"\u003e\n\u003cdiv style=\"font-size:15px;font-weight:700;color:#005c54;margin-bottom:4px;\"\u003eIMO DC Isolator — 16A 2-Pole 800V\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px;color:#666;\"\u003eSingle-string DC isolator for the PV array side of the system\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #cde3e1;border-radius:8px;padding:16px 18px;text-align:center;background:#f5fbfa;\"\u003e\n\u003cdiv style=\"font-size:15px;font-weight:700;color:#005c54;margin-bottom:4px;\"\u003eAiko 490W Neostar 3P+ Solar Panel\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px;color:#666;\"\u003eHighest-efficiency residential solar panel for new installations\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #cde3e1;border-radius:8px;padding:16px 18px;text-align:center;background:#f5fbfa;\"\u003e\n\u003cdiv style=\"font-size:15px;font-weight:700;color:#005c54;margin-bottom:4px;\"\u003eSolis S6 Hybrid Inverter (Single Phase)\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px;color:#666;\"\u003eCompatible single-phase hybrid inverter requiring a 20A or 32A AC isolator\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #cde3e1;border-radius:8px;padding:16px 18px;text-align:center;background:#f5fbfa;\"\u003e\n\u003cdiv style=\"font-size:15px;font-weight:700;color:#005c54;margin-bottom:4px;\"\u003eJean Müller KETO-1 NH Fuse-Switch Disconnector\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px;color:#666;\"\u003eBattery DC protection for low-voltage energy storage systems\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"IMO","offers":[{"title":"3 Pole 20A - Single phase","offer_id":62602534355293,"sku":"IMO-IS4P20-1P","price":17.0,"currency_code":"GBP","in_stock":true},{"title":"4 Pole 20A","offer_id":62602534388061,"sku":"IMO-IS4P20","price":17.0,"currency_code":"GBP","in_stock":true},{"title":"4 Pole 32A","offer_id":62602534420829,"sku":"IMO-IS4P32","price":19.0,"currency_code":"GBP","in_stock":true},{"title":"4 Pole 40A","offer_id":62602534486365,"sku":"IMO-IS4P40","price":25.0,"currency_code":"GBP","in_stock":true},{"title":"4 Pole 63A","offer_id":62602534519133,"sku":"IMO-IS4P63","price":30.0,"currency_code":"GBP","in_stock":true},{"title":"4 Pole 80A","offer_id":62602534551901,"sku":"IMO-IS4P80","price":50.0,"currency_code":"GBP","in_stock":true},{"title":"4 Pole 100A","offer_id":62602534584669,"sku":"IMO-IS4P100","price":55.0,"currency_code":"GBP","in_stock":true},{"title":"4 Pole 125A","offer_id":62602534617437,"sku":"IMO-IS4P125","price":89.0,"currency_code":"GBP","in_stock":true},{"title":"4 Pole 150A","offer_id":62602534650205,"sku":"IMO-IS4P150","price":99.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/IMO_AC_Isolator_IS4P20.png?v=1763368407"},{"product_id":"imo-stag-dc-isolators","title":"IMO Stag DC Isolators","description":"\u003ch2\u003eIMO Stag DC Isolators\u003c\/h2\u003e\n\u003cp\u003eThe IMO Stag DC Isolator range is engineered specifically for safe and effective isolation within solar PV DC circuits. Featuring robust IP66-rated enclosures and two- or four-pole configurations, these isolators provide high resistance to dust and water ingress for outdoor renewable energy applications.\u003c\/p\u003e\n\u003ch3\u003eAvailable DC Variants \u0026amp; Technical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eVariant (Type Number)\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003cth\u003eMax Voltage\u003c\/th\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003cth\u003eMPN\u003c\/th\u003e\n\u003cth\u003eEAN\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIMO-SI16-PEL64R-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003e800V\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003ctd\u003eDC Isolation\u003c\/td\u003e\n\u003ctd\u003eIMO-SI16-PEL64R-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIMO-SI16-PEL64R-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003e800V\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003ctd\u003eDC Isolation\u003c\/td\u003e\n\u003ctd\u003eIMO-SI16-PEL64R-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIMO-SI25-PEL64R-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003e800V\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003ctd\u003eDC Isolation\u003c\/td\u003e\n\u003ctd\u003eIMO-SI25-PEL64R-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIMO-SI25-PEL64R-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003e800V\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003ctd\u003eDC Isolation\u003c\/td\u003e\n\u003ctd\u003eIMO-SI25-PEL64R-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIMO-SI32-PEL64R-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003ctd\u003eDC Isolation\u003c\/td\u003e\n\u003ctd\u003eIMO-SI32-PEL64R-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIMO-SI32-PEL64R-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003ctd\u003eDC Isolation\u003c\/td\u003e\n\u003ctd\u003eIMO-SI32-PEL64R-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh \u003cstrong\u003eIP66\u003c\/strong\u003e ingress protection ensures durability in harsh outdoor environments.\u003c\/li\u003e\n\u003cli\u003eDesigned for solar PV DC circuit isolation with 2- and 4-pole options.\u003c\/li\u003e\n\u003cli\u003eRugged enclosures for superior water and dust resistance.\u003c\/li\u003e\n\u003cli\u003eCompact and easy to install in rooftop or ground-mount solar systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy IMO Stag DC Isolators?\u003c\/h3\u003e\n\u003cp\u003eIMO Stag DC Isolators provide professional-grade isolation solutions specifically for renewable energy systems that demand robust protection and safety. These isolators help safeguard solar PV installations with dependable switching performance and weatherproof design.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComprehensive range of current ratings for varied solar PV system sizes.\u003c\/li\u003e\n\u003cli\u003eDesigned to withstand environmental challenges and maintain operational safety.\u003c\/li\u003e\n\u003cli\u003eSimple installation with flexible pole design to suit system configurations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"IMO","offers":[{"title":"2 pole 1 string 16A 800V","offer_id":62602675913053,"sku":"IMO-SI16-PEL64R-2","price":35.0,"currency_code":"GBP","in_stock":true},{"title":"4 pole 2 string 16A 800V","offer_id":62602675945821,"sku":"IMO-SI16-PEL64R-4","price":37.0,"currency_code":"GBP","in_stock":true},{"title":"2 pole 1 string 25A 800V","offer_id":62602675978589,"sku":"IMO-SI25-PEL64R-2","price":57.0,"currency_code":"GBP","in_stock":true},{"title":"4 pole 2 string 25A 800V","offer_id":62602676109661,"sku":"IMO-SI25-PEL64R-4","price":67.0,"currency_code":"GBP","in_stock":true},{"title":"2 pole 1 string 32A 600V","offer_id":62602676142429,"sku":"IMO-SI32-PEL64R-2","price":83.0,"currency_code":"GBP","in_stock":true},{"title":"4 pole 2 string 32A 600V","offer_id":62602676175197,"sku":"IMO-SI32-PEL64R-4","price":97.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/IMO_DC_Isolator_SI16-PEL64R-2.png?v=1763370953"},{"product_id":"jean-muller-keto-size-00-fuse-switch-disconnector-battery-isolator","title":"Jean Muller KETO Size 00 Fuse Switch-Disconnector - Battery Isolator","description":"\u003cp\u003eThe Jean Muller KETO size 00 fuse switch-disconnector is a high-quality battery isolator designed for secure DC circuit protection in energy storage and solar PV applications. Renowned for robust engineering and maximum user safety, this unit ensures safe isolation of battery banks and inverter connections, helping to prevent accidental energizing during maintenance or installation.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable style=\"border-collapse: collapse; width: 135.893%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width: 7.62735%;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"width: 6.7068%;\"\u003ePoles\u003c\/th\u003e\n\u003cth style=\"width: 8.8109%;\"\u003eRated Current\u003c\/th\u003e\n\u003cth style=\"width: 8.8109%;\"\u003eDC Voltage Rating\u003c\/th\u003e\n\u003cth style=\"width: 10.389%;\"\u003eFuse-links (not included)\u003c\/th\u003e\n\u003cth style=\"width: 10.5205%;\"\u003eTerminals\u003c\/th\u003e\n\u003cth style=\"width: 8.02186%;\"\u003eCable Area\u003c\/th\u003e\n\u003cth style=\"width: 12.3616%;\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003cth style=\"width: 11.0465%;\"\u003eMounting\u003c\/th\u003e\n\u003cth style=\"width: 8.54789%;\"\u003eWeight\u003c\/th\u003e\n\u003cth style=\"width: 7.23283%;\"\u003eMPN\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"width: 7.62735%;\"\u003e\u003cstrong\u003eKETO-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 6.7068%;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 8.8109%;\"\u003e160A\u003c\/td\u003e\n\u003ctd style=\"width: 8.8109%;\"\u003e440V DC\u003c\/td\u003e\n\u003ctd style=\"width: 10.389%;\"\u003eRequires 2 x NH00 fuse-links\u003c\/td\u003e\n\u003ctd style=\"width: 10.5205%;\"\u003eM8 lugs\u003c\/td\u003e\n\u003ctd style=\"width: 8.02186%;\"\u003e25-95mm²\u003c\/td\u003e\n\u003ctd style=\"width: 12.3616%;\"\u003e106 x 195 x 84 mm\u003c\/td\u003e\n\u003ctd style=\"width: 11.0465%;\"\u003eWall mountable\u003c\/td\u003e\n\u003ctd style=\"width: 8.54789%;\"\u003e0.72 kg\u003c\/td\u003e\n\u003ctd style=\"width: 7.23283%;\"\u003eKETO-00\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eHigh rated current: \u003cstrong\u003e160A\u003c\/strong\u003e for robust battery and inverter isolation.\u003c\/li\u003e\n\u003cli\u003eLow profile, compact body for effective space management in control panels.\u003c\/li\u003e\n\u003cli\u003eThree-pole switching for added safety and flexibility.\u003c\/li\u003e\n\u003cli\u003eDurable terminals accept cables from \u003cstrong\u003e25mm² to 95mm²\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eWall mountable design for straightforward installation.\u003c\/li\u003e\n\u003cli\u003eFuse-switch-disconnector incorporates clear open\/close indication for safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Buy Jean Muller KETO-00?\u003c\/h3\u003e\n\n\u003cp\u003eThe Jean Muller KETO-00 is the professional’s choice for battery isolation, offering superior protection for DC connections in energy storage, solar PV, and off-grid power systems. Its robust construction and excellent switching performance help protect both battery assets and maintenance teams from accidental surges and short circuits.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003ePremium brand trusted by renewable industry professionals.\u003c\/li\u003e\n\u003cli\u003eVersatile connection options suit a wide range of energy storage systems.\u003c\/li\u003e\n\u003cli\u003eEasy installation and maintenance with dedicated fuse-link compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":62603096555869,"sku":"KETO-00","price":29.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/jean-muller-keto-fuse-switch-disconnector-size-00.webp?v=1763377500"},{"product_id":"jean-muller-keto-00-battery-disconnector-with-40a-fuses","title":"Jean Muller KETO-00 Battery Disconnector with 40A Fuses","description":"\u003cp\u003eThe Jean Muller KETO-00-40A fuse-switch-disconnector is designed for reliable battery isolation and DC circuit protection in solar energy storage and off-grid power systems. This compact size 00 unit includes high-quality 40A NH fuse-links, providing safe and secure disconnection for battery banks and inverter circuits.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003cth\u003eDC Voltage Rating\u003c\/th\u003e\n\u003cth\u003eFuse-links Included\u003c\/th\u003e\n\u003cth\u003eTerminals\u003c\/th\u003e\n\u003cth\u003eCable Area\u003c\/th\u003e\n\u003cth\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003cth\u003eMPN\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKETO-00-40A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e160A\u003c\/td\u003e\n\u003ctd\u003e440V DC\u003c\/td\u003e\n\u003ctd\u003e2 × NH00 40A Fuse-links\u003c\/td\u003e\n\u003ctd\u003eM8 lugs\u003c\/td\u003e\n\u003ctd\u003e25-95mm²\u003c\/td\u003e\n\u003ctd\u003e106 x 195 x 84 mm\u003c\/td\u003e\n\u003ctd\u003eWall mountable\u003c\/td\u003e\n\u003ctd\u003e0.72 kg\u003c\/td\u003e\n\u003ctd\u003eKETO-00-40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes 40A NH fuse-links compliant with IEC 60269 standards.\u003c\/li\u003e\n\u003cli\u003eCompact size 00 body ideal for space-saving electrical panels.\u003c\/li\u003e\n\u003cli\u003eThree-pole switching for secure battery and DC circuit isolation.\u003c\/li\u003e\n\u003cli\u003eRobust M8 terminal lugs support cable sizes from 25mm² to 95mm².\u003c\/li\u003e\n\u003cli\u003eWall mountable design with clear open\/closed position indication.\u003c\/li\u003e\n\u003cli\u003eRated for up to 440V DC, suitable for various renewable energy battery systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy Jean Muller KETO-00-40A?\u003c\/h3\u003e\n\u003cp\u003eThe Jean Muller KETO-00-40A battery disconnector provides trusted circuit protection and isolation for renewable energy systems. With fuse-links included, it offers a convenient, reliable solution to safeguarding battery banks and DC power circuits.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete fused disconnection solution simplifies procurement and installation.\u003c\/li\u003e\n\u003cli\u003eTrusted Jean Muller quality ensures durability and safety.\u003c\/li\u003e\n\u003cli\u003eEasy to install and maintain in renewable and off-grid power systems.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":62603099013469,"sku":"KETO-00-40A-Kit","price":38.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/jean-muller-keto-fuse-switch-disconnector-size-00.webp?v=1763377500"},{"product_id":"jean-muller-keto-00-battery-disconnector-with-125a-fuses","title":"Jean Muller KETO-00 Battery Disconnector with 125A Fuses","description":"\u003cp\u003eThe Jean Muller KETO-00-125A fuse-switch-disconnector is a robust battery isolator designed for efficient and safe DC circuit protection in solar energy storage and large battery bank applications. This unit includes reliable 125A NH fuse-links, offering high-capacity disconnection with compact size 00 construction.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003cth\u003eDC Voltage Rating\u003c\/th\u003e\n\u003cth\u003eFuse-links Included\u003c\/th\u003e\n\u003cth\u003eTerminals\u003c\/th\u003e\n\u003cth\u003eCable Area\u003c\/th\u003e\n\u003cth\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003cth\u003eMPN\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKETO-00-125A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e160A\u003c\/td\u003e\n\u003ctd\u003e440V DC\u003c\/td\u003e\n\u003ctd\u003e2 × NH00 125A Fuse-links\u003c\/td\u003e\n\u003ctd\u003eM8 lugs\u003c\/td\u003e\n\u003ctd\u003e25-95mm²\u003c\/td\u003e\n\u003ctd\u003e106 x 195 x 84 mm\u003c\/td\u003e\n\u003ctd\u003eWall mountable\u003c\/td\u003e\n\u003ctd\u003e0.72 kg\u003c\/td\u003e\n\u003ctd\u003eKETO-00-125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes high-quality 125A NH fuse-links for enhanced circuit protection.\u003c\/li\u003e\n\u003cli\u003eCompact and robust size 00 body for easy panel integration.\u003c\/li\u003e\n\u003cli\u003eThree-pole switch for effective battery isolation and safe operation.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty M8 terminal lugs accommodate cables from 25mm² to 95mm².\u003c\/li\u003e\n\u003cli\u003eWall mountable with clear switch position indication.\u003c\/li\u003e\n\u003cli\u003eRated up to 440V DC, suitable for larger battery banks and solar systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy Jean Muller KETO-00-125A?\u003c\/h3\u003e\n\u003cp\u003eThe Jean Muller KETO-00-125A battery disconnector is the ideal solution for professionals requiring high-capacity fused disconnection in renewable power and storage applications. With included fuse-links and trusted Jean Muller quality, it delivers both safety and reliability with installation convenience.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete fused disconnector solution with included NH fuse-links.\u003c\/li\u003e\n\u003cli\u003eRenowned Jean Muller engineering ensuring long-term durability.\u003c\/li\u003e\n\u003cli\u003eSimple and safe installation in DC power distribution systems.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":62603106222429,"sku":"KETO-00-125A-Kit","price":40.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/jean-muller-keto-fuse-switch-disconnector-size-00.webp?v=1763377500"},{"product_id":"jean-muller-keto-1-fuse-switch-disconnector-size-1-body-battery-isolator","title":"Jean Muller KETO-1 Fuse-Switch-Disconnector Size 1 Body - Battery Isolator","description":"\u003cp\u003eThe Jean Muller KETO-1 fuse-switch-disconnector is a robust and versatile battery isolator designed for high-capacity DC applications. Built for energy storage and solar power systems, this unit ensures safe and reliable disconnection of large battery and inverter circuits, with a maximum DC current rating of 250A.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003cth\u003eDC Voltage Rating\u003c\/th\u003e\n\u003cth\u003eFuse-links Included\u003c\/th\u003e\n\u003cth\u003eTerminals\u003c\/th\u003e\n\u003cth\u003eCable Area\u003c\/th\u003e\n\u003cth\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003cth\u003eSystem Size\u003c\/th\u003e\n\u003cth\u003eMPN\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKETO-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003ctd\u003e690V DC\u003c\/td\u003e\n\u003ctd\u003e2 x NH00 250A Fuse-links\u003c\/td\u003e\n\u003ctd\u003eM10 lugs\u003c\/td\u003e\n\u003ctd\u003e25-150mm²\u003c\/td\u003e\n\u003ctd\u003e184 x 300 mm\u003c\/td\u003e\n\u003ctd\u003eDIN rail or panel mount\u003c\/td\u003e\n\u003ctd\u003eUp to 300mm system length\u003c\/td\u003e\n\u003ctd\u003eKETO-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum DC Current:\u003c\/strong\u003e 250A – suited for large solar and energy storage systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Voltage Rating:\u003c\/strong\u003e 690V – suitable for high-voltage DC applications.\u003c\/li\u003e\n\u003cli\u003eRated for DIN rail or panel mounting for flexible installation.\u003c\/li\u003e\n\u003cli\u003eIncludes high-quality NH fuse links for reliable circuit protection.\u003c\/li\u003e\n\u003cli\u003eDurable construction with robust M10 terminal lugs supporting cable sizes from 25mm² to 150mm².\u003c\/li\u003e\n\u003cli\u003eSophisticated design allows safe and efficient system disconnection and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose Jean Muller KETO-1?\u003c\/h3\u003e\n\u003cp\u003eThe Jean Muller KETO-1 fuse-disconnector provides a trustworthy and high-performance solution for high-current DC systems. Known for safety, longevity, and ease of installation, it is the ideal choice for professional solar, storage, and renewable energy projects requiring robust circuit protection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-current capacity boosting system reliability.\u003c\/li\u003e\n\u003cli\u003eFlexible mounting options for various system configurations.\u003c\/li\u003e\n\u003cli\u003eIndustry-standard safety features and proven durability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":62603132797277,"sku":"KETO-1","price":83.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/JeanMullerKETO1BatteryDisconnectorwith160AFuses.webp?v=1763378746"},{"product_id":"jean-muller-keto-1-battery-disconnector-with-160a-fuses","title":"Jean Muller KETO-1 Battery Disconnector with 160A Fuses","description":"\u003cp\u003eThe Jean Muller KETO-1-160A fuse-switch-disconnector is designed for high-capacity DC circuit protection in energy storage and solar PV systems. This unit includes a size 1 body battery isolator equipped with reliable 160A NH fuse-links, offering robust safety and efficient disconnection of large battery banks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003cth\u003eDC Voltage Rating\u003c\/th\u003e\n\u003cth\u003eFuse-links Included\u003c\/th\u003e\n\u003cth\u003eTerminals\u003c\/th\u003e\n\u003cth\u003eCable Area\u003c\/th\u003e\n\u003cth\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003cth\u003eMPN\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKETO-1-160A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003ctd\u003e440V DC\u003c\/td\u003e\n\u003ctd\u003e2 × NH00 160A Fuse-links\u003c\/td\u003e\n\u003ctd\u003eM10 lugs\u003c\/td\u003e\n\u003ctd\u003e25-150mm²\u003c\/td\u003e\n\u003ctd\u003e184 x 300 mm\u003c\/td\u003e\n\u003ctd\u003eDIN rail or panel mount\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003eKETO-1-160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes high-quality 160A NH fuse-links for effective circuit protection.\u003c\/li\u003e\n\u003cli\u003eSize 1 body provides a balance of compactness and high current capacity.\u003c\/li\u003e\n\u003cli\u003eThree-pole switch design for secure battery isolation.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty M10 terminal lugs support cables from 25mm² up to 150mm².\u003c\/li\u003e\n\u003cli\u003eFlexible DIN rail or panel mounting options to fit various installations.\u003c\/li\u003e\n\u003cli\u003eRated for 440V DC, suited for demanding renewable energy applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy Jean Muller KETO-1-160A?\u003c\/h3\u003e\n\u003cp\u003eThe Jean Muller KETO-1-160A fuse disconnector is ideal for renewable energy professionals seeking reliable battery isolation with included fuse-links. It ensures safety, durability, and ease of maintenance, making it the trusted choice for large-scale battery and solar PV systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFuses included, providing a complete disconnection solution.\u003c\/li\u003e\n\u003cli\u003eJean Muller quality trusted in industrial and renewable sectors.\u003c\/li\u003e\n\u003cli\u003eDesigned for straightforward installation and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":62603137548637,"sku":"KETO-1-160A-Kit","price":95.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/JeanMullerKETO1BatteryDisconnectorwith160AFuses.webp?v=1763378746"},{"product_id":"jean-muller-keto-1-battery-disconnector-with-200a-fuses","title":"Jean Muller KETO-1 Battery Disconnector with 2 x 200A Fuses","description":"\u003cp\u003eThe Jean Muller KETO-1-200A fuse-switch-disconnector is a high-capacity battery isolator designed for safe and reliable DC circuit protection in solar energy and battery storage applications. It features a KETO size 1 body equipped with 200A NH fuse-links, ensuring robust disconnection and protection for large battery banks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 124.643%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 8.321%;\"\u003eType\u003c\/th\u003e\n\u003cth style=\"width: 7.31675%;\"\u003ePoles\u003c\/th\u003e\n\u003cth style=\"width: 9.61219%;\"\u003eRated Current\u003c\/th\u003e\n\u003cth style=\"width: 9.61219%;\"\u003eDC Voltage Rating\u003c\/th\u003e\n\u003cth style=\"width: 10.6165%;\"\u003eFuse-links Included\u003c\/th\u003e\n\u003cth style=\"width: 11.4772%;\"\u003eTerminals\u003c\/th\u003e\n\u003cth style=\"width: 9.89913%;\"\u003eCable Area\u003c\/th\u003e\n\u003cth style=\"width: 13.4858%;\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003cth style=\"width: 11.7642%;\"\u003eMounting\u003c\/th\u003e\n\u003cth style=\"width: 7.89061%;\"\u003eMPN\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 8.321%;\"\u003e\u003cstrong\u003eKETO-1-200A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 7.31675%;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 9.61219%;\"\u003e250A\u003c\/td\u003e\n\u003ctd style=\"width: 9.61219%;\"\u003e440V DC\u003c\/td\u003e\n\u003ctd style=\"width: 10.6165%;\"\u003e2 × NH00 200A Fuse-links\u003c\/td\u003e\n\u003ctd style=\"width: 11.4772%;\"\u003eM10 lugs\u003c\/td\u003e\n\u003ctd style=\"width: 9.89913%;\"\u003e25-150mm²\u003c\/td\u003e\n\u003ctd style=\"width: 13.4858%;\"\u003e184 x 300 mm\u003c\/td\u003e\n\u003ctd style=\"width: 11.7642%;\"\u003eDIN rail or panel mount\u003c\/td\u003e\n\u003ctd style=\"width: 7.89061%;\"\u003eKETO-1-200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes high-quality 200A NH fuse-links for effective circuit protection.\u003c\/li\u003e\n\u003cli\u003eSize 1 body offers robust construction for high-current battery isolation.\u003c\/li\u003e\n\u003cli\u003eThree-pole switch design for secure disconnection of battery circuits.\u003c\/li\u003e\n\u003cli\u003eM10 terminal lugs supporting a cable area from 25mm² to 150mm².\u003c\/li\u003e\n\u003cli\u003eFlexible installation via DIN rail or panel mounting.\u003c\/li\u003e\n\u003cli\u003eRated for 440V DC applications, suitable for demanding renewable energy systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy Jean Muller KETO-1-200A?\u003c\/h3\u003e\n\u003cp\u003eThis battery disconnector provides professional-grade safety and reliability for renewable energy and battery storage systems, complete with fuse-links included for installation convenience. The Jean Muller brand ensures quality and performance trusted across the industry.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete fused disconnection solution with included 200A fuses.\u003c\/li\u003e\n\u003cli\u003eDurable and versatile for various installation environments.\u003c\/li\u003e\n\u003cli\u003eEasy maintenance and proven reliability for critical DC circuits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jean Muller","offers":[{"title":"Default Title","offer_id":62603140464989,"sku":"KETO-1-200A-Kit","price":95.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/JeanMullerKETO1BatteryDisconnectorwith160AFuses.webp?v=1763378746"},{"product_id":"jean-muller-nh-fuse-links-for-keto-1-battery-disconnector","title":"Jean Muller NH Fuse-Links for KETO-1 Battery Disconnector NH1 Size 80A 100A 125A 160A 200A DC 250V IEC60269 gL\/gG Solar Battery Inverter Protection Combi Indicator","description":"\u003cdiv style=\"font-size: 16px; font-family: 'Segoe UI',Helvetica,Arial,sans-serif; color: #222; background: transparent; max-width: 900px; line-height: 1.5;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.75; color: #333; margin: 0 0 18px;\"\u003eThese are the \u003cstrong\u003egenuine Jean Müller NH fuse-links for the KETO-1 battery disconnector\u003c\/strong\u003e — the replacement and spare fuse elements used with the \u003cstrong\u003eKETO size 1 NH fuse-switch-disconnector body\u003c\/strong\u003e in solar and battery storage DC protection applications. The KETO-1 is rated for a maximum DC current of \u003cstrong\u003e250 A at 250 V DC\u003c\/strong\u003e, and these fuse-links are available in ratings of \u003cstrong\u003e80 A, 100 A, 125 A, 160 A and 200 A\u003c\/strong\u003e to suit different battery and inverter configurations. Each KETO-1 disconnector body takes \u003cstrong\u003etwo fuse-links\u003c\/strong\u003e (one per pole — positive and negative), so order in pairs when replacing or commissioning. Built to \u003cstrong\u003eIEC 60269\u003c\/strong\u003e, gL\/gG characteristic, with a \u003cstrong\u003ecombi blown-fuse indicator\u003c\/strong\u003e on each link for rapid visual fault detection. Manufactured by Jean Müller — a specialist German electrical safety company with over 125 years of history in fuse technology.\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(110px,1fr)); gap: 10px; margin-bottom: 24px;\"\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 19px; font-weight: 800; line-height: 1.1;\"\u003eNH1 Size\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003eKETO-1 fuse format\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 19px; font-weight: 800; line-height: 1.1;\"\u003e250V DC\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003eDC voltage rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 19px; font-weight: 800; line-height: 1.1;\"\u003e80–200A\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003eAvailable ratings\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 19px; font-weight: 800; line-height: 1.1;\"\u003eIEC 60269\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003eStandard\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 19px; font-weight: 800; line-height: 1.1;\"\u003egL\/gG\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003eCharacteristic\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 19px; font-weight: 800; line-height: 1.1;\"\u003eCombi Indic.\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003eBlown-fuse indicator\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #fef2f2; border-left: 4px solid #dc2626; border-radius: 0 8px 8px 0; padding: 14px 18px; margin: 6px 0 16px; font-size: 15px; color: #7f1d1d;\"\u003e\n\u003cstrong\u003e⚠ Qualified electrician or technician installation only:\u003c\/strong\u003e DC battery protection circuits carry significant fault energy. Selection of the correct fuse rating, installation and commissioning must be performed by a \u003cstrong\u003equalified electrician or technician\u003c\/strong\u003e. All installations must adhere to local wiring regulations and standards.\u003c\/div\u003e\n\u003cdiv style=\"background: #fff8e1; border-left: 4px solid #d97706; border-radius: 0 8px 8px 0; padding: 14px 18px; margin: 6px 0 16px; font-size: 15px; color: #92400e;\"\u003e\n\u003cstrong\u003eℹ Two fuse-links required per KETO-1 disconnector:\u003c\/strong\u003e The KETO-1 is a two-pole disconnector (positive and negative conductors). Each pole carries one NH1 fuse-link. \u003cstrong\u003eOrder two fuse-links per disconnector body\u003c\/strong\u003e — one for the positive pole, one for the negative. Both fuse-links must be the same current rating.\u003c\/div\u003e\n\u003cdiv style=\"background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 8px 8px 0; padding: 14px 18px; margin: 6px 0 16px; font-size: 15px; color: #005c54;\"\u003e\n\u003cstrong\u003eℹ KETO-1 fuse-links are not interchangeable with KETO-00 fuse-links:\u003c\/strong\u003e The KETO-00 uses NH00-size fuse-links; the KETO-1 uses NH1-size fuse-links. These are different physical sizes and cannot be substituted. Check the size designation on your disconnector body before ordering. KETO-00 fuse-links are available separately.\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eFuse-Link Rating Selection — Choose the Correct Ampere Rating\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0 0 12px;\"\u003eSelect the fuse rating based on the maximum continuous DC current of your battery system with an appropriate safety margin applied. The fuse rating should typically be set at \u003cstrong\u003e125 % of the maximum continuous battery current\u003c\/strong\u003e to allow for brief transients while still protecting against sustained overcurrent faults.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: 'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #008377; color: #fff;\"\u003e\n\u003cth style=\"padding: 9px 12px; text-align: left; font-size: 13px; font-weight: bold;\"\u003eRating\u003c\/th\u003e\n\u003cth style=\"padding: 9px 12px; text-align: left; font-size: 13px; font-weight: bold;\"\u003eJean Müller Part No.\u003c\/th\u003e\n\u003cth style=\"padding: 9px 12px; text-align: left; font-size: 13px; font-weight: bold;\"\u003eTypical use case\u003c\/th\u003e\n\u003cth style=\"padding: 9px 12px; text-align: left; font-size: 13px; font-weight: bold;\"\u003eMax system current (at 125% factor)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0; font-weight: bold; color: #005c54;\"\u003e80 A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003eN1013907 (M1gL80)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003eSmall 12V battery banks; low-current DC systems\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003e~64 A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0; font-weight: bold; color: #005c54;\"\u003e100 A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003eN1014207 (M1gL100)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003eMid-size residential battery storage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003e~80 A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0; font-weight: bold; color: #005c54;\"\u003e125 A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003eN1014605 (M1gL125)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003e5 – 10 kWh storage at 48V; standard hybrid inverter DC feeds\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003e~100 A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0; font-weight: bold; color: #005c54;\"\u003e160 A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003eN1014905 (M1gL160)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003eHigh-capacity residential or light commercial systems; larger 48V banks\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003e~128 A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0; font-weight: bold; color: #005c54;\"\u003e200 A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003eN1015205 (M1gL200)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003eLarge battery banks; commercial storage; high-power inverters\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003e~160 A continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #666; margin: -12px 0 20px;\"\u003ePart numbers shown are Jean Müller manufacturer references. Always size fuses based on a full fault current calculation by a qualified engineer. The 125 % guidance is a starting point, not a substitute for a proper system design assessment.\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eHow to Choose Your Fuse Rating\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0 0 14px;\"\u003eNH fuse-links in battery DC circuits must be sized to protect the cable, not to match the inverter’s input current rating. The correct sizing method follows these steps:\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(260px,1fr)); gap: 10px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"background: #f0f9f8; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #008377;\"\u003e\n\u003cdiv style=\"font-size: 14px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e1. Determine maximum battery current\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444; line-height: 1.5;\"\u003eFind the maximum continuous discharge current of your battery bank in amps. For example: a 10 kWh system at 48 V nominal discharging at 5 kW = 5,000 W ÷ 48 V = approximately 104 A.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f8f8f8; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #008377;\"\u003e\n\u003cdiv style=\"font-size: 14px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e2. Check the cable rating\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444; line-height: 1.5;\"\u003eThe fuse must not exceed the rating of the DC cable it protects. Select a fuse-link rating equal to or below the cable’s current-carrying capacity (derated for installation conditions). The cable is the protected component.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0f9f8; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #008377;\"\u003e\n\u003cdiv style=\"font-size: 14px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e3. Apply the 125 % rule\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444; line-height: 1.5;\"\u003eSize the fuse at no more than 125 % of the maximum continuous current to allow for brief transients without nuisance tripping. For 104 A continuous: 104 × 1.25 = 130 A → select the 125 A fuse.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f8f8f8; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #008377;\"\u003e\n\u003cdiv style=\"font-size: 14px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e4. Verify against KETO-1 maximum\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444; line-height: 1.5;\"\u003eThe KETO-1 body is rated to a maximum DC current of 250 A. Do not select a fuse rating above 250 A for a single KETO-1 disconnector. For higher currents, a KETO-2 body (rated 400 A) would be required.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0f9f8; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #008377;\"\u003e\n\u003cdiv style=\"font-size: 14px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e5. Always use a qualified engineer\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444; line-height: 1.5;\"\u003eBattery fault currents can be extremely high and potentially lethal. Fuse selection must be verified by a qualified electrician who can perform a full fault current calculation for the specific installation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eGenuine Jean Müller Components — Designed Specifically for the KETO-1 Body\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThese are \u003cstrong\u003egenuine Jean Müller NH1 fuse-links\u003c\/strong\u003e, not generic NH1 fuses. While dimensionally compliant with the NH1 standard, Jean Müller design their KETO fuse-links as an integrated system with the KETO disconnector body — matching the contact interface, striker mechanism, and indicator window geometry. Using non-genuine or generic NH1 fuse-links can result in poor contact reliability, incorrect indicator function or failure to seat correctly.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eGenuine Jean Müller\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eNH1 size\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eKETO-1 compatible\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003egL\/gG Characteristic — Full-Range Overcurrent Protection\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe \u003cstrong\u003egL\/gG characteristic\u003c\/strong\u003e means the fuse provides \u003cstrong\u003efull-range protection\u003c\/strong\u003e: both overload protection (the ‘g’ prefix) and short-circuit protection (the ‘L’\/‘G’ suffix). An overload (moderate overcurrent sustained over time) causes the fuse to blow gradually; a short-circuit causes it to clear in milliseconds. This dual protection is exactly what is required between a battery bank and an inverter, where both conditions must be guarded against.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003egL\/gG full-range protection\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eOverload + short-circuit\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eIEC 60269\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eCombi Indicator — Instant Visual Blown-Fuse Detection\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eEach fuse-link includes a \u003cstrong\u003ecombi indicator\u003c\/strong\u003e: a visual striker that activates when the fuse element blows. Without this indicator, identifying a blown fuse in a DC battery circuit requires a voltage measurement across each fuse — a time-consuming and potentially dangerous process if the battery is still energised. The combi indicator makes fault identification immediate and safe, reducing diagnostic time significantly.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eCombi indicator (visual striker)\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eInstant fault identification\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e250 V DC Rating — Correct for Battery DC Applications\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eMany standard NH fuse-links are rated for AC applications only or are not rated for DC use at all. AC fuses cannot be used in DC circuits because the lack of a natural current zero-crossing means the arc generated when the fuse clears does not extinguish in the same way. These Jean Müller fuse-links carry an explicit \u003cstrong\u003e250 V DC voltage rating\u003c\/strong\u003e, confirming they are designed and tested for DC battery circuit protection where the KETO-1 body is used.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e250V DC rated\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eDC arc extinction tested\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eNot AC-only\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eHalogen-Free, Self-Extinguishing Materials\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe fuse-link body is manufactured from \u003cstrong\u003ehalogen-free, self-extinguishing materials\u003c\/strong\u003e. In the event of a fault, the fuse body will not propagate flame or emit toxic halogen gases. This is a critical fire safety property for enclosures mounted in battery storage installations, where the risk of secondary fires or toxic gas release during a fault event must be minimised. Compliance with IEC 60269 includes testing of the arc extinction and post-fault safety of the fuse body.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eHalogen-free\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eSelf-extinguishing\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eIEC 60269\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eEN 60947-3 Compliant KETO-1 System\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe KETO-1 disconnector body to which these fuses are fitted is designed and tested to \u003cstrong\u003eEN 60947-3\u003c\/strong\u003e (the standard for switch-disconnectors and fuse-combination units). Compliance with this standard verifies that the complete switching and protection system — disconnector body plus fuse-link — performs correctly under the rated conditions, including make and break operations, fault clearance, and temperature rise limits. This is important for UK BS 7671 and IET Wiring Regulations compliance in battery storage installations.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eEN 60947-3 system compliance\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eBS 7671 compatible\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eKETO-1 Body Quick Reference\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0 0 12px;\"\u003eThese fuse-links are designed for use with the KETO size 1 disconnector body. Key KETO-1 body specifications for reference:\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: 'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eKETO-1 Disconnector Body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMaximum DC current (Ie)\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eDC voltage rating\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eOverall width\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e184 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eSystem size\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eTerminals\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eM10 lugs, 25 – 150 mm² cable capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eBaseplate \/ DIN-rail \/ busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e2-pole (positive + negative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eFuse size accepted\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eNH1 (this product)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eEN 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eRelated product\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eJean Müller NH Fuse-Links for KETO-00 (NH00 size — sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 24px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: 'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eNH Fuse-Link Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eFuse size\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eNH1 (for KETO-1 body)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eAvailable current ratings\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e80 A, 100 A, 125 A, 160 A, 200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eVoltage rating (DC)\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eCharacteristic\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003egL\/gG (full-range overload + short-circuit protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eIndicator\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eCombi indicator (visual striker on blown fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMaterial\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eHalogen-free, self-extinguishing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eIEC 60269\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eQuantity per order\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e1 fuse-link (order 2 per KETO-1 disconnector body)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eCompatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eCompatible disconnector body\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eJean Müller KETO-1 (size 1) only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eNOT compatible with\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eKETO-00 body (uses NH00 fuse-links — different physical size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eDC protection between battery bank and inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eManufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eJean Müller (Jean Müller GmbH \u0026amp; Co. KG, founded 1897)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhy do I need two fuse-links per KETO-1 disconnector?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eThe KETO-1 is a \u003cstrong\u003etwo-pole disconnector\u003c\/strong\u003e — it breaks both the positive and negative DC conductors simultaneously. Each pole has its own fuse-link. Breaking both conductors is essential in a DC battery circuit: unlike AC, DC has no natural current zero-crossing, so a fault cannot self-extinguish if only one conductor is broken. Both poles must be fused and isolated together. The KETO-1 body is supplied without fuse-links — you select the appropriate current rating for your application.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eCan I use a standard NH1 fuse-link from another manufacturer?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eThe NH1 fuse-link is a standardised size under IEC 60269, so physically any NH1 fuse-link will fit in the KETO-1 body. However, for the \u003cstrong\u003ecombi indicator\u003c\/strong\u003e to function correctly, the fuse-link must be compatible with the KETO body’s indicator mechanism. Non-Jean-Müller NH1 fuse-links may not trigger the KETO indicator correctly. Jean Müller recommend using their own fuse-links with the KETO body to guarantee the indicator and contact interface perform as designed.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhat is the difference between gL, gG and aM fuse characteristics?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003e\n\u003cstrong\u003egL\/gG\u003c\/strong\u003e fuses provide \u003cstrong\u003efull-range protection\u003c\/strong\u003e: they protect against both sustained overloads and short-circuits across the entire current range. They are the correct choice for protecting cables and general DC loads. \u003cstrong\u003eaM\u003c\/strong\u003e (motor starting) fuses provide \u003cstrong\u003eback-up protection only\u003c\/strong\u003e: they only clear short-circuits and high overcurrents; they do not provide overload protection for the cable. For DC battery-to-inverter protection, \u003cstrong\u003egL\/gG is the correct characteristic\u003c\/strong\u003e. aM fuses must not be used for cable protection.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eHow do I know if a fuse-link has blown?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eThe \u003cstrong\u003ecombi indicator\u003c\/strong\u003e on each fuse-link provides a visual signal when the fuse element has ruptured. Without the indicator, you would need to use a voltmeter across each fuse-link (with the circuit live) or a continuity tester (with the circuit isolated) to identify a blown fuse. With the indicator, a visual inspection of the disconnector window is sufficient. After identifying and replacing a blown fuse, always investigate and rectify the fault that caused the fuse to blow before restoring power.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eCan I replace just one fuse-link if only one has blown?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eTechnically yes — the fuse-links are individual components. However, if one fuse in a pair blows, the other fuse has experienced the same fault current and may be close to or at the end of its service life. Best practice in a two-pole DC circuit is to \u003cstrong\u003ereplace both fuse-links simultaneously\u003c\/strong\u003e to ensure both poles have matched and verified protection. Also check the cable and all connections for damage before re-energising.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhat is the maximum DC voltage the KETO-1 system can handle?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eThe KETO-1 disconnector body is rated at \u003cstrong\u003e250 V DC\u003c\/strong\u003e. For low-voltage battery systems (12 V, 24 V, 48 V nominal) this is more than sufficient. For high-voltage battery systems (e.g. Pylontech PowerCube H1\/H2 at 200 – 1,000 V DC), the KETO-1 is \u003cstrong\u003enot suitable\u003c\/strong\u003e. High-voltage DC battery protection requires fuse switches and fuse-links specifically rated for the system voltage. Always verify the complete circuit voltage before selecting any DC protection device.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eRelated Products\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(210px,1fr)); gap: 10px; margin-bottom: 10px;\"\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eJean Müller KETO-1 Fuse-Switch Disconnector Body\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eThe disconnector body these fuse-links are designed for\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eJean Müller NH Fuse-Links for KETO-00\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eNH00-size fuse-links for the smaller KETO-00 body\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eJean Müller KETO-1 Battery Disconnector with Fuses\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eKETO-1 body supplied with a matched pair of fuse-links\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003ePylontech PowerCube H2 H48074 Battery Module\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eHigh-voltage LFP battery for larger solar + storage systems\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Jean Muller","offers":[{"title":"80A for Keto 1","offer_id":62603391238493,"sku":"N1014105-80A","price":6.0,"currency_code":"GBP","in_stock":true},{"title":"100A for Keto 1","offer_id":62603391271261,"sku":"N1014305-100A","price":7.7,"currency_code":"GBP","in_stock":true},{"title":"125A for Keto 1","offer_id":62603391304029,"sku":"N1014605-125A","price":7.7,"currency_code":"GBP","in_stock":true},{"title":"160A for Keto 1","offer_id":62603391336797,"sku":"N1014905-160A","price":6.0,"currency_code":"GBP","in_stock":true},{"title":"200A for Keto 1","offer_id":62603391369565,"sku":"200A-N1015205","price":6.0,"currency_code":"GBP","in_stock":true},{"title":"250A for Keto 1","offer_id":62603391402333,"sku":"N1015605-250A","price":9.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/JeanMullerNHFuse-linksforKETO-1BatteryDisconnector.jpg?v=1763379688"},{"product_id":"jean-muller-nh-fuse-links-for-keto-00-battery-disconnector","title":"Jean Muller NH Fuse-links for KETO-00 Battery Disconnector","description":"\u003cp\u003eEnhance your Jean Muller KETO-00 battery disconnectors with these genuine NH fuse-links, specifically designed to provide optimal DC protection and easy maintenance in renewable energy systems. These fuse-links fit perfectly with the KETO size 00 body, meeting stringent IEC and DIN safety standards.\u003c\/p\u003e\n\u003ch3\u003eAvailable Fuse-Link Variants\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eRated Current (A)\u003c\/th\u003e\n\u003cth\u003eVoltage Rating\u003c\/th\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003cth\u003eFeatures\u003c\/th\u003e\n\u003cth\u003eMPN\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eN5013407-40A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003eAC 500V\u003c\/td\u003e\n\u003ctd\u003eNH00\u003c\/td\u003e\n\u003ctd\u003eCombi indicator, isolated gripping lugs according to IEC 60269 and DIN VDE 0636-2\u003c\/td\u003e\n\u003ctd\u003eN5013407-40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eN5014107-80A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003ctd\u003eAC 500V\u003c\/td\u003e\n\u003ctd\u003eNH00\u003c\/td\u003e\n\u003ctd\u003eCombi indicator, isolated gripping lugs according to IEC 60269 and DIN VDE 0636-2\u003c\/td\u003e\n\u003ctd\u003eN5014107-80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eN5014307-100A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003ctd\u003eAC 500V\u003c\/td\u003e\n\u003ctd\u003eNH00\u003c\/td\u003e\n\u003ctd\u003eCombi indicator, isolated gripping lugs according to IEC 60269 and DIN VDE 0636-2\u003c\/td\u003e\n\u003ctd\u003eN5014307-100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eN5014607-125A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003ctd\u003eAC 500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Jean Muller","offers":[{"title":"40A for KETO-00","offer_id":62603417878877,"sku":"N5013407-40A","price":4.5,"currency_code":"GBP","in_stock":true},{"title":"80A for KETO-00","offer_id":62603417911645,"sku":"N5014107-80A","price":3.95,"currency_code":"GBP","in_stock":true},{"title":"100A for KETO-00","offer_id":62603417944413,"sku":"100A-N5014307","price":4.95,"currency_code":"GBP","in_stock":true},{"title":"125A for KETO-00","offer_id":62603417977181,"sku":"125A-N5014607","price":5.95,"currency_code":"GBP","in_stock":true},{"title":"160A for KETO-00","offer_id":62603418009949,"sku":"N5014907-160A","price":6.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/JeanMullerNHFuse-linksforKETO-00BatteryDisconnector.webp?v=1763380439"},{"product_id":"kraus-naimer-ac-isolators","title":"Kraus \u0026 Naimer AC Isolators","description":"\u003ch2\u003eKraus \u0026amp; Naimer AC Isolators Switch Disconnectors\u003c\/h2\u003e\n\n\u003ch3\u003eAC Switch Disconnectors Variants\u003c\/h3\u003e\n\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG100-T203-GBA270\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Single Phase AC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG100-T204-GBA290\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Three Phase AC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG160 T204-GBA290 ST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Three Phase AC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e160A\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG20-T203-GBA294\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Single Phase AC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG20-T204-GBA486\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Three Phase AC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG250 T204-GBA290 ST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Three Phase AC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG32-T203-GBA294\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Single Phase AC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG32-T204-GBA486\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Three Phase AC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG41-T203-GBA270\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Single Phase AC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG41-T204-GBA290\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Three Phase AC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG64-T203-GBA270\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Single Phase AC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e64A\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG64-T204-GBA290\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Three Phase AC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG80-T204-GBA290\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Three Phase AC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003c\/h3\u003e\n\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe Circuit Isolation:\u003c\/strong\u003e Provides visible and reliable disconnection of electrical circuits, ensuring safety during maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Breaking Capacity:\u003c\/strong\u003e Designed to interrupt short-circuit currents and protect equipment from damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Operation:\u003c\/strong\u003e Clear ON\/OFF control with visible position indicator for quick operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Applications:\u003c\/strong\u003e Compatible with both AC and DC circuits, suitable for renewable energy, industrial, and commercial installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e Durable materials ensure long service life in harsh environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Choose Kraus \u0026amp; Naimer AC\/DC Switch Disconnectors?\u003c\/h3\u003e\n\n\u003cp\u003eKraus \u0026amp; Naimer switch disconnectors are trusted solutions for reliable and safe circuit isolation in various electrical systems. Their proven durability, safety features, and ease of operation make them the preferred choice for installers and engineers working with both AC and DC power systems. Whether used in photovoltaic setups or industrial power distribution, these switches help protect personnel, equipment, and ensure compliance with safety standards.\u003c\/p\u003e","brand":"Kraus \u0026 Naimer","offers":[{"title":"Single Phase AC Switch Disconnector 25A","offer_id":62603583127901,"sku":"KG20-T203-GBA294","price":33.0,"currency_code":"GBP","in_stock":true},{"title":"Single Phase AC Switch Disconnector 32A","offer_id":62603583226205,"sku":"KG32-T203-GBA294","price":37.0,"currency_code":"GBP","in_stock":true},{"title":"Single Phase AC Switch Disconnector 40A","offer_id":62603583291741,"sku":"KG41-T203-GBA270","price":53.0,"currency_code":"GBP","in_stock":true},{"title":"Single Phase AC Switch Disconnector 64A","offer_id":62603609866589,"sku":"KG64-T203-GBA270","price":47.0,"currency_code":"GBP","in_stock":true},{"title":"Single Phase AC Switch Disconnector 100A","offer_id":62603583029597,"sku":"KG100-T203-GBA270","price":117.0,"currency_code":"GBP","in_stock":true},{"title":"Three Phase AC Switch Disconnector 25A","offer_id":62603583160669,"sku":"KG20-T204-GBA486","price":39.0,"currency_code":"GBP","in_stock":true},{"title":"Three Phase AC Switch Disconnector 32A","offer_id":62603583258973,"sku":"KG32-T204-GBA486","price":45.0,"currency_code":"GBP","in_stock":true},{"title":"Three Phase AC Switch Disconnector 40A","offer_id":62603583324509,"sku":"KG41-T204-GBA290","price":59.0,"currency_code":"GBP","in_stock":true},{"title":"Three Phase AC Switch Disconnector 63A","offer_id":62603609899357,"sku":"KG64-T204-GBA290","price":70.0,"currency_code":"GBP","in_stock":true},{"title":"Three Phase AC Switch Disconnector 80A","offer_id":62603609932125,"sku":"KG80-T204-GBA290","price":115.0,"currency_code":"GBP","in_stock":true},{"title":"Three Phase AC Switch Disconnector 100A","offer_id":62603583062365,"sku":"KG100-T204-GBA290","price":135.0,"currency_code":"GBP","in_stock":true},{"title":"Three Phase AC Switch Disconnector 160A","offer_id":62603583095133,"sku":"KG160 T204-GBA290 ST","price":495.0,"currency_code":"GBP","in_stock":true},{"title":"Three Phase AC Switch Disconnector 250A","offer_id":62603583193437,"sku":"KG250 T204-GBA290 ST","price":590.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/K_NSinglePhaseACSwitchDisconnector.webp?v=1763446452"},{"product_id":"kraus-naimer-dc-isolators","title":"Kraus \u0026 Naimer DC Switch Disconnectors","description":"\u003ch2\u003eKraus \u0026amp; Naimer DC Switch Disconnectors\u003c\/h2\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe Circuit Isolation:\u003c\/strong\u003e Provides visible and reliable disconnection of electrical circuits, ensuring safety during maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Breaking Capacity:\u003c\/strong\u003e Designed to interrupt short-circuit currents and protect equipment from damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Operation:\u003c\/strong\u003e Clear ON\/OFF control with visible position indicator for quick operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Applications:\u003c\/strong\u003e Compatible with both AC and DC circuits, suitable for renewable energy, industrial, and commercial installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e Durable materials ensure long service life in harsh environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG20B-T106D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Single String DC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e21A\u003c\/td\u003e\n\u003ctd\u003e800V - 1000V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG20B-T106GB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Dual String DC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e25A (per string)\u003c\/td\u003e\n\u003ctd\u003e330V - 600V\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG20-T104D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Single String DC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003e450V - 800V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG20-T104GB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Dual String DC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e25A (per string)\u003c\/td\u003e\n\u003ctd\u003e220V - 400V\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKG32B-T106D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u0026amp;N Single String DC Switch Disconnector\u003c\/td\u003e\n\u003ctd\u003e27A\u003c\/td\u003e\n\u003ctd\u003e800V - 1000V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eWhy Choose Kraus \u0026amp; Naimer AC\/DC Switch Disconnectors?\u003c\/h3\u003e\n\u003cp\u003eKraus \u0026amp; Naimer switch disconnectors are trusted solutions for reliable and safe circuit isolation in various electrical systems. Their proven durability, safety features, and ease of operation make them the preferred choice for installers and engineers working with both AC and DC power systems. Whether used in photovoltaic setups or industrial power distribution, these switches help protect personnel, equipment, and ensure compliance with safety standards.\u003c\/p\u003e","brand":"Kraus \u0026 Naimer","offers":[{"title":"21A 800V - 20A 1000V","offer_id":62613784723805,"sku":"KG20B-T106D","price":57.0,"currency_code":"GBP","in_stock":true},{"title":"25A 330V - 18A 600V (per string)","offer_id":62613784756573,"sku":"KG20B-T106GB","price":37.0,"currency_code":"GBP","in_stock":true},{"title":"25A 450V - 18A 800V","offer_id":62613784789341,"sku":"KG20-T104D","price":39.0,"currency_code":"GBP","in_stock":true},{"title":"25A 220V - 18A 400V (per string)","offer_id":62613784822109,"sku":"KG20-T104GB","price":39.0,"currency_code":"GBP","in_stock":true},{"title":"27A 800V - 25A 1000V","offer_id":62613784854877,"sku":"KG32B-T106D","price":65.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Kraus_NaimerACIsolatorstwoswitches.png?v=1763446452"},{"product_id":"projoy-ac-isolators","title":"Projoy PEAS AC Isolator Solar PV - 20A 25A 32A 40A 4-Pole IP66 Lockable IEC EN 60947-3 BS 7671 Compliant","description":"\u003c!-- SEO Product Name: Projoy PEAS AC Isolator Solar PV - 20A 25A 32A 40A 4-Pole IP66 Lockable IEC EN 60947-3 BS 7671 Compliant --\u003e\n\u003cdiv style=\"font-size: 16px; font-family: 'Segoe UI',Helvetica,Arial,sans-serif; color: #222; background: #fff; max-width: 900px; line-height: 1.5;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.75; color: #333; margin: 0 0 18px;\"\u003eThe \u003cstrong\u003eProjoy PEAS Series AC Isolator\u003c\/strong\u003e provides the \u003cstrong\u003eAC-side isolation required at the output of every grid-connected solar PV inverter\u003c\/strong\u003e under BS 7671 (18th Edition) and MCS installation standards. Available in \u003cstrong\u003e20A, 25A, 32A and 40A ratings (4-pole)\u003c\/strong\u003e, covering single-phase and three-phase inverters from approximately 1.5 kW to 9 kW output. The \u003cstrong\u003eIP66 polycarbonate enclosure\u003c\/strong\u003e is suitable for outdoor and exposed installations. The rotary handle \u003cstrong\u003elocks in the OFF position with a padlock\u003c\/strong\u003e for safe isolation during maintenance. Four mounting options: \u003cstrong\u003epanel mount, DIN rail, door clutch and standalone enclosure\u003c\/strong\u003e. \u003cstrong\u003eSilver-alloy contacts\u003c\/strong\u003e for low resistance and extended electrical life. Certified to \u003cstrong\u003eIEC\/EN 60947-3\u003c\/strong\u003e. CE and TUV approved. \u003cstrong\u003eISO 9001 and ISO 14001\u003c\/strong\u003e certified manufacture.\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(130px,1fr)); gap: 10px; margin-bottom: 24px;\"\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003e20–40A\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eCurrent Range\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003e4-Pole\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eConfiguration\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003eIP66\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eEnclosure\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003e440V AC\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eMax Voltage\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003eCE + TUV\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eCertified\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003eISO 9001\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eQuality\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #fff8e1; border-left: 4px solid #f0a500; border-radius: 0 8px 8px 0; padding: 14px 18px; margin: 6px 0 16px; font-size: 15px; color: #5a4000;\"\u003e\n\u003cstrong\u003e⚠ Qualified Installer Required:\u003c\/strong\u003e AC isolators for grid-connected PV systems must be installed by a suitably qualified and competent person to BS 7671 and MCS standards.\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eVariant Overview — Which Rating Do You Need?\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: 'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #008377; color: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003eRating\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003eInverter Output (single-phase approx.)\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003eTypical System Size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f9f8;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e20A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e4P\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eUp to ~4.6 kW\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e1–2 bedroom, ~2–4 kWp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e25A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e4P\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eUp to ~5.75 kW\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e2–3 bedroom, ~3–5 kWp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f9f8;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e4P\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eUp to ~7.4 kW\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e3–4 bedroom, ~5–7 kWp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e40A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e4P\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eUp to ~9.2 kW\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eLarger homes \/ multi-string, ~6–9 kWp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f9f8;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e63A+\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e4P\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eLarger 3-phase or higher-output systems\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePEAS 63–80A series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #666; margin: -12px 0 20px;\"\u003eSelect the rating at or above the inverter manufacturer's rated maximum AC output current. For 3-phase: divide total inverter output by (400V x 1.732) for per-phase current.\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eBS 7671-Required AC Isolation for Grid-Connected PV Inverters\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eBS 7671 (18th Edition Amendment 1) requires a \u003cstrong\u003elockable means of isolation on the AC output side\u003c\/strong\u003e of every grid-connected PV inverter. This must be separate from the DC isolation provided by the inverter’s internal switch or an external firefighter safety switch. The PEAS is rated and certified to \u003cstrong\u003eIEC\/EN 60947-3\u003c\/strong\u003e specifically as an isolator-disconnector — exactly the device type referenced in BS 7671 for this purpose.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eBS 7671 compliant\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eIEC\/EN 60947-3\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eIsolator-disconnector rated\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eLockable in OFF Position — Padlock Compatible\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe rotary handle can be turned to the OFF position and a standard padlock passed through the hasp to \u003cstrong\u003ephysically prevent re-energisation\u003c\/strong\u003e. This satisfies the Electricity at Work Regulations 1989 requirement for secure isolation during maintenance work on the inverter, wiring or downstream equipment. Clear ON\/OFF position markings are provided on the handle and body.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003ePadlock in OFF\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eElectricity at Work Regs\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eClear position marking\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eIP66 — Weatherproof for External and Exposed Installation\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eEnclosure variants carry an \u003cstrong\u003eIP66 rating\u003c\/strong\u003e — fully dustproof and protected against high-pressure water jets from any direction. Suitable for outdoor meter box mounting, external wall positions alongside the inverter, garages, outbuildings and exposed roof level. Enclosure body is UL 94 V-0 flame-retardant polycarbonate.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eIP66\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eOutdoor-rated\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eV-0 polycarbonate\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eFour Mounting Options — Adapts to Any Installation\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eAvailable in: \u003cstrong\u003estandalone enclosure\u003c\/strong\u003e (IP66, wall-mounted); \u003cstrong\u003epanel mount\u003c\/strong\u003e (bolted to enclosure backplate or surface); \u003cstrong\u003eDIN rail\u003c\/strong\u003e (snap-fit to 35mm DIN rail in a consumer unit); \u003cstrong\u003edoor clutch\u003c\/strong\u003e (handle on door, mechanism on chassis — common for integrated inverter cabinet installations). All use the same switch mechanism.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eStandalone enclosure\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003ePanel mount\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eDIN rail\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eDoor clutch\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eSilver-Alloy Contacts — Low Resistance, Long Life\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eSilver-alloy contacts provide \u003cstrong\u003elower contact resistance than copper\u003c\/strong\u003e, better arc resistance, and longer rated electrical lifespan under repeated switching. In PV installations where the isolator may carry maximum current for extended periods during peak generation, low contact resistance matters for both efficiency and contact temperature management.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eSilver-alloy contacts\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eLow contact resistance\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eLong electrical life\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eCE and TUV Certified — ISO 9001 and ISO 14001 Manufacture\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe PEAS carries \u003cstrong\u003eCE and TUV approvals\u003c\/strong\u003e. Projoy Electric holds \u003cstrong\u003eISO 9001 quality management\u003c\/strong\u003e and \u003cstrong\u003eISO 14001 environmental management\u003c\/strong\u003e system certifications. All products undergo rigorous environmental and electrical testing. Projoy’s full DC isolator range has also obtained \u003cstrong\u003eUKCA certification\u003c\/strong\u003e for the UK market.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eCE + TUV\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eUKCA (DC range)\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eISO 9001 + 14001\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 24px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: 'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\" colspan=\"2\"\u003ePEAS Series — Electrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eCurrent Ratings Available\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e20A, 25A, 32A, 40A (this range); 63A, 80A (PEAS 63–80A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMax AC Voltage\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e440V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eNominal AC Voltage\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e230V \/ 400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e4P (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eContact Material\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eSilver alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\" colspan=\"2\"\u003ePhysical and Environmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eIP Rating (Enclosure)\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eFlame Retardant\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eUL 94 V-0 (enclosure body)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMounting Options\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003ePanel, DIN Rail, Door Clutch, Standalone Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eHandle\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eRotary, lockable in OFF position with padlock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\" colspan=\"2\"\u003eStandards and Certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eTest Standard\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eIEC\/EN 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eCE, TUV, ISO 9001, ISO 14001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eAdditional\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eUKCA (Projoy full DC isolator series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\" colspan=\"2\"\u003eApplications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePrimary Use\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eAC isolation at PV inverter output — BS 7671 \/ MCS compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eSecondary Uses\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eMotor control, industrial AC disconnect, emergency isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eProjoy Electric Co.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhere in a solar PV system is the AC isolator installed?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eBetween the \u003cstrong\u003einverter AC output and the consumer unit\u003c\/strong\u003e (or AC distribution board). It should be mounted close to the inverter, clearly labelled as a PV AC isolator, and accessible for operation. This is a BS 7671 requirement for all grid-connected PV systems.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhich current rating do I need?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eSelect at or above the inverter's maximum rated AC output current. For a 3.6 kW single-phase inverter: 3600 ÷ 230 = 15.7A → use 20A. For a 5 kW inverter: 21.7A → use 25A. For a 7 kW inverter: 30.4A → use 32A. Always verify against the specific inverter datasheet.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eIs the AC isolator needed if I already have a PEFS-EL firefighter safety switch?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eYes. The PEFS-EL handles DC string isolation only. The AC isolator is a \u003cstrong\u003eseparate, independent requirement\u003c\/strong\u003e for the AC output side. BS 7671 and MCS require both — they serve different purposes and different parts of the circuit.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhat does lockable in the OFF position mean in practice?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eThe rotary handle is turned to OFF, then a padlock is inserted through the hasp on the handle to physically prevent it being rotated back to ON. This provides the \u003cstrong\u003esecure isolation\u003c\/strong\u003e required by the Electricity at Work Regulations 1989 before working on the inverter or downstream wiring.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eIs a 4-pole isolator needed for a single-phase system?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eFor single-phase PV, a \u003cstrong\u003e2-pole isolator\u003c\/strong\u003e would technically cover L and N, but a 4-pole device is commonly specified because it also isolates the PE (earth) conductor where relevant. Many MCS installers and DNOs specify a 4-pole device as standard practice for unambiguous system isolation. Check your specific DNO and MCS requirements.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eRelated Products\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(220px,1fr)); gap: 10px; margin-bottom: 10px;\"\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eProjoy PEFS-EL Firefighter Safety Switch (2-string, 40A FB)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eDC string rapid shutdown — pairs with this AC isolator\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eProjoy PEFS-EL Firefighter Safety Switch (5-string, 20A)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eDC string shutdown for mid-size arrays\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eProjoy PEFS-EL Firefighter Safety Switch (10-string, 20A)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eDC string shutdown for larger arrays\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eProjoy Battery Isolator PEBS-L with Enclosure\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eDC MCB for battery-inverter isolation\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Projoy Electric","offers":[{"title":"25A 3pole","offer_id":62613838135645,"sku":"PEAS69-EL25R-3","price":8.95,"currency_code":"GBP","in_stock":true},{"title":"32A 4pole","offer_id":62613838168413,"sku":"PEAS69-EL32R-4","price":9.95,"currency_code":"GBP","in_stock":true},{"title":"32A 4pole for 1ph","offer_id":62613838201181,"sku":"PEAS69-EL32R-4-1P","price":9.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/ProjoyACIsolators.webp?v=1763447556"},{"product_id":"projoy-dc-isolators","title":"Projoy PEDS DC Isolator Solar PV - 1500V 16A 25A 32A 2-Pole 4-Pole IP66 String Inverter","description":"\u003c!-- SEO Product Name: Projoy PEDS DC Isolator Solar PV - 1500V 16A 25A 32A 2-Pole 4-Pole IP66 UKCA TUV IEC EN 60947-3 BS 7671 String Inverter --\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003eThe \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003eProjoy PEDS Series DC Isolator\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e is a \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003epurpose-built DC isolator-disconnector for solar PV systems\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e, providing the externally accessible, lockable means of DC isolation required by \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003eBS 7671 (18th Edition)\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e at every grid-connected string inverter. The PEDS-EL enclosure series is the most common variant: a \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003ecompact IP66 weatherproof unit\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e with a three-position lockable rotary handle, available in \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e16A, 25A and 32A ratings\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e across \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e2-pole (1 string) and 4-pole (2 string) configurations\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e, rated to \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e1500V DC\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e. The switching mechanism uses an \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003eenergy-storage spring\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e to separate contacts in under \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e5 milliseconds\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e — regardless of handle speed — quenching DC arcs before they can cause damage. Dual \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003emagnetic and gate arc suppression\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e, self-cleaning contacts and \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e−40°C to +70°C full-load operating range\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e. Enclosure body uses \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003eUL 94 V-0 imported flame-retardant material\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e with a \u0026gt;300°C deformation point. Certified to \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003eIEC\/EN 60947-3, TUV, CE, CB, SAA, UL and UKCA\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e. Also available in single-hole, panel-mount, DIN-rail and door-clutch variants for integration into inverter cabinets or combiner boxes. Higher-current 40A and 55A variants available in the PEDS150H series.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; font-family: 'Segoe UI',Helvetica,Arial,sans-serif; color: #222; background: #fff; max-width: 900px; line-height: 1.5;\"\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(130px,1fr)); gap: 10px; margin-bottom: 24px;\"\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003e1500V\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eDC Rated\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003e5ms\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eSpring Trip\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003eIP66\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eEnclosure\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003e−40\/+70°C\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eTemp Range\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003eUKCA\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eUK Certified\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003eV-0\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eFlame Retardant\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #fff8e1; border-left: 4px solid #f0a500; border-radius: 0 8px 8px 0; padding: 14px 18px; margin: 6px 0 16px; font-size: 15px; color: #5a4000;\"\u003e\n\u003cstrong\u003e⚠ Qualified Installer Required:\u003c\/strong\u003e DC isolators for grid-connected PV systems must be installed by a suitably qualified and competent person in accordance with BS 7671, IEC 60364-7-712 and MCS installation standards. Isolators must be correctly rated for the system voltage and current, and clearly labelled.\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eVariant Overview — Enclosure Series (PEDS-EL) and Mounting Options\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 8px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: 'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #008377; color: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003ePart Number (example)\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003eCurrent\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003eStrings\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003eTypical Application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f9f8;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePEDS150-EL16R-2\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e16A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e2P\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e1 string\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eIP66 enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eSmall single-string inverters up to ~3.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePEDS150-EL25R-2\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e25A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e2P\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e1 string\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eIP66 enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eSingle-string inverters up to ~5.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f9f8;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePEDS150-EL32R-2\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e2P\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e1 string\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eIP66 enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eSingle-string inverters up to ~7.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePEDS150-EL25R-4\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e25A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e4P\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e2 strings\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eIP66 enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eDual-MPPT inverters, 2 independent strings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f9f8;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePEDS150-EL32R-4\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e32A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e4P\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e2 strings\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eIP66 enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eDual-MPPT inverters, up to ~7.4 kW per string\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePEDS150-EL40R-4\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e40A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e4P\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e2 strings\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eIP66 enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eHigher-current dual-string, e.g. parallel panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f9f8;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePanel\/hole mount (bare)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e16–32A\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e2P\/4P\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e1–2 strings\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eNo enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eFor integration into existing inverter cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #666; margin: 4px 0 20px;\"\u003e16A–32A PEDS isolators support 2–12 poles (levels) per unit. With jumpers, ratings up to 58A \/ 1500V are achievable. Current ratings above for single-phase 230V inverter AC output and assume 1:1 DC\/AC ratio sizing. Always match to or above the inverter manufacturer's recommended DC isolator rating.\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eHow to Size a DC Isolator for Your Inverter\u003c\/div\u003e\n\u003cdiv style=\"background: #e6f4f3; border-radius: 8px; padding: 18px 20px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"font-size: 15px; color: #005c54; font-weight: bold; margin-bottom: 10px;\"\u003eThree selection criteria\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #333; line-height: 1.8;\"\u003e\n\u003cstrong\u003e1. Voltage:\u003c\/strong\u003e The isolator rated voltage must be ≥ the system open-circuit voltage (Voc). For most residential single-phase string inverters: Voc is typically 300–800V. The PEDS 1500V rating covers all current residential and C\u0026amp;I systems with margin to spare.\u003cbr\u003e\u003cstrong\u003e2. Current:\u003c\/strong\u003e Select at or above the string short-circuit current (Isc) × 1.25 (IEC safety factor). For modern 400–600 Wp panels with Isc ≈14A: 14 × 1.25 = 17.5A → use 25A. For higher-current panels (Isc up to 20A): 20 × 1.25 = 25A → use 32A.\u003cbr\u003e\u003cstrong\u003e3. Poles:\u003c\/strong\u003e 2-pole (2P) for single-string \/ single-MPPT inverters. 4-pole (4P) for dual-MPPT or dual-string inverters (most modern 3.6–8 kW residential inverters). Check the inverter datasheet for MPPT count.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eBS 7671 Required DC Isolation at Every String Inverter\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eBS 7671 (18th Edition) requires a \u003cstrong\u003emeans of isolation on the DC side\u003c\/strong\u003e of every grid-connected PV installation, in addition to the inverter’s internal DC switch. An isolator-disconnector rated to IEC\/EN 60947-3 is the correct device type. The PEDS series is specifically rated and certified for this purpose as a \u003cstrong\u003ePV DC isolator-disconnector\u003c\/strong\u003e, providing the legally required means of safe DC isolation for inverter maintenance or emergency shutdown.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eBS 7671 \/ IEC 60947-3\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003ePV DC isolation\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eLegal compliance\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e1500V DC Rated — Future-Proof for All Current and Emerging Systems\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe PEDS series is rated to \u003cstrong\u003e1500V DC\u003c\/strong\u003e — the highest system voltage used in current commercial PV installations and well above the voltage of any residential string. Typical residential strings (10–20 panels at 30–40V Voc each) produce open-circuit voltages of 300–800V DC. A 1500V-rated isolator provides a \u003cstrong\u003esubstantial insulation safety margin\u003c\/strong\u003e above the working voltage and ensures the isolator will not break down or track internally even under transient overvoltage conditions.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e1500V DC rated\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eResidential: 300–800V typical\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eFull insulation margin\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eEnergy-Storage Spring Mechanism — 5ms Arc Quench\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe PEDS uses an \u003cstrong\u003eenergy-storage spring mechanism\u003c\/strong\u003e to drive contacts apart. When the handle is turned to OFF, the spring releases and separates the contacts in under \u003cstrong\u003e5 milliseconds\u003c\/strong\u003e, regardless of how slowly the operator turns the handle. This is critical for DC isolation: unlike AC, DC current has no zero-crossing, so if contacts separate slowly the arc will sustain and cause contact erosion, heat and fire risk. The 5ms spring-driven separation ensures the arc is quenched before it can stabilise.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e5ms spring mechanism\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eDC arc quench\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eHandle-speed independent\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eDual Arc-Suppression: Magnetic + Gate Extinguishing\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eEach pole uses \u003cstrong\u003eboth magnetic arc extinguishing and gate arc extinguishing\u003c\/strong\u003e in combination. Magnetic arc extinguishing moves the arc into the extinguishing chamber rapidly; gate extinguishing divides and cools the arc within the chamber. The two mechanisms working together provide reliable arc quenching across the full rated voltage and current range, maintaining the short arcing distance needed to prevent contact damage over the isolator’s life.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eMagnetic arc extinguishing\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eGate arc extinguishing\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eShort arcing distance\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eSelf-Cleaning Contacts — Low Resistance Over Full Service Life\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe contact surfaces have a \u003cstrong\u003eself-cleaning wiping action\u003c\/strong\u003e on each operation. This removes the thin oxide layer that forms on metal contacts exposed to air, preventing the gradual increase in contact resistance that would otherwise cause voltage drop, heating and energy loss at the isolator. In PV systems where the isolator may see maximum current during peak generation periods, maintaining low contact resistance is important for both efficiency and thermal safety.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eSelf-cleaning contacts\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eLow contact resistance\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eStable over life\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eIP66 Enclosure — Three-Position Lockable Handle\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe PEDS-EL standalone enclosure carries an \u003cstrong\u003eIP66 weatherproof rating\u003c\/strong\u003e — fully dustproof and protected against high-pressure water jets. Suitable for outdoor mounting, roof structures, loft spaces and exposed plant rooms. The rotary handle has \u003cstrong\u003ethree lockable positions\u003c\/strong\u003e: ON, OFF and a third intermediate position to prevent misoperation. The handle can be locked in the OFF position with a padlock for safe isolation during maintenance, satisfying Electricity at Work Regulations 1989 requirements.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eIP66\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e3-position lockable\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003ePadlock-compatible OFF\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eOutdoor-rated\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e−40°C to +70°C Operating Range — Full Load in Extreme Conditions\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe PEDS is rated for full-load operation from \u003cstrong\u003e−40°C to +70°C\u003c\/strong\u003e. The enclosure is manufactured from \u003cstrong\u003eItalian-import UL 94 V-0 flame-retardant material\u003c\/strong\u003e that will not deform below 300°C, significantly outperforming standard domestic-grade plastics that begin to deform around 245°C. This matters on south-facing roof installations in summer where enclosures can reach high temperatures from solar heating.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e−40 to +70°C\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eUL 94 V-0 material\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e300°C deformation point\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eWorld’s First Isolator to Pass IEC 60947-3 (ed.3.2):2015 — Full Certification Stack\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eProjoy was the \u003cstrong\u003efirst company in China to pass IEC 60947-3 (ed.3.2):2015\u003c\/strong\u003e — the updated DC isolator standard which added critical current testing, thermal cycling, moisture resistance tests and higher pulse voltage requirements compared to the previous edition. The PEDS series carries \u003cstrong\u003eTUV, CE, CB, SAA, UL and UKCA certifications\u003c\/strong\u003e. UKCA certification (obtained November 2022) covers the full PEDS, PEDSH and PEDSC range, confirming compliance with UK market access requirements post-Brexit.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eIEC 60947-3 ed.3.2:2015\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eTUV + CE + CB + SAA + UL\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eUKCA certified\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eUK-market compliant\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eSingle-Channel Contact Design for 40–55A — Better Stability than Stacked Poles\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eFor the higher-current PEDS variants (40A and 55A), Projoy uses a \u003cstrong\u003esingle-channel two-stage contact design\u003c\/strong\u003e to reach 1500V \/ 40–55A, rather than stacking 3–4 separate poles in series as most competitors do. Stacked-pole designs require all contacts to switch with precisely equal timing and gap; manufacturing variation means they rarely do, reducing actual breaking performance. The single-channel design is more consistent and more stable, and is the only Chinese DC isolator product to hold TUV certificates for 40A and 55A ratings individually.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eSingle-channel 40–55A\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eBetter than stacked poles\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eOnly Chinese 40A\/55A TUV cert\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 24px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: 'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eElectrical Ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMax DC Voltage (Ue)\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e1500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eCurrent Ratings Available\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e16A, 25A, 32A (standard range); 40A, 55A (PEDS150H high-current series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePoles Available\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e2P, 4P (standard); up to 12 poles with jumpers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eStrings\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e1 string (2P), 2 strings (4P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMax Rating with Jumpers\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e58A \/ 1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eMechanism and Performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eSwitching Speed\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e\u0026lt;5ms (energy-storage spring, handle-speed independent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eArc Suppression\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eMagnetic arc extinguishing + gate arc extinguishing (dual system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eContact Design\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eSelf-cleaning wiping contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eContact Design (40–55A)\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eSingle-channel two-stage (not stacked poles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003ePhysical and Environmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eIP Rating (Enclosure Series)\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eIP66 (dustproof, high-pressure water-jet proof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eFlame Retardant — Body\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eUL 94 V-0 (Italian-import material, deformation point \u0026gt;300°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eFlame Retardant — Handle\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eUL 94 V-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e−40°C to +70°C (full load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eHandle Positions\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e3 positions: ON \/ intermediate \/ OFF (lockable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eLockable\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eYes — padlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eMounting Options (PEDS Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eEnclosure (PEDS-EL)\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eIP66 standalone enclosure, wall-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eSingle-Hole Mount (PEDS-HM)\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003ePanel or enclosure back-plate, single hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePanel Mount (PEDS-PM)\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eBolted to panel surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eDIN Rail \/ Distribution Board\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eSnap-fit to 35mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eDoor Clutch\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eHandle on door, mechanism to chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eStandards and Certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePrimary Standard\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eIEC\/EN 60947-3:2009+A1+A2 (ed.3.2:2015 for 40–55A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eAdditional Standards\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eAS 60947.3, UL508i, GB\/T14048.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eTUV, CE, CB, SAA, UL, UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eUKCA Coverage\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eFull PEDS, PEDSH and PEDSC series — UK market compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eISO\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eISO 9001 (quality), ISO 14001 (environmental)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eManufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eProjoy Electric Co., Ltd.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eLocation\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eSuzhou, China (founded 2011)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMarket Position\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eUsed by the majority of China’s mainstream PV inverter manufacturers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eDo I need a DC isolator if my inverter already has a built-in DC switch?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eYes. The inverter’s internal DC switch isolates the inverter from the PV cables — but it is inside the inverter enclosure and is not designed to be the primary means of external isolation for maintenance work. \u003cstrong\u003eBS 7671 (18th Edition) requires an externally accessible means of isolation\u003c\/strong\u003e on the DC side of every grid-connected PV system, rated as an isolator-disconnector to IEC\/EN 60947-3. The PEDS fulfils this requirement. It should be mounted close to the inverter, clearly labelled as a PV DC isolator, and accessible without opening the inverter.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhat is the difference between an isolator and a circuit breaker?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eA \u003cstrong\u003eDC isolator\u003c\/strong\u003e (isolator-disconnector) is designed to disconnect a de-energised or lightly loaded circuit safely. It provides a visible, lockable means of isolation so that maintenance can be carried out safely, but it is not designed to interrupt sustained fault current. A \u003cstrong\u003eDC MCB or circuit breaker\u003c\/strong\u003e (such as the Projoy PEBS-L or PEBS-H) is designed to interrupt overload and short-circuit fault current automatically. For a PV installation, you typically need \u003cem\u003eboth\u003c\/em\u003e: an isolator for safe manual isolation and a circuit breaker or fuse for overcurrent protection of the DC cable.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eHow do I select the right current rating?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eMultiply the panel string short-circuit current (Isc, from the panel datasheet) by 1.25 (the IEC safety factor for PV). Example: panels with Isc = 12A → 12 × 1.25 = 15A → use a 16A isolator. For panels with Isc = 14A: 14 × 1.25 = 17.5A → use 25A. Always check the inverter manufacturer’s documentation for their recommended DC isolator current rating for the specific inverter model.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eShould I use 2-pole or 4-pole?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eUse \u003cstrong\u003e2-pole (2P)\u003c\/strong\u003e for single-string \/ single-MPPT inverters (one string of panels). Use \u003cstrong\u003e4-pole (4P)\u003c\/strong\u003e for dual-MPPT inverters with two independent strings. Most modern residential string inverters from 3–8 kW have two MPPTs and require a 4-pole isolator. Check the inverter datasheet for MPPT count and the number of DC input pairs.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eIs the PEDS suitable for use in the UK after Brexit?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eYes. Projoy obtained \u003cstrong\u003eUKCA certification for the full PEDS, PEDSH and PEDSC series\u003c\/strong\u003e in November 2022. UKCA is the UK conformity assessed mark that replaced CE marking for products placed on the UK market (England, Wales, Scotland) after 1 January 2023. The PEDS carries both CE and UKCA marks, confirming compliance with UK market access requirements.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eRelated Products\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(220px,1fr)); gap: 10px; margin-bottom: 10px;\"\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eProjoy PEAS AC Isolator (20–40A)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eAC-side isolation at the inverter output — also required by BS 7671\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eProjoy PEFS-EL Firefighter Safety Switch\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eString-level rapid shutdown — disconnects panels from inverter DC run\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eProjoy Battery Isolator PEBS-L with Enclosure\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eDC MCB for battery–inverter circuit protection\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eProjoy DC Surge Protector (PESP)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eSurge protection device for DC PV string circuits\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Projoy Electric","offers":[{"title":"25A 2pole 1string","offer_id":62614259138909,"sku":"PEDS150-EL25R-2","price":17.95,"currency_code":"GBP","in_stock":true},{"title":"32A 4pole 2string","offer_id":62614259171677,"sku":"PEDS150-EL32R-4","price":18.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/ProjoyDCIsolator25A2pole1string.jpg?v=1763448346"},{"product_id":"projoy-battery-isolators-with-enclosure","title":"Projoy PEBS-L Battery Isolator with Enclosure – DC MCB 80A\/100A\/125A 160V, IP66, IEC\/EN 60947-2, Solar BESS Battery-Inverter Protection","description":"\u003c!-- SEO Product Name: Projoy PEBS-L Battery Isolator with Enclosure – DC MCB 80A\/100A\/125A 160V, IP66, IEC\/EN 60947-2, Solar BESS Battery-Inverter Protection --\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003eThe \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003eProjoy PEBS-L Series Battery Isolator\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e is a \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003epurpose-built DC miniature circuit breaker (MCB)\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e designed to protect the cable and circuit between a battery energy storage system (BESS) and a hybrid inverter. Unlike standard AC MCBs — which \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003emust never be used on DC circuits\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e due to the risk of sustained arcing — the PEBS-L uses a dedicated \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003eDC arc extinguishing and flash barrier technology\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e to interrupt fault current safely. Rated to \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e160V DC and available in 80A, 100A and 125A\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e, with a \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e10 kA short-circuit breaking capacity (Icu)\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e, it covers the full range of residential and light-commercial BESS applications including LFP (lithium iron phosphate), NMC and other 48V or higher-voltage DC battery systems. Tested and certified to \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003eIEC\/EN 60947-2 and GB\/T 14048.2\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e. Available as a bare MCB for panel integration, or in an \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003eIP65\/IP66 flame-retardant polycarbonate enclosure\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e with screwed or hinged lid for standalone wall-mount installation indoors or outdoors. Also available: a \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003estandalone empty IP66 enclosure\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e (4-module capacity) for custom wiring configurations. Manufactured by Projoy Electric Co., Ltd. — \u003c\/span\u003e\u003cstrong style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003eISO 9001 and ISO 14001 certified\u003c\/strong\u003e\u003cspan style=\"color: rgb(51, 51, 51); font-size: 16px; background-color: rgb(255, 255, 255); font-family: 'Segoe UI', Helvetica, Arial, sans-serif;\"\u003e specialist DC safety component manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; font-family: 'Segoe UI',Helvetica,Arial,sans-serif; color: #222; background: #fff; max-width: 900px; line-height: 1.5;\"\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(130px,1fr)); gap: 10px; margin-bottom: 24px;\"\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003e160V DC\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eMax Voltage\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003e125A\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eMax Current\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003e10 kA\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eBreaking Capacity\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003eIP66\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eEnclosure Rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003eIEC\/EN 60947-2\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: .85; margin-top: 4px;\"\u003eStandard\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #fff8e1; border-left: 4px solid #f0a500; border-radius: 0 8px 8px 0; padding: 14px 18px; margin: 6px 0 16px; font-size: 15px; color: #5a4000;\"\u003e\n\u003cstrong\u003e⚠ DC Circuits: Use Only DC-Rated Devices\u003c\/strong\u003e Standard AC MCBs are \u003cstrong\u003enot safe for battery or DC PV circuits\u003c\/strong\u003e. DC arcs do not self-extinguish and can cause fire or fatal injury if an AC breaker is used. Always use a device rated and certified for DC use at the appropriate voltage and current. Installation must be carried out by a \u003cstrong\u003equalified electrician\u003c\/strong\u003e to BS 7671.\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eRange Overview — Which Variant Do You Need?\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 24px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: 'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #008377; color: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003eRating\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 11px; font-weight: bold; font-size: 13px;\"\u003eTypical Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f9f8;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePEBS-L-80A-160V-2P‑DC\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e80A \/ 160V DC\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e2P (MCB only)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eNo enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePanel-mount or add to own enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePEBS-L-100A-160V-2P‑DC\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e100A \/ 160V DC\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e2P (MCB only)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eNo enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePanel-mount or add to own enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f9f8;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePEBS-L-125A-160V-2P‑DC\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e125A \/ 160V DC\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e2P (MCB only)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eNo enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePanel-mount or add to own enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePEBS-L-80A-160V-2PL‑ENCL\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e80A \/ 160V DC\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e2-pole MCB + IP66 enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eIP66 weatherproof\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eBattery–inverter connection, indoor or outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f9f8;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePEBS-L-100A-160V-2PL‑ENCL\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e100A \/ 160V DC\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e2-pole MCB + IP66 enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eIP66 weatherproof\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eBattery–inverter connection, indoor or outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePEBS-L-125A-160V-2PL‑ENCL\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e125A \/ 160V DC\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e2-pole MCB + IP66 enclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eIP66 weatherproof\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eHigh-current battery–inverter, 125A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f9f8;\"\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003ePEBS-L-IP66-4P‑ENCLOSURE\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eN\/A (empty enclosure)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e4-module capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eIP66 weatherproof\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 11px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eSpare or custom wiring enclosure for 2×MCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #666; margin: -12px 0 20px;\"\u003eFor most residential BESS installations with a 48V battery system: the \u003cstrong\u003e80A or 100A 160V variant\u003c\/strong\u003e is typical. 125A is required for high-capacity systems or larger inverters drawing sustained high current. Always size to the battery manufacturer's recommended fuse or breaker rating for the specific system.\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003ePEBS-L Series DC MCB — Designed Specifically for Battery–Inverter Circuits\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eStandard AC miniature circuit breakers \u003cstrong\u003ecannot safely interrupt DC current\u003c\/strong\u003e. DC arcs do not self-extinguish at the zero-crossing point the way AC arcs do — they are sustained, hotter and far more likely to cause damage or fire if an AC MCB is used on a DC circuit. The Projoy PEBS-L is \u003cstrong\u003epurpose-designed for DC applications\u003c\/strong\u003e, using a dedicated arc extinguishing and flash barrier chamber that quenches the DC arc reliably at rated interrupting capacity. It is \u003cstrong\u003etested and certified to IEC\/EN 60947-2 and GB\/T 14048.2\u003c\/strong\u003e specifically for DC use.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003ePurpose-built DC MCB\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eIEC\/EN 60947-2 certified\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eNot an AC MCB\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e10 kA Short-Circuit Breaking Capacity (Icu) — Handles Real-World Fault Currents\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe PEBS-L is rated at \u003cstrong\u003eIcu 10 kA\u003c\/strong\u003e — the maximum prospective short-circuit current it can safely interrupt without damage to the device, installation or personnel. Battery systems, particularly lithium-based BESS, can deliver extremely high fault currents because the internal impedance of a healthy battery is very low. A 10 kA breaking capacity provides a substantial safety margin for residential and light commercial BESS installations where prospective fault currents are typically well below this level.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e10 kA Icu\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eBattery fault protection\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eHigh-current BESS safe\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eNon-Polarity Design — Flexible Wiring in Either Direction\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe PEBS-L is \u003cstrong\u003enon-polarity sensitive\u003c\/strong\u003e — the positive and negative DC terminals can be connected to either the line or load side without affecting performance or safety. This simplifies installation, reduces the chance of wiring errors, and gives installers flexibility when routing cables in the battery enclosure or consumer unit.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eNon-polarity\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eEither terminal can be L or N\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eReduces wiring errors\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eIP65\/IP66 Weatherproof Enclosure — Indoor and Outdoor Installation\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe enclosure variants ship with a \u003cstrong\u003epolycarbonate IP66-rated weatherproof enclosure\u003c\/strong\u003e that is fully dustproof and protected against powerful water jets from any direction. This makes them suitable for battery installations in garages, outbuildings, meter cupboards, loft spaces and outdoor weatherproof enclosures alike. The enclosure is \u003cstrong\u003eflame-retardant polycarbonate\u003c\/strong\u003e — it will not propagate fire even in the event of a sustained arc or external flame exposure.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eIP65\/IP66\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eFlame-retardant polycarbonate\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eOutdoor-rated\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eScrewed or Hinged Lid — Fast Commissioning and Future Access\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eEnclosure variants are available with either a \u003cstrong\u003escrewed lid\u003c\/strong\u003e (fully sealed, tamper-resistant) or \u003cstrong\u003ehinged lid\u003c\/strong\u003e (fast access for commissioning, inspection and maintenance). Both styles provide the same IP66 rating when correctly closed. Knockout cable entry points are provided on multiple faces to accommodate different cable run directions without additional drilling.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eScrewed or hinged lid options\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eMultiple cable knockouts\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eIP66 both styles\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e160V DC Maximum Rated Voltage — Correct for LFP and Other 48V Battery Systems\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe PEBS-L is rated to \u003cstrong\u003e160V DC maximum\u003c\/strong\u003e. A typical 48V nominal lithium iron phosphate (LFP) BESS has a maximum charge voltage of approximately 58–60V. The 160V rating is deliberately conservative to accommodate \u003cstrong\u003ehigher-voltage battery configurations\u003c\/strong\u003e such as stacked 48V packs or 96V\/120V nominal systems, where the fully-charged open-circuit voltage can approach or exceed 120V DC. It also provides a significant safety margin above the working voltage for any single 48V system.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e160V DC rated\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e48V to ~120V systems\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eVoltage safety margin\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eOverload and Short-Circuit Protection — Two Functions in One Device\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe PEBS-L provides both \u003cstrong\u003eoverload protection\u003c\/strong\u003e (bimetallic thermal trip — trips when current exceeds rated value for a sustained period) and \u003cstrong\u003eshort-circuit protection\u003c\/strong\u003e (magnetic instantaneous trip — trips within milliseconds when a hard fault occurs). This replaces the combination of a fuse plus separate isolator that older battery installations sometimes use, and provides automatic re-settable protection rather than a one-shot fuse that must be replaced after a fault.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eOverload + short-circuit protection\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eBimetallic + magnetic trip\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eRe-settable\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"15\" height=\"15\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eISO 9001 and ISO 14001 Certified Manufacturer — Quality Assured\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eProjoy Electric Co., Ltd. holds \u003cstrong\u003eISO 9001 quality management\u003c\/strong\u003e and \u003cstrong\u003eISO 14001 environmental management\u003c\/strong\u003e system certifications. All PEBS-L circuit breakers undergo rigorous environmental and electrical testing, including temperature cycling, vibration, humidity and dielectric strength tests, before release. Projoy is a specialist solar and energy storage electrical component manufacturer with dedicated design, production and test facilities in Suzhou, China.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eISO 9001\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eISO 14001\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eDedicated BESS specialist\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 24px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: 'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eMCB Electrical Ratings (PEBS-L Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eRated Voltage (Ue)\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e160V DC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eAvailable Current Ratings (In)\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e80A \/ 100A \/ 125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eRated Short-Circuit Breaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eProtection Functions\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eOverload (thermal) and short circuit (magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e2P (two-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePolarity\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eNon-polarity — line and load can be on either terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eApplications\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003ePV systems, battery energy storage systems (BESS), DC distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eTypical Position in System\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eBetween battery and hybrid inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eCertifications and Standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eTest Standard\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eIEC\/EN 60947-2 and GB\/T 14048.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eQuality System\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eISO 9001 (quality management)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eEnvironmental System\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eISO 14001 (environmental management)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eNote\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eNot to be used as a switch under load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eEnclosure (Enclosure Variants)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eFlame-retardant polycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eEnclosure IP Rating\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eIP65\/IP66 (dust-tight, water-jet proof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eLid Type\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eScrewed or hinged (variant-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eCable Entry\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eMultiple knockout entries on various faces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eWall-mount, indoor or outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eEnvironment\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eSuitable for indoor and exposed outdoor locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eAvailable SKUs at a Glance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMCB-only (no enclosure)\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e80A, 100A, 125A — 2P DC MCB bare unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMCB + enclosure\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e80A, 100A, 125A — 2P MCB in IP66 polycarbonate enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eEmpty enclosure only\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003ePEBS-L-IP66-4P-ENCLOSURE — 4-module capacity weatherproof enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eManufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eProjoy Electric Co., Ltd.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eWebsite\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eprojoy-electric.com\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eCan I use a standard AC MCB as a battery isolator?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eNo. \u003cstrong\u003eStandard AC MCBs must not be used on DC circuits.\u003c\/strong\u003e AC circuit breakers rely on the natural zero-crossing of alternating current to extinguish the arc when they trip. DC current has no zero-crossing — the arc is sustained and significantly hotter. Using an AC MCB on a battery circuit creates a serious fire and electrocution risk. The Projoy PEBS-L is purpose-designed with a dedicated DC arc extinguishing chamber and is certified to IEC\/EN 60947-2 specifically for DC applications.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhich current rating (80A, 100A or 125A) do I need?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eSize to the maximum continuous DC current the battery system can deliver to the inverter — typically found in the battery manufacturer's datasheet as the maximum discharge current. As a rule of thumb for common UK residential BESS: a 3.6–7.2 kWh LFP battery with a 48V nominal bus will typically draw 50–80A at maximum inverter load. \u003cstrong\u003e80A\u003c\/strong\u003e is suitable for most systems up to ~4 kW inverter output; \u003cstrong\u003e100A\u003c\/strong\u003e for systems up to ~5 kW; \u003cstrong\u003e125A\u003c\/strong\u003e for high-capacity or multi-battery systems. Always verify against the battery manufacturer’s recommended breaker\/fuse rating.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eDo I need the enclosure version, or can I buy just the MCB?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eIf you are installing into an existing DIN-rail consumer unit or combiner box that already provides appropriate IP rating and enclosure, the bare MCB (no enclosure) version is sufficient. If the battery isolator will be mounted in a separate location — such as a garage wall, loft, outbuilding or outside the main consumer unit — choose the \u003cstrong\u003eenclosure version\u003c\/strong\u003e for IP65\/IP66 protection and flame-retardant housing.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eIs this suitable for LFP (lithium iron phosphate) battery systems like SolaX, myenergi libbi, or similar?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eYes. The PEBS-L is rated to \u003cstrong\u003e160V DC\u003c\/strong\u003e, which comfortably covers 48V nominal LFP systems (fully charged open-circuit voltage typically 54–58V for a single pack). It is also suitable for stacked or higher-voltage configurations up to 160V DC. Always check the specific battery inverter manufacturer's installation guidance for the required isolator rating at the battery terminals.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eCan it be used as a switch to turn the battery off under load?\u003c\/span\u003e\u003csvg width=\"18\" height=\"18\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003e\n\u003cstrong\u003eNo.\u003c\/strong\u003e The PEBS-L is a \u003cem\u003ecircuit breaker\u003c\/em\u003e, not a load-break switch. It is designed to trip automatically under fault conditions, or to be operated manually only when the circuit is de-energised. Operating it as a routine on\/off switch while current is flowing will cause contact wear, arcing and premature failure. For routine battery isolation with load present, use a dedicated DC load-break isolator switch.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eRelated Products\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(220px,1fr)); gap: 10px; margin-bottom: 10px;\"\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eProjoy DC Surge Protection Device (SPD)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eSurge protection for PV and battery DC circuits\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eSolaX X3-Hybrid Inverter\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eCompatible hybrid inverter for BESS installations\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003emyenergi libbi Battery Storage\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eCompatible home battery system requiring DC isolation\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eSolar iBoost+ Solar Diverter\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003ePV diverter for solar-to-immersion applications\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Projoy Electric","offers":[{"title":"2 Pole Battery Isolator 125A 160V DC with Enclosure","offer_id":62614957424989,"sku":"PEBS-L-125A-160V-2PL-KIT","price":39.0,"currency_code":"GBP","in_stock":true},{"title":"2 Pole Battery Isolator 100A 160V DC with Enclosure","offer_id":62614957392221,"sku":"PEBS-L-100A-160V-2PL-KIT","price":39.0,"currency_code":"GBP","in_stock":true},{"title":"2 Pole Battery Isolator 80A 160V DC with Enclosure","offer_id":62614957556061,"sku":"PEBS-L-80A-160V-2PL-KIT","price":39.0,"currency_code":"GBP","in_stock":true},{"title":"Battery Isolator 160V 125A DC MCB","offer_id":62614957490525,"sku":"PEBS-L-160V-125A-2P","price":19.0,"currency_code":"GBP","in_stock":true},{"title":"Battery Isolator 160V 100A DC MCB","offer_id":62614957457757,"sku":"PEBS-L-160V-100A-2P","price":19.0,"currency_code":"GBP","in_stock":true},{"title":"Battery Isolator 160V 80A DC MCB","offer_id":62614957523293,"sku":"PEBS-L-160V-80A-2P","price":19.0,"currency_code":"GBP","in_stock":true},{"title":"DC MCB Weatherproof Empty Enclosure","offer_id":62614957588829,"sku":"PEBS-L-IP66-4P-ENCL","price":20.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Projoy_2_Pole_Battery_Isolator_125A_160V_DC_with_Enclosure.jpg?v=1763449652"},{"product_id":"santon-2-pole-and-4-pole-dc-isolators","title":"Santon 2 Pole and 4 Pole DC Isolators","description":"\u003ch2\u003eSanton 2 Pole and 4 Pole DC Isolators\u003c\/h2\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Voltage Ratings:\u003c\/strong\u003e Suitable for DC voltages up to 1000V\/850V (2 Pole) and 1000V\/750V (4 Pole), ideal for solar and battery systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Currents:\u003c\/strong\u003e Supports 16A continuous current with 25A peak capability for safe circuit isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Design:\u003c\/strong\u003e IP65 rated enclosures provide weatherproof and dustproof protection for harsh outdoor environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePadlockable Switch Knob:\u003c\/strong\u003e Enhances operational safety by allowing secure isolation during maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Compact footprint with simple wiring terminals supports up to 10 mm² cable size.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Switch Mechanism:\u003c\/strong\u003e Snap action mechanism ensures quick and positive switching, minimising arcing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Variants\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003cth\u003eCurrent (A)\u003c\/th\u003e\n\u003cth\u003eVoltage DC (V)\u003c\/th\u003e\n\u003cth\u003eCable Size (mm²)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSAN-D1-G1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSanton 2 Pole DC Isolator\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e16A Continuous \/ 25A Peak\u003c\/td\u003e\n\u003ctd\u003e1000V \/ 850V\u003c\/td\u003e\n\u003ctd\u003e10mm² max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSAN-D14-G1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSanton 4 Pole DC Isolator\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e16A Continuous \/ 25A Peak\u003c\/td\u003e\n\u003ctd\u003e1000V \/ 750V\u003c\/td\u003e\n\u003ctd\u003e10mm² max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhy Choose Santon DC Isolators?\u003c\/h3\u003e\n\u003cp\u003eSanton DC Isolators are engineered to provide secure and reliable disconnection for solar photovoltaic and battery energy storage systems. Their high voltage and current ratings, combined with robust weatherproof enclosures, make them an excellent choice for both residential and commercial renewable energy installations. The padlockable switch knob ensures maintenance safety, while quick snap-action switching minimises downtime and wear.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDurable for outdoor use in harsh environments.\u003c\/li\u003e\n\u003cli\u003eClear ON\/OFF visual indication improves safety and operation clarity.\u003c\/li\u003e\n\u003cli\u003eComplies with relevant electrical safety and installation standards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Santon","offers":[{"title":"2 Pole 16A 1000V\/25A 850V DC Isolator","offer_id":62615332651357,"sku":"SAN-D1-G1","price":97.0,"currency_code":"GBP","in_stock":true},{"title":"4 Pole 16A 1000V\/25A 750V DC Isolator","offer_id":62615332684125,"sku":"SAN-D14-G1","price":95.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Santon2Pole16A1000V25A850VDCIsolator.jpg?v=1769507471"},{"product_id":"europa-lb324p-rotary-isolator-switch-32a-4-pole","title":"Europa LB324P Rotary Isolator Switch 32A 4 Pole","description":"\u003cp\u003eThe Europa LB324P Rotary Isolator Switch is a highly reliable and robust solution for isolating power in industrial, commercial, and light manufacturing environments. Featuring a 32A 4 pole design, this enclosed AC isolator provides safety, flexibility, and long-term performance for a wide range of electrical installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 32A for dependable circuit isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e 4 Pole—ideal for three-phase and neutral supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e Up to 690V AC, suitable for a variety of electrical systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeatherproof Enclosure:\u003c\/strong\u003e IP65 polycarbonate case offers dust and moisture protection for outdoor and industrial use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePadlockable Handle:\u003c\/strong\u003e Allows secure isolation with lock-off facility in the OFF position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame Retardant \u0026amp; UV Resistant:\u003c\/strong\u003e Case manufactured from high-grade material for increased durability and safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterlocked Lid:\u003c\/strong\u003e Improves safety by preventing enclosure removal in the ON position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Cable Entry:\u003c\/strong\u003e 20mm knockouts for easy wiring and installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e 125 x 100 x 74mm enclosure fits most industrial panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e EN 60947 \/ UL \/ CSA approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEUR-LB324P\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropa Rotary Isolator Switch\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e690V AC\u003c\/td\u003e\n\u003ctd\u003eIP65, polycarbonate, flame retardant \u0026amp; UV resistant\u003c\/td\u003e\n\u003ctd\u003e125 x 100 x 74mm\u003c\/td\u003e\n\u003ctd\u003eEN 60947 \/ UL \/ CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhy Choose Europa LB324P?\u003c\/h3\u003e\n\u003cp\u003eThe Europa LB324P rotary isolator switch is trusted by installers for its robust construction, superior ingress protection, and user safety features. With a padlockable handle, interlocked lid, and flexible mounting options, this isolator ensures quick, hassle-free installation and peace of mind when isolating critical equipment. It’s the smart choice for demanding environments calling for reliability and security.\u003c\/p\u003e","brand":"Europa Components","offers":[{"title":"Default Title","offer_id":62615576052061,"sku":"EUR-LB324P","price":35.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/EuropaLB324PRotaryIsolatorSwitch32A4Pole.png?v=1763451549"},{"product_id":"solar-cable-4mm-single-core-dc-cable-100m-brown","title":"Solar Cable 4mm² Single-Core DC Cable - 100m, Brown","description":"\u003ch2\u003e4mm² Single-Core DC Solar Cable 100m - Brown\u003c\/h2\u003e\n\u003cp\u003eThis high-quality 4mm² single-core DC solar cable is specifically designed for reliable and efficient connection in solar photovoltaic systems. With a length of 100 metres, this brown cable is suitable for positive DC connections in solar arrays, providing safety, durability, and excellent electrical performance.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Size:\u003c\/strong\u003e 4mm² cross-sectional area for optimal current capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCore Type:\u003c\/strong\u003e Single core, ideal for DC positive or negative wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 100 metres—ample for solar installations of various sizes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour:\u003c\/strong\u003e Brown, commonly used for positive DC conductors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUv \u0026amp; Weather Resistance:\u003c\/strong\u003e Designed for outdoor solar use with durable insulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexibility:\u003c\/strong\u003e Maintains pliability for easy handling and installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets relevant solar cable standards ensuring safety and efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 12.9422%;\"\u003ePart Number\u003c\/th\u003e\n\u003cth style=\"width: 16.488%;\"\u003eDescription\u003c\/th\u003e\n\u003cth style=\"width: 9.57367%;\"\u003eCable Size\u003c\/th\u003e\n\u003cth style=\"width: 9.75096%;\"\u003eCore Type\u003c\/th\u003e\n\u003cth style=\"width: 11.1693%;\"\u003eLength\u003c\/th\u003e\n\u003cth style=\"width: 10.8147%;\"\u003eColour\u003c\/th\u003e\n\u003cth style=\"width: 14.8924%;\"\u003eVoltage Rating\u003c\/th\u003e\n\u003cth style=\"width: 14.7151%;\"\u003eStandards\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 12.9422%;\"\u003e\u003cstrong\u003eCABLE4-1-100-Brown\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.488%;\"\u003e4mm² Single-Core DC Solar Cable - Brown\u003c\/td\u003e\n\u003ctd style=\"width: 9.57367%;\"\u003e4mm²\u003c\/td\u003e\n\u003ctd style=\"width: 9.75096%;\"\u003eSingle Core\u003c\/td\u003e\n\u003ctd style=\"width: 11.1693%;\"\u003e100m\u003c\/td\u003e\n\u003ctd style=\"width: 10.8147%;\"\u003eBrown\u003c\/td\u003e\n\u003ctd style=\"width: 14.8924%;\"\u003e600\/1000V DC\u003c\/td\u003e\n\u003ctd style=\"width: 14.7151%;\"\u003eSolar cable standards (e.g. IEC 62852)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Cableworld","offers":[{"title":"Default Title","offer_id":62616075632989,"sku":"CABLE4-1-100-Brown","price":95.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SolarCable4mm_Single-CoreDCCable-100m_brown.webp?v=1763454003"},{"product_id":"solar-cable-4mm-single-core-dc-cable-100m-grey","title":"Solar Cable 4mm² Single-Core DC Cable - 100m Grey","description":"\u003ch2\u003e4mm² Single-Core DC Solar Cable 100m - Grey\u003c\/h2\u003e\n\u003cp\u003eThis high-quality 4mm² single-core DC solar cable is specifically designed for reliable and efficient connection in solar photovoltaic systems. With a length of 100 metres, this grey cable is suitable for positive DC connections in solar arrays, providing safety, durability, and excellent electrical performance.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Size:\u003c\/strong\u003e 4mm² cross-sectional area for optimal current capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCore Type:\u003c\/strong\u003e Single core, ideal for DC positive or negative wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 100 metres—ample for solar installations of various sizes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour:\u003c\/strong\u003e Grey, commonly used for positive DC conductors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUv \u0026amp; Weather Resistance:\u003c\/strong\u003e Designed for outdoor solar use with durable insulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexibility:\u003c\/strong\u003e Maintains pliability for easy handling and installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets relevant solar cable standards ensuring safety and efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eCable Size\u003c\/th\u003e\n\u003cth\u003eCore Type\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eColour\u003c\/th\u003e\n\u003cth\u003eVoltage Rating\u003c\/th\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCABLE4-1-100-Grey\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4mm² Single-Core DC Solar Cable - Grey\u003c\/td\u003e\n\u003ctd\u003e4mm²\u003c\/td\u003e\n\u003ctd\u003eSingle Core\u003c\/td\u003e\n\u003ctd\u003e100m\u003c\/td\u003e\n\u003ctd\u003eGrey\u003c\/td\u003e\n\u003ctd\u003e600\/1000V DC\u003c\/td\u003e\n\u003ctd\u003eSolar cable standards (e.g. IEC 62852)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhy Choose Our 4mm² DC Solar Cables?\u003c\/h3\u003e\n\u003cp\u003eOur 4mm² single-core DC solar cables in black, brown and grey provide dependable, long-lasting connections within your photovoltaic system. They feature weather and UV resistant insulation tailored to withstand outdoor environments and solar exposure. Choosing colour-coded cables simplifies installation and troubleshooting, helping to maintain system performance and safety. These cables are tested and compliant with international solar cable standards, ensuring confidence in your solar power project's electrical integrity.\u003c\/p\u003e","brand":"Cableworld","offers":[{"title":"Default Title","offer_id":62616543461725,"sku":"CABLE4-1-100-Grey","price":95.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/CABLE4-1-100-Grey.jpg?v=1763454213"},{"product_id":"2m-cable-pack-for-us2000b-c-us3000-us5000-up5000-battery-models","title":"2m Cable Pack for US2000B\/C, US3000, US5000, UP5000 Battery Models | 25mm2 Power Communication Cables Amphenol M8 100A","description":"\u003c!-- SEO Product Name: Pylontech 2m Cable Pack US2000B US2000C US3000 US3000C US5000 UP5000 CAB-PK-PYLON 25mm2 Power Communication Cables Amphenol M8 100A --\u003e\n\u003cdiv style=\"font-size: 16px; font-family: 'Segoe UI',Helvetica,Arial,sans-serif; color: #222; background: transparent; max-width: 900px; line-height: 1.5;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.75; color: #333; margin: 0 0 18px;\"\u003eThe \u003cstrong\u003ePylontech CAB-PK-PYLON\u003c\/strong\u003e is the official factory cable accessory kit for connecting a Pylontech US-series or UP-series battery stack to a DC disconnect switch or inverter. The UK version contains \u003cstrong\u003e4 cables in total\u003c\/strong\u003e: two 2-metre power cables (positive and negative, \u003cstrong\u003e25 mm², Amphenol → M8 ring lug\u003c\/strong\u003e) and two communication cables with RJ45 connectors, one of which is \u003cstrong\u003eblue-labelled for Solis inverter compatibility\u003c\/strong\u003e. The pack supports systems up to \u003cstrong\u003e100 A continuous charge\/discharge\u003c\/strong\u003e and is compatible with the \u003cstrong\u003eUS2000B, US2000C, US3000, US3000C, US5000 and UP5000\u003c\/strong\u003e battery models. \u003cstrong\u003eImportant:\u003c\/strong\u003e these cables are for battery-to-inverter or battery-to-DC-disconnect connection only — not for parallel battery-to-battery links. Battery-to-battery interlink cables are supplied with each Pylontech battery module.\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(110px,1fr)); gap: 10px; margin-bottom: 24px;\"\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: 800; line-height: 1.1;\"\u003e4 Cables\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003ePer pack (UK)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: 800; line-height: 1.1;\"\u003e25mm²\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003ePower cables\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: 800; line-height: 1.1;\"\u003e100A\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003eContinuous rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: 800; line-height: 1.1;\"\u003e2m\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003eCable length\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: 800; line-height: 1.1;\"\u003eAmphenol → M8\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003eTermination\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: 800; line-height: 1.1;\"\u003e6 Models\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003eCompatible\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #fff8e1; border-left: 4px solid #d97706; border-radius: 0 8px 8px 0; padding: 14px 18px; margin: 6px 0 16px; font-size: 15px; color: #92400e;\"\u003e\n\u003cstrong\u003e⚠ NOT for parallel battery-to-battery connection:\u003c\/strong\u003e This cable pack connects the \u003cstrong\u003ebattery stack to the DC disconnect switch or inverter\u003c\/strong\u003e. Cables for connecting one battery module to the next (interlink \/ parallel cables) are \u003cstrong\u003ealready included with each Pylontech battery unit\u003c\/strong\u003e. Do not use these 2m cables as battery-to-battery interlinks.\u003c\/div\u003e\n\u003cdiv style=\"background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 8px 8px 0; padding: 14px 18px; margin: 6px 0 16px; font-size: 15px; color: #005c54;\"\u003e\n\u003cstrong\u003eℹ Victron \/ CAN-bus communication:\u003c\/strong\u003e For communication with Victron Energy systems (Multiplus, Quattro, MPPT, GX devices), a separate \u003cstrong\u003eVictron VE.Can to CAN-bus BMS cable\u003c\/strong\u003e (Type A or Type B, 1.8m) is required alongside this pack. The included RJ45 communication cables are for RS485-based inverter brands. Always verify the correct pinout with your inverter’s documentation.\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eWhat’s in the Box — UK Version (4 Cables)\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(220px,1fr)); gap: 10px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"background: #f0f9f8; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #008377;\"\u003e\n\u003cdiv style=\"font-size: 14px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e1 × 2m Positive Power Cable\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444; line-height: 1.5;\"\u003e25 mm² solar-grade conductor. Amphenol quick-lock connector at battery end; M8 ring lug at inverter\/DC disconnect end. Rated 105°C insulation. Red or marked +.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f8f8f8; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #008377;\"\u003e\n\u003cdiv style=\"font-size: 14px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e1 × 2m Negative Power Cable\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444; line-height: 1.5;\"\u003e25 mm² solar-grade conductor. Amphenol quick-lock connector at battery end; M8 ring lug at inverter\/DC disconnect end. Rated 105°C insulation. Black or marked −.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0f9f8; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #008377;\"\u003e\n\u003cdiv style=\"font-size: 14px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e1 × Communication Cable (Standard)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444; line-height: 1.5;\"\u003eRJ45 to RJ45. Connects the battery BMS RS485\/CAN port to the inverter communication port. Standard labelling — for GivEnergy, SolarEdge, Growatt, Sungrow and most other RS485-based inverters.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f8f8f8; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #008377;\"\u003e\n\u003cdiv style=\"font-size: 14px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e1 × Communication Cable (Blue — Solis)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444; line-height: 1.5;\"\u003eRJ45 to RJ45, \u003cstrong\u003eblue-labelled\u003c\/strong\u003e. Specifically for \u003cstrong\u003eSolis inverters\u003c\/strong\u003e when using US-type C variant batteries. Pin-out differs from the standard comms cable. Select this cable for Solis; use the standard cable for all other brands.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eBattery Compatibility\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 24px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: 'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #008377; color: #fff;\"\u003e\n\u003cth style=\"padding: 9px 12px; text-align: left; font-size: 13px; font-weight: bold;\"\u003eBattery model\u003c\/th\u003e\n\u003cth style=\"padding: 9px 12px; text-align: left; font-size: 13px; font-weight: bold;\"\u003eCompatible\u003c\/th\u003e\n\u003cth style=\"padding: 9px 12px; text-align: left; font-size: 13px; font-weight: bold;\"\u003eCommunication cables\u003c\/th\u003e\n\u003cth style=\"padding: 9px 12px; text-align: left; font-size: 13px; font-weight: bold;\"\u003eMax modules per pack\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; font-weight: bold; color: #005c54; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003eUS2000B\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003e1 standard, 1 blue (Solis)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003e5 modules max per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; font-weight: bold; color: #005c54; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003eUS2000C\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003e1 standard, 1 blue (Solis)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003e5 modules max per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; font-weight: bold; color: #005c54; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003eUS3000\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003e1 standard, 1 blue (Solis)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003e3 modules max per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; font-weight: bold; color: #005c54; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003eUS3000C\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003e1 standard, 1 blue (Solis)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003e3 modules max per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; font-weight: bold; color: #005c54; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003eUS5000\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003e1 standard, 1 blue (Solis)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #f0f9f8; border-bottom: 1px solid #e0e0e0;\"\u003e2 modules max per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 14px; font-weight: bold; color: #005c54; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003eUP5000\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003e1 standard, 1 blue (Solis)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; font-size: 13px; background: #fff; border-bottom: 1px solid #e0e0e0;\"\u003e2 modules max per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #666; margin: -16px 0 20px;\"\u003eMaximum module counts per pack based on 100 A system limit. For stacks exceeding these counts, purchase a second cable pack and run cables in parallel to a busbar before connecting to the inverter.\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eHow Many Cable Packs Do I Need?\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(200px,1fr)); gap: 10px; margin-bottom: 16px;\"\u003e\n\u003cdiv style=\"background: #f0f9f8; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #008377;\"\u003e\n\u003cdiv style=\"font-size: 14px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eUp to 5 × US2000B\/C\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444; line-height: 1.5;\"\u003e1 cable pack\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f8f8f8; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #008377;\"\u003e\n\u003cdiv style=\"font-size: 14px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eUp to 3 × US3000\/C\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444; line-height: 1.5;\"\u003e1 cable pack\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0f9f8; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #008377;\"\u003e\n\u003cdiv style=\"font-size: 14px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eUp to 2 × US5000 or UP5000\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444; line-height: 1.5;\"\u003e1 cable pack\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f8f8f8; border-radius: 8px; padding: 14px 16px; border-left: 4px solid #008377;\"\u003e\n\u003cdiv style=\"font-size: 14px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eLarger stacks (any model)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444; line-height: 1.5;\"\u003e2 cable packs — run both sets in parallel to a busbar, then single run to inverter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 14px; color: #555; margin: 0 0 20px;\"\u003eEach 25 mm² cable is rated for \u003cstrong\u003e100 A continuous\u003c\/strong\u003e (120 A peak, 105°C insulation). If your system’s total charge\/discharge current exceeds 100 A, use two cable packs in parallel — connecting both positive cables and both negative cables at a busbar before the final run to the inverter terminals.\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"13\" width=\"13\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e25 mm² Solar-Grade Power Cables — 100 A Continuous Rating\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe two power cables use \u003cstrong\u003e25 mm² high-strand-count conductors\u003c\/strong\u003e with 105°C-rated insulation — well above standard cable insulation ratings. This higher insulation temperature allows the cables to carry \u003cstrong\u003e100 A continuously\u003c\/strong\u003e and up to 120 A peak without thermal degradation, which matches the maximum charge\/discharge rating of the US5000 and UP5000 modules. The solar-grade construction also gives flexibility and UV resistance for both indoor and outdoor cable runs.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e25mm²\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e100A continuous\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e105°C insulation\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"13\" width=\"13\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eAmphenol → M8 Ring Lug — Factory-Specified Terminations\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe battery end uses \u003cstrong\u003eAmphenol quick-lock connectors\u003c\/strong\u003e — the same proprietary locking interface built into all Pylontech US and UP battery modules. These connectors provide a secure, vibration-resistant, low-resistance connection that cannot be reversed (polarity-keyed). The inverter end terminates in standard \u003cstrong\u003eM8 ring lugs\u003c\/strong\u003e that fit the DC bus bar or inverter battery terminals found on virtually all hybrid and off-grid inverters.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eAmphenol battery connector\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eM8 ring lug (inverter end)\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003ePolarity-keyed\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"13\" width=\"13\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eTwo Communication Cables — Standard and Blue (Solis)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe UK pack includes \u003cstrong\u003etwo RJ45 communication cables\u003c\/strong\u003e with different pin-outs: a \u003cstrong\u003estandard cable\u003c\/strong\u003e for most RS485-compatible inverters (GivEnergy, Growatt, Sungrow, SolarEdge, Fronius and others), and a \u003cstrong\u003eblue-labelled cable\u003c\/strong\u003e specifically for \u003cstrong\u003eSolis inverters\u003c\/strong\u003e when using US-type C variant batteries. Having both in the pack means no additional comms cable purchase is needed for the vast majority of inverter brands. Always check your inverter’s BMS communication port pinout before connecting.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eStandard RJ45 comms\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eBlue cable for Solis\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eCovers most inverter brands\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #d97706; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #d97706; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"13\" width=\"13\"\u003e\u003cpath d=\"M12 9v4m0 4h.01M10.29 3.86L1.82 18a2 2 0 0 0 1.71 3h16.94a2 2 0 0 0 1.71-3L13.71 3.86a2 2 0 0 0-3.42 0z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #92400e; margin-bottom: 4px;\"\u003eNOT for Battery-to-Battery Parallel Links — Interlinks Already Supplied\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThis is one of the most common installation errors. These 2m cables are \u003cstrong\u003efor battery stack to DC disconnect or inverter only\u003c\/strong\u003e. The cables that connect one Pylontech module to the next in a stack (interlink \/ parallel cables) are \u003cstrong\u003esupplied inside the box with each battery unit\u003c\/strong\u003e. Using these 2m end-run cables as interlinks will result in incorrect cable lengths and potential current imbalance between modules.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eBattery → inverter\/DC disconnect\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eNOT battery → battery\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"13\" width=\"13\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eOfficial Factory Accessory — Designed for US and UP Series\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe CAB-PK-PYLON is the \u003cstrong\u003eofficial Pylontech cable accessory kit\u003c\/strong\u003e for the UK market, ensuring that conductor sizing, connector type, and pin-out are correct for the specific Amphenol interface on the US and UP series modules. Third-party cables with incorrect conductor sizing or non-Amphenol connectors can create connection resistance, heat build-up and BMS communication errors. Using the factory-specified cable pack also ensures warranty compliance with Pylontech’s terms.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eOfficial Pylontech accessory\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eCAB-PK-PYLON\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: .02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eWarranty-compliant\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 24px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: 'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\" colspan=\"2\"\u003ePack Contents (UK Version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePower cables\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e2 × 2m, 25 mm² (1 positive + 1 negative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eCommunication cables\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e2 × RJ45-to-RJ45 (1 standard + 1 blue\/Solis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eTotal cables per pack\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\" colspan=\"2\"\u003ePower Cable Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eConductor cross-section\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eCable length\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e2 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eBattery-end connector\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eAmphenol quick-lock (Pylontech proprietary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eInverter-end termination\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eM8 ring lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eContinuous current rating\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePeak current rating\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e120 A (short duration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eInsulation temperature rating\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eConstruction\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eSolar-grade, flexible, UV-resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\" colspan=\"2\"\u003eCommunication Cable Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eConnector type\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eRJ45 (both ends)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eProtocol supported\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eRS485 \/ CAN-bus (inverter-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eBlue-labelled cable\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eFor Solis inverters (US-type C variants)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\" colspan=\"2\"\u003eSystem Requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMax current per pack\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e100 A continuous charge\/discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMax US2000B or US2000C per pack\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e5 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMax US3000 or US3000C per pack\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e3 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMax US5000 or UP5000 per pack\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e2 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eLarger stacks\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eUse 2 cable packs in parallel to busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\" colspan=\"2\"\u003eCompatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eCompatible battery models\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eUS2000B, US2000C, US3000, US3000C, US5000, UP5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eNOT compatible with\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eParallel battery-to-battery connection (use interlink cables)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eVictron systems\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eAdditional Victron VE.Can CAN-bus BMS cable required (Type A or B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\" colspan=\"2\"\u003eProduct Reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePart number\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eCAB-PK-PYLON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003ePylontech (Pylon Technologies Co., Ltd.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eDo I need one cable pack or two for my system?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eOne cable pack handles systems up to \u003cstrong\u003e100 A total charge\/discharge\u003c\/strong\u003e. In practice this means: up to 5 × US2000B\/C, 3 × US3000\/C, or 2 × US5000\/UP5000 per pack. If your system exceeds these numbers, buy a second cable pack and run both sets in parallel — both positive cables and both negative cables — to a busbar, then run a single appropriately-sized cable from the busbar to the inverter terminals. Do not simply daisy-chain cables; parallel to busbar is the correct method for higher-current systems.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhy does the battery-to-battery (interlink) cable come with the battery?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eEach Pylontech US and UP series battery module ships with a short parallel interconnect cable pre-sized for the specific module-to-module gap in a standard stack. These short interlinks ensure equal current distribution between modules. The \u003cstrong\u003eCAB-PK-PYLON 2m cables are a completely separate function\u003c\/strong\u003e: they connect the top or bottom of the finished battery stack to the external system (DC disconnect switch, fuse, or inverter bus bar). The 2m length gives enough reach to accommodate most typical installation distances between the battery stack and the inverter.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhich communication cable do I use for my inverter?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eFor \u003cstrong\u003eSolis inverters\u003c\/strong\u003e with US-type C variant batteries: use the \u003cstrong\u003eblue-labelled communication cable\u003c\/strong\u003e. For all other RS485-compatible inverters (GivEnergy, Growatt, Sungrow, Fronius, SolarEdge, Huawei and others): use the \u003cstrong\u003estandard (unlabelled) communication cable\u003c\/strong\u003e. For \u003cstrong\u003eVictron Energy systems\u003c\/strong\u003e (Multiplus, Quattro, CerboGX, MPPT controllers): neither included cable is correct — you need a separate \u003cstrong\u003eVictron VE.Can to CAN-bus BMS cable, Type A or Type B (1.8m)\u003c\/strong\u003e, depending on your exact Pylontech model. Always verify against your inverter’s installation manual.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eAre the cables suitable for outdoor installation?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eYes. The 25 mm² conductors use \u003cstrong\u003esolar-grade insulation\u003c\/strong\u003e rated to 105°C, which is designed for both indoor and outdoor environments. If running cables outside between a battery enclosure and an inverter, it is good practice to run them through conduit to protect against mechanical damage and UV degradation, even though the cable insulation itself is UV-resistant.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhy are these 25 mm² cables if my inverter manual says 70 mm²?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eThis is a common question from installers. Standard 25 mm² PVC-insulated cables would struggle at 100 A, but these Pylontech cables use \u003cstrong\u003e105°C-rated insulation\u003c\/strong\u003e which substantially increases the current-carrying capacity compared to standard 70°C cable. The 2-metre length also means resistive losses are low. At 100 A or below on a 2m run these cables are correctly rated for the application. For systems drawing more than 100 A continuously, use two cable packs in parallel (effectively 2 × 25 mm² = 50 mm² per pole) or transition to heavier-gauge cabling after the busbar.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eRelated Products\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(210px,1fr)); gap: 10px; margin-bottom: 10px;\"\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003ePylontech US5000 4.8kWh LFP Battery\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003e48V LFP battery module — this cable pack is the official connection kit\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003ePylontech US3000C 3.5kWh LFP Battery\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003e48V 74Ah LFP battery — up to 3 modules per cable pack\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003ePylontech US2000C 2.4kWh LFP Battery\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003e48V 50Ah LFP battery — up to 5 modules per cable pack\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eVictron VE.Can to CAN-bus BMS Cable (Type B)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eRequired for Victron system communication with US5000\/US3000C\/US2000C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Pylontech","offers":[{"title":"Default Title","offer_id":62616642650461,"sku":"CAB-PK-PYLON","price":17.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Pylontech-2m-Cable-pack-for-US2000-US3000-Phantom-S-solar-batteries.webp?v=1763456669"},{"product_id":"mc4-in-line-fuse-20a-1500v-dc-single","title":"Staubli MC4 In Line Fuse 20A 1500V DC Single","description":"\u003ch2\u003eStaubli MC4 In Line Fuse 20A 1500V DC Single\u003c\/h2\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 20 Amps, ideal for overcurrent protection in solar photovoltaic (PV) systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 1500V DC, suitable for high-voltage solar installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Size:\u003c\/strong\u003e 10x85mm standard fuse element for easy replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e Robust, waterproof IP68 rated with UV resistance ensuring durability in harsh outdoor environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Crimped MC4 connectors compliantly certified providing secure, stable electrical connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +90°C, ensuring reliable function across wide climate conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e TÜV and cTÜVus certified for safety and performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy This Fuse?\u003c\/h3\u003e\n\u003cp\u003eThis MC4 In Line Fuse offers essential protection for your photovoltaic system by preventing overcurrent damage to panels and wiring. Its robust design and waterproof IP68 housing provide extended reliability in outdoor installations, while the industry-standard MC4 connectors simplify integration with existing PV cabling. Perfect for residential and commercial solar setups requiring certified protection components.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMC4-FUSE-20A-1500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Element Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 x 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMC4 Crimped Connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTÜV, cTÜVus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Staubli","offers":[{"title":"Default Title","offer_id":62618693763421,"sku":"MC4-FUSE-20A-1500V","price":35.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/StaubliMC4InLineFuse20A1500VDCSingle.jpg?v=1763462262"},{"product_id":"aiko-2-3m-extension-cable","title":"Aiko 2.3m Extension Cable","description":"\u003ch1\u003eAiko 2.3m Extension Cable\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eAiko 2.3m Extension Cable\u003c\/strong\u003e is a high-quality cable designed to extend the length of existing solar photovoltaic system connections. Ideal for use with Aiko solar modules and compatible system components, this cable ensures reliable power transfer and secure connectivity in a variety of installation scenarios.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e 2.3 meters, providing ample reach for flexible system layout and module spacing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Quality Connectors:\u003c\/strong\u003e Equipped with durable, weatherproof MC4-compatible connectors to ensure safe and reliable connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather Resistant:\u003c\/strong\u003e UV-resistant and designed for outdoor use, withstands exposure to harsh environmental conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Specifically compatible with Aiko solar panels and general photovoltaic systems requiring extension cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Electrical Loss:\u003c\/strong\u003e Constructed with high-quality materials to minimize voltage drop and power loss over extended distances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eAIK-EXT-1.2M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e2.3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMC4-compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eSolar-grade, UV-resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSolar PV system extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength Tolerance\u003c\/td\u003e\n\u003ctd\u003e±0.1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe Aiko 2.3m Extension Cable is an essential accessory for photovoltaic system installers and designers, offering flexibility in system configuration while ensuring high-quality, weather-proof power transmission between modules and system components.\u003c\/p\u003e","brand":"Aiko Solar","offers":[{"title":"Default Title","offer_id":62729145680221,"sku":"AIK-EXT-1.2M","price":15.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Aiko2.3mExtensionCable.jpg?v=1764167592"},{"product_id":"enphase-replacement-dc-adaptor-to-mc4-connector","title":"Enphase Replacement DC Adaptor to MC4 Connector","description":"\u003ch1\u003eEnphase Replacement DC Adaptor to MC4 Connector\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eEnphase Replacement DC Adaptor to MC4 Connector\u003c\/strong\u003e (Part No: EN-Q-DCC-2-INT) is a reliable and durable adaptor designed to connect DC wiring from photovoltaic modules or other DC power sources to standard MC4 connectors. It ensures secure, weatherproof connections compatible with Enphase solar system components.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Adaptor:\u003c\/strong\u003e Designed as a direct replacement for broken or damaged DC adaptors in Enphase PV systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMC4 Compatibility:\u003c\/strong\u003e Ensures seamless integration with MC4 connector standards widely used in solar installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeatherproof Design:\u003c\/strong\u003e Built to withstand harsh outdoor conditions with IP65 or higher ingress protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Quality Materials:\u003c\/strong\u003e Constructed with UV-resistant plastics and corrosion-resistant metal contacts for long-term durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Simple plug-and-play solution requiring no special tools or splicing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Ratings:\u003c\/strong\u003e Rated for standard PV system voltages and currents, suitable for safe and efficient power transmission.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eEN-Q-DCC-2-INT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eDC Adaptor to MC4 Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eCompatible with MC4 connectors and Enphase DC wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP65 or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eUV-resistant plastic housing, corrosion-resistant contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Ratings\u003c\/td\u003e\n\u003ctd\u003eSuitable for photovoltaic voltage and current levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe Enphase Replacement DC Adaptor to MC4 Connector is essential for maintaining and repairing PV wiring connections, ensuring safe, reliable, and weatherproof power transmission within solar energy systems.\u003c\/p\u003e","brand":"Enphase","offers":[{"title":"Default Title","offer_id":62729863102813,"sku":"EN-Q-DCC-2-INT","price":15.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/EnphaseReplacementDCAdaptortoMC4ConnectorEN-Q-DCC-2-INT.jpg?v=1764174258"},{"product_id":"q-cable-disconnect-tool","title":"Q Cable Disconnect Tool","description":"\u003cp\u003eThe \u003cstrong\u003eQ Cable Disconnect Tool\u003c\/strong\u003e is a specialized hand tool designed to safely and efficiently disconnect Q Cable connectors used in Enphase solar PV systems. This tool ensures the secure release of clip-style connectors without damaging the cable or connector, facilitating maintenance and system modifications.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Design:\u003c\/strong\u003e Specifically engineered to fit Enphase Q Cable connectors for easy and damage-free disconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe \u0026amp; Ergonomic:\u003c\/strong\u003e Provides a comfortable grip and controlled release force to prevent connector or cable damage during maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Materials:\u003c\/strong\u003e Manufactured from high-quality, robust materials for long-lasting use in field conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact \u0026amp; Portable:\u003c\/strong\u003e Lightweight and easy to carry, ideal for solar installers and service technicians.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEssential for Maintenance:\u003c\/strong\u003e Ideal for safely disconnecting cables during system upgrades, troubleshooting, or repairs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eEN-Q-DISC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTool Type\u003c\/td\u003e\n\u003ctd\u003eQ Cable Disconnect Tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eDesigned for Enphase Q Cable connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eDurable plastic and metal components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eLightweight and ergonomic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse Case\u003c\/td\u003e\n\u003ctd\u003eSafe disconnection of Q Cable connectors during maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe Q Cable Disconnect Tool is an essential accessory for professional solar PV installers and technicians, ensuring quick, safe, and damage-free disconnection of Enphase Q Cable connectors on-site.\u003c\/p\u003e","brand":"Enphase","offers":[{"title":"Default Title","offer_id":62729873293661,"sku":"EN-Q-DISC","price":7.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/QCableDisconnectToolEN-Q-DISC-01_1.jpg?v=1764174455"},{"product_id":"q-cable-round-3phase-ac-branch-terminator","title":"Q-Cable round 3Phase AC Branch Terminator","description":"\u003ch1\u003eQ-Cable Round 3-Phase AC Branch Terminator (1 Item)\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eQ-Cable Round 3-Phase AC Branch Terminator\u003c\/strong\u003e is a crucial component used to safely terminate unused three-phase AC branch connections in solar photovoltaic systems. Designed for use with Enphase Q-Cable wiring, this terminator ensures reliable electrical isolation and system safety.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure Branch Termination:\u003c\/strong\u003e Provides a reliable closure for unused 3-phase AC branch connectors, preventing electrical faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed specifically for Enphase Q-Cable round 3-phase AC wiring systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather Resistant:\u003c\/strong\u003e Constructed with durable, weatherproof materials suitable for outdoor installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Simple plug-and-lock mechanism enables quick and secure fitting without special tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Safety:\u003c\/strong\u003e Helps maintain compliance with electrical codes by properly terminating unused connectors to avoid loose ends or accidental contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Long-lasting materials ensure stable performance even under harsh environmental conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eEN-Q-TERM-3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e3-Phase AC Branch Cable Terminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eEnphase Q-Cable 3-Phase AC wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eWeather-resistant enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003ePlug-and-lock operation, no tools needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eUV-resistant plastic and corrosion-resistant contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse Case\u003c\/td\u003e\n\u003ctd\u003eSafe termination of unused 3-phase branch connectors in PV systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe Q-Cable Round 3-Phase AC Branch Terminator is essential for ensuring electrical safety and system integrity in Enphase solar installations by securely terminating unused 3-phase AC branches.\u003c\/p\u003e","brand":"Enphase","offers":[{"title":"Default Title","offer_id":62729882206557,"sku":"EN-Q-TERM-3P","price":17.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Q-Cableround3PhaseACBranchTerminatorEN-Q-TERM-3P.jpg?v=1764174610"},{"product_id":"q-cable-round-ac-branch-terminator-1-item","title":"Q-Cable Round AC Branch Terminator (1 Item)","description":"\u003ch1\u003eQ-Cable Round AC Branch Terminator (1 Item)\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eQ-Cable Round AC Branch Terminator\u003c\/strong\u003e is a vital accessory used for safely terminating unused single-phase AC branch connections in Enphase solar photovoltaic systems. It ensures electrical safety and system integrity by preventing accidental contact or faults on open connectors.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure Termination:\u003c\/strong\u003e Provides a reliable seal for unused single-phase AC branch connectors, ensuring system safety and compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigned for Compatibility:\u003c\/strong\u003e Specifically engineered for use with Enphase Q-Cable round AC wiring systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeatherproof Construction:\u003c\/strong\u003e Built with durable materials to withstand outdoor environmental stress including UV exposure and moisture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Simple plug-and-lock design allows quick and tool-free fitting on site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable and Safe:\u003c\/strong\u003e Maintains connector integrity over time while protecting against moisture ingress and physical damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eEN-Q-TERM-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSingle-Phase AC Branch Cable Terminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eEnphase Q-Cable Round AC Wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eWeather-resistant, UV-protected enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eTool-free plug and lock operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eUV-resistant plastic, corrosion-resistant contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSafe termination of unused single-phase AC branch connectors in photovoltaic systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe Q-Cable Round AC Branch Terminator is essential for ensuring safe and compliant termination of open AC branch connectors in Enphase PV installations, preventing safety risks and maintaining system reliability.\u003c\/p\u003e","brand":"Enphase","offers":[{"title":"Default Title","offer_id":62729894101341,"sku":"EN-Q-TERM-R","price":17.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Q-Cableround3PhaseACBranchTerminatorEN-Q-TERM-3P.jpg?v=1764174610"},{"product_id":"eleven-energy-battery-battery-parallel-cable-set-235mm","title":"Eleven Energy Battery-Battery Parallel Cable Set 235mm","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003e\u003cstrong\u003eEleven Energy Battery‑Battery Parallel Cable Set 235mm\u003c\/strong\u003e is a short pre‑terminated cable kit for linking two Eleven Volta sodium‑ion batteries together in parallel. It is intended for use where the battery packs are stacked directly adjacent to each other, keeping connections neat and resistance low.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesigned for Eleven Volta batteries\u003c\/strong\u003e – compatible with Eleven Energy’s Volta sodium‑ion battery packs for straightforward parallel expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort 235 mm length\u003c\/strong\u003e – optimised for batteries that are stacked together horizontally or vertically inside a shared enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery‑to‑battery parallel links\u003c\/strong\u003e – used to connect the positive terminals together and the negative terminals together when adding a second pack in parallel, in line with the Volta installation manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre‑fitted connectors\u003c\/strong\u003e – supplied with suitable terminations at both ends for quick, reliable connection to the battery power terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplication \u0026amp; Use\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort cable set\u003c\/strong\u003e – best suited where batteries are closely spaced in an enclosure, rack or stack so that long, looping cables are not required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel expansion\u003c\/strong\u003e – enables simple capacity increases by adding a second Volta pack in parallel, while keeping cable runs equal and tidy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem layout\u003c\/strong\u003e – for wall‑mounted batteries with greater spacing, a separate longer wall‑mount parallel cable set is available to suit that configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the Volta battery installation instructions for the correct sequence when paralleling packs, including setting DIP switches and using the dedicated parallel communication ports.\u003c\/li\u003e\n\u003cli\u003eEnsure correct polarity at all times; positive to positive and negative to negative, with the inverter connected via appropriately rated battery cables and protection.\u003c\/li\u003e\n\u003cli\u003eAll high‑current battery wiring should be carried out by a competent person, with isolation and torque settings as specified in the Volta documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Eleven Energy","offers":[{"title":"Default Title","offer_id":62931902333277,"sku":"Eleven-Parallel-Cable Set","price":95.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/ElevenEnergyBattery-BatteryParallelCableSet235mm.jpg?v=1766082508"},{"product_id":"eleven-energy-battery-enclosure-parallel-cable-set-1-2m","title":"Eleven Energy Battery Enclosure Parallel Cable Set 1.2m","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003e\u003cstrong\u003eEleven Energy Battery Enclosure Parallel Cable Set 1.2m\u003c\/strong\u003e is a long, heavy‑duty parallel cable pair for linking Eleven Volta sodium‑ion batteries installed in separate Eleven battery enclosures. It is designed for multi‑cabinet layouts where batteries are not directly adjacent, keeping high‑current DC links safe and tidy.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.2 m battery-to-battery links\u003c\/strong\u003e – extended length cables to bridge the gap between separate Eleven battery enclosures in a multi‑battery system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFor multi-enclosure systems\u003c\/strong\u003e – typically one pair is required for systems with 3–4 batteries, two pairs for 5–6 batteries, and so on, allowing each additional enclosure to be paralleled into the bank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatched to Volta batteries\u003c\/strong\u003e – intended for use with Eleven Volta sodium‑ion batteries as the approved enclosure‑to‑enclosure parallel connection set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-current capable\u003c\/strong\u003e – built from appropriately sized 35 mm² battery cable to handle the DC currents associated with parallel battery banks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplication \u0026amp; Use\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure-to-enclosure links\u003c\/strong\u003e – ideal where batteries are housed in multiple Eleven Battery Enclosures, spaced further apart than short inter‑battery cables can reach.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupports balanced parallel banks\u003c\/strong\u003e – helps maintain sensible, consistent cable routing between cabinets so that parallel packs share current effectively.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplements short parallel sets\u003c\/strong\u003e – used alongside the shorter 235 mm battery‑battery parallel cable sets that link batteries within a single enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-site crimping required\u003c\/strong\u003e – one end of each cable is supplied uncrimped and must be terminated on site; a crimping die suitable for 35 mm² cable is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrect polarity\u003c\/strong\u003e – always connect positive to positive and negative to negative, with suitable DC isolation and fusing for the overall battery bank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable routing\u003c\/strong\u003e – route cables neatly between enclosures, protect against abrasion and strain, and observe bend radius and manufacturer installation guidance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompetent installation\u003c\/strong\u003e – all high‑current DC work should be carried out by a suitably qualified or competent installer, following the Volta battery and enclosure instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Eleven Energy","offers":[{"title":"Default Title","offer_id":62931910918493,"sku":"Eleven-Enclosure-Parallel-Cable Set","price":59.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/ElevenEnergyBatteryEnclosureParallelCableSet1.2m.jpg?v=1766082657"},{"product_id":"mersen-mb000-125a-3p-bottom-panel-mount-fuse-switch-disconnector","title":"Mersen MB000 125A 3P Bottom Panel Mount Fuse Switch Disconnector","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eMersen MB000 125A 3P Bottom\/Panel Mount Fuse Switch Disconnector\u003c\/strong\u003e is a robust three-pole fuse switch disconnector designed for safe isolation and protection in low-voltage electrical systems, suitable for panel or bottom mounting in industrial and commercial applications.\u003c\/p\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe MB000 series from Mersen is a compact, modular fuse switch disconnector rated for 125A at 690V AC, providing reliable circuit protection and isolation. It accommodates NH size 000 fuses for easy replacement and features a padlockable handle for lockout\/tagout safety. Ideal for distribution boards, motor control centers, and renewable energy systems, it ensures compliance with IEC standards for electrical safety and efficiency.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-pole configuration:\u003c\/strong\u003e Simultaneous disconnection of all phases for safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePadlockable handle:\u003c\/strong\u003e Allows secure lockout during maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact modular design:\u003c\/strong\u003e Easy integration into panels or enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse compatibility:\u003c\/strong\u003e Accepts NH000 fuses for quick replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh breaking capacity:\u003c\/strong\u003e Up to 100 kA for fault protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBottom\/panel mount:\u003c\/strong\u003e Flexible installation options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP20 rating:\u003c\/strong\u003e Touch-safe terminals for user protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e D1070423 – MB000 125A 3P Fuse Switch Disconnector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 125 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage:\u003c\/strong\u003e 690 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse size:\u003c\/strong\u003e NH000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking capacity:\u003c\/strong\u003e 100 kA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower dissipation:\u003c\/strong\u003e \u0026lt;10 W per pole at rated current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC 60947-3 compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDimensions \u0026amp; Weights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 106 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 70 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 135 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.65 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSystem \u0026amp; Application Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for low-voltage distribution, motor protection, and PV systems requiring fuse isolation.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard NH fuses; mount on DIN rail or panel.\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial and commercial setups; ensures safe disconnection under load.\u003c\/li\u003e\n\u003cli\u003eInstallation by qualified electricians following IEC guidelines.\u003c\/li\u003e\n\u003cli\u003eEnhances system safety with lockable mechanism; no maintenance required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Mersen","offers":[{"title":"Default Title","offer_id":63355258569053,"sku":"D1070423","price":43.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/MersenMB000125A3PBottomPanelMountFuseSwitchDisconnector.jpg?v=1770611493"},{"product_id":"mersen-125a-fuse-nh-gg-400v-size-000","title":"Mersen 125A Fuse - NH gG 400V size 000","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eMersen 125A Fuse - NH gG 400V size 000\u003c\/strong\u003e is a standard NH fuse-link designed for general purpose cable and line protection in low-voltage electrical systems, featuring gG characteristics, 400VAC rating, and double indicator for status monitoring.\u003c\/p\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe Mersen NH gG fuse-link is a plug-in type fuse for DIN NH systems, classified as gG for general purpose protection of cables and lines. It features a ceramic body with a width of 21mm and double indicator for visual status check. Rated at 125A and 400VAC, it provides reliable overcurrent protection in industrial and commercial applications, compliant with IEC standards.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003egG characteristics:\u003c\/strong\u003e General purpose for cable and line protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble indicator:\u003c\/strong\u003e Visual status for live gripping lugs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNH size 000:\u003c\/strong\u003e Standard DIN NH fuse-link format.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCeramic body:\u003c\/strong\u003e Durable material for high-performance applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody width 21mm:\u003c\/strong\u003e Slim profile for space-saving installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower dissipation:\u003c\/strong\u003e 8.5 W for energy efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC compliant:\u003c\/strong\u003e Meets international standards for safety and reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e X1208371 – NH gG Fuse Size 000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 125 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated voltage:\u003c\/strong\u003e 400 V AC IEC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse type:\u003c\/strong\u003e gG (general purpose).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse size:\u003c\/strong\u003e NH000.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody material:\u003c\/strong\u003e Ceramic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower dissipation:\u003c\/strong\u003e 8.5 W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking capacity:\u003c\/strong\u003e 120 kA (AC Max I.R.).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC 60947-3 compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDimensions \u0026amp; Weights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody width:\u003c\/strong\u003e 21 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~0.15 kg (approximate).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSystem \u0026amp; Application Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for low-voltage distribution, motor protection, and PV systems requiring gG fuse protection.\u003c\/li\u003e\n\u003cli\u003eCompatible with NH fuse holders and switch disconnectors.\u003c\/li\u003e\n\u003cli\u003eSuitable for DIN NH systems; install in plug-in fuse bases.\u003c\/li\u003e\n\u003cli\u003eInstallation by qualified electricians following IEC guidelines.\u003c\/li\u003e\n\u003cli\u003eEnhances system safety with double indicator for quick status check.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Mersen","offers":[{"title":"Default Title","offer_id":63355278754141,"sku":"X1208371","price":6.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Mersen125AFuse-NHgG400Vsize000.webp?v=1770611881"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/collections\/solar-cables.webp?v=1772438445","url":"https:\/\/qualityheating.co.uk\/collections\/solar-cables-battery-cables-connectors.oembed?page=3","provider":"AIZO Quality Heating","version":"1.0","type":"link"}