{"title":"Metering","description":"\u003cp\u003e\u003cspan\u003eMonitor and optimise your solar energy system with our precision solar metering accessories. Designed to provide accurate data on energy generation, consumption, and system performance, these meters and sensors help you maximise efficiency and savings. Whether for residential or commercial solar setups, our reliable metering solutions deliver clear insights and seamless integration with your renewable energy equipment.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"livoltek-single-phase-smart-meter-lhe12c","title":"Livoltek Single Phase Smart Meter - LHE12C","description":"\u003c!-- Livoltek Single Phase Smart Meter LHE12C - Product Description \u0026 Technical Specification --\u003e\n\u003cp\u003eThe Livoltek Single Phase Smart Meter LHE12C is designed for accurate monitoring, measurement, and control of single-phase AC coupled or hybrid inverter systems. This compact, two-wire smart energy meter supports nominal voltages of 220V, 230V, and 240V, and is widely compatible across a range of solar, battery, and grid applications. It delivers Class 1 accuracy for active energy and integrates easily with Livoltek solutions for intelligent energy management.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Phase Monitoring:\u003c\/strong\u003e Built for 1P2W (single-phase two-wire) applications, supporting AC coupled and hybrid inverter systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Voltage Range:\u003c\/strong\u003e Operates at 220V\/230V\/240V, with an operating voltage window from 70% to 130% Un.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy:\u003c\/strong\u003e Class 1 active energy measurement; Class 2 reactive energy measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Measurement:\u003c\/strong\u003e Supports up to 80A direct measurement or up to 250A via open-type CT connection options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Dimensions 100mm x 18mm x 69mm for easy DIN-rail mounting and integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Frequency:\u003c\/strong\u003e Compatible with 50Hz\/60Hz electrical networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart System Integration:\u003c\/strong\u003e Can be paired with Livoltek solar and battery hardware for intelligent management and detailed monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLHE12C \/ LHE12D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003ctd\u003eSingle-phase two-wire (1P2W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Voltage\u003c\/th\u003e\n\u003ctd\u003e220V \/ 230V \/ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Voltage Range\u003c\/th\u003e\n\u003ctd\u003e70%Un – 130%Un\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent Rating\u003c\/th\u003e\n\u003ctd\u003e80A (direct); up to 250A (via CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement Accuracy\u003c\/th\u003e\n\u003ctd\u003eActive Energy: Class 1, Reactive Energy: Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50Hz \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e-25°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (HxWxD)\u003c\/th\u003e\n\u003ctd\u003e100mm x 18mm x 69mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eDIN-rail (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Code\u003c\/th\u003e\n\u003ctd\u003eLHE12DRR11001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAC-coupled and hybrid inverter systems for grid-tie, off-grid, and battery storage setups.\u003c\/li\u003e\n\u003cli\u003eSingle-phase residential and commercial power metering.\u003c\/li\u003e\n\u003cli\u003eIntelligent energy management with Livoltek solar and battery systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose the Livoltek LHE12C Smart Meter?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePrecise measurement ensures effective energy monitoring and control.\u003c\/li\u003e\n\u003cli\u003eEasy integration with Livoltek products for smart solar and battery solutions.\u003c\/li\u003e\n\u003cli\u003eCompact and reliable DIN-rail mounting makes installation straightforward.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Livoltek","offers":[{"title":"Default Title","offer_id":58374266224989,"sku":"LHE12DRR11001","price":43.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/LivoltekSinglePhaseSmartMeterLHE12C.png?v=1756438290"},{"product_id":"solax-wi-br-wireless-bridge","title":"SolaX Wi-BR Wireless Bridge | 200m Range | IEEE 802.11ah","description":"\u003c!-- SEO Product Name: SolaX Wi-BR Wireless Bridge | 200m Range | IEEE 802.11ah --\u003e\n\u003cdiv style=\"font-size: 16px; max-width: 900px; color: #1a1a1a; line-height: 1.6;\"\u003e\n\u003cp style=\"margin: 0 0 16px 0;\"\u003eThe \u003cstrong\u003eSolaX Wi-BR Wireless Bridge\u003c\/strong\u003e removes the need for physical communication cabling between a SolaX inverter and its energy meter, replacing an RS485 cable run with a \u003cstrong\u003estable long-range wireless link\u003c\/strong\u003e. Built on the low-power, long-range \u003cstrong\u003eIEEE 802.11ah protocol\u003c\/strong\u003e, it maintains \u003cstrong\u003ereliable data transmission up to 200 metres\u003c\/strong\u003e in open, unobstructed conditions and can push a signal through \u003cstrong\u003eup to four floors or 120cm of reinforced concrete\u003c\/strong\u003e (roughly 30 metres vertically), making it a practical fix for inverters and meters that sit too far apart — or on different floors — for a cable to be routed easily.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 24px 0;\"\u003eWorking in \u003cstrong\u003eAP\/STA mode\u003c\/strong\u003e and compatible with \u003cstrong\u003eboth single-phase and three-phase meters\u003c\/strong\u003e, the Wi-BR slots into SolaX hybrid and grid-tie systems to keep \u003cstrong\u003eexport limitation, real-time monitoring, and SolaX Cloud data access\u003c\/strong\u003e running without a dedicated data cable. It mounts on a standard \u003cstrong\u003eDIN rail\u003c\/strong\u003e inside the consumer unit or inverter cabinet, drawing power directly from an \u003cstrong\u003e85–277V AC\u003c\/strong\u003e supply, and is built for a \u003cstrong\u003e2W\u003c\/strong\u003e standby draw so it can stay powered permanently alongside the rest of the installation's control gear.\u003c\/p\u003e\n\u003c!-- Stat strip --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px; margin: 0 0 24px 0;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 130px; background: #f4f9f8; border-top: 3px solid #008377CF; padding: 14px 12px; text-align: center; border-radius: 4px;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; color: #008377cf;\"\u003e200m\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555;\"\u003eOpen-space range\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 130px; background: #f4f9f8; border-top: 3px solid #008377CF; padding: 14px 12px; text-align: center; border-radius: 4px;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; color: #008377cf;\"\u003e4 floors\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555;\"\u003ePenetration (~30m)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 130px; background: #f4f9f8; border-top: 3px solid #008377CF; padding: 14px 12px; text-align: center; border-radius: 4px;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; color: #008377cf;\"\u003e2W\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555;\"\u003eMax. power draw\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 130px; background: #f4f9f8; border-top: 3px solid #008377CF; padding: 14px 12px; text-align: center; border-radius: 4px;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; color: #008377cf;\"\u003eIP20\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555;\"\u003eIngress protection\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 130px; background: #f4f9f8; border-top: 3px solid #008377CF; padding: 14px 12px; text-align: center; border-radius: 4px;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; color: #008377cf;\"\u003eDIN\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555;\"\u003eRail mounting\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 130px; background: #f4f9f8; border-top: 3px solid #008377CF; padding: 14px 12px; text-align: center; border-radius: 4px;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; color: #008377cf;\"\u003e2 Yrs\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555;\"\u003eManufacturer warranty\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Amber callout: data conflict \/ source variance --\u003e\u003c!-- Teal informational callout --\u003e\n\u003cdiv style=\"background: #f4f9f8; border-left: 4px solid #008377CF; padding: 14px 16px; margin: 0 0 28px 0; border-radius: 4px;\"\u003e\n\u003cstrong style=\"color: #008377cf;\"\u003eBest suited to:\u003c\/strong\u003e installations where the inverter and meter are separated by distance, floors, or thick masonry that would make a physical RS485 run impractical — extensions, outbuildings, multi-storey properties, and retrofits where cable access is limited.\u003c\/div\u003e\n\u003c!-- Feature grid --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 14px; margin: 0 0 28px 0;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 250px; border: 1px solid #e0e0e0; border-radius: 6px; padding: 16px;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003eCable-Free Installation\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444;\"\u003eEliminates the need to run a physical RS485 cable between inverter and meter, cutting installation time and avoiding disruptive cable routes through walls or floors.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 250px; border: 1px solid #e0e0e0; border-radius: 6px; padding: 16px;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003eLong-Range, Low-Power Protocol\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444;\"\u003eUses IEEE 802.11ah, purpose-built for long-range, low-power wireless communication — far more robust over distance than standard Wi-Fi.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 250px; border: 1px solid #e0e0e0; border-radius: 6px; padding: 16px;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003eStrong Wall Penetration\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444;\"\u003eMaintains a reliable link through up to four floors or 120cm of reinforced concrete, with strong anti-interference performance in busy RF environments.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 250px; border: 1px solid #e0e0e0; border-radius: 6px; padding: 16px;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003eUniversal Meter Compatibility\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444;\"\u003eWorks with both single-phase and three-phase energy meters, so one accessory covers domestic and small commercial SolaX installations alike.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 250px; border: 1px solid #e0e0e0; border-radius: 6px; padding: 16px;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003eCompact DIN-Rail Design\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444;\"\u003eAt just 18mm wide, it sits neatly on a standard DIN rail inside the consumer unit or inverter enclosure without crowding other components.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 250px; border: 1px solid #e0e0e0; border-radius: 6px; padding: 16px;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003eFull System Visibility\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #444;\"\u003eKeeps SolaX Cloud monitoring, export limitation, and real-time energy data flowing reliably, even where a wired connection isn't practical.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Spec table --\u003e\n\u003cdiv style=\"margin: 0 0 28px 0;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: bold; padding: 10px 14px; border-radius: 4px 4px 0 0;\"\u003eCommunication\u003c\/div\u003e\n\u003cdiv style=\"display: flex; padding: 10px 14px; background: #f7f7f7; border-bottom: 1px solid #eee;\"\u003e\n\u003cdiv style=\"flex: 1; color: #555;\"\u003eWorking method\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; font-weight: 600;\"\u003eAP \/ STA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; padding: 10px 14px; border-bottom: 1px solid #eee;\"\u003e\n\u003cdiv style=\"flex: 1; color: #555;\"\u003eProtocol\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; font-weight: 600;\"\u003eIEEE 802.11ah\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; padding: 10px 14px; background: #f7f7f7; border-bottom: 1px solid #eee;\"\u003e\n\u003cdiv style=\"flex: 1; color: #555;\"\u003eCommunication terminal\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; font-weight: 600;\"\u003eRS485 × 1 (per unit)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; padding: 10px 14px; border-bottom: 1px solid #eee;\"\u003e\n\u003cdiv style=\"flex: 1; color: #555;\"\u003eMeter compatibility\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; font-weight: 600;\"\u003eSingle-phase and three-phase\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; padding: 10px 14px; background: #f7f7f7; border-bottom: 1px solid #eee;\"\u003e\n\u003cdiv style=\"flex: 1; color: #555;\"\u003eTransmission range (open space)\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; font-weight: 600;\"\u003eUp to 200m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; padding: 10px 14px; border-bottom: 1px solid #eee;\"\u003e\n\u003cdiv style=\"flex: 1; color: #555;\"\u003ePenetration\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; font-weight: 600;\"\u003eUp to 4 floors \/ 120cm reinforced concrete (~30m vertical)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: bold; padding: 10px 14px; margin-top: 16px;\"\u003eElectrical\u003c\/div\u003e\n\u003cdiv style=\"display: flex; padding: 10px 14px; background: #f7f7f7; border-bottom: 1px solid #eee;\"\u003e\n\u003cdiv style=\"flex: 1; color: #555;\"\u003ePhase voltage\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; font-weight: 600;\"\u003e85–277V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; padding: 10px 14px; border-bottom: 1px solid #eee;\"\u003e\n\u003cdiv style=\"flex: 1; color: #555;\"\u003eMax. power consumption\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; font-weight: 600;\"\u003e2W\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: bold; padding: 10px 14px; margin-top: 16px;\"\u003ePhysical \u0026amp; Environmental\u003c\/div\u003e\n\u003cdiv style=\"display: flex; padding: 10px 14px; background: #f7f7f7; border-bottom: 1px solid #eee;\"\u003e\n\u003cdiv style=\"flex: 1; color: #555;\"\u003eDimensions (W × H × D)\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; font-weight: 600;\"\u003e18mm × 98mm × 66mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; padding: 10px 14px; border-bottom: 1px solid #eee;\"\u003e\n\u003cdiv style=\"flex: 1; color: #555;\"\u003eMounting type\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; font-weight: 600;\"\u003eDIN rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; padding: 10px 14px; background: #f7f7f7; border-bottom: 1px solid #eee;\"\u003e\n\u003cdiv style=\"flex: 1; color: #555;\"\u003eIngress protection rating\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; font-weight: 600;\"\u003eIP20\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; padding: 10px 14px; border-bottom: 1px solid #eee;\"\u003e\n\u003cdiv style=\"flex: 1; color: #555;\"\u003eOperating temperature\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; font-weight: 600;\"\u003e-25°C to +55°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; padding: 10px 14px; background: #f7f7f7; border-bottom: 1px solid #eee;\"\u003e\n\u003cdiv style=\"flex: 1; color: #555;\"\u003eMaximum altitude\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; font-weight: 600;\"\u003e2000m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; padding: 10px 14px; border-bottom: 1px solid #eee;\"\u003e\n\u003cdiv style=\"flex: 1; color: #555;\"\u003eManufacturer warranty\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; font-weight: 600;\"\u003e2 years\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ accordion --\u003e\n\u003cdiv style=\"margin: 0 0 8px 0;\"\u003e\n\u003cdetails style=\"margin-bottom: 8px; border: 1px solid #e0e0e0; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #fff; padding: 12px 16px; cursor: pointer; font-weight: 600; list-style: none;\"\u003eDoes the Wi-BR replace the inverter's built-in Wi-Fi dongle?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; color: #444;\"\u003eNo. The Wi-BR is specifically a bridge between the inverter and the \u003cstrong\u003eenergy meter\u003c\/strong\u003e, replacing the RS485 meter cable with a wireless link. It doesn't provide internet connectivity for the inverter itself — that's handled separately by the inverter's own Wi-Fi, LAN, or 4G dongle.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 8px; border: 1px solid #e0e0e0; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #fff; padding: 12px 16px; cursor: pointer; font-weight: 600; list-style: none;\"\u003eDo I need one Wi-BR unit or two for a wireless link?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; color: #444;\"\u003eA wireless bridge link requires \u003cstrong\u003etwo Wi-BR units\u003c\/strong\u003e — one paired with the inverter's RS485 port and one paired with the meter's RS485 port, communicating with each other over the air. Each product listing is for a single unit.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 8px; border: 1px solid #e0e0e0; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #fff; padding: 12px 16px; cursor: pointer; font-weight: 600; list-style: none;\"\u003eWill the 200m range hold up in a typical UK house?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; color: #444;\"\u003eThe \u003cstrong\u003e200m figure applies to open, unobstructed space\u003c\/strong\u003e. Indoors, walls and floors reduce range, though the Wi-BR is rated to maintain a link through up to \u003cstrong\u003e4 floors or 120cm of reinforced concrete\u003c\/strong\u003e — more than enough for the vast majority of domestic and light commercial installations.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 8px; border: 1px solid #e0e0e0; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #fff; padding: 12px 16px; cursor: pointer; font-weight: 600; list-style: none;\"\u003eIs it compatible with any SolaX inverter?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; color: #444;\"\u003eThe Wi-BR is designed for SolaX inverters that support an external RS485 meter connection. Check your specific inverter model's manual to confirm RS485 meter input is available before ordering.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 0; border: 1px solid #e0e0e0; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #fff; padding: 12px 16px; cursor: pointer; font-weight: 600; list-style: none;\"\u003eDoes it need its own power supply?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; color: #444;\"\u003eYes. The Wi-BR draws its own AC supply (\u003cstrong\u003e85–277V AC, 2W max\u003c\/strong\u003e) via its DIN-rail connection — it isn't powered over the RS485 line, so a live\/neutral feed needs to be available at the mounting point.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Solax","offers":[{"title":"Default Title","offer_id":58693526061405,"sku":"SOLAX-Wi-BR","price":67.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SolaxWi-BRWirelessBridge.jpg?v=1761588486"},{"product_id":"solax-ctsa016-100a-ct-clamp","title":"Solax CTSA016 100A CT Clamp","description":"\u003ch2\u003eSolax CTSA016 100A CT Clamp\u003c\/h2\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Transformer Rating:\u003c\/strong\u003e 100 Amps, suitable for monitoring current flow in solar and battery inverter systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit-Core Design:\u003c\/strong\u003e Allows easy installation without disconnecting conductors, ensuring safer and faster setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Length:\u003c\/strong\u003e 0.5 metres standard cable length, extendable up to 30 metres with standard 2-core data cable (e.g., CAT5).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for use with SolaX X1 series AC-coupled battery inverters and hybrid systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Durable materials with epoxy encapsulated housing and nylon case rated UL94 V-0 flame retardant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e Suitable for operating temperatures from -15°C to +60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy Class:\u003c\/strong\u003e 0.5 or 1.0 IEC 60044-1 compliant for precise current measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e ETL certified and RoHS compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy the CTSA016 100A CT Clamp?\u003c\/h3\u003e\n\u003cp\u003eThe CTSA016 clamp offers efficient and reliable current measurement for solar photovoltaic and hybrid battery inverter systems. Its split-core design enables installation without system downtime, facilitating safer maintenance and upgrades. Certified for accuracy and reliability, it ensures optimal performance of your energy management setup.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSOLAX-CTSA016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 m (extendable up to 30 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 or 1.0 IEC 60044-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpoxy encapsulated, nylon case (UL94 V-0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eETL, RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Solax","offers":[{"title":"Default Title","offer_id":58693526978909,"sku":"CTSA016 100A","price":59.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SOLAX-CTSA016CTClamp.png?v=1763485933"},{"product_id":"solax-m3-40-three-phase-ct-energy-meter","title":"SolaX M3-40 3-Phase CT Energy Meter | 100A\/40mA CTs | RS485","description":"\u003c!-- SEO Product Name: SolaX M3-40 3-Phase CT Energy Meter | 100A\/40mA CTs | RS485 --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#2B2B2B; line-height:1.6; font-family:Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eThe \u003cstrong\u003eSolaX M3-40\u003c\/strong\u003e is a \u003cstrong\u003ethree-phase indirect (CT-connected) energy meter\u003c\/strong\u003e for homes and businesses. It measures \u003cstrong\u003evoltage, current, power and frequency\u003c\/strong\u003e on \u003cstrong\u003e3P3W and 3P4W\u003c\/strong\u003e supplies and sends the readings to your SolaX inverter, so the system can \u003cstrong\u003emanage battery charging, limit export and show self-consumption\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eThis pack includes a set of \u003cstrong\u003e100A\/40mA CTs\u003c\/strong\u003e and a \u003cstrong\u003e5m communication cable\u003c\/strong\u003e, giving a \u003cstrong\u003eplug-and-play CT solution\u003c\/strong\u003e. A \u003cstrong\u003e50ms refresh rate\u003c\/strong\u003e gives fast, precise control, \u003cstrong\u003eintelligent phase sequence and CT direction adjustment\u003c\/strong\u003e automatically resolves installation errors, and settings can be changed remotely from the \u003cstrong\u003eSolaXCloud app\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eIt is \u003cstrong\u003e45mm wide\u003c\/strong\u003e and mounts on a \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e inside the distribution board. It connects to the inverter over \u003cstrong\u003eRS485\u003c\/strong\u003e, or wirelessly through a SolaX \u003cstrong\u003eWi-BR\u003c\/strong\u003e bridge (sold separately), and works with a wide range of \u003cstrong\u003esingle-phase and three-phase\u003c\/strong\u003e SolaX inverters, including the \u003cstrong\u003eX3-MEGA G2\u003c\/strong\u003e, \u003cstrong\u003eX3-FORTH\u003c\/strong\u003e and \u003cstrong\u003eX3-ULTRA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:20px 0 24px 0;\"\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e3P3W \/ 3P4W\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; letter-spacing:.02em;\"\u003eThree-Phase Grid\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e100A\/40mA\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; letter-spacing:.02em;\"\u003eCTs Supplied\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e50ms\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; letter-spacing:.02em;\"\u003eRefresh Rate\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eClass 0.5\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; letter-spacing:.02em;\"\u003eVoltage \u0026amp; Current\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e45mm\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; letter-spacing:.02em;\"\u003eDIN-Rail Width\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eRS485\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; letter-spacing:.02em;\"\u003eInverter Link\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E6F4F3; border-left:4px solid #008377CF; border-radius:6px; padding:14px 18px; margin:0 0 20px 0;\"\u003e\n\u003cdiv style=\"font-size:14px; font-weight:700; color:#008377CF; text-transform:uppercase; letter-spacing:.04em; margin-bottom:6px;\"\u003eSingle-Phase Inverters Too\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px; color:#2B2B2B; line-height:1.6;\"\u003eThe M3-40 also works with SolaX \u003cstrong\u003esingle-phase\u003c\/strong\u003e inverters. In that case connect the voltage cables to the \u003cstrong\u003eL1 and N\u003c\/strong\u003e terminals, as set out in the SolaX quick installation guide.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFF6E5; border-left:4px solid #E0942A; border-radius:6px; padding:14px 18px; margin:0 0 20px 0;\"\u003e\n\u003cdiv style=\"font-size:14px; font-weight:700; color:#E0942A; text-transform:uppercase; letter-spacing:.04em; margin-bottom:6px;\"\u003eUse 40mA-Output CTs\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px; color:#2B2B2B; line-height:1.6;\"\u003eSolaX M-series meters take \u003cstrong\u003e40mA-output CTs\u003c\/strong\u003e. The CHINT DTSU666-CT meters use a different type, \u003cstrong\u003e5A-output CTs\u003c\/strong\u003e, and the two types are \u003cstrong\u003enot interchangeable\u003c\/strong\u003e. This pack includes 100A\/40mA CTs. For larger supplies SolaX makes 200A, 400A and 600A 3-in-1 CT sets, sold separately.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FDECEC; border-left:4px solid #D32F2F; border-radius:6px; padding:14px 18px; margin:0 0 20px 0;\"\u003e\n\u003cdiv style=\"font-size:14px; font-weight:700; color:#D32F2F; text-transform:uppercase; letter-spacing:.04em; margin-bottom:6px;\"\u003eImportant Safety Information\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px; color:#2B2B2B; line-height:1.6;\"\u003eInstallation must be carried out by a \u003cstrong\u003equalified electrician\u003c\/strong\u003e to \u003cstrong\u003eBS 7671\u003c\/strong\u003e, with the supply isolated before any wiring is done. Connect the voltage and CT wires exactly as shown in the \u003cstrong\u003eSolaX quick installation guide\u003c\/strong\u003e and fit the CT around the correct conductor. Terminal screws are tightened to \u003cstrong\u003e0.45 N·m\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 0 24px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003ePlug-and-Play CTs\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#444444; line-height:1.6;\"\u003eA set of \u003cstrong\u003e100A\/40mA CTs (2m leads)\u003c\/strong\u003e and a \u003cstrong\u003e5m COM cable\u003c\/strong\u003e are in the pack.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003e50ms Refresh\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#444444; line-height:1.6;\"\u003eA \u003cstrong\u003e50ms refresh rate\u003c\/strong\u003e supports more precise and faster control of storage and export.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eAutomatic Phase \u0026amp; CT Correction\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#444444; line-height:1.6;\"\u003e\n\u003cstrong\u003eIntelligent adjustment\u003c\/strong\u003e of phase sequence and CT direction \u003cstrong\u003eautomatically resolves installation issues\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eRemote Settings\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#444444; line-height:1.6;\"\u003eChange settings remotely through the \u003cstrong\u003eSolaXCloud app\u003c\/strong\u003e, saving a return visit.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eSafe Isolation\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#444444; line-height:1.6;\"\u003e\n\u003cstrong\u003eSeparates strong and weak currents\u003c\/strong\u003e for enhanced electrical safety.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eWired or Wireless\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#444444; line-height:1.6;\"\u003e\n\u003cstrong\u003eRS485\u003c\/strong\u003e by RJ45 or screw terminal, or wireless through a \u003cstrong\u003eWi-BR\u003c\/strong\u003e bridge (sold separately).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; overflow:hidden; margin:0 0 24px 0; overflow-x:auto;\"\u003e\n\u003cdiv style=\"display:flex; background:#008377CF;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:12px; font-weight:700; color:#ffffff; text-transform:uppercase; letter-spacing:.04em;\"\u003eSupply\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:12px; font-weight:700; color:#ffffff; text-transform:uppercase; letter-spacing:.04em;\"\u003eInverter Series\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:12px; font-weight:700; color:#ffffff; text-transform:uppercase; letter-spacing:.04em;\"\u003eConnection\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:12px; font-weight:700; color:#ffffff; text-transform:uppercase; letter-spacing:.04em;\"\u003eRS485 A \/ B Pins\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eThree-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX3-HYB G4, X3-FIT G4, X3-IES\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eRJ45\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e4 \/ 5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eThree-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX3-HYB G4 PRO, X3-AELIO\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eRJ45\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e4 \/ 5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eThree-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX3-ULTRA\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eRJ45\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e4 \/ 5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eThree-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX3-MIC G2\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eRJ45\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e4 \/ 5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eThree-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX3-PRO G2\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eO\/I terminal\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e5 \/ 6\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eThree-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX3-MEGA G2, X3-FORTH\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eQuick-connect terminal\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e7 \/ 8\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eSingle-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX1-HYB G4, X1-FIT G4, X1-IES, X1-VAST\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eRJ45\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e4 \/ 5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eSingle-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX1-MINI G4, X1-BOOST G4\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eRJ45\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e4 \/ 5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eSingle-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX1-HYB LV\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eRJ45\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e4 \/ 5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eSingle-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX1-AC\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eRJ45\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e7 \/ 8\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eSingle-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX1-SMART G2\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eQuick-connect terminal\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e4 \/ 5 or 11 \/ 12\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E6F4F3; border-left:4px solid #008377CF; border-radius:6px; padding:14px 18px; margin:0 0 20px 0;\"\u003e\n\u003cdiv style=\"font-size:14px; font-weight:700; color:#008377CF; text-transform:uppercase; letter-spacing:.04em; margin-bottom:6px;\"\u003eAbout the Pin Numbers\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px; color:#2B2B2B; line-height:1.6;\"\u003ePins are the inverter's \u003cstrong\u003e485A \/ 485B\u003c\/strong\u003e terminals. On the \u003cstrong\u003eX1-SMART G2\u003c\/strong\u003e two pairs of terminals are available and the two pins in the same box are a pair. For single-phase inverters, wire the voltage cables to \u003cstrong\u003eL1 and N\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; overflow:hidden; margin:0 0 24px 0;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; font-size:12px; letter-spacing:.06em; text-transform:uppercase; padding:9px 14px;\"\u003eElectrical\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003ePower grid type\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e3P3W \/ 3P4W\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eRated voltage\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e3 x 220\/380V to 3 x 240\/415V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eOperating voltage\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e100 to 280V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eCurrent input\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e*A \/ 40mA (via CTs)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eFrequency\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e45 to 65Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eFrequency tolerance\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e0.01Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; font-size:12px; letter-spacing:.06em; text-transform:uppercase; padding:9px 14px;\"\u003eMeasurement\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eAccuracy, voltage and current\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eClass 0.5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eAccuracy, active power\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eClass 1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eAccuracy, reactive power\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eClass 2\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eResolution\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eActive power 0.1W, frequency 0.001Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eRefresh rate\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e50ms\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eCTs supplied\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e100A\/40mA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eRecommended CT range (SolaX)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e100A\/40mA up to 2000A\/40mA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; font-size:12px; letter-spacing:.06em; text-transform:uppercase; padding:9px 14px;\"\u003eCommunication\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eWired\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eRS485, by RJ45 or screw terminal\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eWireless\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eSolaX Wi-BR bridge (sold separately), up to 200m horizontal and 20m vertical in SolaX lab tests\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; font-size:12px; letter-spacing:.06em; text-transform:uppercase; padding:9px 14px;\"\u003eEnvironment \u0026amp; Mechanical\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eOperating temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e-40 to 70°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eOperating humidity\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e95% RH or below (non-condensing)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eOperating altitude\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eBelow 4,000m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eDegree of protection\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eIP20\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eDimensions (W x H x D)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e45 x 100 x 65.5mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eMounting\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e35mm DIN rail, inside the distribution board\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; font-size:12px; letter-spacing:.06em; text-transform:uppercase; padding:9px 14px;\"\u003eCables \u0026amp; Contents\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eVoltage cable (installer supplied)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eMulti-core copper, 1.5 to 2.5mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eCOM cable\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eShielded twisted pair, 0.25 to 1.5mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eTerminal screw torque\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e0.45 N·m (M2), 7mm strip length\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eIn the pack\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eM3-40 meter, CT set (2m leads), 5m COM cable, 4-pin terminal block, document\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px; font-size:15px; font-weight:700; color:#ffffff; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#008377CF;\"\u003e\u003cspan\u003eWhat does the M3-40 do?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#ffffff\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px 18px; font-size:14px; color:#444444; line-height:1.65; border-top:1px solid #D9EDEA; background:#ffffff;\"\u003eIt measures the electricity flowing at the \u003cstrong\u003egrid connection point\u003c\/strong\u003e of a three-phase supply and reports it to the SolaX inverter, which uses it to \u003cstrong\u003econtrol battery charging, limit export and track self-consumption\u003c\/strong\u003e.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px; font-size:15px; font-weight:700; color:#ffffff; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#008377CF;\"\u003e\u003cspan\u003eDo I need a meter for export control on a three-phase inverter?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#ffffff\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px 18px; font-size:14px; color:#444444; line-height:1.65; border-top:1px solid #D9EDEA; background:#ffffff;\"\u003eSolaX's knowledge base states that a \u003cstrong\u003emeter or CT is needed for export control\u003c\/strong\u003e, and that \u003cstrong\u003ethree-phase on-grid inverters work with a meter rather than a CT\u003c\/strong\u003e. Confirm the arrangement for your inverter with SolaX.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px; font-size:15px; font-weight:700; color:#ffffff; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#008377CF;\"\u003e\u003cspan\u003eWhich SolaX inverters does it work with?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#ffffff\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px 18px; font-size:14px; color:#444444; line-height:1.65; border-top:1px solid #D9EDEA; background:#ffffff;\"\u003eThe \u003cstrong\u003eX3-HYB G4, X3-FIT G4, X3-IES, X3-HYB G4 PRO, X3-AELIO, X3-ULTRA, X3-MIC G2, X3-PRO G2, X3-MEGA G2 and X3-FORTH\u003c\/strong\u003e, and the single-phase \u003cstrong\u003eX1\u003c\/strong\u003e models listed in the table. The table gives the RS485 pins for each.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px; font-size:15px; font-weight:700; color:#ffffff; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#008377CF;\"\u003e\u003cspan\u003eCan I use it on a single-phase system?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#ffffff\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px 18px; font-size:14px; color:#444444; line-height:1.65; border-top:1px solid #D9EDEA; background:#ffffff;\"\u003eYes. SolaX's quick guide allows single-phase inverters, with the voltage cables wired to \u003cstrong\u003eL1 and N\u003c\/strong\u003e. If you only ever need single-phase, the \u003cstrong\u003eM1-40\u003c\/strong\u003e is the narrower, single-CT option.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px; font-size:15px; font-weight:700; color:#ffffff; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#008377CF;\"\u003e\u003cspan\u003eWhich CTs do I need?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#ffffff\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px 18px; font-size:14px; color:#444444; line-height:1.65; border-top:1px solid #D9EDEA; background:#ffffff;\"\u003eA set of \u003cstrong\u003e100A\/40mA CTs\u003c\/strong\u003e is included. SolaX lists recommended CT ratings from \u003cstrong\u003e100A\/40mA up to 2000A\/40mA\u003c\/strong\u003e, and offers 200A, 400A and 600A 3-in-1 sets separately. Use 40mA-output CTs only.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px; font-size:15px; font-weight:700; color:#ffffff; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#008377CF;\"\u003e\u003cspan\u003eWhere does it go in the system?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#ffffff\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px 18px; font-size:14px; color:#444444; line-height:1.65; border-top:1px solid #D9EDEA; background:#ffffff;\"\u003eInstall it between the \u003cstrong\u003egrid and all home loads\u003c\/strong\u003e, normally in the main distribution board on a \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e. Connect all cables before mounting it on the rail.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Solax","offers":[{"title":"Default Title","offer_id":58693527077213,"sku":"M3-40","price":139.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SolaxM1-40SinglePhase100ACTEnergyMeter.avif?v=1761588109"},{"product_id":"solax-m1-40-single-phase-ct-energy-meter","title":"SolaX M1-40 1-Phase CT Energy Meter | 100A\/40mA CT | RS485","description":"\u003c!-- SEO Product Name: SolaX M1-40 1-Phase CT Energy Meter | 100A\/40mA CT | RS485 --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#2B2B2B; line-height:1.6; font-family:Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eThe \u003cstrong\u003eSolaX M1-40\u003c\/strong\u003e is a \u003cstrong\u003esingle-phase indirect (CT-connected) energy meter\u003c\/strong\u003e for homes and small businesses. It measures \u003cstrong\u003evoltage, current, power and frequency\u003c\/strong\u003e at the grid connection point and sends the readings to your SolaX inverter, so the system can \u003cstrong\u003emanage battery charging, limit export and show self-consumption\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eThis pack includes a \u003cstrong\u003e100A\/40mA CT on a 2m lead\u003c\/strong\u003e and a \u003cstrong\u003e5m communication cable\u003c\/strong\u003e, making it a \u003cstrong\u003eplug-and-play CT solution\u003c\/strong\u003e. A \u003cstrong\u003e50ms refresh rate\u003c\/strong\u003e gives fast, precise control, \u003cstrong\u003eintelligent CT direction adjustment\u003c\/strong\u003e automatically resolves installation errors, and settings can be changed remotely from the \u003cstrong\u003eSolaXCloud app\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eAt only \u003cstrong\u003e18mm wide\u003c\/strong\u003e it clips onto a \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e inside the distribution board. It talks to the inverter over \u003cstrong\u003eRS485\u003c\/strong\u003e, or wirelessly through a SolaX \u003cstrong\u003eWi-BR\u003c\/strong\u003e bridge (sold separately), and it offers \u003cstrong\u003eClass 0.5\u003c\/strong\u003e voltage and current accuracy across a \u003cstrong\u003e-40°C to 70°C\u003c\/strong\u003e operating range.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:20px 0 24px 0;\"\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e1P2W\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; letter-spacing:.02em;\"\u003eSingle-Phase Grid\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e100A\/40mA\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; letter-spacing:.02em;\"\u003eCT Supplied\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e50ms\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; letter-spacing:.02em;\"\u003eRefresh Rate\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eClass 0.5\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; letter-spacing:.02em;\"\u003eVoltage \u0026amp; Current\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e18mm\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; letter-spacing:.02em;\"\u003eDIN-Rail Width\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eRS485\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; font-weight:400; margin-top:4px; letter-spacing:.02em;\"\u003eInverter Link\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFF6E5; border-left:4px solid #E0942A; border-radius:6px; padding:14px 18px; margin:0 0 20px 0;\"\u003e\n\u003cdiv style=\"font-size:14px; font-weight:700; color:#E0942A; text-transform:uppercase; letter-spacing:.04em; margin-bottom:6px;\"\u003eSingle-Phase Supplies Only\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px; color:#2B2B2B; line-height:1.6;\"\u003eThe M1-40 is for \u003cstrong\u003esingle-phase\u003c\/strong\u003e connections (\u003cstrong\u003e1P2W, 220 to 240V\u003c\/strong\u003e). For a three-phase supply use the \u003cstrong\u003eM3-40\u003c\/strong\u003e or \u003cstrong\u003eM3-40-Dual\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFF6E5; border-left:4px solid #E0942A; border-radius:6px; padding:14px 18px; margin:0 0 20px 0;\"\u003e\n\u003cdiv style=\"font-size:14px; font-weight:700; color:#E0942A; text-transform:uppercase; letter-spacing:.04em; margin-bottom:6px;\"\u003eUse 40mA-Output CTs\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px; color:#2B2B2B; line-height:1.6;\"\u003eSolaX M-series meters take \u003cstrong\u003e40mA-output CTs\u003c\/strong\u003e. The CHINT DTSU666-CT meters use a different type, \u003cstrong\u003e5A-output CTs\u003c\/strong\u003e, and the two types are \u003cstrong\u003enot interchangeable\u003c\/strong\u003e. The pack CT is 100A\/40mA, which is SolaX's recommended rating for this meter.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FDECEC; border-left:4px solid #D32F2F; border-radius:6px; padding:14px 18px; margin:0 0 20px 0;\"\u003e\n\u003cdiv style=\"font-size:14px; font-weight:700; color:#D32F2F; text-transform:uppercase; letter-spacing:.04em; margin-bottom:6px;\"\u003eImportant Safety Information\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px; color:#2B2B2B; line-height:1.6;\"\u003eInstallation must be carried out by a \u003cstrong\u003equalified electrician\u003c\/strong\u003e to \u003cstrong\u003eBS 7671\u003c\/strong\u003e, with the supply isolated before any wiring is done. Connect the voltage and CT wires exactly as shown in the \u003cstrong\u003eSolaX quick installation guide\u003c\/strong\u003e and fit the CT around the correct conductor. Terminal screws are tightened to \u003cstrong\u003e0.45 N·m\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 0 24px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003ePlug-and-Play CT\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#444444; line-height:1.6;\"\u003eA \u003cstrong\u003e100A\/40mA CT (2m lead)\u003c\/strong\u003e and a \u003cstrong\u003e5m COM cable\u003c\/strong\u003e are in the pack, so no extra parts are needed for a standard install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003e50ms Refresh\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#444444; line-height:1.6;\"\u003eA \u003cstrong\u003e50ms refresh rate\u003c\/strong\u003e supports more precise and faster control of storage and export.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eAutomatic CT Direction\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#444444; line-height:1.6;\"\u003e\n\u003cstrong\u003eIntelligent adjustment\u003c\/strong\u003e of CT direction \u003cstrong\u003eautomatically resolves installation issues\u003c\/strong\u003e if a CT is fitted the wrong way round.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eRemote Settings\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#444444; line-height:1.6;\"\u003eChange settings remotely through the \u003cstrong\u003eSolaXCloud app\u003c\/strong\u003e, saving a return visit.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eSafe Isolation\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#444444; line-height:1.6;\"\u003e\n\u003cstrong\u003eSeparates strong and weak currents\u003c\/strong\u003e for enhanced electrical safety.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:15px; font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eCompact DIN-Rail Unit\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#444444; line-height:1.6;\"\u003eJust \u003cstrong\u003e18mm wide\u003c\/strong\u003e on a \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e, with a \u003cstrong\u003edisplay\u003c\/strong\u003e and a button to switch between readings.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; overflow:hidden; margin:0 0 24px 0; overflow-x:auto;\"\u003e\n\u003cdiv style=\"display:flex; background:#008377CF;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:12px; font-weight:700; color:#ffffff; text-transform:uppercase; letter-spacing:.04em;\"\u003eSupply\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:12px; font-weight:700; color:#ffffff; text-transform:uppercase; letter-spacing:.04em;\"\u003eInverter Series\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:12px; font-weight:700; color:#ffffff; text-transform:uppercase; letter-spacing:.04em;\"\u003eConnection\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:12px; font-weight:700; color:#ffffff; text-transform:uppercase; letter-spacing:.04em;\"\u003eRS485 A \/ B Pins\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eSingle-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX1-HYB G4, X1-FIT G4, X1-IES, X1-VAST\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eRJ45\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e4 \/ 5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eSingle-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX1-MINI G4, X1-BOOST G4\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eRJ45\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e4 \/ 5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eSingle-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX1-HYB LV\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eRJ45\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e4 \/ 5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eSingle-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX1-AC\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eRJ45\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e7 \/ 8\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8;\"\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eSingle-phase\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eX1-SMART G2\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003eQuick-connect terminal\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 12px; font-size:14px; color:#222222; border-bottom:1px solid #D9EDEA;\"\u003e4 \/ 5 or 11 \/ 12\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E6F4F3; border-left:4px solid #008377CF; border-radius:6px; padding:14px 18px; margin:0 0 20px 0;\"\u003e\n\u003cdiv style=\"font-size:14px; font-weight:700; color:#008377CF; text-transform:uppercase; letter-spacing:.04em; margin-bottom:6px;\"\u003eAbout the Pin Numbers\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px; color:#2B2B2B; line-height:1.6;\"\u003ePins are the inverter's \u003cstrong\u003e485A \/ 485B\u003c\/strong\u003e terminals. On the \u003cstrong\u003eX1-SMART G2\u003c\/strong\u003e two pairs of terminals are available and the two pins in the same box are a pair. Wiring for each inverter is in the SolaX quick installation guide.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; overflow:hidden; margin:0 0 24px 0;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; font-size:12px; letter-spacing:.06em; text-transform:uppercase; padding:9px 14px;\"\u003eElectrical\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003ePower grid type\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e1P2W\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eRated voltage\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e220 to 240V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eOperating voltage\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e100 to 288V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eCurrent input\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e*A \/ 40mA (via CT)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eFrequency\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e45 to 65Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eFrequency tolerance\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e0.01Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; font-size:12px; letter-spacing:.06em; text-transform:uppercase; padding:9px 14px;\"\u003eMeasurement\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eAccuracy, voltage and current\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eClass 0.5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eAccuracy, active power\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eClass 1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eAccuracy, reactive power\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eClass 2\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eResolution\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eActive power 0.1W, frequency 0.001Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eRefresh rate\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e50ms\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eCT supplied\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e100A\/40mA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eOther CT rating listed by SolaX\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e200A\/40mA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; font-size:12px; letter-spacing:.06em; text-transform:uppercase; padding:9px 14px;\"\u003eCommunication\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eWired\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eRS485\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eWireless\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eSolaX Wi-BR bridge (sold separately), up to 200m horizontal and 20m vertical in SolaX lab tests\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; font-size:12px; letter-spacing:.06em; text-transform:uppercase; padding:9px 14px;\"\u003eEnvironment \u0026amp; Mechanical\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eOperating temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e-40 to 70°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eOperating humidity\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e95% RH or below (non-condensing)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eOperating altitude\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eBelow 4,000m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eDegree of protection\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eIP20\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eDimensions (W x H x D)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e18 x 100 x 65.5mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eMounting\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e35mm DIN rail, inside the distribution board\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; font-size:12px; letter-spacing:.06em; text-transform:uppercase; padding:9px 14px;\"\u003eCables \u0026amp; Contents\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eVoltage cable (installer supplied)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eMulti-core copper, 1.5 to 2.5mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eCOM cable\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eShielded twisted pair, 0.25 to 1.5mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F0F9F8; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eTerminal screw torque\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003e0.45 N·m (M2), 7mm strip length\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 44%; padding:10px 14px; font-size:14px; font-weight:600; color:#333333;\"\u003eIn the pack\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:10px 14px; font-size:14px; color:#222222;\"\u003eM1-40 meter, 1 CT (2m lead), 5m COM cable, document\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px; font-size:15px; font-weight:700; color:#ffffff; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#008377CF;\"\u003e\u003cspan\u003eWhat does the M1-40 do?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#ffffff\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px 18px; font-size:14px; color:#444444; line-height:1.65; border-top:1px solid #D9EDEA; background:#ffffff;\"\u003eIt measures the electricity flowing at the \u003cstrong\u003egrid connection point\u003c\/strong\u003e and reports it to the SolaX inverter. The inverter uses this to \u003cstrong\u003econtrol battery charging, limit export and track self-consumption\u003c\/strong\u003e. SolaX's knowledge base states that a meter or CT is needed for export control.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px; font-size:15px; font-weight:700; color:#ffffff; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#008377CF;\"\u003e\u003cspan\u003eIs it for single-phase or three-phase?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#ffffff\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px 18px; font-size:14px; color:#444444; line-height:1.65; border-top:1px solid #D9EDEA; background:#ffffff;\"\u003e\n\u003cstrong\u003eSingle-phase only\u003c\/strong\u003e (1P2W, 220 to 240V). For three-phase supplies, see the \u003cstrong\u003eM3-40\u003c\/strong\u003e and \u003cstrong\u003eM3-40-Dual\u003c\/strong\u003e.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px; font-size:15px; font-weight:700; color:#ffffff; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#008377CF;\"\u003e\u003cspan\u003eWhich SolaX inverters can I connect it to?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#ffffff\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px 18px; font-size:14px; color:#444444; line-height:1.65; border-top:1px solid #D9EDEA; background:#ffffff;\"\u003eThe \u003cstrong\u003esingle-phase X1 series\u003c\/strong\u003e: X1-HYB G4, X1-FIT G4, X1-IES, X1-VAST, X1-MINI G4, X1-BOOST G4, X1-HYB LV, X1-AC and X1-SMART G2. The table above gives the RS485 pins for each.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px; font-size:15px; font-weight:700; color:#ffffff; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#008377CF;\"\u003e\u003cspan\u003eWhich CT do I need?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#ffffff\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px 18px; font-size:14px; color:#444444; line-height:1.65; border-top:1px solid #D9EDEA; background:#ffffff;\"\u003eA \u003cstrong\u003e100A\/40mA CT\u003c\/strong\u003e is included and is SolaX's recommended rating for this meter. SolaX's quick guide also lists a \u003cstrong\u003e200A\/40mA\u003c\/strong\u003e CT. Confirm any other rating with SolaX before ordering.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px; font-size:15px; font-weight:700; color:#ffffff; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#008377CF;\"\u003e\u003cspan\u003eWhere does it go in the system?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#ffffff\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px 18px; font-size:14px; color:#444444; line-height:1.65; border-top:1px solid #D9EDEA; background:#ffffff;\"\u003eInstall it between the \u003cstrong\u003egrid and all home loads\u003c\/strong\u003e, normally in the main distribution board, on a \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e. Connect all cables before mounting it on the rail.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding:14px 18px; font-size:15px; font-weight:700; color:#ffffff; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#008377CF;\"\u003e\u003cspan\u003eCan it work wirelessly?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#ffffff\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px 16px 18px; font-size:14px; color:#444444; line-height:1.65; border-top:1px solid #D9EDEA; background:#ffffff;\"\u003eYes, with a SolaX \u003cstrong\u003eWi-BR\u003c\/strong\u003e wireless bridge (sold separately). SolaX quotes up to \u003cstrong\u003e200m horizontally and 20m vertically\u003c\/strong\u003e from its own lab tests, so real-world range depends on the building.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Solax","offers":[{"title":"Default Title","offer_id":58693527404893,"sku":"M1-40","price":63.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SolaxM1SinglePhaseCTEnergyMeter.jpg?v=1761587848"},{"product_id":"sdm230-single-phase-modbus-meter-for-solax-x1-100a-direct-connection","title":"SDM230 single-phase Modbus Meter for Solax X1 100A Direct Connection","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Phase Meter:\u003c\/strong\u003e Designed for accurate energy monitoring in single-phase electrical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus Communication:\u003c\/strong\u003e Equipped with Modbus RTU protocol over RS485 for seamless integration with Solax X1 inverters and other energy management systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Connection:\u003c\/strong\u003e Supports up to 100A direct connection without the need for current transformers, simplifying installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounted:\u003c\/strong\u003e Compact size for easy mounting on standard DIN rails in electrical panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultifunction Display:\u003c\/strong\u003e Shows voltage, current, power, energy consumption, and power factor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Logging Compatible:\u003c\/strong\u003e Enables detailed energy usage analysis and efficient system monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Voltage \u0026amp; Frequency Range:\u003c\/strong\u003e Operates reliably with 230V AC, frequency 50\/60Hz power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Buy This Meter?\u003c\/h3\u003e\n\u003cp\u003eThis SDM230 Modbus meter is ideal for precise energy monitoring and control in residential and small commercial solar PV systems, especially when paired with Solax X1 inverters. Its direct 100A connection reduces complexity and cost, while Modbus communication enables integration into smart energy management platforms for optimisation and data-driven decisions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSDM230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100A (Direct Connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus RTU over RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail 35mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, Active Power, Energy, Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Eastron","offers":[{"title":"Default Title","offer_id":58693528715613,"sku":"SDM230-MODBUS","price":120.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/eastron-SDM230-modbus.jpg?v=1763485387"},{"product_id":"givenergy-programmable-single-phase-energy-meter-with-ct","title":"GivEnergy Programmable Single Phase  Modbus Energy Meter with CT","description":"\u003cdiv class=\"tab-pane fade show active clearfix\" id=\"overview\" role=\"tabpanel\" aria-labelledby=\"overviewTab\"\u003e\n\u003cdiv class=\"mb-3\"\u003e\n\u003ch3 dir=\"auto\"\u003eGivEnergy GEM120CT Programmable Modbus Energy Meter 1ph 1m\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eExplore the GivEnergy GEM120CT Programmable Modbus Energy Meter 1ph 1m, an advanced single-phase monitoring device engineered by GivEnergy for precise energy tracking in homes and businesses. This compact, CT-operated kWh meter delivers bi-directional measurement, enabling accurate assessment of grid import and export, PV generation, and various household loads to optimise energy efficiency and reduce costs. With its Modbus output, the GEM120CT seamlessly integrates with GivEnergy inverters and energy management systems, offering programmable ratios for flexible current adaptation up to 100A.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eFeaturing a backlit three-line LCD display for clear data visibility and an addressable ID configurable via the front panel (ID1 for grid, ID2\/ID3 for PV), this meter supports multi-faceted monitoring without complexity. MID-approved for reliability in billing applications, it includes EEPROM memory for data retention and IP51 protection against particles and moisture, ensuring durable performance in diverse environments. Ideal for solar PV installations, battery storage setups, and general power metering, the GivEnergy GEM120CT promotes sustainable energy practices, compliance with regulations, and informed decision-making for smarter home energy management.\u003c\/p\u003e\n\u003ch4 dir=\"auto\"\u003eTechnical Specifications\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eKit Components\u003c\/strong\u003e: Includes single-phase energy meter, 100A CT clamp with 2m reach, and programmable Modbus interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Works with GivEnergy inverters and systems; suitable for single-phase monitoring, PV generation, grid import\/export, and home load aggregation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaning Capability\u003c\/strong\u003e: N\/A (energy monitoring device)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection Capability\u003c\/strong\u003e: Bi-directional energy measurement; programmable CT ratio; 100A maximum current; direct\/split CT connection; Modbus communication protocol\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBenefits\u003c\/strong\u003e: Enhances energy efficiency, supports MID-approved accuracy for billing, enables flexible ID configuration (ID1\/ID2\/ID3), reduces installation time with compact design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty\u003c\/strong\u003e: 2 years (as standard from manufacturer)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Features\u003c\/strong\u003e: Backlit three-line LCD display; compact DIN-rail mounting (dimensions: 119mm H x 17.5mm W x 62mm D); IP51 protection rating; EEPROM memory for data storage; operating temperature -25°C to 55°C; front panel setup for easy configuration; British-made quality for reliable performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Modbus I.D of the meter comes preset as ID1 but provides functionality to be addressed under 3 different Modbus IDs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eID1 - Import and Export meter\u003c\/li\u003e\n\u003cli\u003eID2\/3 - PV Monitoring meters\u003c\/li\u003e\n\u003cli\u003e45\/100 = 45A In-Line connected meter with a 100A CT\u003c\/li\u003e\n\u003cli\u003eProtection Class IP51\u003c\/li\u003e\n\u003cli\u003eCT cable length - 200cm\u003c\/li\u003e\n\u003cli\u003eDimensions (HxWxD) 119 x 17.5 x 62mm\u003c\/li\u003e\n\u003cli\u003eWith bi-directional energy measurement\u003c\/li\u003e\n\u003cli\u003eThis meter is ideal for Solar PV energy metering\u003c\/li\u003e\n\u003cli\u003eDirect\/CT connection and solid or split CT options\u003c\/li\u003e\n\u003cli\u003eLCD display with clear green backlight\u003c\/li\u003e\n\u003cli\u003e50 Pulse output\u003c\/li\u003e\n\u003cli\u003e1,2,3 and 4 tariff meter option\u003c\/li\u003e\n\u003cli\u003eAccuracy class B according to EN50470-3\u003c\/li\u003e\n\u003cli\u003eAccuracy class 1 according to IEC62053-21\u003c\/li\u003e\n\u003cli\u003eEEprom memory backup\u003c\/li\u003e\n\u003cli\u003eImport \/ Export \/ Generation and Consumption\u003c\/li\u003e\n\u003cli\u003eNET Metering to comply with OFGEM regulations on Co-located Storage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"GivEnergy","offers":[{"title":"Default Title","offer_id":58693535007069,"sku":"GIV-GM120CT-P","price":47.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/GivenergyMeterGIV-GEM120CT.jpg?v=1761586243"},{"product_id":"emlite-single-phase-total-generation-meter-100a-with-pulse-output-inc-cover","title":"Emlite ECA2.V Single Phase 100A Generation Meter Pulse Output 1000\/kWh MID Approved Solar PV FiT SEG with Cover","description":"\u003cdiv style=\"font-size: 16px; font-family: Arial,Helvetica,sans-serif; color: #1a1a1a; max-width: 900px; margin: 0 auto; line-height: 1.6;\"\u003e\n\u003cp style=\"margin: 0 0 18px;\"\u003eThe \u003cstrong\u003eEmlite ECA2.V\u003c\/strong\u003e is a \u003cstrong\u003esingle-phase, direct-connect 100A MID-approved electricity meter with 1000 pulse\/kWh output\u003c\/strong\u003e, supplied with an extended terminal cover. It is one of the most widely installed generation meters in UK solar PV installations, used for \u003cstrong\u003eMCS commissioning sign-off, SEG and FiT generation verification, and single-phase sub-metering\u003c\/strong\u003e up to 100A. The meter measures active energy (kWh) in both import and export directions, displaying registers on an 8-character auto-cycling LCD. The extended cover provides additional wiring space at the terminals — essential in consumer unit enclosures where PV tails run alongside other cabling. Fully \u003cstrong\u003eMID approved to Class B (1%) per EN 50470-1\/3\u003c\/strong\u003e. One of the world's most compact single-phase metering units at 91 × 125 × 40mm.\u003c\/p\u003e\n\u003cdiv style=\"border-left: 4px solid #008377CF; background: #e6f4f3; padding: 10px 16px; margin-bottom: 22px; border-radius: 0 6px 6px 0;\"\u003e\n\u003cstrong style=\"color: #005c54;\"\u003eℹ ECA2.V — Total Generation Mode Explained\u003c\/strong\u003e\u003cbr\u003eThe ECA2.V measures the \u003cstrong\u003etotal electrical output of the generation source as a cumulative kWh figure\u003c\/strong\u003e — it does not distinguish between energy consumed in the property and energy exported to the grid. This is the correct meter for \u003cstrong\u003eMCS commissioning, FiT generation tariff claims, and SEG agreements on PV-only systems\u003c\/strong\u003e. For systems with battery storage where a net export figure is required, use the bi-directional ECA2 variant instead.\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: 600; font-size: 15px; padding: 10px 16px; border-radius: 6px 6px 0 0;\"\u003eFeatures \u0026amp; Benefits\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(255px,1fr)); gap: 12px; background: #e6f4f3; padding: 14px; border-radius: 0 0 6px 6px; margin-bottom: 22px;\"\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ MID Approved — Legal for Billing \u0026amp; MCS Sign-Off\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong\u003eMID (Measuring Instruments Directive 2004\/22\/EC)\u003c\/strong\u003e approval certifies a meter's accuracy for trade, billing, and official use. For solar PV installations in the UK, a \u003cstrong\u003eMID-approved generation meter is required by DNOs and MCS\u003c\/strong\u003e as the legally valid measurement of exported or generated electricity — a non-MID meter cannot be used for SEG payments, FiT legacy claims, or MCS commissioning sign-off. The Emlite meters carry full MID approval to Class B (1% accuracy, EN 50470-1\/3), satisfying all DNO and MCS submission requirements.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ 1000 Pulse\/kWh — Energy Monitor Integration\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eThe \u003cstrong\u003e1000 pulse per kWh opto-isolated output\u003c\/strong\u003e on the auxiliary terminals feeds real-time energy data into \u003cstrong\u003eenergy management systems, BMS, AMR data loggers, and smart home platforms\u003c\/strong\u003e. Each pulse represents 1Wh — at 1000 pulses\/kWh the resolution supports accurate sub-hourly monitoring. The output conforms to IEC 62053-31 and is electrically isolated, preventing ground-loop issues when connecting to third-party monitoring equipment. Compatible with GivEnergy, SolarEdge, Solis, Fox ESS, myenergi, and most modern inverter monitoring platforms.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ Ultra-Compact — 91 × 125 × 40mm\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eAt just \u003cstrong\u003e91mm tall × 125mm wide × 40mm deep\u003c\/strong\u003e, the ECA2 is one of the world's most compact MID-approved single-phase meters, making it practical in \u003cstrong\u003espace-constrained consumer units and meter boards\u003c\/strong\u003e. The extended terminal cover adds wiring space without significantly increasing board depth. Wide \u003cstrong\u003e–40°C to +70°C temperature range\u003c\/strong\u003e covers unheated outbuildings and garage boards. \u003cstrong\u003eIP52 ingress protection\u003c\/strong\u003e (BS EN 60529) for dust and drip resistance in indoor meter board locations.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ Optical Port — Tamper Resistant — Solid Brass Terminals\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eAn \u003cstrong\u003eoptical communications port\u003c\/strong\u003e (IEC 629056-21) enables electronic meter reading using a standard probe and software — useful for commissioning verification and commercial AMR reading. The meter is \u003cstrong\u003etamper resistant\u003c\/strong\u003e with reverse energy fraud detection and is sealed for life. \u003cstrong\u003eSolid brass cable terminals\u003c\/strong\u003e (8.2mm diameter) give robust, low-resistance connections at full 100A rating. The meter withstands \u003cstrong\u003ehigh-voltage events and 140% overcurrent\u003c\/strong\u003e without failure — important in grid-connected installations that may experience transients.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: 600; font-size: 15px; padding: 10px 16px; border-radius: 6px 6px 0 0;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 22px; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; width: 44%; border-bottom: 1px solid #c8e6e3;\"\u003eManufacturer \/ Model\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eEmlite — \u003cstrong\u003eECA2.V\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003ePhase\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eMeasurement\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eActive energy (kWh) — import and export registers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e220–240V AC; max 276V; withstand 415V (up to 6 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e50Hz ± 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eReference \/ Max Current\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eIref 5–20A; \u003cstrong\u003eImax 100A\u003c\/strong\u003e (140% overcurrent rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003eClass B (1%)\u003c\/strong\u003e — EN 50470-1\/3; fully MID approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003ePulse Output\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003e1000 pulses\/kWh\u003c\/strong\u003e on auxiliary terminals — IEC 62053-31, opto-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eLCD 8 × 3.5mm characters — auto-cycle or static register\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eOptical Port\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eIEC 629056-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eTerminals\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eBS 7856; 8.2mm solid brass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eIP Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eIP52 (BS EN 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e–40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600;\"\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px;\"\u003e91 × 125 × 40 mm (meter body, excluding extended cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: 600; font-size: 15px; padding: 10px 16px; border-radius: 6px 6px 0 0;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #c8e6e3; border-top: none; border-radius: 0 0 6px 6px; margin-bottom: 8px;\"\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #f0faf9;\"\u003eDo I need a generation meter for my solar PV installation?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eYes — a \u003cstrong\u003eMID-approved generation meter is a requirement for MCS commissioning sign-off\u003c\/strong\u003e on any solar PV installation in the UK, and is required by DNOs and energy suppliers to validate generation figures for SEG (Smart Export Guarantee) and legacy FiT payments. Without a MID-approved meter, the installation cannot be officially commissioned and the homeowner cannot register for export payments. Some DNOs also specify the type (total generation vs bi-directional) depending on whether battery storage is present — always check your DNO's connection requirements before ordering.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #fff;\"\u003eWhat is the difference between a generation meter and the import meter fitted by my energy supplier?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eThe \u003cstrong\u003eimport meter fitted by your energy supplier\u003c\/strong\u003e measures electricity consumed from the grid — it only counts energy flowing into the property. The \u003cstrong\u003egeneration meter\u003c\/strong\u003e (this product) measures the electricity produced by the solar PV array. These are two separate measurements: one records what you buy, the other records what you generate. For SEG payments, the energy supplier typically pays on the generation meter reading (total generated) or the export meter reading (what actually left your property) depending on your tariff. The generation meter must be MID-approved and accessible for reading.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #f0faf9;\"\u003eIs this meter suitable for a system with a battery?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eFor \u003cstrong\u003esolar PV with battery storage\u003c\/strong\u003e, a simple total generation meter like the ECA2.V is generally \u003cstrong\u003enot appropriate\u003c\/strong\u003e. When a battery is present and can be charged from the grid (as with most hybrid inverters), a generation meter would incorrectly count grid-charged battery discharge as solar generation — inflating the generation reading. The correct meter for hybrid and battery storage systems is the \u003cstrong\u003eEmlite ECA2 Bi-Directional\u003c\/strong\u003e, which measures import, export, and NET separately, giving the true net export figure required by MCS and energy suppliers for SEG registration with storage.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #fff;\"\u003eCan the pulse output be connected to my inverter's monitoring system?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eYes — the \u003cstrong\u003e1000 pulse\/kWh output\u003c\/strong\u003e on the ECA2.V's auxiliary terminals is compatible with most inverter and energy monitoring platforms that accept an S0 or open-collector pulse input, including GivEnergy, SolarEdge, Solis, Fox ESS, and myenergi systems. The output is opto-isolated (IEC 62053-31), which prevents ground-loop issues when connecting to external monitoring equipment. Check your inverter or monitoring system's input specifications for pulse type (active high\/low, voltage range) and configure accordingly. Two wires connect from the meter's aux terminals to the monitoring device's pulse input terminals.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #f0faf9;\"\u003eDoes the extended cover affect the meter's IP rating?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eThe \u003cstrong\u003eextended terminal cover\u003c\/strong\u003e provides additional wiring space at the terminal block — useful when routing generation meter tails in a consumer unit alongside other cabling. It does \u003cstrong\u003enot significantly change the IP52 rating\u003c\/strong\u003e of the meter itself, as the cover seals the terminal area. IP52 protects against dust ingress and vertically falling water when the unit is tilted up to 15° — suitable for indoor meter board and consumer unit enclosures. For fully outdoor exposed locations, the meter should be housed in an IP65-rated enclosure regardless of the terminal cover fitted.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Emlite","offers":[{"title":"Default Title","offer_id":58693535564125,"sku":"ECA2v","price":37.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Emlite1PhaseMeter100APulsedwithExtendedCover.webp?v=1776153841"},{"product_id":"emlite-bi-directional-3-ph-generation-meter-emp-az-100a-1000-pulse-kwh","title":"Emlite EMP1-AZ Bi-Directional 3-Phase 100A Generation Meter 1000 Pulse kWh MID Approved Solar PV Three Phase","description":"\u003cdiv style=\"font-size: 16px; font-family: Arial,Helvetica,sans-serif; color: #1a1a1a; max-width: 900px; margin: 0 auto; line-height: 1.6;\"\u003e\n\u003cp style=\"margin: 0 0 18px;\"\u003eThe \u003cstrong\u003eEmlite EMP1-AZ\u003c\/strong\u003e is a \u003cstrong\u003ethree-phase, direct-connect 100A per phase MID-approved electricity meter with 1000 pulse\/kWh output\u003c\/strong\u003e — the three-phase equivalent of the bi-directional ECA2. Designed for properties with a \u003cstrong\u003ethree-phase (3×230V \/ 400V four-wire) electrical supply\u003c\/strong\u003e and three-phase solar PV inverters, it measures \u003cstrong\u003e4-quadrant active energy\u003c\/strong\u003e (import and export, active and reactive) across all three phases simultaneously, with registers displayed on the 8-digit LCD. Used for \u003cstrong\u003ethree-phase MCS generation metering, SEG compliance, and commercial solar sub-metering\u003c\/strong\u003e. The opto-isolated pulse output integrates with energy management systems, BMS, and inverter monitoring platforms. MID approved to \u003cstrong\u003eClass B (1%) active energy\u003c\/strong\u003e and \u003cstrong\u003eClass 2 reactive energy\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv style=\"border-left: 4px solid #008377CF; background: #e6f4f3; padding: 10px 16px; margin-bottom: 22px; border-radius: 0 6px 6px 0;\"\u003e\n\u003cstrong style=\"color: #005c54;\"\u003eℹ When is a 3-Phase Meter Required?\u003c\/strong\u003e\u003cbr\u003eA three-phase generation meter is needed when the \u003cstrong\u003esolar PV inverter is a three-phase model\u003c\/strong\u003e or when the property has a \u003cstrong\u003ethree-phase supply and the inverter distributes across all three phases\u003c\/strong\u003e. Fitting a single-phase meter on one phase of a three-phase inverter would count only one-third of total generation. The EMP1-AZ measures all three phases simultaneously. For single-phase domestic supplies (the majority of UK homes), the ECA2 single-phase meters are the correct choice.\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: 600; font-size: 15px; padding: 10px 16px; border-radius: 6px 6px 0 0;\"\u003eFeatures \u0026amp; Benefits\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(255px,1fr)); gap: 12px; background: #e6f4f3; padding: 14px; border-radius: 0 0 6px 6px; margin-bottom: 22px;\"\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ MID Approved — Legal for Billing \u0026amp; MCS Sign-Off\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong\u003eMID (Measuring Instruments Directive 2004\/22\/EC)\u003c\/strong\u003e approval certifies a meter's accuracy for trade, billing, and official use. For solar PV installations in the UK, a \u003cstrong\u003eMID-approved generation meter is required by DNOs and MCS\u003c\/strong\u003e as the legally valid measurement of exported or generated electricity — a non-MID meter cannot be used for SEG payments, FiT legacy claims, or MCS commissioning sign-off. The Emlite meters carry full MID approval to Class B (1% accuracy, EN 50470-1\/3), satisfying all DNO and MCS submission requirements.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ 4-Quadrant Measurement — All 3 Phases\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eThe EMP1-AZ measures \u003cstrong\u003e4-quadrant active energy\u003c\/strong\u003e — import and export in both directions across all three phases simultaneously. Separate registers exist for each quadrant, all accessible via the optical port. \u003cstrong\u003eOptional power quality data\u003c\/strong\u003e (per-phase voltage, current, and power) is also readable via the optical port for power factor analysis and grid compliance verification. An energy direction indicator on the display shows instantaneous import\/export status as a summation across all three phases.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ 1000 Pulse\/kWh — Energy Monitor Integration\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eThe \u003cstrong\u003e1000 pulse per kWh opto-isolated output\u003c\/strong\u003e on the auxiliary terminals feeds real-time energy data into \u003cstrong\u003eenergy management systems, BMS, AMR data loggers, and smart home platforms\u003c\/strong\u003e. Each pulse represents 1Wh — at 1000 pulses\/kWh the resolution supports accurate sub-hourly monitoring. The output conforms to IEC 62053-31 and is electrically isolated, preventing ground-loop issues when connecting to third-party monitoring equipment. Compatible with GivEnergy, SolarEdge, Solis, Fox ESS, myenergi, and most modern inverter monitoring platforms.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ 100A Per Phase — Direct Connected — 25mm² Terminals\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eThe EMP1-AZ is a \u003cstrong\u003edirect-connect (whole current) meter at 100A per phase\u003c\/strong\u003e — no external current transformers required, covering standard three-phase domestic and most light commercial solar PV installations. \u003cstrong\u003eDIN43857-Part 2\u003c\/strong\u003e terminal arrangement with 150mm fixing centres. Solid brass terminals with 8.2mm cable entry accepting up to \u003cstrong\u003e25mm² tails\u003c\/strong\u003e. Three-phase, four-wire connection: L1, L2, L3, N at 3×230V phase-to-neutral \/ 400V phase-to-phase.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ Optical Port — Tamper Resistant — Solid Brass Terminals\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eAn \u003cstrong\u003eoptical communications port\u003c\/strong\u003e (IEC 629056-21) enables electronic meter reading using a standard probe and software — useful for commissioning verification and commercial AMR reading. The meter is \u003cstrong\u003etamper resistant\u003c\/strong\u003e with reverse energy fraud detection and is sealed for life. \u003cstrong\u003eSolid brass cable terminals\u003c\/strong\u003e (8.2mm diameter) give robust, low-resistance connections at full 100A rating. The meter withstands \u003cstrong\u003ehigh-voltage events and 140% overcurrent\u003c\/strong\u003e without failure — important in grid-connected installations that may experience transients.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ IP54 — Class B + Class 2 — –25°C to +55°C\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong\u003eIP54\u003c\/strong\u003e ingress protection (protected against dust deposits and water splashing from any direction) is higher than the single-phase ECA2's IP52, reflecting the EMP1's suitability for more exposed meter board positions. Active energy accuracy is \u003cstrong\u003eClass B (1%, EN 50470-1\/3)\u003c\/strong\u003e; reactive energy is \u003cstrong\u003eClass 2 (IEC 62053-23)\u003c\/strong\u003e. Operational from \u003cstrong\u003e–25°C to +55°C\u003c\/strong\u003e. Dimensions 170W × 200.2H × 65D mm.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: 600; font-size: 15px; padding: 10px 16px; border-radius: 6px 6px 0 0;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 22px; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; width: 44%; border-bottom: 1px solid #c8e6e3;\"\u003eManufacturer \/ Model\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eEmlite — \u003cstrong\u003eEMP1-AZ\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003ePhase\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eThree phase (3×230V \/ 400V, four-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eMeasurement\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e4-quadrant active energy (import \u0026amp; export, all phases); reactive energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e3 × 230V (phase-to-neutral); 400V withstand continuously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e50Hz ± 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eReference \/ Max Current\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eIref 5–20A per phase; \u003cstrong\u003eImax 100A per phase\u003c\/strong\u003e — direct connected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eAccuracy — Active Energy\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003eClass B (1%)\u003c\/strong\u003e — EN 50470-1\/3; fully MID approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eAccuracy — Reactive Energy\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eClass 2 — IEC 62053-23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003ePulse Output\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003e1000 pulses\/kWh\u003c\/strong\u003e — opto-isolated, IEC 62053-31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e8-digit LCD with phase indicators and energy direction symbol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eOptical Port\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eIEC 629056-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eTerminals\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eDIN43857-Part 2; 150 ± 1mm fixing centres; 8.2mm solid brass; 25mm² capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eIP Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003eIP54\u003c\/strong\u003e (BS EN 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e–25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px;\"\u003e170 × 200.2 × 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: 600; font-size: 15px; padding: 10px 16px; border-radius: 6px 6px 0 0;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #c8e6e3; border-top: none; border-radius: 0 0 6px 6px; margin-bottom: 8px;\"\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #f0faf9;\"\u003eWhen is a three-phase generation meter required rather than a single-phase one?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eA three-phase generation meter is required when: (a) the \u003cstrong\u003esolar PV inverter is a three-phase model\u003c\/strong\u003e, which is common for systems above approximately 3.68kWp per phase where the G98 per-phase limit is exceeded; or (b) the property has a \u003cstrong\u003ethree-phase supply and the inverter distributes output across all three phases\u003c\/strong\u003e. A single-phase meter placed on one phase of a three-phase inverter would only count one-third of total generation. The EMP1-AZ measures all three phases simultaneously and totals them into a single kWh figure. For single-phase supplies (the majority of UK domestic properties), use the ECA2 single-phase meters instead.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #fff;\"\u003eWhat does 4-quadrant energy measurement mean?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003e\n\u003cstrong\u003e4-quadrant measurement\u003c\/strong\u003e means the meter tracks active energy in all four combinations of direction and phase: import (active consumed from grid), export (active sent to grid), reactive energy imported, and reactive energy exported. This is more comprehensive than a simple import\/export meter, which only tracks active energy. For solar PV, the key registers are active import and export — but \u003cstrong\u003ereactive energy data\u003c\/strong\u003e (Class 2, IEC 62053-23) is valuable for commercial installations where power factor analysis is required, for G99 compliance monitoring, and for future grid balancing applications. All quadrant values are stored and readable via the optical port.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #f0faf9;\"\u003eIs the EMP1-AZ suitable for large commercial solar installations?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eYes — the EMP1-AZ is suitable for \u003cstrong\u003ethree-phase commercial and large domestic solar PV installations\u003c\/strong\u003e up to 100A per phase. At 3×230V nominal, this covers three-phase systems up to approximately 69kW (100A × 230V × 3 phases), which encompasses the majority of commercial rooftop solar installations requiring a direct-connect meter. For very large commercial systems above 100A per phase, CT (current transformer) based metering with appropriate CT ratios and a CT-connected meter would be required instead. The MID approval and Class B accuracy are valid for billing and official reporting in all commercial contexts.\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #fff;\"\u003eCan I integrate the EMP1-AZ pulse output with my inverter monitoring platform?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eYes — the \u003cstrong\u003e1000 pulse\/kWh opto-isolated output\u003c\/strong\u003e (IEC 62053-31) connects to energy management systems, BMS, AMR data loggers, and inverter monitoring platforms that accept an S0 or open-collector pulse input. Most commercial-grade three-phase inverter monitoring platforms (Solis, GivEnergy, SolarEdge, Huawei, etc.) can accept a pulse input for independent generation verification. The pulse polarity must be observed when connecting — consult your monitoring platform's wiring diagram for the correct terminal orientation. The optical port (IEC 629056-21) provides an additional communications route for electronic meter reading without requiring a pulse input on the monitoring device.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #f0faf9;\"\u003eWhat cable size can the EMP1-AZ terminals accept?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eThe EMP1-AZ uses \u003cstrong\u003eDIN43857-Part 2 terminal construction\u003c\/strong\u003e with solid brass terminals featuring an \u003cstrong\u003e8.2mm diameter cable entry\u003c\/strong\u003e — this accommodates meter tails up to \u003cstrong\u003e25mm² cross-sectional area\u003c\/strong\u003e, which covers the cable sizes used on the vast majority of three-phase generation and supply connections. The terminal fixing centres are 150 ± 1mm conforming to DIN43857. Two steel-slotted M6 terminal screws secure each conductor. For very large commercial tails above 25mm², consult Emlite technical support regarding terminal options.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Emlite","offers":[{"title":"Default Title","offer_id":58693535596893,"sku":"EMP1-AZ","price":107.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/EmLiteEMP1ThreePhaseSolarPVImportExportMeter.webp?v=1760365398"},{"product_id":"emlite-1-ph-bi-directional-generation-meter-100a-1000-pulse-kwh-inc-cover","title":"Emlite ECA2 Single Phase Bi-Directional Generation Meter 100A 1000 Pulse kWh MID Import Export NET Solar Battery Hybrid with Cover","description":"\u003cdiv style=\"font-size: 16px; font-family: Arial,Helvetica,sans-serif; color: #1a1a1a; max-width: 900px; margin: 0 auto; line-height: 1.6;\"\u003e\n\u003cp style=\"margin: 0 0 18px;\"\u003eThe \u003cstrong\u003eEmlite ECA2 Bi-Directional\u003c\/strong\u003e is a \u003cstrong\u003esingle-phase, direct-connect 100A MID-approved electricity meter\u003c\/strong\u003e measuring energy in \u003cstrong\u003eboth directions simultaneously\u003c\/strong\u003e — displaying separate \u003cstrong\u003eImport, Export, and NET registers\u003c\/strong\u003e on the auto-cycling LCD, with a \u003cstrong\u003e1000 pulse\/kWh output\u003c\/strong\u003e for integration with energy management and monitoring systems. It is the correct meter for \u003cstrong\u003ehybrid inverter systems with battery storage\u003c\/strong\u003e, where a simple total generation reading would not distinguish between solar energy consumed in the home, battery charge\/discharge, and genuine net export to the grid. MCS and DNOs require the NET figure on battery-plus-solar systems for accurate SEG compliance. Supplied with an extended terminal cover. MID approved to Class B (1% accuracy, EN 50470-1\/3).\u003c\/p\u003e\n\u003cdiv style=\"border-left: 4px solid #008377CF; background: #e6f4f3; padding: 10px 16px; margin-bottom: 22px; border-radius: 0 6px 6px 0;\"\u003e\n\u003cstrong style=\"color: #005c54;\"\u003eℹ Bi-Directional vs Total Generation — Which Meter Do You Need?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTotal generation meter (ECA2.V):\u003c\/strong\u003e PV-only systems without battery storage. Counts all kWh generated.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBi-directional meter (this product):\u003c\/strong\u003e Required for \u003cstrong\u003ehybrid and DC-coupled systems with battery\u003c\/strong\u003e — GivEnergy, Fox ESS, Solis, SolarEdge, etc. The NET register correctly measures only the true net exported energy, eliminating grid-charged battery discharge from the generation count. Check your DNO and energy supplier requirements before ordering.\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: 600; font-size: 15px; padding: 10px 16px; border-radius: 6px 6px 0 0;\"\u003eFeatures \u0026amp; Benefits\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(255px,1fr)); gap: 12px; background: #e6f4f3; padding: 14px; border-radius: 0 0 6px 6px; margin-bottom: 22px;\"\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ MID Approved — Legal for Billing \u0026amp; MCS Sign-Off\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong\u003eMID (Measuring Instruments Directive 2004\/22\/EC)\u003c\/strong\u003e approval certifies a meter's accuracy for trade, billing, and official use. For solar PV installations in the UK, a \u003cstrong\u003eMID-approved generation meter is required by DNOs and MCS\u003c\/strong\u003e as the legally valid measurement of exported or generated electricity — a non-MID meter cannot be used for SEG payments, FiT legacy claims, or MCS commissioning sign-off. The Emlite meters carry full MID approval to Class B (1% accuracy, EN 50470-1\/3), satisfying all DNO and MCS submission requirements.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ Three Registers — Import, Export \u0026amp; NET\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eThe bi-directional ECA2 auto-cycles through \u003cstrong\u003ethree distinct energy registers\u003c\/strong\u003e: \u003cstrong\u003eImport\u003c\/strong\u003e (energy drawn from the grid), \u003cstrong\u003eExport\u003c\/strong\u003e (energy sent to the grid), and \u003cstrong\u003eNET\u003c\/strong\u003e (the running net balance). For a solar plus battery system, the NET value is the true amount of energy that left the property to the grid — the figure an energy supplier applies SEG rates to. Import and Export are retained separately for system performance analysis and tariff optimisation. All registers are individually accessible via the optical port for remote meter reading.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ 1000 Pulse\/kWh — Energy Monitor Integration\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eThe \u003cstrong\u003e1000 pulse per kWh opto-isolated output\u003c\/strong\u003e on the auxiliary terminals feeds real-time energy data into \u003cstrong\u003eenergy management systems, BMS, AMR data loggers, and smart home platforms\u003c\/strong\u003e. Each pulse represents 1Wh — at 1000 pulses\/kWh the resolution supports accurate sub-hourly monitoring. The output conforms to IEC 62053-31 and is electrically isolated, preventing ground-loop issues when connecting to third-party monitoring equipment. Compatible with GivEnergy, SolarEdge, Solis, Fox ESS, myenergi, and most modern inverter monitoring platforms.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ Optical Port — Tamper Resistant — Solid Brass Terminals\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eAn \u003cstrong\u003eoptical communications port\u003c\/strong\u003e (IEC 629056-21) enables electronic meter reading using a standard probe and software — useful for commissioning verification and commercial AMR reading. The meter is \u003cstrong\u003etamper resistant\u003c\/strong\u003e with reverse energy fraud detection and is sealed for life. \u003cstrong\u003eSolid brass cable terminals\u003c\/strong\u003e (8.2mm diameter) give robust, low-resistance connections at full 100A rating. The meter withstands \u003cstrong\u003ehigh-voltage events and 140% overcurrent\u003c\/strong\u003e without failure — important in grid-connected installations that may experience transients.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ Compact — IP52 — Wide Temperature Range\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eAt \u003cstrong\u003e91 × 125 × 40mm\u003c\/strong\u003e, the ECA2 body is one of the most compact MID-approved single-phase meters available, fitting space-constrained consumer unit enclosures with the extended cover adding terminal wiring space. \u003cstrong\u003eIP52\u003c\/strong\u003e (BS EN 60529) for indoor and protected-location installation. Operational across \u003cstrong\u003e–40°C to +70°C\u003c\/strong\u003e — suitable for unheated outbuildings and garage boards. Rated to 140% overcurrent and capable of withstanding high-voltage transients without failure.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: 600; font-size: 15px; padding: 10px 16px; border-radius: 6px 6px 0 0;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 22px; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; width: 44%; border-bottom: 1px solid #c8e6e3;\"\u003eManufacturer \/ Model\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eEmlite — \u003cstrong\u003eECA2 Bi-Directional (ECA2.NV \/ ECA2.BI)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003ePhase\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eRegisters\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003eImport · Export · NET\u003c\/strong\u003e (auto-cycling LCD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e220–240V AC; max 276V; withstand 415V (up to 6 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e50Hz ± 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eReference \/ Max Current\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eIref 5–20A; \u003cstrong\u003eImax 100A\u003c\/strong\u003e (140% overcurrent rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003eClass B (1%)\u003c\/strong\u003e — EN 50470-1\/3; fully MID approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003ePulse Output\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003e1000 pulses\/kWh\u003c\/strong\u003e — aux terminals, IEC 62053-31, opto-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eOptical Port\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eIEC 629056-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eTerminals\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eBS 7856; 8.2mm solid brass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eIP Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eIP52 (BS EN 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e–40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600;\"\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px;\"\u003e91 × 125 × 40 mm (meter body, excluding extended cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: 600; font-size: 15px; padding: 10px 16px; border-radius: 6px 6px 0 0;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #c8e6e3; border-top: none; border-radius: 0 0 6px 6px; margin-bottom: 8px;\"\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #f0faf9;\"\u003eWhen do I need a bi-directional meter instead of a standard generation meter?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eUse a \u003cstrong\u003ebi-directional meter whenever battery storage is part of the system\u003c\/strong\u003e. With a standard total generation meter, grid-charged battery discharge can be counted as solar generation — inflating the kWh figure and invalidating MCS and SEG compliance. The bi-directional ECA2 measures \u003cstrong\u003eimport, export, and NET separately\u003c\/strong\u003e: the NET figure is the true net export to the grid, which is the value MCS and most energy suppliers require for SEG registration on systems with storage. Check your DNO's G99 or G98 application requirements and your intended energy supplier's SEG terms before selecting a meter type.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #fff;\"\u003eWhat does the NET reading actually show?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eThe \u003cstrong\u003eNET register\u003c\/strong\u003e is the mathematical result of \u003cstrong\u003etotal export minus total import\u003c\/strong\u003e (or vice versa — it tracks the running net balance). For a typical day on a solar plus battery system: the array generates energy during the day, some charges the battery, some powers the home, and any surplus exports. At night the battery discharges to power the home. The NET value accounts for all of this and shows only the kWh that genuinely left the property to the grid. This is the figure that represents the true benefit provided to the grid and is therefore the figure that SEG rates should be applied to — import and export readings are also retained separately for system performance analysis.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #f0faf9;\"\u003eCan I use this meter for a PV-only installation without a battery?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eYes — the bi-directional ECA2 works on PV-only systems, but for a \u003cstrong\u003estraightforward PV-only installation without battery storage\u003c\/strong\u003e, the \u003cstrong\u003eECA2.V total generation meter\u003c\/strong\u003e is simpler and equally compliant. The bi-directional model adds the NET and import registers — useful for performance analysis, but not required by MCS or most DNOs for a basic PV system. If there is any possibility of adding battery storage in the future, fitting the bi-directional meter now avoids a meter swap later.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #fff;\"\u003eDoes the meter need to be located next to the consumer unit?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eThe generation meter must be accessible for reading, but does not need to be immediately adjacent to the consumer unit. In most domestic installations it is fitted in or next to the consumer unit enclosure for convenience. The pulse output cable can run up to several metres to reach an inverter or monitoring device — check your monitoring system's specifications for maximum cable run on the pulse input. The 1m optical port reading requires the probe to be physically presented to the meter face, so the meter should be accessible without tools.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #f0faf9;\"\u003eIs this meter suitable for commercial solar installations?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eYes — the ECA2 bi-directional is used in both domestic and \u003cstrong\u003ecommercial single-phase solar installations\u003c\/strong\u003e. The 100A Imax rating covers single-phase supplies up to approximately 23kW at 230V, which encompasses most commercial single-phase inverter capacities. For three-phase commercial installations — where the inverter is a 3-phase model or the supply is 3-phase — the \u003cstrong\u003eEmlite EMP1-AZ three-phase bi-directional meter\u003c\/strong\u003e is the correct product. The MID approval applies across all applications, making this meter legally valid for billing and FiT\/SEG commercial claims.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e","brand":"Emlite","offers":[{"title":"Default Title","offer_id":58693535727965,"sku":"ECA2NZ","price":39.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/EmliteSinglePhaseECA2-MID.jpg?v=1776155348"},{"product_id":"sdm120db-mid-single-phase-din-rail-mounted-digital-meter-with-back-light","title":"Eastron SDM120DB-MID Single-Phase DIN Rail Energy Meter with Backlit LCD Display","description":"\u003cdiv style=\"font-size:16px;font-family:'Helvetica Neue',Helvetica,Arial,sans-serif;color:#222;max-width:900px;margin:0 auto;line-height:1.6;\"\u003e\n\n  \u003c!-- Intro --\u003e\n  \u003cp style=\"margin:0 0 18px;\"\u003e\n    The \u003cstrong\u003eEastron SDM120DB-MID\u003c\/strong\u003e is a compact, \u003cstrong\u003eMID-certified single-phase energy meter\u003c\/strong\u003e built for accurate, billing-grade kWh measurement in residential, commercial, and light industrial settings. Housed in a slim \u003cstrong\u003e1-module (18 mm) DIN rail enclosure\u003c\/strong\u003e, it clips neatly into any standard distribution board and begins logging consumption immediately — no configuration software required for basic use. The \u003cstrong\u003ebacklit LCD display\u003c\/strong\u003e distinguishes the SDM120DB from the plain SDM120D, giving clear readings even in dimly lit consumer units. A \u003cstrong\u003e1000 imp\/kWh pulse output\u003c\/strong\u003e enables straightforward integration with external energy management systems, data loggers, or pulse counters, making this meter equally at home as a standalone sub-meter or as a node in a larger monitoring network.\n  \u003c\/p\u003e\n\n  \u003c!-- Stat strip --\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;margin:0 0 24px;\"\u003e\n    \u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#fff;border-radius:8px;padding:16px 14px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:26px;font-weight:700;\"\u003e45 A\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003eMax Direct Current\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#fff;border-radius:8px;padding:16px 14px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:26px;font-weight:700;\"\u003e230 V\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003eNominal AC Voltage\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#fff;border-radius:8px;padding:16px 14px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:26px;font-weight:700;\"\u003eClass 1\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003eAccuracy \/ Class B MID\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#fff;border-radius:8px;padding:16px 14px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:26px;font-weight:700;\"\u003e18 mm\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003e1-Module DIN Width\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#fff;border-radius:8px;padding:16px 14px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:26px;font-weight:700;\"\u003e1000\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003eimp \/ kWh Pulse Rate\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#fff;border-radius:8px;padding:16px 14px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:26px;font-weight:700;\"\u003eIP51\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003eIngress Protection\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Callout: installer warning --\u003e\n  \u003cdiv style=\"background:#fff3cd;border-left:5px solid #c0392b;border-radius:6px;padding:14px 18px;margin:0 0 16px;\"\u003e\n    \u003cstrong style=\"color:#c0392b;\"\u003e⚠ Installer \/ Safety Notice\u003c\/strong\u003e\u003cbr\u003e\n    Installation must be carried out by a \u003cstrong\u003equalified electrician\u003c\/strong\u003e. Always isolate the circuit before connecting or disconnecting the meter. Never operate with the terminal cover removed. Do not connect this meter to a three-phase 400 V network — it is rated for \u003cstrong\u003esingle-phase 230 V AC only\u003c\/strong\u003e. Observe polarity on the pulse output (5–27 V DC, max 27 mA opto-coupler).\n  \u003c\/div\u003e\n\n  \u003c!-- Callout: MID compliance note --\u003e\n  \u003cdiv style=\"background:#e6f4f3;border-left:5px solid #008377;border-radius:6px;padding:14px 18px;margin:0 0 16px;\"\u003e\n    \u003cstrong style=\"color:#005c54;\"\u003eℹ MID B+D Certified — Suitable for Billing \u0026amp; Sub-Metering\u003c\/strong\u003e\u003cbr\u003e\n    The SDM120DB-MID carries \u003cstrong\u003eMID (Measuring Instruments Directive) B+D certification\u003c\/strong\u003e under EU Directive 2014\/32\/EU (certificate number 0120\/SGS0141), recognised in the UK. This means the meter is legally approved for energy billing, tenant sub-metering, feed-in monitoring, and any application where measured energy data has commercial or contractual significance. Sealable terminal covers are supplied to prevent tampering and preserve legal traceability.\n  \u003c\/div\u003e\n\n  \u003c!-- Callout: compatibility --\u003e\n  \u003cdiv style=\"background:#fff8e1;border-left:5px solid #f0a500;border-radius:6px;padding:14px 18px;margin:0 0 24px;\"\u003e\n    \u003cstrong style=\"color:#7a5a00;\"\u003e⚠ Compatibility Note\u003c\/strong\u003e\u003cbr\u003e\n    This is a \u003cstrong\u003edirect-connected meter rated to 45 A\u003c\/strong\u003e. It is not suitable for higher-current circuits — for loads above 45 A, a current-transformer (CT) operated variant such as the SDM120CT-Modbus is required. The pulse output requires an external DC supply (5–27 V DC); it is not self-powered. If remote data logging via RS485 Modbus or M-Bus is needed, consider the SDM120-Modbus or SDM120-MBus variants instead.\n  \u003c\/div\u003e\n\n  \u003c!-- Feature grid --\u003e\n  \u003cdiv style=\"margin:0 0 8px;\"\u003e\n    \u003cdiv style=\"font-size:20px;font-weight:700;color:#005c54;margin:0 0 14px;border-bottom:2px solid #008377CF;padding-bottom:6px;\"\u003eKey Features\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;margin:0 0 28px;\"\u003e\n\n    \u003cdiv style=\"flex:1 1 260px;border:1px solid #d0e8e6;border-radius:8px;padding:18px;background:#f9fdfd;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#005c54;font-size:15px;margin-bottom:8px;\"\u003e🔅 Backlit LCD Display\u003c\/div\u003e\n      \u003cp style=\"margin:0;font-size:14px;\"\u003eThe \u003cstrong\u003ewhite-backlit LCD screen\u003c\/strong\u003e provides clear, easy-to-read figures in any lighting condition — ideal for consumer units in cupboards, lofts, or plant rooms. Scroll through readings using the front-panel button: total kWh, import kWh, export kWh, voltage, current, active power, frequency, and power factor are all accessible.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex:1 1 260px;border:1px solid #d0e8e6;border-radius:8px;padding:18px;background:#f9fdfd;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#005c54;font-size:15px;margin-bottom:8px;\"\u003e✅ MID B+D Legal-for-Trade Accuracy\u003c\/div\u003e\n      \u003cp style=\"margin:0;font-size:14px;\"\u003e\u003cstrong\u003eClass 1 \/ Class B accuracy\u003c\/strong\u003e certified to IEC 62053-21 and EN 50470-3. Active energy measurement error is within ±1% across the rated operating range. This \u003cstrong\u003ebilling-grade precision\u003c\/strong\u003e satisfies UK and EU metering regulations for landlord–tenant sub-billing, EV charge point metering, and solar generation monitoring.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex:1 1 260px;border:1px solid #d0e8e6;border-radius:8px;padding:18px;background:#f9fdfd;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#005c54;font-size:15px;margin-bottom:8px;\"\u003e🔌 1000 imp\/kWh Pulse Output\u003c\/div\u003e\n      \u003cp style=\"margin:0;font-size:14px;\"\u003eA \u003cstrong\u003efixed-rate opto-isolated pulse output at 1000 impulses per kWh\u003c\/strong\u003e allows the meter to feed data to energy management systems, building management controllers, Raspberry Pi loggers, or any pulse-counting device. The LED pulse indicator also flashes in real time — faster consumption, faster flash — giving instant visual feedback on load level.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex:1 1 260px;border:1px solid #d0e8e6;border-radius:8px;padding:18px;background:#f9fdfd;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#005c54;font-size:15px;margin-bottom:8px;\"\u003e🔩 1-Module DIN Rail Fit\u003c\/div\u003e\n      \u003cp style=\"margin:0;font-size:14px;\"\u003eAt just \u003cstrong\u003e18 mm wide\u003c\/strong\u003e, the SDM120DB occupies only a single module slot on a standard 35 mm DIN rail — the same footprint as a single MCB. This makes it \u003cstrong\u003eeasy to retrofit\u003c\/strong\u003e into existing distribution boards without expanding the enclosure, and allows multiple meters to be installed side by side for multi-circuit sub-metering.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex:1 1 260px;border:1px solid #d0e8e6;border-radius:8px;padding:18px;background:#f9fdfd;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#005c54;font-size:15px;margin-bottom:8px;\"\u003e🔥 Tamper-Resistant Design\u003c\/div\u003e\n      \u003cp style=\"margin:0;font-size:14px;\"\u003e\u003cstrong\u003eSealable terminal covers\u003c\/strong\u003e are supplied as standard, preventing unauthorised access to wiring connections and maintaining the integrity of the MID certification. The self-extinguishing UL94V0-rated enclosure provides additional fire safety. The meter carries \u003cstrong\u003eProtective Class II\u003c\/strong\u003e double-insulated construction.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"flex:1 1 260px;border:1px solid #d0e8e6;border-radius:8px;padding:18px;background:#f9fdfd;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#005c54;font-size:15px;margin-bottom:8px;\"\u003e🏠 Wide Application Range\u003c\/div\u003e\n      \u003cp style=\"margin:0;font-size:14px;\"\u003eSuited to \u003cstrong\u003eresidential sub-metering, EV charger energy measurement, solar PV generation monitoring, outbuilding supplies, office landlord billing, and light commercial circuits\u003c\/strong\u003e. The SDM120DB measures both import and export kWh, making it particularly useful where solar generation or battery storage creates bi-directional energy flows on a single-phase circuit.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- Spec table --\u003e\n  \u003cdiv style=\"font-size:20px;font-weight:700;color:#005c54;margin:0 0 12px;border-bottom:2px solid #008377CF;padding-bottom:6px;\"\u003eTechnical Specifications\u003c\/div\u003e\n\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;margin:0 0 28px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background:#008377CF;color:#fff;\"\u003e\n        \u003cth style=\"padding:10px 12px;text-align:left;width:42%;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding:10px 12px;text-align:left;\"\u003eValue \/ Detail\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eModel\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eSDM120DB-MID\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003ePhases\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eSingle-phase, two-wire\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eNominal Voltage (Uₙ)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e230 V AC (120 V AC version also available)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eOperational Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e80%–120% of Uₙ\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eBasic Current (Iᵦ)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e5 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eMaximum Rated Current (I\u003csub\u003emax\u003c\/sub\u003e)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e45 A (direct connected)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eStarting Current\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e0.4% of Iᵦ\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eFrequency\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e50 Hz \/ 60 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eAccuracy Class\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eClass 1 (IEC 62053-21) \/ Class B (EN 50470-3)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eActive Energy Accuracy\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e±1% of range maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eVoltage Accuracy\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e0.5% of range maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eCurrent Accuracy\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e0.5% of nominal\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eLCD with white backlight\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eMeasured Parameters\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eTotal kWh, import kWh, export kWh, voltage (V), current (A), active power (W), frequency (Hz), power factor\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eMax. Display Reading\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e99,999.9 kWh\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003ePulse Output\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e1000 imp\/kWh, opto-isolated SPST-NO, 5–27 V DC, max 27 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eInternal Power Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e≤ 2 W \/ 10 VA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eDIN Rail Width\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e18 mm (1 module)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e18 × 119 × 62 mm (per DIN 43880)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eDIN Rail Mounting\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e35 mm standard DIN rail\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eIngress Protection\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eIP51 (indoor use)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eProtective Class\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eClass II (double insulated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eInstallation Category\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eCAT III\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eAC Voltage Withstand\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e4 kV for 1 minute\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eImpulse Voltage Withstand\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e6 kV (1.2 µs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eESD\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e8 kV contact \/ 15 kV air gap\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e−25°C to +55°C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e−40°C to +70°C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e≤ 90% RH, non-condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eAltitude\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eUp to 2000 m\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eEnclosure Material\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eSelf-extinguishing UL94V0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eTerminal Cover\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eSealable, supplied as standard\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eMID Certification\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eEN 50470-1 \u0026amp; EN 50470-3 Class B (certificate 0120\/SGS0141)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eEMC\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eEN 61326-1, EN 61326-2-3, IEC 61326-1:2013\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eLVD\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eEN 61010-1, EN 61010-2-3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eInternational Standard\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003eIEC 62053-21 \/ EN 50470-1 \/ EN 50470-3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f2faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;font-weight:600;\"\u003eWarm-Up Time\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;border-bottom:1px solid #ddecea;\"\u003e3 seconds\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding:9px 12px;font-weight:600;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;\"\u003eZhejiang Eastron Electronic Co., Ltd.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- FAQ --\u003e\n  \u003cdiv style=\"font-size:20px;font-weight:700;color:#005c54;margin:0 0 12px;border-bottom:2px solid #008377CF;padding-bottom:6px;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\n  \u003cdiv style=\"margin:0 0 28px;\"\u003e\n\n    \u003cdetails style=\"border:1px solid #d0e8e6;border-radius:6px;margin-bottom:10px;overflow:hidden;\"\u003e\n      \u003csummary style=\"background:#008377CF;color:#fff;padding:13px 16px;cursor:pointer;font-weight:600;list-style:none;\"\u003e\n        What is the difference between the SDM120DB and the SDM120D?\n      \u003c\/summary\u003e\n      \u003cdiv style=\"padding:14px 16px;font-size:14px;line-height:1.6;\"\u003e\n        Both meters are functionally identical single-phase, 45 A, MID-certified kWh meters with a 1000 imp\/kWh pulse output and LCD readout. The only difference is the display: the \u003cstrong\u003eSDM120DB has a white backlight\u003c\/strong\u003e, while the SDM120D has a plain LCD with no illumination. Choose the SDM120DB if the meter will be read in a dark or low-light location such as a cupboard, loft, or poorly lit plant room.\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border:1px solid #d0e8e6;border-radius:6px;margin-bottom:10px;overflow:hidden;\"\u003e\n      \u003csummary style=\"background:#008377CF;color:#fff;padding:13px 16px;cursor:pointer;font-weight:600;list-style:none;\"\u003e\n        Can this meter be used for EV charger sub-metering?\n      \u003c\/summary\u003e\n      \u003cdiv style=\"padding:14px 16px;font-size:14px;line-height:1.6;\"\u003e\n        Yes — the SDM120DB-MID is a popular choice for \u003cstrong\u003esingle-phase EV charger monitoring\u003c\/strong\u003e. Its MID B+D certification satisfies the metering accuracy requirements applicable to public and workplace charge points, and its 1000 imp\/kWh pulse output can interface with charge point management systems. For a 7.2 kW single-phase charger the 45 A current rating is sufficient (32 A circuit). If you need Modbus RS485 communication for direct data integration with an EVSE or energy management platform, consider the SDM120-Modbus variant.\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border:1px solid #d0e8e6;border-radius:6px;margin-bottom:10px;overflow:hidden;\"\u003e\n      \u003csummary style=\"background:#008377CF;color:#fff;padding:13px 16px;cursor:pointer;font-weight:600;list-style:none;\"\u003e\n        Is the SDM120DB-MID suitable for solar PV generation monitoring?\n      \u003c\/summary\u003e\n      \u003cdiv style=\"padding:14px 16px;font-size:14px;line-height:1.6;\"\u003e\n        Yes. The meter records \u003cstrong\u003eimport kWh, export kWh, and total kWh\u003c\/strong\u003e separately, which makes it well suited to monitoring generation from a solar PV system on a single-phase connection. Export readings are displayed on-screen and reflected in the pulse output. For more detailed real-time monitoring alongside an inverter, a Modbus-enabled variant with RS485 communication may offer tighter integration with inverter data platforms, but for straightforward generation or consumption recording the SDM120DB-MID is an excellent low-cost choice.\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border:1px solid #d0e8e6;border-radius:6px;margin-bottom:10px;overflow:hidden;\"\u003e\n      \u003csummary style=\"background:#008377CF;color:#fff;padding:13px 16px;cursor:pointer;font-weight:600;list-style:none;\"\u003e\n        How does the pulse output work, and what can I connect it to?\n      \u003c\/summary\u003e\n      \u003cdiv style=\"padding:14px 16px;font-size:14px;line-height:1.6;\"\u003e\n        The pulse output is an \u003cstrong\u003eopto-isolated SPST normally-open contact\u003c\/strong\u003e (passive transistor) that generates 1000 pulses per kWh of energy consumed. It requires an \u003cstrong\u003eexternal DC supply of 5–27 V at up to 27 mA\u003c\/strong\u003e — it cannot drive a load directly without this external voltage source. Polarity must be observed (see the wiring diagram). It can be connected to energy management systems, building management controllers, data loggers, smart home hubs with pulse inputs, or simple pulse-counting devices. The onboard LED indicator mirrors the pulse output, flashing faster as load increases.\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border:1px solid #d0e8e6;border-radius:6px;margin-bottom:10px;overflow:hidden;\"\u003e\n      \u003csummary style=\"background:#008377CF;color:#fff;padding:13px 16px;cursor:pointer;font-weight:600;list-style:none;\"\u003e\n        What readings can I scroll through on the display?\n      \u003c\/summary\u003e\n      \u003cdiv style=\"padding:14px 16px;font-size:14px;line-height:1.6;\"\u003e\n        After power-on and a 3-second self-check, the default display shows \u003cstrong\u003etotal active energy (kWh)\u003c\/strong\u003e. Pressing the front-panel scroll button cycles through: \u003cstrong\u003eimport kWh → export kWh → voltage (V) → current (A) → active power (W) → frequency (Hz) → power factor\u003c\/strong\u003e. Holding the button for 3 seconds enters set-up mode. The maximum accumulated reading is 99,999.9 kWh before the counter rolls over.\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border:1px solid #d0e8e6;border-radius:6px;margin-bottom:10px;overflow:hidden;\"\u003e\n      \u003csummary style=\"background:#008377CF;color:#fff;padding:13px 16px;cursor:pointer;font-weight:600;list-style:none;\"\u003e\n        Does the SDM120DB-MID comply with UK metering regulations?\n      \u003c\/summary\u003e\n      \u003cdiv style=\"padding:14px 16px;font-size:14px;line-height:1.6;\"\u003e\n        Yes. The meter holds \u003cstrong\u003eMID certification under EU Directive 2014\/32\/EU\u003c\/strong\u003e (type examination certificate 0120\/SGS0141, Notified Body 0120), which remains recognised in Great Britain under retained legislation following the UK's departure from the EU. This makes it legally suitable for \u003cstrong\u003ebilling and sub-metering applications\u003c\/strong\u003e in the UK, including landlord–tenant arrangements, shared workspace energy billing, EV charge point energy accounting, and feed-in tariff verification. The sealable terminal covers maintain the integrity of the calibration seal once installed.\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Eastron","offers":[{"title":"Default Title","offer_id":62624139641181,"sku":"SDM120DB","price":29.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/EastronSDM120DB-MIDSingle-PhaseDINRailMountedDigital.webp?v=1763484961"},{"product_id":"fox-ess-ct-clamp-compatible-with-ac-hy-aio-ranges","title":"Fox ESS CT Clamp - compatible with AC, HY \u0026 AIO ranges","description":"\u003cdiv class=\"product-single__description rte\"\u003e\n\u003cp\u003e\u003cstrong\u003eFE-AIO-C | Split-core current transformer for export limitation and consumption monitoring on Fox ESS AC, Hybrid and AIO inverters.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e100A \/ 33.33mA split-core CT clamp (CTA016 specification).\u003c\/li\u003e\n\u003cli\u003eCompatible with Fox ESS AC chargers, hybrid inverters and AIO storage systems.\u003c\/li\u003e\n\u003cli\u003eActivates export limitation functionality to prevent grid export.\u003c\/li\u003e\n\u003cli\u003eSecondary CT option for tracking additional generation sources (wind, hydro, extra PV arrays).\u003c\/li\u003e\n\u003cli\u003eSimple clip-on installation - no need to disconnect live conductors.\u003c\/li\u003e\n\u003cli\u003eNon-invasive monitoring of single-phase AC current at consumer unit or supply position.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFunction \u0026amp; Application\u003c\/h2\u003e\n\u003cp\u003eThis CT clamp installs around the main live conductor to measure real-time import\/export current, feeding data to the Fox ESS inverter for precise export control and energy monitoring. Essential accessory for zero-export installations and systems requiring accurate consumption tracking.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e33.33 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSplit-core (clip-on)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass 1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC, Hybrid, AIO inverters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstalls on L1 live conductor at consumer unit or main supply for single-phase systems.\u003c\/li\u003e\n\u003cli\u003eConnects directly to inverter's CT input port via supplied cable.\u003c\/li\u003e\n\u003cli\u003eOrient correctly (K1 → L direction) for accurate current direction sensing.\u003c\/li\u003e\n\u003cli\u003eSecondary CT use requires inverter configuration for multi-source monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e FE-AIO-C\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e Fox ESS CT Clamp (100A\/33.33mA)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eEssential accessory for compliant zero-export Fox ESS installations and accurate energy monitoring across AC-coupled, hybrid and all-in-one storage systems.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Fox ESS","offers":[{"title":"Default Title","offer_id":62824961704285,"sku":"FE-AIO-CT","price":19.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/fox-ess-ct-clamp.jpg?v=1765171650"},{"product_id":"fox-ess-1ph-chint-meter","title":"Fox ESS 1ph Energy Meter CHNT DDSU666","description":"\u003cdiv class=\"product-single__description rte\"\u003e\n\u003cp\u003e\u003cstrong\u003eFE-AIO-EM | Single-phase CHNT DDSU666 smart meter with 100A external CT for accurate import\/export monitoring in Fox ESS systems over long distances.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-phase electronic energy meter (DDSU666) with Modbus RTU communication.\u003c\/li\u003e\n\u003cli\u003eIncludes external 100A CT clamp for non-invasive current measurement.\u003c\/li\u003e\n\u003cli\u003eHigh accuracy Class B active energy measurement (±1.0%).\u003c\/li\u003e\n\u003cli\u003eEssential for export limitation when inverter \u0026gt;30m from consumer unit.\u003c\/li\u003e\n\u003cli\u003eRS485 interface with 9600 baud rate for Fox ESS inverter integration.\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting (35mm) for standard distribution board installation.\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range -25°C to +55°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e220-240 V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5(80)A direct \/ 100A via CT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (±1.0% active energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485 Modbus RTU (9600 bps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD (voltage, current, power, energy, PF, frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 imp\/kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 × 89 × 74 mm (meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation \u0026amp; Application\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall meter and CT clamp at incoming mains supply position (consumer unit head).\u003c\/li\u003e\n\u003cli\u003eRS485 cable from meter to inverter (max recommended 1000m with screening).\u003c\/li\u003e\n\u003cli\u003eMeasures positive\/negative active energy, voltage, current, power factor and frequency.\u003c\/li\u003e\n\u003cli\u003eRequired for compliant zero-export installations with Fox hybrid\/AC\/AIO inverters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e FE-AIO-EM\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CHNT DDSU666 Single-Phase with 100A CT\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eReplaces CT clamp-only solutions for long cable runs, providing full electrical parameter monitoring and precise export control for Fox ESS energy storage systems.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Fox ESS","offers":[{"title":"Default Title","offer_id":62824980513117,"sku":"FE-AIO-EM","price":109.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/FoxESSCHINTDDSU6661phMeterforusewithFoxSinglePhaseInverters.webp?v=1765172306"},{"product_id":"fox-ess-3ph-energy-meter-chnt-dtsu666","title":"Fox ESS 3ph Energy Meter CHNT DTSU666","description":"\u003cdiv class=\"product-single__description rte\"\u003e\n\u003cp\u003e\u003cstrong\u003eFE-3PH-METER-CT | Three-phase CHINT DTSU666 smart meter with external CTs for accurate import\/export monitoring in Fox ESS three-phase systems.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThree-phase four-wire electronic energy meter (DTSU666) with Modbus RTU RS485.\u003c\/li\u003e\n\u003cli\u003eExternal CT clamps for non-invasive current measurement on each phase.\u003c\/li\u003e\n\u003cli\u003eClass B accuracy (±1.0%) for active energy per MID certification.\u003c\/li\u003e\n\u003cli\u003eMeasures voltage, current, power, PF, frequency and bi-directional energy per phase.\u003c\/li\u003e\n\u003cli\u003eEssential for zero-export control on three-phase Fox ESS hybrid\/AC inverters.\u003c\/li\u003e\n\u003cli\u003eCompact DIN-rail (4-module) design for consumer unit installation.\u003c\/li\u003e\n\u003cli\u003eBacklit LCD display cycling through all electrical parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3×230\/400 V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\/40mA via external CTs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eClass B (MID certified)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485 Modbus RTU (9600 bps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit LCD (voltage, current, power, energy, PF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 imp\/kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98 × 72 × 65 mm (4 DIN modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation \u0026amp; Application\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeter installs at main three-phase supply with CT clamps on L1, L2, L3 conductors.\u003c\/li\u003e\n\u003cli\u003eRS485 connection to Fox ESS three-phase inverter (screened cable up to 1000m).\u003c\/li\u003e\n\u003cli\u003eProvides real-time per-phase data for precise export limitation and energy management.\u003c\/li\u003e\n\u003cli\u003eRequired for compliant G100 three-phase installations with Fox ESS equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e FE-3PH-METER-CT\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CHINT DTSU666 3-Phase with External CTs\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eProfessional-grade three-phase metering solution for Fox ESS systems, delivering accurate multi-phase monitoring essential for commercial zero-export and advanced energy management applications.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Fox ESS","offers":[{"title":"Default Title","offer_id":62824994799965,"sku":"FE-3PH-METER-CT","price":179.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/FoxESSCHINTDDSU6663phMeterforusewithFoxThreePhaseInverters.jpg?v=1765172449"},{"product_id":"fox-ess-single-phase-eps-box-whole-home-back-up-box","title":"Fox ESS EPS-BOX-SP Single Phase Whole Home Backup Gateway","description":"\u003cdiv style=\"font-size:16px;font-family:Arial,Helvetica,sans-serif;color:#1a1a1a;max-width:900px;margin:0 auto;line-height:1.6;\"\u003e\n\n  \u003c!-- ── INTRO ─────────────────────────────────────────────────────── --\u003e\n  \u003cp style=\"margin:0 0 18px;\"\u003e\n    The \u003cstrong\u003eFox ESS EPS-BOX-SP (FE-EPS-BOX-SP)\u003c\/strong\u003e is a \u003cstrong\u003esingle-phase whole-home backup gateway\u003c\/strong\u003e that enables an existing Fox ESS hybrid inverter and battery system to power the \u003cstrong\u003eentire property\u003c\/strong\u003e — not just a handful of emergency sockets — during a grid outage. It sits between the utility supply, the Fox ESS inverter, and the household consumer unit. During normal operation it is transparent to the system. When the grid fails, it \u003cstrong\u003eautomatically isolates the property and restores power via battery and solar within 2–3 seconds\u003c\/strong\u003e. When the grid recovers, it reconnects seamlessly. The unit handles up to \u003cstrong\u003e100A output current\u003c\/strong\u003e, covers the full range of UK single-phase Fox ESS hybrid inverters and AC chargers, and comes in an \u003cstrong\u003eIP65-rated metal enclosure\u003c\/strong\u003e suitable for both indoor and sheltered outdoor installation.\n  \u003c\/p\u003e\n\n  \u003c!-- ── STAT STRIP ─────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin-bottom:20px;\"\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003e100 A\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eMax output current\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003e2–3 sec\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eTypical transfer time\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003eWhole home\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eAll circuits backed up\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003eIP65\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eMetal enclosure\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003eAutomatic\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eNo user intervention\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── RED INSTALLER CALLOUT ─────────────────────────────────────── --\u003e\n  \u003cdiv style=\"border-left:4px solid #c0392b;background:#fff5f5;padding:10px 16px;margin-bottom:14px;border-radius:0 6px 6px 0;\"\u003e\n    \u003cstrong style=\"color:#c0392b;\"\u003e⚠ Installer Note\u003c\/strong\u003e — Installation must be carried out by a \u003cstrong\u003equalified electrician\u003c\/strong\u003e registered with a competent persons scheme (NICEIC, NAPIT). The EPS-BOX-SP modifies the interaction between the property and the grid at the main supply point; work must comply with BS 7671 and any applicable DNO requirements. \u003cstrong\u003eThis is a system accessory — a compatible Fox ESS hybrid inverter and battery must already be installed or supplied alongside.\u003c\/strong\u003e The box does not generate or store energy itself.\n  \u003c\/div\u003e\n\n  \u003c!-- ── AMBER COMPATIBILITY CALLOUT ───────────────────────────────── --\u003e\n  \u003cdiv style=\"border-left:4px solid #f59e0b;background:#fff8e1;padding:10px 16px;margin-bottom:22px;border-radius:0 6px 6px 0;\"\u003e\n    \u003cstrong style=\"color:#b45309;\"\u003e⚡ Compatibility — Single Phase Only\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eCompatible with:\u003c\/strong\u003e Fox ESS H1-G2, KH Series, EVO, PowerQ single-phase hybrid inverters, and Fox ESS AC chargers.\u003cbr\u003e\n    \u003cstrong\u003eNot compatible with:\u003c\/strong\u003e Three-phase Fox ESS inverter systems (see the Fox ESS EPS-BOX-PRO \/ EPS-BOX-TP for three-phase applications). Backup performance is subject to inverter and battery sizing — sufficient battery capacity and inverter power rating must be available to meet the property's load during an outage.\n  \u003c\/div\u003e\n\n  \u003c!-- ── FEATURES GRID ──────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Features \u0026amp; Benefits\n  \u003c\/div\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(260px,1fr));gap:12px;background:#e6f4f3;padding:14px;border-radius:0 0 6px 6px;margin-bottom:22px;\"\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Whole-Home Backup — Every Circuit\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eTraditional EPS outputs from a hybrid inverter power only the \u003cstrong\u003einverter's own backup socket or a dedicated sub-board\u003c\/strong\u003e. The EPS-BOX-SP connects between the inverter and the main consumer unit, enabling the battery and solar system to power \u003cstrong\u003eall circuits in the property\u003c\/strong\u003e — heating, lighting, kitchen, EV charger (subject to inverter output and battery capacity) — during an outage. No rewiring of individual circuits is required.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Automatic Switchover — No User Action\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eWhen the grid supply fails, the EPS-BOX-SP \u003cstrong\u003eautomatically detects the loss of voltage, disconnects from the utility supply, and restores power from the Fox ESS inverter's EPS output\u003c\/strong\u003e — typically within 2–3 seconds. When grid power returns and is stable, the unit reconnects automatically. The homeowner does not need to flip switches, press buttons, or do anything.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ 100A Output — Handles Full UK Domestic Load\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eWith a \u003cstrong\u003emaximum output current of 100A\u003c\/strong\u003e at 220\/230\/240V single-phase, the EPS-BOX-SP can accommodate the main supply capacity of the vast majority of UK domestic properties — most of which are fused at 60A, 80A, or 100A at the service head. This means the backup gateway does not become a bottleneck that limits which circuits can be powered during an outage.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Grid-Compliant Isolation\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe EPS-BOX-SP provides \u003cstrong\u003eautomatic electrical isolation from the grid\u003c\/strong\u003e during backup operation — a requirement for any system operating in island mode in the UK. This protects DNO engineers working on the network from back-fed voltage from your battery system, and ensures the inverter is not damaged by a voltage conflict when the grid returns. It fulfils the islanding protection requirement of the Fox ESS system in a single box.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Integrated RS-485 Meter Communication\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe unit includes an \u003cstrong\u003eRS-485 communication interface\u003c\/strong\u003e and is designed to integrate with the Fox ESS system's metering and monitoring. This enables the \u003cstrong\u003eFoxESS Cloud platform and app\u003c\/strong\u003e to report backup status, track energy flows during outage periods, and allow the installer to configure switching behaviour via the inverter settings.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ IP65 Metal Enclosure — Indoor or Outdoor\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe \u003cstrong\u003eIP65-rated metal housing\u003c\/strong\u003e protects against dust ingress and water jet spray, making the unit suitable for installation in garages, utility rooms, outbuildings, and sheltered outdoor wall locations. Operating temperature range of \u003cstrong\u003e–25°C to +60°C\u003c\/strong\u003e ensures reliable performance through UK winter conditions without heating or climate control.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Retrofit Compatible\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe EPS-BOX-SP can be added to an \u003cstrong\u003eexisting Fox ESS single-phase hybrid inverter installation\u003c\/strong\u003e — it does not require a new inverter or battery to be installed. For homes with a Fox ESS H1-G2, KH, EVO, or PowerQ inverter and battery already fitted, the EPS-BOX-SP upgrades the system to whole-home backup without any other changes to the solar or storage hardware.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Silent, Maintenance-Free Cooling\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe EPS-BOX-SP uses \u003cstrong\u003enatural convection cooling\u003c\/strong\u003e — no fans, no moving parts, no noise. This makes it suitable for installation near living spaces and means there is no maintenance obligation beyond the periodic inspection appropriate for any electrical installation. No filters to clean, no components that wear out through normal operation.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- ── HOW IT WORKS ───────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    How It Works\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #c8e6e3;border-top:none;border-radius:0 0 6px 6px;padding:14px 16px;margin-bottom:22px;font-size:14px;\"\u003e\n    \u003cp style=\"margin:0 0 10px;\"\u003eThe EPS-BOX-SP connects between three points: the utility supply (grid), the Fox ESS inverter's EPS output, and the property's consumer unit (household loads).\u003c\/p\u003e\n    \u003cul style=\"margin:0;padding-left:20px;line-height:2.0;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eNormal operation:\u003c\/strong\u003e The grid supplies the property as normal. Solar and battery charge\/discharge via the Fox ESS inverter as usual. The EPS-BOX-SP is transparent — it does not affect normal system operation.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eGrid outage:\u003c\/strong\u003e The EPS-BOX-SP detects loss of grid voltage. It disconnects the property from the utility supply (isolating from the grid) and, after a short transfer delay of approximately 2–3 seconds, connects the consumer unit to the Fox ESS inverter's EPS output. The home is now powered by battery and solar.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eGrid restoration:\u003c\/strong\u003e When the grid returns and is stable, the EPS-BOX-SP automatically reconnects to the utility supply and returns to normal operation. No user action required.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── SPEC TABLE ─────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Technical Specifications\n  \u003c\/div\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:22px;font-size:14px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;width:42%;border-bottom:1px solid #c8e6e3;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eFox ESS\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003ePart Number \/ SKU\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eFE-EPS-BOX-SP \/ EPS-BOX-SP\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSingle-phase whole-home EPS backup gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e220 \/ 230 \/ 240 V AC, L \/ N \/ PE\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eRated Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eMax Output Current\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\u003cstrong\u003e100 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eTypical Transfer Time (Grid Failure)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eApproximately 2–3 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eRS-485 (for meter \/ Fox ESS system integration)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eCooling\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eNatural convection (fanless — silent)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–25°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e420 × 550 × 138.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eIngress Protection\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003eIP65\u003c\/strong\u003e (dust-tight, jet-water resistant)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eCompatible Inverters\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eFox ESS H1-G2, KH Series, EVO, PowerQ (single-phase only)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;\"\u003eCompatible AC Chargers\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;\"\u003eFox ESS AC charger range (single-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- ── FAQ ────────────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Frequently Asked Questions\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #c8e6e3;border-top:none;border-radius:0 0 6px 6px;margin-bottom:8px;\"\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eWhat is the difference between using the inverter's built-in EPS and adding an EPS-BOX-SP?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eFox ESS hybrid inverters have a built-in EPS (Emergency Power Supply) output — a dedicated socket or output terminal that provides backup power during an outage. However, this EPS output is separate from the main consumer unit — it only powers loads that are connected directly to it, typically a few sockets or a small sub-board. The \u003cstrong\u003eEPS-BOX-SP connects the inverter's EPS output to the whole property's consumer unit\u003c\/strong\u003e, so that every circuit in the home is backed up — not just a dedicated emergency circuit. Think of it as the missing link between an EPS-capable inverter and a whole-home backup capability.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#fff;\"\u003eWill every appliance in the house keep working during a power cut?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eThe EPS-BOX-SP enables backup power to reach every circuit, but what actually keeps running depends on two things: the \u003cstrong\u003einverter's EPS output power rating\u003c\/strong\u003e (how many watts it can supply in backup mode) and the \u003cstrong\u003ebattery's state of charge and capacity\u003c\/strong\u003e (how long it can sustain that output). For example, a Fox ESS H1-6.0kW inverter can deliver up to 6kW in EPS mode — enough to run lights, heating pump, fridge, TV, and many other appliances simultaneously. High-draw appliances like electric showers (8–10 kW) or electric ovens may exceed the inverter's EPS output and could trip the backup. Your installer can advise on load management based on your specific inverter and battery combination.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eIs there a risk of back-feeding the grid during backup operation?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eNo — this is exactly what the EPS-BOX-SP prevents. \u003cstrong\u003eDuring backup operation, it physically disconnects the property from the utility supply\u003c\/strong\u003e, meaning the inverter and battery cannot back-feed voltage onto the grid cable. This is a critical safety requirement: DNO engineers responding to a power cut must not encounter live voltage on cables they believe to be de-energised. The EPS-BOX-SP provides this isolation automatically as soon as a grid failure is detected, and maintains it until the grid is confirmed stable.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#fff;\"\u003eCan this be retrofitted to an existing Fox ESS installation?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eYes — the EPS-BOX-SP is designed for both new installations and \u003cstrong\u003eretrofit onto existing Fox ESS single-phase hybrid inverter systems\u003c\/strong\u003e. No changes to the inverter, batteries, or solar array are required. The installer will connect the EPS-BOX-SP between the existing inverter's EPS output and the household consumer unit. Confirm with your installer that the inverter firmware is up to date, as newer firmware versions may include improved EPS-BOX-SP integration features. Not all Fox ESS inverter models support the EPS-BOX-SP; check the compatibility list before ordering.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Fox ESS","offers":[{"title":"Default Title","offer_id":62825001451869,"sku":"FE-EPS-BOX-SP","price":520.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/FoxESSSinglePhaseEPSBox-WholeHomeBackUpBox.jpg?v=1765172813"},{"product_id":"shelly-pro-em-50-din-rail-50a-energy-monitor","title":"Shelly Pro EM-50 DIN Rail 50A Energy Monitor","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003e\u003cstrong\u003eShelly Pro EM-50 DIN Rail 50A Energy Monitor\u003c\/strong\u003e is a two-channel, single-phase energy meter designed for DIN rail mounting. It combines accurate power and energy monitoring with an integrated dry-contact relay, making it ideal for managing and automating loads in modern PV and smart-home installations.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-channel single-phase metering\u003c\/strong\u003e – measures two independent circuits on the same phase, ideal for tracking PV generation and household consumption or two key loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated relay with dry contacts\u003c\/strong\u003e – built-in relay output for controlling a contactor or external device based on measured power or automation logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLAN, Wi-Fi and Bluetooth connectivity\u003c\/strong\u003e – multiple communication options for secure, reliable integration into networks and smart-home systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-time monitoring\u003c\/strong\u003e – reports instantaneous voltage, current, active power and apparent power per channel, as well as accumulated energy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-quadrant measurement\u003c\/strong\u003e – measures import and export power, reactive power and energy, with optical LED pulse indication of energy usage; ideal for photovoltaic applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy Class B\u003c\/strong\u003e – complies with IEC 62053-21 Class B accuracy for reliable metering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal data storage\u003c\/strong\u003e – stores data in non-volatile memory for up to 60 days in 1-minute intervals, even without cloud connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo hub required\u003c\/strong\u003e – can be controlled directly via the Shelly Smart Control app and works with common home automation platforms and voice assistants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMonitoring \u0026amp; Communication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured parameters:\u003c\/strong\u003e voltage, current, active power, apparent power and accumulated energy per channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e Ethernet (LAN), Wi-Fi and Bluetooth for flexible integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart-home integration:\u003c\/strong\u003e compatible with Alexa, Home Assistant and other systems via open protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols \u0026amp; APIs:\u003c\/strong\u003e supports scripting, web hooks, MQTT, WebSocket, HTTPS, UDP, TLS, custom certificates and Modbus TCP.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHardware \u0026amp; Installation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail mountable for neat installation in consumer units and distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent rating:\u003c\/strong\u003e 50A per measurement channel (with appropriate current transformers or direct measurement, as specified by the manufacturer).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay output:\u003c\/strong\u003e dry-contact relay suitable for driving contactors to switch larger loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePV-ready design:\u003c\/strong\u003e suitable for monitoring PV systems, including import\/export and key loads like EV chargers or immersion heaters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring household consumption and PV generation on two separate circuits.\u003c\/li\u003e\n\u003cli\u003eControlling large loads (via contactors) such as immersion heaters, EV chargers or heat pumps based on measured power or tariffs.\u003c\/li\u003e\n\u003cli\u003eIntegrating detailed energy monitoring into smart-home platforms without needing a separate hub.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Shelly","offers":[{"title":"Default Title","offer_id":62931591070045,"sku":"EM-50","price":120.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/ShellyPro50AEnergyMeter-DINrail.jpg?v=1766078517"},{"product_id":"shelly-50a-current-clamp","title":"Shelly 50A Current Clamp","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003e\u003cstrong\u003eShelly 50A Current Clamp\u003c\/strong\u003e is a dedicated current transformer accessory for Shelly energy monitoring devices. It allows accurate, non-invasive measurement of AC current up to 50A, enabling precise tracking of energy consumption on monitored circuits.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 50A current range\u003c\/strong\u003e – designed to measure AC loads up to 50 amps on a single monitored conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh accuracy\u003c\/strong\u003e – monitoring accuracy within approximately 1%, suitable for detailed energy analysis and optimisation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with Shelly meters\u003c\/strong\u003e – works with Shelly energy monitoring devices (such as the Shelly Pro EM series) as the sensing element for one measurement channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-invasive measurement\u003c\/strong\u003e – clamp-on design allows installation around a live conductor without needing to disconnect wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupports up to two circuits (with device)\u003c\/strong\u003e – when paired with a dual-channel Shelly meter, enables monitoring of two separate circuits using two clamps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplication \u0026amp; Use\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-channel support\u003c\/strong\u003e – each 50A clamp provides measurement for one channel; two clamps are used for two-channel devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical loads:\u003c\/strong\u003e ideal for monitoring circuits such as immersion heaters, EV chargers, heat pumps, or whole-house feeds up to 50A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy retrofit\u003c\/strong\u003e – can be added to existing installations with suitable Shelly meters for upgraded monitoring without major rewiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstall around a single live conductor only; do not clamp around cables containing both live and neutral as this will cancel the measured current.\u003c\/li\u003e\n\u003cli\u003eEnsure the clamp is fully closed and securely latched to maintain accuracy and safety.\u003c\/li\u003e\n\u003cli\u003eAll work on electrical panels must be carried out by a competent person with power safely isolated where required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Shelly","offers":[{"title":"Default Title","offer_id":62931674136925,"sku":"Shelly-50A-Current","price":17.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/current-transformer-50A-shelly.webp?v=1766079466"},{"product_id":"shelly-mini-1pm-gen3-wifi-smart-switch","title":"Shelly Mini 1PM GEN3 WiFi Smart Switch","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003e\u003cstrong\u003eShelly Mini 1PM GEN3 Smart Switch\u003c\/strong\u003e is an ultra‑compact Wi‑Fi relay with built‑in power monitoring, designed to fit behind standard wall switches or sockets. It lets you automate lights and small appliances in minutes, with full remote control and energy monitoring via the Shelly app or your existing smart home system.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorld’s smallest relay switch\u003c\/strong\u003e – tiny form factor designed to fit behind almost any wall switch or socket backbox.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart on\/off control\u003c\/strong\u003e – remotely switch lights or small electrical appliances from anywhere via the Shelly Cloud app.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated power monitoring\u003c\/strong\u003e – real‑time measurement of power usage so you can track energy consumption and optimise loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit friendly\u003c\/strong\u003e – fits into existing installations without changing the visible switch or socket hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGEN3 platform with 8MB Shelly ESP processor\u003c\/strong\u003e – improved responsiveness, better power efficiency and support for new advanced features over time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Bluetooth onboarding\u003c\/strong\u003e – add the device quickly using Bluetooth via the Shelly Cloud app, then manage it over Wi‑Fi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSmart Home \u0026amp; Connectivity\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWi‑Fi connected\u003c\/strong\u003e – no hub required; connects directly to your 2.4 GHz Wi‑Fi network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly compatible\u003c\/strong\u003e – works with common smart home ecosystems and voice assistants via Shelly’s open APIs and integrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote access\u003c\/strong\u003e – control and monitor loads from anywhere, schedule automation and create scenes in the Shelly app.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomating lighting circuits while keeping your existing wall switches.\u003c\/li\u003e\n\u003cli\u003eSmart control and monitoring of small appliances such as lamps, fans or plug‑in heaters within the device’s rated load.\u003c\/li\u003e\n\u003cli\u003eAdding fine‑grained energy monitoring to individual circuits or appliances for efficiency tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for installation behind switches or sockets in a suitable backbox with enough depth and ventilation.\u003c\/li\u003e\n\u003cli\u003eAll wiring must be carried out by a competent person with the power safely isolated.\u003c\/li\u003e\n\u003cli\u003eEnsure the connected load does not exceed the relay’s rated current and power limits as specified by Shelly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Shelly","offers":[{"title":"Default Title","offer_id":62931741081949,"sku":"Shelly-Mini-1PM-G3","price":21.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/ShellyMini1PMGEN3WiFiSmartSwitch.webp?v=1766080143"},{"product_id":"shelly-gen-3-energy-meter-with-50a-ct-clamp","title":"Shelly Gen 3 Energy Meter with 50A CT Clamp","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003e\u003cstrong\u003eShelly Mini 1PM GEN3 Smart Switch\u003c\/strong\u003e is an ultra‑compact Wi‑Fi relay with built‑in power monitoring, designed to fit behind standard wall switches or sockets. It lets you automate lights and small appliances in minutes, with full remote control and energy monitoring via the Shelly app or your existing smart home system.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorld’s smallest relay switch\u003c\/strong\u003e – tiny form factor designed to fit behind almost any wall switch or socket backbox.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart on\/off control\u003c\/strong\u003e – remotely switch lights or small electrical appliances from anywhere via the Shelly Cloud app.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated power monitoring\u003c\/strong\u003e – real‑time measurement of power usage so you can track energy consumption and optimise loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit friendly\u003c\/strong\u003e – fits into existing installations without changing the visible switch or socket hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGEN3 platform with 8MB Shelly ESP processor\u003c\/strong\u003e – improved responsiveness, better power efficiency and support for new advanced features over time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Bluetooth onboarding\u003c\/strong\u003e – add the device quickly using Bluetooth via the Shelly Cloud app, then manage it over Wi‑Fi.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSmart Home \u0026amp; Connectivity\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWi‑Fi connected\u003c\/strong\u003e – no hub required; connects directly to your 2.4 GHz Wi‑Fi network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly compatible\u003c\/strong\u003e – works with common smart home ecosystems and voice assistants via Shelly’s open APIs and integrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote access\u003c\/strong\u003e – control and monitor loads from anywhere, schedule automation and create scenes in the Shelly app.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomating lighting circuits while keeping your existing wall switches.\u003c\/li\u003e\n\u003cli\u003eSmart control and monitoring of small appliances such as lamps, fans or plug‑in heaters within the device’s rated load.\u003c\/li\u003e\n\u003cli\u003eAdding fine‑grained energy monitoring to individual circuits or appliances for efficiency tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for installation behind switches or sockets in a suitable backbox with enough depth and ventilation.\u003c\/li\u003e\n\u003cli\u003eAll wiring must be carried out by a competent person with the power safely isolated.\u003c\/li\u003e\n\u003cli\u003eEnsure the connected load does not exceed the relay’s rated current and power limits as specified by Shelly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Shelly","offers":[{"title":"Default Title","offer_id":62931772539229,"sku":"Shelly-Gen3-50A-CT","price":115.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/ShellyGen3EnergyMeterwith50ACTClamp.webp?v=1766080592"},{"product_id":"shelly-ogemray-25a-smart-switch-for-immersion-control","title":"Shelly Ogemray SW40 25A Smart Switch Immersion Heater Control Solar Divert, WiFi, Bluetooth, Power Metering","description":"\u003cdiv style=\"font-size: 16px; font-family: 'Segoe UI',Helvetica,Arial,sans-serif; color: #222; background: transparent; max-width: 900px; line-height: 1.5;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.75; color: #333; margin: 0 0 18px;\"\u003eThe \u003cstrong\u003eOgemray SW40\u003c\/strong\u003e (SKU: Ogemray-25A) is a \u003cstrong\u003e25A WiFi smart relay with built-in power metering\u003c\/strong\u003e, made by Ogemray Technology and imported by \u003cstrong\u003eShelly Europe\u003c\/strong\u003e as part of the “Powered By Shelly” programme. Smart switch is the \u003cstrong\u003erecommended immersion heater control switch for Eleven Energy \/ Volta battery and solar systems\u003c\/strong\u003e: configured via the Eleven Energy app, it automatically diverts surplus solar generation into the immersion heater once the battery reaches its target state of charge — turning free electricity into hot water at no additional cost. Beyond the Eleven Energy ecosystem, the Ogemray SW40 is a fully-featured smart relay compatible with any home WiFi and the complete Shelly ecosystem: Home Assistant, Google Home, Amazon Alexa, Samsung SmartThings, MQTT, KNXnet\/IP and 200+ other platforms. \u003cstrong\u003eNo hub required. Operates completely locally without internet connection. WiFi 2.4 GHz + Bluetooth 4.2. Dimensions: 60 × 52.4 × 24 mm. Wall-mount anchors and bracket included.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(110px,1fr)); gap: 10px; margin-bottom: 24px;\"\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 19px; font-weight: 800; line-height: 1.1;\"\u003e25A 6kW\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003eMax load\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 19px; font-weight: 800; line-height: 1.1;\"\u003ePower Meter\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003eReal-time\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 19px; font-weight: 800; line-height: 1.1;\"\u003eNo hub\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003eWiFi direct\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 19px; font-weight: 800; line-height: 1.1;\"\u003eLocal first\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003eNo cloud needed\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 19px; font-weight: 800; line-height: 1.1;\"\u003e200+\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003ePlatform integrations\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 12px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 19px; font-weight: 800; line-height: 1.1;\"\u003e25A Scripts\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: .85; margin-top: 5px;\"\u003emJs scripting\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #fef2f2; border-left: 4px solid #dc2626; border-radius: 0 8px 8px 0; padding: 14px 18px; margin: 6px 0 16px; font-size: 15px; color: #7f1d1d;\"\u003e\n\u003cstrong\u003e⚠ Installation by a competent person required:\u003c\/strong\u003e The Ogemray SW40 is a \u003cstrong\u003emains-voltage device switching up to 25A\u003c\/strong\u003e. All wiring must be carried out by a suitably qualified electrician in accordance with \u003cstrong\u003eBS 7671\u003c\/strong\u003e 18th Edition wiring regulations. Appropriate isolation, fusing and protection devices must be in place before connection. Do not connect loads exceeding 25A \/ 6,000W. The device is rated for \u003cstrong\u003eindoor use only\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv style=\"background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 8px 8px 0; padding: 14px 18px; margin: 6px 0 16px; font-size: 15px; color: #005c54;\"\u003e\n\u003cstrong\u003eℹ Eleven Energy ecosystem — this device also works standalone with any WiFi network:\u003c\/strong\u003e This listing is optimised for the \u003cstrong\u003eEleven Energy \/ Volta solar battery ecosystem\u003c\/strong\u003e, where the Ogemray SW40 acts as a solar divert switch controlled via the Eleven Energy app. However, the underlying device is a full \u003cstrong\u003eShelly “Powered By Shelly”\u003c\/strong\u003e product: it connects to any home WiFi network and is fully compatible with the Shelly Cloud app, Home Assistant, Google Home, Amazon Alexa, Samsung SmartThings and 200+ other platforms. It operates completely locally without cloud access.\u003c\/div\u003e\n\u003cdiv style=\"background: #f0f9f8; border: 1px solid #cde3e1; border-radius: 8px; padding: 18px 22px; margin: 0 0 22px;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 12px;\"\u003eThe solar divert case: why heating water with surplus solar is free money\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.75;\"\u003eA typical UK solar PV system generates more power than the household uses on summer afternoons. Without a smart divert switch, this excess is exported to the grid at the SEG rate (typically 3 – 15p\/kWh). With an Ogemray SW40 in solar divert mode, once the Volta battery reaches its target SoC, the Eleven Energy app commands the SW40 to switch on the immersion heater. A \u003cstrong\u003e3 kW immersion\u003c\/strong\u003e running for 2 hours on surplus solar uses \u003cstrong\u003e6 kWh of otherwise-exported electricity\u003c\/strong\u003e — worth approximately \u003cstrong\u003e£1.50 at 25p\/kWh\u003c\/strong\u003e if it had been bought from the grid. Over a year, a well-configured solar divert system on a typical UK home can provide \u003cstrong\u003efree hot water for 6 – 8 months\u003c\/strong\u003e, reducing or eliminating immersion heater electricity costs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eHow the Ogemray SW40 Works as a Solar Divert Switch\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 13px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 13px; font-weight: 800; color: #fff;\"\u003e1\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eWire the SW40 between the consumer unit and the immersion heater\u003c\/strong\u003eConnect the supply live and neutral, and the immersion circuit live and neutral to the device. Use the switched live terminal to feed the immersion heater. All wiring by a qualified electrician; appropriate fusing required.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 13px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 13px; font-weight: 800; color: #fff;\"\u003e2\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePair with the Eleven Energy app via Bluetooth\u003c\/strong\u003eOpen the Eleven Energy app, add the SW40 as a device. Bluetooth connectivity (range up to 10m indoors) makes pairing fast and simple without needing to configure WiFi credentials manually first.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 13px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 13px; font-weight: 800; color: #fff;\"\u003e3\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eConfigure the solar divert automation\u003c\/strong\u003eIn the Eleven Energy app, set the automation rule: when the Volta battery state of charge reaches the target level (e.g. 95 %), and solar generation exceeds household demand, switch on the immersion heater.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 13px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 13px; font-weight: 800; color: #fff;\"\u003e4\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eThe switch operates automatically from that point\u003c\/strong\u003eThe Ogemray SW40’s power meter confirms the immersion is drawing power. When solar generation drops (cloud cover, evening), the Eleven Energy app commands the switch off. Built-in overpower protection provides a safety backup.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 13px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 13px; font-weight: 800; color: #fff;\"\u003e5\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eMonitor energy usage in the app\u003c\/strong\u003eThe built-in power meter logs real-time and historical consumption. See exactly how many kWh have been diverted into the immersion in daily, weekly and monthly views.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #888; margin: 8px 0 0;\"\u003eWithout Eleven Energy: the same automation logic can be built independently using the Shelly Cloud app, Home Assistant, or any MQTT\/webhook-capable automation platform.\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e25A \/ 6kW Rating — Handles Any UK Domestic Immersion or Resistive Load\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe SW40 is rated for \u003cstrong\u003e25A continuous switching at 240V AC\u003c\/strong\u003e, giving a maximum load of 6,000W. Standard UK immersion heaters draw 3 kW on a 13 A circuit. The SW40’s 25A rating means it has a substantial safety margin for a 3 kW immersion (12 A draw vs 25 A rated), and is also suitable for larger 6 kW dual-element immersions (25 A), electric panel heaters, radiant floor heating elements, and other resistive loads within the rating. The relay is a \u003cstrong\u003esingle switched output\u003c\/strong\u003e — not a potential-free (dry contact) relay — so it switches the live supply directly. Large terminals accommodate the heavy-gauge cable appropriate for 25A circuits.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\u003cspan style=\"font-size: 13px\"\u003e\u003cspan style=\"background-color: rgb(0, 131, 119)\"\u003e\u003cspan style=\"color: rgb(255, 255, 255)\"\u003e25A continuous240V AC6,000W maxLarge terminals\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eBuilt-In Power Metering — Voltage, Current, Power and Energy\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe Ogemray SW40 monitors the connected load in real time: \u003cstrong\u003evoltage, current draw, instantaneous power (W) and cumulative energy (kWh)\u003c\/strong\u003e. For solar divert applications, this serves two purposes: (1) confirming the immersion is actually drawing power after the switch closes (not just the switch being on), and (2) tracking how many kWh have been diverted from surplus solar into the hot water tank over time. Historical data is stored in the Shelly Cloud and Eleven Energy app for daily, weekly and monthly energy analysis.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\u003cspan style=\"font-size: 13px\"\u003e\u003cspan style=\"background-color: rgb(0, 131, 119)\"\u003e\u003cspan style=\"color: rgb(255, 255, 255)\"\u003eVoltage, current, power, energyReal-time monitoringCloud history\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eNo Hub Required — Fully Local Operation, WiFi + Bluetooth\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe SW40 connects \u003cstrong\u003edirectly to your home WiFi network at 2.4 GHz\u003c\/strong\u003e (802.11 b\/g\/n) — no Shelly Hub, Zigbee gateway or proprietary bridge needed. Bluetooth 4.2 (range up to 10 m indoors) is used for initial pairing and direct local control. Critically, the device has a \u003cstrong\u003ebuilt-in web server\u003c\/strong\u003e: all primary functions — switching, scheduling, automation rules, scripting — operate entirely locally on the device, regardless of whether the internet or Shelly Cloud is available. Schedules and automations programmed into the device continue to run even if your broadband connection goes down.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\u003cspan style=\"font-size: 13px\"\u003e\u003cspan style=\"background-color: rgb(0, 131, 119)\"\u003e\u003cspan style=\"color: rgb(255, 255, 255)\"\u003eNo hub requiredWiFi 2.4 GHz directBluetooth 4.2 setup100 % local operation\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eOvervoltage, Overcurrent, Overpower + Internal Temperature Protection\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eFour hardware protection mechanisms protect against fault conditions: \u003cstrong\u003eovervoltage protection\u003c\/strong\u003e trips if the supply voltage exceeds safe limits; \u003cstrong\u003eovercurrent protection\u003c\/strong\u003e opens the relay if current exceeds the set threshold; \u003cstrong\u003eoverpower protection\u003c\/strong\u003e cuts the load if wattage exceeds the configured limit (configurable in the app); and an \u003cstrong\u003einternal temperature sensor\u003c\/strong\u003e triggers automatic shutdown if the device overheats. These protections can also trigger notifications or webhooks via the app, allowing fault alerts to be sent without manual monitoring.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\u003cspan style=\"font-size: 13px\"\u003e\u003cspan style=\"background-color: rgb(0, 131, 119)\"\u003e\u003cspan style=\"color: rgb(255, 255, 255)\"\u003eOvervoltageOvercurrentOverpowerThermal cutoff\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eFull Shelly Ecosystem — Home Assistant, MQTT, Scripting, 200+ Integrations\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eAs a “Powered By Shelly” device, the SW40 has the complete Shelly feature set: \u003cstrong\u003eMQTT\u003c\/strong\u003e (standard IoT messaging protocol), \u003cstrong\u003ewebhooks\u003c\/strong\u003e (up to 20 with 5 URLs each), \u003cstrong\u003eUDP\u003c\/strong\u003e, \u003cstrong\u003eKNXnet\/IP\u003c\/strong\u003e (building automation), \u003cstrong\u003eModbus\u003c\/strong\u003e, and \u003cstrong\u003emJs scripting\u003c\/strong\u003e for custom local automation logic. It integrates with \u003cstrong\u003eHome Assistant\u003c\/strong\u003e natively (ideal for combining with solar inverter data for custom divert logic), Google Home, Amazon Alexa, Samsung SmartThings, Athom Homey, and 200+ additional partner platforms. Up to 20 schedules can be programmed directly into the device.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\u003cspan style=\"font-size: 13px\"\u003e\u003cspan style=\"background-color: rgb(0, 131, 119)\"\u003e\u003cspan style=\"color: rgb(255, 255, 255)\"\u003eHome AssistantMQTT + KNXnet\/IPmJs scripting20 schedules\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eEleven Energy App Integration — Solar Divert, Battery SoC Triggers\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eFor Eleven Energy (Volta) systems, the Ogemray SW40 is configured through the \u003cstrong\u003eEleven Energy app\u003c\/strong\u003e rather than — or in addition to — the standard Shelly Cloud app. Bluetooth onboarding connects the device to the Eleven ecosystem quickly. The automation capabilities include: \u003cstrong\u003esolar divert\u003c\/strong\u003e (switch on when surplus PV power is available), \u003cstrong\u003ebattery SoC triggers\u003c\/strong\u003e (only divert once battery is above threshold), \u003cstrong\u003escheduled immersion heating\u003c\/strong\u003e (e.g. Economy 7 or Octopus Go off-peak periods), and coordination with other Eleven Energy\/Volta devices for whole-home energy optimisation.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\u003cspan style=\"font-size: 13px\"\u003e\u003cspan style=\"background-color: rgb(0, 131, 119)\"\u003e\u003cspan style=\"color: rgb(255, 255, 255)\"\u003eEleven Energy appSolar divert triggerBattery SoC automationOff-peak scheduling\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 28px; height: 28px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg width=\"13\" height=\"13\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#fff\" stroke-width=\"3\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eCompact 60 × 52.4 × 24 mm — Wall-Mount Anchors and Bracket Included\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eAt just 60 × 52.4 × 24 mm, the SW40 fits inside a standard \u003cstrong\u003e35mm back-box \/ pattress box\u003c\/strong\u003e near the immersion heater or consumer unit. Wall-mount anchors and a bracket are supplied in the box for surface mounting without a back-box where appropriate. The compact size means it can also be installed inside a suitable enclosure adjacent to an existing consumer unit or fused spur. Device self-consumption is under 1.2W at idle.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\u003cspan style=\"font-size: 13px\"\u003e\u003cspan style=\"background-color: rgb(0, 131, 119)\"\u003e\u003cspan style=\"color: rgb(255, 255, 255)\"\u003e60 × 52.4 × 24 mmWall-mount anchors included\u0026lt;1.2W self-consumption\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eWiring Overview (Qualified Electrician Only)\u003c\/div\u003e\n\u003cdiv style=\"background: #fff8e1; border-left: 4px solid #d97706; border-radius: 0 8px 8px 0; padding: 14px 18px; margin: 6px 0 16px; font-size: 15px; color: #92400e;\"\u003e\n\u003cstrong\u003e⚠ All wiring must be by a suitably qualified electrician.\u003c\/strong\u003e The following is a conceptual overview only. Refer to the official Ogemray SW40 user manual for the wiring diagram. Ensure all circuits are de-energised and isolated before any wiring work. A dedicated fused spur rated for the load is required. The SW40 is \u003cstrong\u003enot suitable for motor loads\u003c\/strong\u003e — use it with \u003cstrong\u003eresistive loads only\u003c\/strong\u003e (immersion heaters, panel heaters).\u003c\/div\u003e\n\u003cp style=\"font-size: 15px; color: #444; line-height: 1.75; margin: 0 0 14px;\"\u003eThe Ogemray SW40 is wired in-line on the immersion heater circuit. It has \u003cstrong\u003esupply side terminals\u003c\/strong\u003e (live in, neutral in) and \u003cstrong\u003eload side terminals\u003c\/strong\u003e (switched live out, neutral out). The switched live out feeds the immersion heater’s live terminal. Neutral is passed through unswitched. Typical installation for a 3 kW immersion on a dedicated 13 A circuit:\u003c\/p\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 10px 14px; background: #e6f4f3; border-left: 3px solid #008377; border-radius: 0 5px 5px 0; margin-bottom: 6px; font-size: 14px; color: #444;\"\u003e\n\u003cstrong\u003e1.\u003c\/strong\u003e Isolate the immersion heater circuit at the consumer unit fuse\/MCB.\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 10px 14px; background: #f8f8f8; border-left: 3px solid #008377; border-radius: 0 5px 5px 0; margin-bottom: 6px; font-size: 14px; color: #444;\"\u003e\n\u003cstrong\u003e2.\u003c\/strong\u003e Install the SW40 inside an appropriate enclosure near the immersion or CU, secured with the supplied wall-mount bracket.\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 10px 14px; background: #e6f4f3; border-left: 3px solid #008377; border-radius: 0 5px 5px 0; margin-bottom: 6px; font-size: 14px; color: #444;\"\u003e\n\u003cstrong\u003e3.\u003c\/strong\u003e Connect the incoming live (from CU) to the L-in terminal; incoming neutral to N-in terminal.\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 10px 14px; background: #f8f8f8; border-left: 3px solid #008377; border-radius: 0 5px 5px 0; margin-bottom: 6px; font-size: 14px; color: #444;\"\u003e\n\u003cstrong\u003e4.\u003c\/strong\u003e Connect the outgoing switched live (to immersion heater) from the L-out terminal; outgoing neutral to N-out terminal.\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 10px 14px; background: #e6f4f3; border-left: 3px solid #008377; border-radius: 0 5px 5px 0; margin-bottom: 6px; font-size: 14px; color: #444;\"\u003e\n\u003cstrong\u003e5.\u003c\/strong\u003e Ensure earth continuity is maintained on the circuit (not through the SW40).\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 12px; align-items: flex-start; padding: 10px 14px; background: #f8f8f8; border-left: 3px solid #008377; border-radius: 0 5px 5px 0; margin-bottom: 6px; font-size: 14px; color: #444;\"\u003e\n\u003cstrong\u003e6.\u003c\/strong\u003e Restore power and pair with the Eleven Energy or Shelly Cloud app via Bluetooth.\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #888; margin: 10px 0 0;\"\u003eFull wiring diagram is in the Ogemray SW40 user manual (also available via shelly.link\/Ogemray25A).\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 24px;\"\u003e\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: 'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eProduct Identity\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eFull model name\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eOgemray SW40 PbS (Powered By Shelly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eShenzhen Ogemray Technology Co., Ltd.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eImported by\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eShelly Europe Ltd., Sofia, Bulgaria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e110 – 240 V AC ±10 %, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMax switching voltage\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMax switching current\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMax switching power\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e6,000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eDevice self-consumption\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e\u0026lt;1.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eChannels\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e1 (single switched output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eRelay type\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eSwitched output — not potential-free \/ dry contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eMeasurements and Protection\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePower measurement\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eYes — voltage, current, power (W), energy (kWh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eOvervoltage protection\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eOvercurrent protection\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eOverpower protection\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eYes (configurable threshold)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eInternal temperature sensor\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eYes — auto cutoff on overtemperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eConnectivity\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eWiFi\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e2.4 GHz 802.11 b\/g\/n · RF \u0026lt; 20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eWiFi range\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eUp to 50 m outdoors \/ 30 m indoors (environment dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eBluetooth\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e4.2 · RF \u0026lt; 4 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eBluetooth range\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eUp to 30 m outdoors \/ 10 m indoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eHub required\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eNo — direct WiFi connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eAutomation and Integration\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eSchedules\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eUp to 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eWebhooks\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eUp to 20 (5 URLs per hook)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMQTT\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eYes (with TLS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eUDP\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eKNXnet\/IP\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eModbus\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eScripting\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eYes — mJs (micro-JavaScript)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eHTTP \/ WebSocket\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eYes (with TLS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eShelly Cloud app\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eiOS and Android — remote monitoring and control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eLocal web interface\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eYes — at device IP or 192.168.33.1 via access point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eThird-party integrations\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e200+ platforms: Home Assistant, Google Home, Alexa, SmartThings, Homey etc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eEleven Energy app\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eYes — solar divert, battery SoC triggers, scheduling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003ePhysical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eDimensions (H × W × L)\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e60 × 52.4 × 24 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eWall-mount anchors and bracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eEnvironmental\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e−20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e30 – 70 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eEnvironment\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eIndoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: .06em; text-transform: uppercase;\"\u003eCompliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eDirectives\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eRED 2014\/53\/EU · LVD 2014\/35\/EU · EMC 2014\/30\/EU · RoHS 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: .05em;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eDo I need an Eleven Energy system to use this switch?\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eNo. The Ogemray SW40 is a full Shelly “Powered By Shelly” device that works with any home WiFi network. Without an Eleven Energy system, you can control it via the \u003cstrong\u003eShelly Cloud app\u003c\/strong\u003e (iOS\/Android), use \u003cstrong\u003eHome Assistant\u003c\/strong\u003e for advanced solar divert automation (integrating with your inverter’s data via Modbus or API), set fixed \u003cstrong\u003eschedules\u003c\/strong\u003e for off-peak immersion heating, or create \u003cstrong\u003ewebhook\/MQTT automations\u003c\/strong\u003e with any compatible platform. The Eleven Energy integration is an additional layer for customers who also have a Volta\/Eleven Energy battery system.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eCan I use this to control a 6kW dual-element immersion heater?\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eA dual-element 6kW immersion heater draws approximately 25A at 240V. The Ogemray SW40 is rated for exactly 25A, which means a 6kW dual-element immersion is at the device’s maximum rated current. This is within specification, but it is good practice to keep continuous loads below 80 % of a relay’s rated capacity for longevity. For a 6kW immersion running continuously for extended periods, a 32A-rated alternative may be more appropriate. For a standard single-element 3kW immersion (13A draw), the SW40 has substantial headroom and is an ideal match.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eDoes this work with Home Assistant for solar divert without Eleven Energy?\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eYes. The Ogemray SW40 integrates with Home Assistant via the \u003cstrong\u003eShelly integration\u003c\/strong\u003e (available in HACS or as a standard integration). This exposes the switch state, power reading, energy data and control as entities in Home Assistant. You can then build automation in Home Assistant to divert solar: when PV generation exceeds household consumption by a threshold amount (read from your inverter’s Modbus or API), turn on the immersion switch. This approach is popular with installers using Solis, SolaX and other inverters that expose generation data via Modbus or local API.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eDoes it work without an internet connection?\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eYes. The Ogemray SW40 has a \u003cstrong\u003ebuilt-in web server\u003c\/strong\u003e that provides all primary functions locally, including switching, schedules, automation rules and scripting. If your broadband connection goes down, schedules and programmed automations continue to run on the device. Remote access via the Shelly Cloud app or Eleven Energy app requires an internet connection, but local control via the device’s web interface at its IP address on the home network does not.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhat load types can I control with the Ogemray SW40?\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eThe Ogemray SW40 is suitable for \u003cstrong\u003eresistive loads\u003c\/strong\u003e: immersion heaters, electric panel heaters, radiant floor heating elements, electric towel rails, resistive space heaters. It is \u003cstrong\u003enot recommended for motor loads\u003c\/strong\u003e (pumps, compressors, fans) because motor starts cause current inrush that can damage relay contacts rated for resistive switching. It is also not suitable for dimming, phase-cut control of heating elements, or any load requiring a potential-free (dry contact) relay — the SW40 is a switched live output, not a volt-free contact.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\u003cdetails\u003e\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eHow does the power metering help with solar divert optimisation?\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eThe power meter lets you verify that the solar divert is working correctly and quantify the savings. With the switch in divert mode, you can confirm the immersion is drawing the expected 3 kW (not open-circuit or short-circuit), see cumulative kWh diverted into the hot water tank per day\/week\/month, and set overpower alerts if the immersion draws more than expected (which could indicate a wiring fault or element failure). Historical energy data in the Shelly Cloud and Eleven Energy app lets you calculate the carbon and cost value of the diverted solar energy.\u003c\/div\u003e\u003c\/details\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Shelly","offers":[{"title":"Default Title","offer_id":62931819987293,"sku":"Ogemray-25A","price":39.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/ShellyOgemray25Asmartswitchforimmersioncontrol.webp?v=1766081273"},{"product_id":"shelly-smart-plug-uk-13a","title":"Shelly Smart Plug - UK 13A","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003e\u003cstrong\u003eOgemray SW40 25A Smart Switch for Immersion Control\u003c\/strong\u003e is a high‑current smart switch designed to control immersion heaters and other large loads up to 25A \/ 6000W. It integrates with the Eleven Energy app for intelligent control, including using excess solar generation to heat water once the battery is full.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e25A \/ 6kW rated output\u003c\/strong\u003e – suitable for controlling immersion heaters and other sizeable resistive loads on single‑phase supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt‑in power metering\u003c\/strong\u003e – measures real‑time power and energy usage so you can see exactly how much electricity the immersion or load is using.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart integration with Eleven Energy\u003c\/strong\u003e – controlled via the Eleven Energy app, enabling coordinated operation with Volta batteries, inverters and PV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar excess divert\u003c\/strong\u003e – can be configured so that surplus solar (once the battery is full) is automatically diverted into the immersion heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Bluetooth onboarding\u003c\/strong\u003e – Bluetooth connectivity allows fast and simple pairing with the Eleven app before moving to Wi‑Fi control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eControl \u0026amp; Connectivity\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eApp control:\u003c\/strong\u003e full on\/off control, scheduling and automation through the Eleven Energy app.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScheduling:\u003c\/strong\u003e set time‑based programmes (e.g. off‑peak heating, timed boosts).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation:\u003c\/strong\u003e link operation to solar production, battery state of charge or other system conditions where supported by the Eleven ecosystem.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWiring \u0026amp; Installation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple wiring:\u003c\/strong\u003e connect the supply live and neutral and the immersion circuit live and neutral to the device; use the switched live terminal to feed the immersion heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad type:\u003c\/strong\u003e designed primarily for resistive loads such as immersion heaters; ensure the connected load does not exceed 25A \/ 6000W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e suitable for installation near the immersion heater or consumer unit in an appropriate enclosure or pattress box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation requirements:\u003c\/strong\u003e all wiring must be carried out by a competent person, with isolation and protective devices sized according to local regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eImmersion heater control in homes with PV and battery storage, using surplus solar for hot water.\u003c\/li\u003e\n\u003cli\u003eSmart control of other high‑power resistive loads (within rating) such as panel heaters or electric towel rails.\u003c\/li\u003e\n\u003cli\u003eSystems where integration with Eleven Energy monitoring and automation is required for whole‑home optimisation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Shelly","offers":[{"title":"Default Title","offer_id":62931866779997,"sku":"Shelly-plug-UK","price":27.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Shelly-Plus-Plug-UK-main-image.webp?v=1766081498"},{"product_id":"ecoflow-power-insight-home-energy-monitor","title":"EcoFlow Power Insight Home Energy Monitor","description":"\u003c!-- SEO Product Name: EcoFlow PowerInsight Home Energy Monitor | 10.1-Inch Touchscreen Energy Manager --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#2B2B2B; line-height:1.6; font-family:Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eThe \u003cstrong\u003eEcoFlow PowerInsight Home Energy Monitor\u003c\/strong\u003e is a dedicated \u003cstrong\u003e10.1-inch touchscreen\u003c\/strong\u003e display that gives a clear, at-a-glance view of your home's solar generation, battery status and electricity consumption. Rather than relying on a phone app, PowerInsight acts as a permanent wall-mounted or countertop energy hub, showing real-time and historical data by \u003cstrong\u003eday, month or year\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eBeyond monitoring, PowerInsight is a \u003cstrong\u003esmart home control hub\u003c\/strong\u003e. With built-in \u003cstrong\u003eMatter support\u003c\/strong\u003e and compatibility with EcoFlow Smart Plugs, it lets you control connected appliances, heaters, heat pumps, thermostats, EV chargers and lighting from the same screen. A built-in \u003cstrong\u003etemperature and humidity sensor\u003c\/strong\u003e also allows it to auto-adjust connected climate devices based on the actual conditions in your home, rather than third-party weather data alone.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:20px -4px 24px -4px;\"\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 10px; border-radius:8px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e10.1\"\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.92;\"\u003eTouchscreen Display\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 10px; border-radius:8px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e1280 x 800\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.92;\"\u003eScreen Resolution\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 10px; border-radius:8px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eMatter\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.92;\"\u003eSmart Home Protocol\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 10px; border-radius:8px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e600 g\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.92;\"\u003eApprox. Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 10px; border-radius:8px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e3000 mAh\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.92;\"\u003eBackup Battery\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#FFFFFF; text-align:center; padding:16px 10px; border-radius:8px; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eWi-Fi \u0026amp; BT 5.0\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.92;\"\u003eConnectivity\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFF6E5; border-left:4px solid #E0942A; border-radius:0 8px 8px 0; padding:14px 18px; margin:10px 0 18px 0; font-size:15px; color:#2B2B2B;\"\u003e\n\u003cstrong\u003ePlease Note:\u003c\/strong\u003e PowerInsight is a \u003cstrong\u003ehome energy display and smart home hub\u003c\/strong\u003e, not a standalone metering device — it does not include CT clamps of its own. It draws its energy data from a compatible EcoFlow system (such as PowerOcean, DELTA Pro, or a connected EcoFlow smart meter) via the EcoFlow ecosystem, rather than measuring current directly at the consumer unit.\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; letter-spacing:0.04em; text-transform:uppercase; padding:10px 16px; border-radius:6px; margin:28px 0 14px 0;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 -4px 20px -4px;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eDedicated 10.1\" Touchscreen\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eA \u003cstrong\u003elarge, interactive display\u003c\/strong\u003e purpose-built for home energy monitoring, offering a clearer and more convenient experience than checking a phone app.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eFull Energy Data at a Glance\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eView \u003cstrong\u003esolar power generation\u003c\/strong\u003e, \u003cstrong\u003ehome energy consumption and sources\u003c\/strong\u003e, and \u003cstrong\u003ebattery charge\/discharge\u003c\/strong\u003e in real time, or broken down by day, month or year.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eMatter-Enabled Smart Home Control\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eA built-in \u003cstrong\u003eMatter gateway\u003c\/strong\u003e lets PowerInsight connect and control a wider range of third-party smart home devices than a phone app alone, alongside EcoFlow Smart Plugs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eIndoor Temperature \u0026amp; Humidity Sensing\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eBuilt-in \u003cstrong\u003etemperature and humidity sensors\u003c\/strong\u003e allow PowerInsight to automatically adjust connected heating and cooling based on real indoor conditions, not just forecast data.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eAutomated Daily Routines\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eModes such as \u003cstrong\u003eAway Mode\u003c\/strong\u003e and scheduled pre-heating let the system automatically manage lights, heating and appliances around your daily routine.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eFlexible Mounting\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eCan be \u003cstrong\u003ewall-mounted\u003c\/strong\u003e using the supplied bracket and fixings, or placed on a flat surface using a separate stand (stand not included).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; letter-spacing:0.04em; text-transform:uppercase; padding:10px 16px; border-radius:6px; margin:28px 0 14px 0;\"\u003eWhat's in the Box\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 -4px 20px -4px;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003ePowerInsight Unit\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eThe 10.1-inch touchscreen home energy monitor and smart home hub.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eWall Bracket\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eFor fixed wall installation of the display.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eFixings\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003e4x screws (4×30mm) and 4x wall anchors (Ø6×27mm) for wall mounting.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003ePower Cable\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eUSB-C to USB-C cable for mains power connection.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eQuick Start Guide \u0026amp; Warranty Card\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eSetup instructions and warranty documentation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; letter-spacing:0.04em; text-transform:uppercase; padding:10px 16px; border-radius:6px; margin:28px 0 14px 0;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; overflow:hidden; margin-bottom:20px;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13px; letter-spacing:0.04em; text-transform:uppercase; padding:9px 14px;\"\u003eGeneral\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eManufacturer\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eEcoFlow\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eProduct Type\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eHome Energy Monitor \u0026amp; Smart Home Hub\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eDimensions (H×W×D)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003e244.4 × 158.6 × 12.6 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eWeight\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eApprox. 600 g\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eColour\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eBlack\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eControls\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003ePower on\/off button\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13px; letter-spacing:0.04em; text-transform:uppercase; padding:9px 14px;\"\u003eDisplay\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eScreen Size\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003e10.1 inch\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003ePanel Type\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eIPS\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eResolution\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003e1280 × 800 pixels\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eTouch\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003e10-point multi-touch\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13px; letter-spacing:0.04em; text-transform:uppercase; padding:9px 14px;\"\u003ePerformance \u0026amp; Memory\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eProcessor\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eMT8168\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eStorage (ROM)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003e16 GB\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eMemory (RAM)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003e2 GB\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13px; letter-spacing:0.04em; text-transform:uppercase; padding:9px 14px;\"\u003eBattery \u0026amp; Charging\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eBackup Battery\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003e3000 mAh\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eCharging\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003e5V\/2A, Pogo Pin charger; USB-C to USB-C power cable supplied\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13px; letter-spacing:0.04em; text-transform:uppercase; padding:9px 14px;\"\u003eConnectivity\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eWireless LAN\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003e802.11 a\/b\/g\/n\/ac, 2.4GHz \u0026amp; 5GHz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eBluetooth\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eBluetooth 5.0\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eSmart Home Protocol\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eMatter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13px; letter-spacing:0.04em; text-transform:uppercase; padding:9px 14px;\"\u003eSensors\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#2B2B2B;\"\u003eOnboard Sensors\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#2B2B2B;\"\u003eTemperature and humidity sensor, ambient light sensor, proximity sensor\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; letter-spacing:0.04em; text-transform:uppercase; padding:10px 16px; border-radius:6px; margin:28px 0 14px 0;\"\u003eCompatible EcoFlow Ecosystem\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 -4px 20px -4px;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eEcoFlow PowerOcean (Three-Phase)\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eA premium 3-phase modular home solar solution for whole-house power independence.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eEcoFlow PowerOcean DC Fit\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eAn easy PV-coupled retrofit battery storage solution for existing solar panel systems.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eEcoFlow DELTA Pro\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eA portable home battery power station with an expandable ecosystem.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eEcoFlow PowerPulse\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eAn EV charging solution that uses solar power and surplus battery energy for charging.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eEcoFlow Smart Plug\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eA compact Wi-Fi socket providing energy monitoring and smart control of individual appliances.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eMatter-Compatible Devices\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eHeaters, heat pumps, thermostats, smart door locks, smart switches and lighting, subject to Matter protocol support.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; letter-spacing:0.04em; text-transform:uppercase; padding:10px 16px; border-radius:6px; margin:28px 0 14px 0;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eDoes PowerInsight include its own CT clamps for metering?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eNo. PowerInsight is a \u003cstrong\u003edisplay and smart home hub\u003c\/strong\u003e — it visualises and manages energy data from a connected EcoFlow system (such as PowerOcean or DELTA Pro), rather than measuring current itself via CT clamps.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eCan I control other smart home devices with PowerInsight?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eYes. PowerInsight includes a built-in \u003cstrong\u003eMatter gateway\u003c\/strong\u003e, allowing it to connect and control Matter-compatible smart home devices, in addition to EcoFlow Smart Plugs.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eHow is PowerInsight different from using the EcoFlow phone app?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003ePowerInsight offers a \u003cstrong\u003elarger, dedicated 10.1-inch touchscreen\u003c\/strong\u003e for a clearer view of your energy data, plus \u003cstrong\u003ebuilt-in temperature and humidity sensors\u003c\/strong\u003e for more accurate climate control — capabilities not available from a phone-based app alone.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eHow is PowerInsight mounted?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eIt can be \u003cstrong\u003ewall-mounted\u003c\/strong\u003e using the supplied bracket, screws and wall anchors, or placed on a \u003cstrong\u003eflat surface\u003c\/strong\u003e using a separate stand (stand not included in the box).\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eWhat happens if the power goes out?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003ePowerInsight includes a \u003cstrong\u003e3000mAh backup battery\u003c\/strong\u003e, allowing it to continue operating for a period during a power interruption.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"EcoFlow","offers":[{"title":"Default Title","offer_id":63001022824797,"sku":"ecoflow-powerinsight","price":395.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/EcoFlowPowerInsightHomeEnergyMonitorside.webp?v=1767180996"},{"product_id":"ecoflow-1ph-meter","title":"EcoFlow 1ph Meter","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eEcoFlow 1ph Meter\u003c\/strong\u003e is a precision single-phase energy meter designed for accurate measurement of grid import\/export and PV generation in Power Ocean hybrid inverter systems, enabling zero-export compliance and dynamic tariff optimisation.\u003c\/p\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThis DIN-rail mounted bi-directional meter provides Class 1.0 accuracy for G99 export limitation and real-time power flow monitoring. With Modbus RTU communication and automatic inverter integration, it supports precise zero-export control, CT clamp verification, and detailed energy analytics for UK residential installations.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional measurement:\u003c\/strong\u003e Accurate import\/export tracking with 1W resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-export compliance:\u003c\/strong\u003e G99 Type A certified for DNO notification-free installations up to 3.68kW.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus integration:\u003c\/strong\u003e RS485 communication with Power Ocean inverters for real-time control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse output:\u003c\/strong\u003e Secondary verification and data logging capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-rail compact:\u003c\/strong\u003e Fits standard consumer unit enclosures (1 module width).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-tamper design:\u003c\/strong\u003e Sealed cover with reverse energy detection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Details\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy class:\u003c\/strong\u003e Class 1.0 (active energy), Class 2.0 (reactive).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage range:\u003c\/strong\u003e 230V ±20% (184–276V).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent range:\u003c\/strong\u003e 5(80)A direct connect (no CT required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50Hz ±5%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e RS485 Modbus RTU (9600bps), 1x pulse output (1000imp\/kWh).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e \u0026lt;2W \/ \u0026lt;10VA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up current:\u003c\/strong\u003e 20mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e MID B+D certified, G99 Type A, IEC 62053-21.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 18 × 89 × 68mm (1 module DIN-rail).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 145g.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e IP51 polycarbonate, transparent sealable cover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminals:\u003c\/strong\u003e 6mm² cage clamp (L, N, CT optional).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN-rail (TS35).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e −20°C to +55°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e LCD 6+1 digit (kWh), 4-digit power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSystem \u0026amp; Application Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Power Ocean 3.6kW\/6kW single-phase inverters; auto-detects via Modbus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Direct connect to main supply L\u0026amp;N post-MCB; professional Sparks install required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e L1 after main switch, before consumer unit (import\/export measurement point).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternatives:\u003c\/strong\u003e Three-phase meter available; CT clamps for higher current systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e G99 export limitation, net metering, tariff optimisation, energy monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 5 years; MID calibration valid 10 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories:\u003c\/strong\u003e DIN rail adapter, Modbus extension cable, sealing wire included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"EcoFlow","offers":[{"title":"Default Title","offer_id":63001080955229,"sku":"EFA-ADL200","price":79.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/EcoFlow1phMeter.png?v=1767182532"},{"product_id":"ecoflow-3ph-meter","title":"EcoFlow 3ph Meter","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eEcoFlow 3ph Meter\u003c\/strong\u003e is a precision three-phase energy meter designed for accurate measurement of grid import\/export and PV generation across all phases in Power Ocean hybrid inverter systems, enabling zero-export compliance and dynamic tariff optimisation for commercial and larger residential installations.\u003c\/p\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThis DIN-rail mounted bi-directional meter provides Class 1.0 accuracy for G99 export limitation on three-phase supplies up to 100A per phase. With Modbus RTU communication and automatic inverter integration, it supports precise phase-balanced zero-export control, CT clamp verification, and detailed energy analytics for UK three-phase systems.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-phase measurement:\u003c\/strong\u003e Independent monitoring of L1\/L2\/L3 import\/export with phase imbalance detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero-export compliance:\u003c\/strong\u003e G99 Type A certified for DNO notification-free installations up to 16A\/phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus integration:\u003c\/strong\u003e RS485 communication with Power Ocean inverters for real-time per-phase control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual pulse outputs:\u003c\/strong\u003e Active\/reactive energy verification and external data logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact DIN-rail:\u003c\/strong\u003e Fits standard consumer unit enclosures (2 module width).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower quality monitoring:\u003c\/strong\u003e THD, PF, voltage imbalance alerts via Modbus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Details\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy class:\u003c\/strong\u003e Class 1.0 (active energy), Class 2.0 (reactive), Class 0.5S (four-quadrant).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage range:\u003c\/strong\u003e 3x230\/400V ±20% (184–276V L-N).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent range:\u003c\/strong\u003e 5(100)A direct connect per phase (no CT required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50Hz ±5%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e RS485 Modbus RTU (9600\/19200bps), 2x pulse outputs (1000imp\/kWh).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e \u0026lt;3W \/ \u0026lt;15VA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart-up current:\u003c\/strong\u003e 15mA per phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e MID B+D certified, G99 Type A, IEC 62053-22.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 36 × 89 × 68mm (2 module DIN-rail).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 285g.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e IP51 polycarbonate, transparent sealable cover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminals:\u003c\/strong\u003e 10mm² cage clamp (3xL, 3xN, neutral current).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN-rail (TS35).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e −20°C to +55°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e LCD 8+1 digit (kWh), per-phase power, PF, THD.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSystem \u0026amp; Application Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Power Ocean three-phase inverters; auto-detects via Modbus register map.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Direct connect to main three-phase supply L1\/L2\/L3\/N post-main breaker; Sparks install required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e All three phases after main switch, before consumer unit\/distribution board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternatives:\u003c\/strong\u003e Single-phase meter for domestic; CT version for \u0026gt;100A systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e Commercial G99 export limitation, three-phase solar farms, EV fleet charging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 5 years; MID calibration valid 10 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories:\u003c\/strong\u003e Modbus extension cable, DIN rail adapter, sealing wire, phase rotation sticker.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"EcoFlow","offers":[{"title":"Default Title","offer_id":63001088819549,"sku":"EFA-ADL400N","price":149.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/EcoFlow3phMeter.png?v=1767182922"},{"product_id":"ecoflow-gateway-backup-box-single-phase","title":"EcoFlow 100A Single-Phase Gateway Backup Box","description":"\u003c!-- SEO Product Name: EcoFlow 100A Single-Phase Gateway Backup Box | EF-SG-001 | 0ms --\u003e\n\u003cdiv style=\"font-size: 16px; max-width: 900px;\"\u003e\n\u003cp style=\"margin: 0 0 14px 0; line-height: 1.6; color: #222222;\"\u003eThe \u003cstrong\u003eEcoFlow Gateway Backup Box (Single-Phase, EF-SG-001)\u003c\/strong\u003e is the central switching hub for \u003cstrong\u003ewhole-home backup\u003c\/strong\u003e with \u003cstrong\u003eEcoFlow PowerOcean single-phase\u003c\/strong\u003e solar and battery systems. It supports \u003cstrong\u003e100 A mains\u003c\/strong\u003e and connects \u003cstrong\u003edirectly to your main distribution panel\u003c\/strong\u003e, so the whole house can stay powered through a grid outage rather than just a handful of critical circuits.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 14px 0; line-height: 1.6; color: #222222;\"\u003eWith \u003cstrong\u003e0 ms load-side backup switchover\u003c\/strong\u003e (when paired with a PowerOcean single-phase system), it keeps lights, appliances and electronics running without a flicker. It also adds a \u003cstrong\u003e100 A generator port with 2-wire auto-start\u003c\/strong\u003e, supports \u003cstrong\u003ethird-party solar inverters\u003c\/strong\u003e, and provides a \u003cstrong\u003enon-backup load port\u003c\/strong\u003e for circuits you do not want drawing from the battery. Rated \u003cstrong\u003eIP54\u003c\/strong\u003e for indoor or outdoor mounting, it is a compact \u003cstrong\u003e15 kg wall-mounted\u003c\/strong\u003e unit.\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 10px; margin: 20px 0;\"\u003e\n\u003cdiv style=\"flex: 1 1 130px; min-width: 130px; background: #008377CF; color: #ffffff; border-radius: 6px; padding: 14px 8px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; line-height: 1.2;\"\u003e100 A\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; margin-top: 4px; line-height: 1.3;\"\u003eMains, backup and generator ports\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; min-width: 130px; background: #008377CF; color: #ffffff; border-radius: 6px; padding: 14px 8px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; line-height: 1.2;\"\u003e0 ms\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; margin-top: 4px; line-height: 1.3;\"\u003eLoad-side switchover*\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; min-width: 130px; background: #008377CF; color: #ffffff; border-radius: 6px; padding: 14px 8px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; line-height: 1.2;\"\u003e22\/23\/24 kW\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; margin-top: 4px; line-height: 1.3;\"\u003eNominal AC power\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; min-width: 130px; background: #008377CF; color: #ffffff; border-radius: 6px; padding: 14px 8px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; line-height: 1.2;\"\u003eIP54\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; margin-top: 4px; line-height: 1.3;\"\u003eIndoor \/ outdoor\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; min-width: 130px; background: #008377CF; color: #ffffff; border-radius: 6px; padding: 14px 8px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; line-height: 1.2;\"\u003e15 kg\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; margin-top: 4px; line-height: 1.3;\"\u003eWall mounted\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; min-width: 130px; background: #008377CF; color: #ffffff; border-radius: 6px; padding: 14px 8px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: bold; line-height: 1.2;\"\u003e2-wire\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; margin-top: 4px; line-height: 1.3;\"\u003eGenerator auto-start\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin: 0 0 14px 0; line-height: 1.6; color: #222222;\"\u003e\u003cspan style=\"font-size: 13px; color: #555555;\"\u003e* Requires an EcoFlow PowerOcean single-phase system whose rated power exceeds the total power drawn by the backup loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"border-left: 6px solid #E08A00; background: #FFF4E0; padding: 14px 18px; margin: 0 0 16px 0; border-radius: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #e08a00; margin-bottom: 6px;\"\u003eNot compatible with the single-phase OCEAN 2 PLUS range\u003c\/div\u003e\n\u003cdiv style=\"line-height: 1.55; color: #222222;\"\u003eThis gateway is \u003cstrong\u003enot compatible with the EcoFlow single-phase OCEAN 2 PLUS\u003c\/strong\u003e range. EcoFlow states that the current gateway (SKU EFA-GATEWAY-P1) does not work with OCEAN 2 PLUS single-phase, which has its own \u003cstrong\u003eintegrated backup\u003c\/strong\u003e and does not need an additional gateway. This gateway is intended for \u003cstrong\u003ePowerOcean single-phase\u003c\/strong\u003e systems.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left: 6px solid #E08A00; background: #FFF4E0; padding: 14px 18px; margin: 0 0 16px 0; border-radius: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #e08a00; margin-bottom: 6px;\"\u003eCheck inverter compatibility before ordering\u003c\/div\u003e\n\u003cdiv style=\"line-height: 1.55; color: #222222;\"\u003eEcoFlow's datasheet lists these compatible inverters: \u003cstrong\u003eEF HD-P1-3K-S1, EF HD-P1-3.68K-S1, EF HD-P1-4.6K-S1, EF HD-P1-5K-S1 and EF HD-P1-6K-S1\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left: 6px solid #C62828; background: #FDECEA; padding: 14px 18px; margin: 0 0 16px 0; border-radius: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #c62828; margin-bottom: 6px;\"\u003eSafety and installation\u003c\/div\u003e\n\u003cdiv style=\"line-height: 1.55; color: #222222;\"\u003eInstallation and commissioning must be carried out by a \u003cstrong\u003equalified electrician\u003c\/strong\u003e in accordance with \u003cstrong\u003eBS 7671\u003c\/strong\u003e and the EcoFlow installation guide, including the \u003cstrong\u003eG98 \/ G99\u003c\/strong\u003e grid connection requirements for the PowerOcean system. The gateway connects to the main distribution panel, so isolate the supply before any work.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left: 6px solid #E08A00; background: #FFF4E0; padding: 14px 18px; margin: 0 0 16px 0; border-radius: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #e08a00; margin-bottom: 6px;\"\u003eSwitchover conditions and temperature derating\u003c\/div\u003e\n\u003cdiv style=\"line-height: 1.55; color: #222222;\"\u003eThe \u003cstrong\u003e0 ms switchover\u003c\/strong\u003e applies when the gateway is used with an \u003cstrong\u003eEcoFlow PowerOcean single-phase\u003c\/strong\u003e system and the system's rated power exceeds the total backup load. Between \u003cstrong\u003e40 and 55 °C\u003c\/strong\u003e, the allowable current is linearly derated from \u003cstrong\u003e100 A to 62.5 A\u003c\/strong\u003e, and above 2,000 m altitude the unit also derates.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size: 20px; color: #008377cf; margin: 26px 0 12px 0; font-weight: bold;\"\u003eKey features\u003c\/h3\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 14px; margin: 0 0 10px 0;\"\u003e\n\u003cdiv style=\"flex: 1 1 250px; min-width: 250px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 6px; padding: 14px 16px; background: #ffffff;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 6px;\"\u003eWhole-home backup\u003c\/div\u003e\n\u003cdiv style=\"line-height: 1.55; color: #222222; font-size: 15px;\"\u003eHandles \u003cstrong\u003e100 A\u003c\/strong\u003e on the grid, backup and generator ports, so most households can back up \u003cstrong\u003ethe whole house\u003c\/strong\u003e without choosing a limited set of critical circuits.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 250px; min-width: 250px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 6px; padding: 14px 16px; background: #ffffff;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 6px;\"\u003e0 ms switchover\u003c\/div\u003e\n\u003cdiv style=\"line-height: 1.55; color: #222222; font-size: 15px;\"\u003e\n\u003cstrong\u003eLoad-side backup switchover of 0 ms\u003c\/strong\u003e when paired with a PowerOcean single-phase system, so there is no flicker or interruption to your loads.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 250px; min-width: 250px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 6px; padding: 14px 16px; background: #ffffff;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 6px;\"\u003eGenerator port\u003c\/div\u003e\n\u003cdiv style=\"line-height: 1.55; color: #222222; font-size: 15px;\"\u003eA dedicated \u003cstrong\u003e100 A generator port\u003c\/strong\u003e with \u003cstrong\u003e2-wire auto-start\u003c\/strong\u003e support lets a diesel generator join grid, solar and battery as a power source.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 250px; min-width: 250px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 6px; padding: 14px 16px; background: #ffffff;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 6px;\"\u003eSolar, EV and more\u003c\/div\u003e\n\u003cdiv style=\"line-height: 1.55; color: #222222; font-size: 15px;\"\u003eWorks with \u003cstrong\u003ethird-party solar inverters\u003c\/strong\u003e and other EcoFlow products including the \u003cstrong\u003ePowerPulse 2 EV charger\u003c\/strong\u003e, with a \u003cstrong\u003enon-backup load port\u003c\/strong\u003e for non-essential circuits.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 250px; min-width: 250px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 6px; padding: 14px 16px; background: #ffffff;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 6px;\"\u003eEasy panel connection\u003c\/div\u003e\n\u003cdiv style=\"line-height: 1.55; color: #222222; font-size: 15px;\"\u003eConnects \u003cstrong\u003edirectly to the main distribution panel\u003c\/strong\u003e with simplified wiring, reducing installation complexity, cost and time.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 250px; min-width: 250px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 6px; padding: 14px 16px; background: #ffffff;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 6px;\"\u003eParallel-ready monitoring\u003c\/div\u003e\n\u003cdiv style=\"line-height: 1.55; color: #222222; font-size: 15px;\"\u003eSupports connecting \u003cstrong\u003emultiple PowerOcean single-phase systems\u003c\/strong\u003e for greater total output, and gives \u003cstrong\u003ewhole-house load access\u003c\/strong\u003e for real-time usage and generation monitoring.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size: 20px; color: #008377cf; margin: 26px 0 12px 0; font-weight: bold;\"\u003eTechnical specification\u003c\/h3\u003e\n\u003cdiv style=\"margin: 0 0 18px 0; border: 1px solid #008377CF; border-radius: 6px; overflow: hidden;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 16px;\"\u003eGeneral\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eModel\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003eEF-SG-001\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #ffffff; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eCompatible inverters\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003eEF HD-P1-3K-S1, EF HD-P1-3.68K-S1, EF HD-P1-4.6K-S1, EF HD-P1-5K-S1, EF HD-P1-6K-S1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eDimensions (W x H x D)\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e465 x 380 x 160 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #ffffff; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eWeight\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e15 kg\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eInstallation\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003eWall mount\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #ffffff; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eNoise emission\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e\u0026lt; 30 dB\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eCommunication\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003eEthernet, RS485, CAN, DI, DO\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #ffffff; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eDC power output\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e12 V \/ 1 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eLow voltage ride through\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003eSupported\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #ffffff; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eBypass operation mode\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003eManual\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 18px 0; border: 1px solid #008377CF; border-radius: 6px; overflow: hidden;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 16px;\"\u003eGrid connection and backup port\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eGrid connection type\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003eL\/N + PE\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #ffffff; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eNominal AC voltage\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e220 \/ 230 \/ 240 V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eNominal AC current\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e100 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #ffffff; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eNominal AC power\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e22 \/ 23 \/ 24 kW\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eNominal AC frequency\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e50 \/ 60 Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #ffffff; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eBackup switchover time\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e0 ms (with PowerOcean single-phase system)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eBackup port output\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e220 \/ 230 \/ 240 V, 100 A, 22 \/ 23 \/ 24 kW\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #ffffff; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eOvervoltage category\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 18px 0; border: 1px solid #008377CF; border-radius: 6px; overflow: hidden;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 16px;\"\u003eGenerator and load ports\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eGenerator port\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e220 \/ 230 \/ 240 V, 100 A, 22 \/ 23 \/ 24 kW\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #ffffff; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eGenerator 2-wire auto-start\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003eSupported\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eNon-backup load port\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e100 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #ffffff; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eThird-party solar inverters\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003eSupported\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 18px 0; border: 1px solid #008377CF; border-radius: 6px; overflow: hidden;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 16px;\"\u003eEnvironment\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eCooling\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003eNatural convection, with internal fan\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #ffffff; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eIngress protection rating\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003eIP54\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eEnvironmental category\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003eIndoor \/ outdoor\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #ffffff; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eOperating temperature\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e-30 to 55 °C (100 A up to 40 °C; derated linearly to 62.5 A at 55 °C)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eStorage temperature\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e-30 to 60 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #ffffff; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eRelative humidity\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e0% to 95% RH\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; background: #EAF4F2; padding: 9px 16px; border-top: 1px solid #d5e6e3;\"\u003e\n\u003cdiv style=\"flex: 1 1 240px; font-weight: 600; color: #222222;\"\u003eMaximum operating altitude\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 300px; color: #222222;\"\u003e3,000 m (derating above 2,000 m)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin: 0 0 14px 0; line-height: 1.6; color: #222222;\"\u003e\u003cspan style=\"font-size: 13px; color: #555555;\"\u003eSpecifications are subject to change by the manufacturer without notice.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 style=\"font-size: 20px; color: #008377cf; margin: 26px 0 12px 0; font-weight: bold;\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cdetails style=\"margin: 0 0 10px 0; border: 1px solid #008377CF; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 16px; cursor: pointer;\"\u003eIs the gateway compatible with the single-phase OCEAN 2 PLUS?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; line-height: 1.6; color: #222222; background: #ffffff;\"\u003eNo. The \u003cstrong\u003eEcoFlow Gateway (EF-SG-001) is not compatible with the single-phase OCEAN 2 PLUS range\u003c\/strong\u003e. OCEAN 2 PLUS has integrated backup and does not need this gateway. The gateway is designed for \u003cstrong\u003ePowerOcean single-phase\u003c\/strong\u003e systems.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin: 0 0 10px 0; border: 1px solid #008377CF; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 16px; cursor: pointer;\"\u003eWhich inverters does it work with?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; line-height: 1.6; color: #222222; background: #ffffff;\"\u003eEcoFlow's datasheet lists the \u003cstrong\u003eEF HD-P1-3K-S1, 3.68K, 4.6K, 5K and 6K\u003c\/strong\u003e single-phase inverters. Some UK trade listings also mention the standard OCEAN 2 single-phase range, so confirm your exact model with EcoFlow or your installer before ordering.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin: 0 0 10px 0; border: 1px solid #008377CF; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 16px; cursor: pointer;\"\u003eDoes it back up the whole house?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; line-height: 1.6; color: #222222; background: #ffffff;\"\u003eIt is built for \u003cstrong\u003ewhole-home backup\u003c\/strong\u003e with \u003cstrong\u003e100 A\u003c\/strong\u003e on the grid, backup and generator ports. How much of the house stays powered depends on the connected PowerOcean system, whose \u003cstrong\u003erated power must exceed the total backup load\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin: 0 0 10px 0; border: 1px solid #008377CF; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 16px; cursor: pointer;\"\u003eWhat does 0 ms switchover mean?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; line-height: 1.6; color: #222222; background: #ffffff;\"\u003eIt is the \u003cstrong\u003eload-side transfer interruption time\u003c\/strong\u003e when the grid fails. The \u003cstrong\u003e0 ms\u003c\/strong\u003e figure applies when the gateway is used with a PowerOcean single-phase system whose rated power exceeds the backup loads.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin: 0 0 10px 0; border: 1px solid #008377CF; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 16px; cursor: pointer;\"\u003eCan I connect a generator or other solar?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; line-height: 1.6; color: #222222; background: #ffffff;\"\u003eYes. The gateway has a \u003cstrong\u003e100 A generator port with 2-wire auto-start\u003c\/strong\u003e and supports \u003cstrong\u003ethird-party solar inverters\u003c\/strong\u003e, so grid, solar, battery and generator can all feed the home.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin: 0 0 10px 0; border: 1px solid #008377CF; border-radius: 6px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 16px; cursor: pointer;\"\u003eCan it be installed outdoors?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; line-height: 1.6; color: #222222; background: #ffffff;\"\u003eYes. It is \u003cstrong\u003eIP54\u003c\/strong\u003e, suitable for \u003cstrong\u003eindoor or outdoor\u003c\/strong\u003e wall mounting, with an operating range of \u003cstrong\u003e-30 to 55 °C\u003c\/strong\u003e. Above 40 °C the current is derated from 100 A to 62.5 A at 55 °C.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e","brand":"EcoFlow","offers":[{"title":"Default Title","offer_id":63001784484189,"sku":"EF-SG-001","price":730.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/EcoFlowGatewayBackupSingle-phase.webp?v=1767190084"},{"product_id":"sma-energy-meter-e-meter-20","title":"SMA Energy Meter E-METER-20","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eSMA Energy Meter E-METER-20\u003c\/strong\u003e is a high-performance three-phase bidirectional energy meter for intelligent energy management in PV systems, providing precise phase-exact measurements via Ethernet connectivity.\u003c\/p\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThis compact meter measures grid feed-in, purchased electricity, and PV generation with 1% accuracy, communicating data via Ethernet to SMA devices like Sunny Home Manager or Data Manager M. It enables dynamic power limitation, self-consumption optimisation, and comprehensive energy monitoring through Sunny Portal.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-phase measurement:\u003c\/strong\u003e Phase-exact readings for balanced load management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast data transmission:\u003c\/strong\u003e 1000 ms measurement cycle via Ethernet\/Speedwire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal compatibility:\u003c\/strong\u003e Works with existing energy meters and SMA Smart Home systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-and-play installation:\u003c\/strong\u003e Top-hat rail mounting in distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic power control:\u003c\/strong\u003e Enables zero-export and self-consumption optimisation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisualisation:\u003c\/strong\u003e Real-time data in Sunny Portal and local web interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Details\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Ethernet (10\/100 Mbit\/s, RJ45).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 230\/400 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz (±5%).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal current:\u003c\/strong\u003e 5 A (63 A limiting per conductor).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e Class 1.0 (1% measurement error).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-consumption:\u003c\/strong\u003e \u0026lt; 2–3 W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent transformers:\u003c\/strong\u003e Required for 63 A operation (included or optional).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 70 × 88 × 65 mm (4 TE top-hat rail).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.3 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection rating:\u003c\/strong\u003e IP20 (indoor switch cabinet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e −25°C to +40°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Top-hat rail (EN 60715).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus display:\u003c\/strong\u003e 2 LEDs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSystem \u0026amp; Application Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e PV self-consumption, zero-export, energy management with SMA inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Sunny Home Manager 2.0+, Data Manager M, Sunny Boy Smart Energy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Distribution board with CTs on grid supply side; Ethernet to router\/SMA device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-phase use:\u003c\/strong\u003e Configurable for single-phase operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2 years.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"SMA Sunny Boy","offers":[{"title":"Default Title","offer_id":63114637967709,"sku":"E-METER-20","price":370.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SMAEnergyMeter.webp?v=1768493832"},{"product_id":"current-transformer-100a-incl-fly-lead","title":"Current Transformer 100A with fly lead","description":"\u003cdiv\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eCurrent Transformer 100A (incl. fly lead)\u003c\/strong\u003e is a split-core AC current sensor designed for precise monitoring in solar PV systems, compatible with Solis inverters and export power managers for accurate current measurement and grid compliance.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThis 100A split-core current transformer (CT) allows non-invasive installation without disconnecting cables, making it ideal for retrofits and monitoring applications. It features a fly lead for easy connection to compatible devices like Solis EPM or inverters. With high accuracy and robust construction, it supports export limitation, energy metering, and system optimization in residential and small commercial setups.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eKey Features\u003c\/h2\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit-core design:\u003c\/strong\u003e Easy clip-on installation without wiring disruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFly lead included:\u003c\/strong\u003e Pre-wired cable for quick and secure connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh accuracy:\u003c\/strong\u003e ±1% typical, suitable for metering and control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with Solis:\u003c\/strong\u003e Works with Solis inverters for export power management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust and reliable:\u003c\/strong\u003e Frequency 50-60Hz, durable for long-term use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e STCK35-100A – Current Transformer 100A with Fly Lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 100A primary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecondary output:\u003c\/strong\u003e Typically 33.33mA or 5A (Solis compatible).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy class:\u003c\/strong\u003e ±1% (20%-120% rated current).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50-60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e Approx. 24mm or 35mm (model dependent).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eDimensions \u0026amp; Weights\u003c\/h2\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner hole diameter:\u003c\/strong\u003e ~24-35 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFly lead length:\u003c\/strong\u003e Standard 1-10m (varies by supplier).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~0.26 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eSystem \u0026amp; Application Notes\u003c\/h2\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003eIdeal for Solis single-phase inverters and EPM devices for export limitation.\u003c\/li\u003e\n\u003cli\u003eClip around live conductor for non-intrusive current sensing.\u003c\/li\u003e\n\u003cli\u003eCompatible with energy monitoring systems and grid compliance setups.\u003c\/li\u003e\n\u003cli\u003eInstallation by qualified electricians; ensure correct polarity and secure mounting.\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor\/outdoor use depending on enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Landis+Gyr","offers":[{"title":"Default Title","offer_id":63258763755869,"sku":"CT-100A","price":35.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/LandisGyrCurrentTransformerCTClamp.webp?v=1769961981"},{"product_id":"current-transformer-200a-with-fly-lead","title":"Current Transformer 200A with fly lead","description":"\u003cdiv\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eCurrent Transformer 200A (incl. fly lead)\u003c\/strong\u003e is a split-core AC current sensor designed for precise monitoring in solar PV systems, compatible with Solis inverters and export power managers for accurate current measurement and grid compliance.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThis 200A split-core current transformer (CT) allows non-invasive installation without disconnecting cables, making it ideal for retrofits and monitoring applications. It features a fly lead for easy connection to compatible devices like Solis EPM or inverters. With high accuracy and robust construction, it supports export limitation, energy metering, and system optimization in residential and small commercial setups.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eKey Features\u003c\/h2\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit-core design:\u003c\/strong\u003e Easy clip-on installation without wiring disruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFly lead included:\u003c\/strong\u003e Pre-wired cable for quick and secure connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh accuracy:\u003c\/strong\u003e ±1% typical, suitable for metering and control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with Solis:\u003c\/strong\u003e Works with Solis inverters for export power management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust and reliable:\u003c\/strong\u003e Frequency 50-60Hz, durable for long-term use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e SCT24-200A – Current Transformer 200A with Fly Lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 200A primary \/ 5A secondary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy class:\u003c\/strong\u003e ±1% (20%-120% rated current).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50-60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 24 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eDimensions \u0026amp; Weights\u003c\/h2\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner hole diameter:\u003c\/strong\u003e 24 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFly lead length:\u003c\/strong\u003e Standard (varies by supplier).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~0.3 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eSystem \u0026amp; Application Notes\u003c\/h2\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003eIdeal for Solis single-phase inverters and EPM devices for export limitation.\u003c\/li\u003e\n\u003cli\u003eClip around live conductor for non-intrusive current sensing.\u003c\/li\u003e\n\u003cli\u003eCompatible with energy monitoring systems and grid compliance setups.\u003c\/li\u003e\n\u003cli\u003eInstallation by qualified electricians; ensure correct polarity and secure mounting.\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor\/outdoor use depending on enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Landis+Gyr","offers":[{"title":"Default Title","offer_id":63258800456029,"sku":"CT-200A","price":35.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/LandisGyrCurrentTransformerCTClamp.webp?v=1769961981"},{"product_id":"current-transformer-500a-with-fly-lead","title":"Current Transformer 500A with fly lead","description":"\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eCurrent Transformer 500A (incl. fly lead) \u003c\/strong\u003eis a split-core AC current sensor designed for precise monitoring in solar PV systems, compatible with Solis inverters and export power managers for accurate current measurement and grid compliance.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThis 500A split-core current transformer (CT) allows non-invasive installation without disconnecting cables, making it ideal for retrofits and monitoring applications. It features a fly lead for easy connection to compatible devices like Solis EPM or inverters. With high accuracy and robust construction, it supports export limitation, energy metering, and system optimization in larger residential and commercial setups.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eKey Features\u003c\/h2\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit-core design:\u003c\/strong\u003e Easy clip-on installation without wiring disruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFly lead included:\u003c\/strong\u003e Pre-wired cable for quick and secure connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh accuracy:\u003c\/strong\u003e ±1% typical, suitable for metering and control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with Solis:\u003c\/strong\u003e Works with Solis inverters for export power management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust and reliable:\u003c\/strong\u003e Frequency 50-60Hz, durable for long-term use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e STCK35-500A – Current Transformer 500A with Fly Lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 500A primary \/ 5A secondary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy class:\u003c\/strong\u003e ±1% (20%-120% rated current).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50-60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 36 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eDimensions \u0026amp; Weights\u003c\/h2\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner hole diameter:\u003c\/strong\u003e 36 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFly lead length:\u003c\/strong\u003e Standard (varies by supplier).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~0.4 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eSystem \u0026amp; Application Notes\u003c\/h2\u003e\n\u003cul dir=\"auto\"\u003e\n\u003cli\u003eIdeal for Solis three-phase inverters and EPM devices for export limitation.\u003c\/li\u003e\n\u003cli\u003eClip around live conductor for non-intrusive current sensing.\u003c\/li\u003e\n\u003cli\u003eCompatible with energy monitoring systems and grid compliance setups.\u003c\/li\u003e\n\u003cli\u003eInstallation by qualified electricians; ensure correct polarity and secure mounting.\u003c\/li\u003e\n\u003cli\u003eSuitable for indoor\/outdoor use depending on enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Landis+Gyr","offers":[{"title":"Default Title","offer_id":63258808451421,"sku":"CT-500A","price":35.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/LandisGyrCurrentTransformerCTClamp.webp?v=1769961981"},{"product_id":"current-transformer-for-solis-4g-5g-and-s6-range-100a-10m","title":"Solis 100A CT Clamp 10m for 4G, 5G and S6 Inverters | CTSA016","description":"\u003c!-- SEO Product Name: Solis 100A CT Clamp 10m for 4G, 5G and S6 Inverters | CTSA016 --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; font-family:Arial, Helvetica, sans-serif; color:#222222;\"\u003e\n\u003cp style=\"margin:0 0 14px 0; color:#222222; line-height:1.65;\"\u003eThe \u003cstrong\u003eSolis 100A split-core current transformer (CTSA016-100A)\u003c\/strong\u003e is the clip-on \u003cstrong\u003eCT clamp\u003c\/strong\u003e that lets a compatible \u003cstrong\u003esingle-phase Solis inverter\u003c\/strong\u003e see how much power is flowing at the property's grid connection. With that reading, the inverter can apply \u003cstrong\u003eexport power limitation\u003c\/strong\u003e by throttling its output as household demand drops, and on supported models it can also feed \u003cstrong\u003econsumption monitoring\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0; color:#222222; line-height:1.65;\"\u003eIt is a \u003cstrong\u003e100 A : 33.33 mA (3000:1)\u003c\/strong\u003e current-output sensor with a \u003cstrong\u003e16 mm split-core opening\u003c\/strong\u003e and a \u003cstrong\u003efactory-fitted 10 m secondary lead\u003c\/strong\u003e, so it clamps straight around a live conductor without disconnecting anything and can be sited well away from the inverter. Ratio error is \u003cstrong\u003e±0.5%\u003c\/strong\u003e with linearity held across \u003cstrong\u003e5 A to 120 A\u003c\/strong\u003e, giving the inverter an accurate signal to work from.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0; color:#222222; line-height:1.65;\"\u003eThis is the CT supplied for the \u003cstrong\u003eSolis mini 4G, 1P 4G, 5G and S6 grid-tied ranges\u003c\/strong\u003e. It is a \u003cstrong\u003esingle-phase\u003c\/strong\u003e solution designed for \u003cstrong\u003eone CT per inverter\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:10px; margin:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 8px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:24px; font-weight:bold; line-height:1.2;\"\u003e100 A\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eRated primary current\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 8px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:24px; font-weight:bold; line-height:1.2;\"\u003e33.33 mA\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eSecondary output\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 8px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:24px; font-weight:bold; line-height:1.2;\"\u003e3000:1\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eTurns ratio\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 8px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:24px; font-weight:bold; line-height:1.2;\"\u003e±0.5%\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eRated ratio error\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 8px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:24px; font-weight:bold; line-height:1.2;\"\u003e16 mm\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eSplit-core opening\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 8px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:24px; font-weight:bold; line-height:1.2;\"\u003e10 m\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eSecondary lead\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:6px solid #c62828; background:#fdecea; border-radius:6px; padding:14px 18px; margin:16px 0;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#c62828; margin-bottom:6px;\"\u003eSafety and regulatory requirements\u003c\/div\u003e\n\u003cdiv style=\"color:#222222; line-height:1.6;\"\u003eThe CT clamps around a \u003cstrong\u003elive mains conductor\u003c\/strong\u003e, so fitting must be carried out by a \u003cstrong\u003equalified electrician\u003c\/strong\u003e with the supply isolated and appropriate protective equipment in use, in line with \u003cstrong\u003eBS 7671\u003c\/strong\u003e. Do not leave the secondary lead unterminated while the clamped conductor is carrying load. Systems that limit export to the grid must be designed, commissioned and notified to the DNO in line with \u003cstrong\u003eG98 \/ G99\u003c\/strong\u003e and \u003cstrong\u003eG100\u003c\/strong\u003e as applicable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:6px solid #ef6c00; background:#fff4e5; border-radius:6px; padding:14px 18px; margin:16px 0;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#b35200; margin-bottom:6px;\"\u003eCheck compatibility before ordering\u003c\/div\u003e\n\u003cdiv style=\"color:#222222; line-height:1.6;\"\u003eThis CT is for \u003cstrong\u003esingle-phase Solis inverters with a CT port\u003c\/strong\u003e and works on a \u003cstrong\u003eone-CT-to-one-inverter\u003c\/strong\u003e basis. It is \u003cstrong\u003enot intended for Solis EPM (Export Power Manager) systems\u003c\/strong\u003e, multi-inverter installations or three-phase inverters, which use different meters or sensors. Some inverter versions have a \u003cstrong\u003emeter port instead of a CT port\u003c\/strong\u003e, and hybrid models can specify a different sensor, so confirm your exact model and hardware version against the Solis compatibility guide.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:6px solid #008377CF; background:#e6f4f2; border-radius:6px; padding:14px 18px; margin:16px 0;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003ePlacement and direction\u003c\/div\u003e\n\u003cdiv style=\"color:#222222; line-height:1.6;\"\u003eClamp the CT around the \u003cstrong\u003elive (line) conductor\u003c\/strong\u003e at the grid connection point, with the \u003cstrong\u003earrow on the housing pointing towards the grid\u003c\/strong\u003e, and secure it with a cable tie so it cannot slip. The current in the clamped conductor must not exceed the CT's \u003cstrong\u003e100 A rating\u003c\/strong\u003e (maximum 120 A). Check that the insulated diameter of the conductor is within the \u003cstrong\u003e16 mm\u003c\/strong\u003e opening.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size:20px; color:#008377CF; border-bottom:3px solid #008377CF; padding-bottom:6px; margin:34px 0 14px 0;\"\u003eKey Features\u003c\/h3\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:16px; margin:18px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:8px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; font-size:16px; color:#008377CF; margin-bottom:8px;\"\u003eSplit-Core Clip-On Fitting\u003c\/div\u003e\n\u003cdiv style=\"color:#222222; line-height:1.6; font-size:15px;\"\u003eThe housing opens and snaps shut around the cable, so there is \u003cstrong\u003eno need to disconnect or cut the conductor\u003c\/strong\u003e. A cable tie holds it in position once the arrow is set towards the grid.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:8px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; font-size:16px; color:#008377CF; margin-bottom:8px;\"\u003e100 A : 33.33 mA Output\u003c\/div\u003e\n\u003cdiv style=\"color:#222222; line-height:1.6; font-size:15px;\"\u003eA \u003cstrong\u003e3000:1\u003c\/strong\u003e ratio delivering a \u003cstrong\u003e33.33 mA\u003c\/strong\u003e secondary signal, matched to the CT input on compatible Solis inverters. It is a mA-output sensor, not a 5 A secondary type.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:8px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; font-size:16px; color:#008377CF; margin-bottom:8px;\"\u003eAccurate Measurement\u003c\/div\u003e\n\u003cdiv style=\"color:#222222; line-height:1.6; font-size:15px;\"\u003e\n\u003cstrong\u003e±0.5% rated ratio error\u003c\/strong\u003e, phase error of 60 minutes or less and \u003cstrong\u003e0.5 linearity from 5 A to 120 A\u003c\/strong\u003e give the inverter a reliable reading across the full range of household loads.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:8px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; font-size:16px; color:#008377CF; margin-bottom:8px;\"\u003e10 m Secondary Lead\u003c\/div\u003e\n\u003cdiv style=\"color:#222222; line-height:1.6; font-size:15px;\"\u003eA \u003cstrong\u003e10 m secondary cable\u003c\/strong\u003e (HFZS-RVV2) is fitted at the factory, giving flexibility to mount the CT at the consumer unit or meter position and run the signal cable back to the inverter.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:8px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; font-size:16px; color:#008377CF; margin-bottom:8px;\"\u003eExport Limitation and Monitoring\u003c\/div\u003e\n\u003cdiv style=\"color:#222222; line-height:1.6; font-size:15px;\"\u003eLets compatible inverters apply \u003cstrong\u003ezero or limited export\u003c\/strong\u003e by tracking grid-point current, and supports \u003cstrong\u003econsumption monitoring\u003c\/strong\u003e on supported models and firmware.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:8px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; font-size:16px; color:#008377CF; margin-bottom:8px;\"\u003eBuilt for Safe Use\u003c\/div\u003e\n\u003cdiv style=\"color:#222222; line-height:1.6; font-size:15px;\"\u003eWhite \u003cstrong\u003eUL 94 V-0 flame-retardant housing\u003c\/strong\u003e, \u003cstrong\u003e4000 V \/ 10 s withstand voltage\u003c\/strong\u003e, \u003cstrong\u003e100 MΩ insulation resistance\u003c\/strong\u003e and a \u003cstrong\u003e6-8 V open-circuit protective voltage\u003c\/strong\u003e. RoHS compliant.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size:20px; color:#008377CF; border-bottom:3px solid #008377CF; padding-bottom:6px; margin:34px 0 14px 0;\"\u003eCompatible Solis Inverters\u003c\/h3\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:16px; margin:18px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:8px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; font-size:16px; color:#008377CF; margin-bottom:8px;\"\u003e4G Range\u003c\/div\u003e\n\u003cdiv style=\"color:#222222; line-height:1.6; font-size:15px;\"\u003e\n\u003cstrong\u003eSolis-mini-(0.7-3.6)K-4G\u003c\/strong\u003e and the \u003cstrong\u003eSolis-1P 4G\u003c\/strong\u003e single-phase series, which have export power limitation built in when a CT is connected.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:8px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; font-size:16px; color:#008377CF; margin-bottom:8px;\"\u003e5G Range\u003c\/div\u003e\n\u003cdiv style=\"color:#222222; line-height:1.6; font-size:15px;\"\u003e\n\u003cstrong\u003eSolis-1P(7-8)K-5G\u003c\/strong\u003e (UK version) single-phase grid-tied inverter.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:5px solid #008377CF; border-radius:8px; padding:16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; font-size:16px; color:#008377CF; margin-bottom:8px;\"\u003eS6 \/ S5 Range\u003c\/div\u003e\n\u003cdiv style=\"color:#222222; line-height:1.6; font-size:15px;\"\u003e\n\u003cstrong\u003eS6 and S5-GR1P(0.7-3.6)K-M\u003c\/strong\u003e and \u003cstrong\u003eS6 and S5-GR1P(2.5-6)K\u003c\/strong\u003e (UK versions) single-phase grid-tied inverters.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:6px solid #ef6c00; background:#fff4e5; border-radius:6px; padding:14px 18px; margin:16px 0;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#b35200; margin-bottom:6px;\"\u003eModels not listed\u003c\/div\u003e\n\u003cdiv style=\"color:#222222; line-height:1.6;\"\u003eSolis publishes its own CT and meter compatibility guide covering hybrid and other variants. If your inverter is not named above, check the guide or contact us before ordering.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size:20px; color:#008377CF; border-bottom:3px solid #008377CF; padding-bottom:6px; margin:34px 0 14px 0;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:8px; overflow:hidden; margin:0 0 18px 0;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:10px 14px;\"\u003eElectrical Characteristics\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003ePrimary rated current\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e100 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#f2f9f8; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eSecondary rated current\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e33.33 mA (ratio 3000:1)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eMaximum current\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e120 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#f2f9f8; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eRated ratio error\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e±0.5%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eRated phase error\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e60 minutes or less\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#f2f9f8; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eLinearity\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e0.5 (5 A to 120 A)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eSecondary load\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e10 Ω\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#f2f9f8; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eOperating frequency\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e50 Hz to 400 Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eOpen-circuit protective voltage\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e6 V to 8 V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:8px; overflow:hidden; margin:0 0 18px 0;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:10px 14px;\"\u003eInsulation and Environment\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003ePower-frequency withstand voltage\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e4000 V for 10 s, 1 mA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#f2f9f8; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eInsulation resistance\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e100 MΩ at 500 V DC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eAmbient operating temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e-10°C to +50°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#f2f9f8; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eStorage temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e-20°C to +70°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eRelative humidity\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e95% or less\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#f2f9f8; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eAtmospheric pressure\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e70 kPa to 106 kPa\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eHousing\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003eWhite, UL 94 V-0 flame rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#f2f9f8; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eCompliance\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003eRoHS\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:8px; overflow:hidden; margin:0 0 18px 0;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:10px 14px;\"\u003ePhysical and Connection\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eType\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003eSplit-core (clip-on) current transformer\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#f2f9f8; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eOpening diameter\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e16 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eOutline (L × W × H)\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003e37.8 × 33.9 × 49 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#f2f9f8; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eSecondary output cable\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003eHFZS-RVV2, 10 m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eOutput terminals\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003eS1 (red) \/ S2 (black)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#f2f9f8; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003ePhase\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003eSingle-phase systems\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eSupported use\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003eOne CT per inverter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:8px; overflow:hidden; margin:0 0 18px 0;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:10px 14px;\"\u003eIdentification\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eBrand\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003eSolis\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#f2f9f8; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eProduct\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003eCurrent transformer, 100A, 10 m lead\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#ffffff; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003eManufacturer model\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003eCTSA016-100A \/ 33.33 mA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:4px 12px; padding:9px 14px; background:#f2f9f8; font-size:15px;\"\u003e\n\u003cdiv style=\"flex:2 1 200px; font-weight:bold; color:#222222;\"\u003ePart number\u003c\/div\u003e\n\u003cdiv style=\"flex:3 1 240px; color:#222222;\"\u003eSOL-CT-100A-10M\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size:20px; color:#008377CF; border-bottom:3px solid #008377CF; padding-bottom:6px; margin:34px 0 14px 0;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:8px; margin:0 0 10px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:12px 16px; cursor:pointer;\"\u003eWhich Solis inverters does this CT work with?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px; color:#222222; line-height:1.65; background:#ffffff;\"\u003eIt is for \u003cstrong\u003esingle-phase grid-tied Solis inverters with a CT port\u003c\/strong\u003e: the mini 4G and 1P 4G series, the Solis-1P(7-8)K-5G and the S6 \/ S5-GR1P(0.7-3.6)K-M and S6 \/ S5-GR1P(2.5-6)K (UK versions). Some hardware versions have a meter port instead of a CT port, so check your inverter's port type. Hybrid inverters and other variants are covered in Solis's own compatibility guide.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF; border-radius:8px; margin:0 0 10px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:12px 16px; cursor:pointer;\"\u003eCan I use it with a three-phase inverter or a Solis EPM?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px; color:#222222; line-height:1.65; background:#ffffff;\"\u003eNo. This is a \u003cstrong\u003esingle-phase, one-CT-per-inverter\u003c\/strong\u003e solution. Three-phase inverters and multi-inverter installations use Solis EPM devices or meters with their own sensors, and this CT is not intended for those systems.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF; border-radius:8px; margin:0 0 10px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:12px 16px; cursor:pointer;\"\u003eWhere do I clamp it and which way round does it go?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px; color:#222222; line-height:1.65; background:#ffffff;\"\u003eClamp it around the \u003cstrong\u003elive conductor at the grid connection point\u003c\/strong\u003e with the \u003cstrong\u003earrow pointing towards the grid\u003c\/strong\u003e. Close the housing fully, fix it with a cable tie, then connect the secondary lead to the inverter's CT terminals (S1 red, S2 black). The supply must be isolated during fitting and the work done by a qualified electrician.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF; border-radius:8px; margin:0 0 10px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:12px 16px; cursor:pointer;\"\u003eHow do I set up export limitation on the inverter?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px; color:#222222; line-height:1.65; background:#ffffff;\"\u003eOnce the CT is fitted and connected, enable the \u003cstrong\u003eexport power management \/ backflow limit\u003c\/strong\u003e function in the inverter settings and enter the export value your connection agreement allows. The exact menu path depends on the inverter and firmware, so follow the Solis export power limitation guide for your model.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF; border-radius:8px; margin:0 0 10px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:12px 16px; cursor:pointer;\"\u003eCan I extend the 10 m lead?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px; color:#222222; line-height:1.65; background:#ffffff;\"\u003eThe CT is supplied with a \u003cstrong\u003e10 m secondary lead\u003c\/strong\u003e as standard. If you need a longer run, contact Solis technical support or us first, because extra length can affect the measurement signal. Keep the signal cable separate from mains cabling wherever possible.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF; border-radius:8px; margin:0 0 10px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:12px 16px; cursor:pointer;\"\u003eWhy is the output 33.33 mA rather than 5 A?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px; color:#222222; line-height:1.65; background:#ffffff;\"\u003eThe CT delivers a \u003cstrong\u003elow-level 33.33 mA signal at 100 A\u003c\/strong\u003e (3000:1), which is what the CT input on compatible Solis inverters expects. It is not a 5 A secondary CT, so it must not be connected to equipment designed for 5 A inputs, and a 5 A CT must not be used in its place on a Solis inverter.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"Solis","offers":[{"title":"Default Title","offer_id":63258855080285,"sku":"SOL-CT-100A-10M","price":24.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SOL-CT-100A-10M.jpg?v=1769963368"},{"product_id":"solis-3phase-meter-dtsd1352-with-3-150a-5a-cts","title":"Solis 3phase Meter DTSD1352 with 3 150A 5A CTs","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eSolis 3phase Meter DTSD1352 with 3x150A:5A CTs\u003c\/strong\u003e is a three-phase energy meter designed for accurate monitoring and export limitation in Solis solar PV systems, including three 150A:5A current transformers for precise electrical parameter measurement.\u003c\/p\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe DTSD1352 is a high-precision three-phase meter that enables full 24-hour net power and consumption monitoring, supporting export power management and grid compliance in Solis inverter setups. It measures various electrical parameters, including temperature, and supports remote communication and control. Supplied with three 150A:5A CTs, it is ideal for single-inverter deployments but can be used in multi-inverter systems with appropriate configuration. For larger inverters like 110kW, higher-rated CTs (e.g., 200A:5A) are recommended.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature measurement:\u003c\/strong\u003e Integrated sensor for environmental monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote communication and control:\u003c\/strong\u003e Enables smart grid integration and remote management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-parameter measurement:\u003c\/strong\u003e Tracks voltage, current, power, energy, and more.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport limitation:\u003c\/strong\u003e Supports zero-export or controlled export configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit-core CTs:\u003c\/strong\u003e Easy installation without disconnecting cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh accuracy:\u003c\/strong\u003e Ensures reliable data for system optimization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN rail mount:\u003c\/strong\u003e Compact and easy to install in electrical panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e DTSD1352 – Three-Phase Energy Meter with CTs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three-phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage rating:\u003c\/strong\u003e 3x230\/400V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent rating (CTs):\u003c\/strong\u003e 150A:5A (three included).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy class:\u003c\/strong\u003e Class 1 (active energy), Class 2 (reactive energy).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e RS485 Modbus for integration with Solis inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -25°C to +55°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection rating:\u003c\/strong\u003e IP20 (meter), suitable for indoor use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDimensions \u0026amp; Weights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeter width:\u003c\/strong\u003e 72 mm (4 DIN modules).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeter depth:\u003c\/strong\u003e 65 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeter height:\u003c\/strong\u003e 90 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT inner diameter:\u003c\/strong\u003e ~24-35 mm (typical for 150A CTs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (meter):\u003c\/strong\u003e ~0.4 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (per CT):\u003c\/strong\u003e ~0.2 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSystem \u0026amp; Application Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for Solis 3-phase inverters (e.g., 4G 5-20kW, S5 5-60kW) for export limitation and monitoring.\u003c\/li\u003e\n\u003cli\u003eCompatible with Solis EPM for advanced power management.\u003c\/li\u003e\n\u003cli\u003eSuitable for residential and commercial PV systems requiring grid compliance.\u003c\/li\u003e\n\u003cli\u003eInstallation by qualified electricians; CTs clip around phase conductors.\u003c\/li\u003e\n\u003cli\u003eUse in conjunction with Solis inverters for zero-export or limited-export setups.\u003c\/li\u003e\n\u003cli\u003eWarranty: 2 years standard (confirm with supplier).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Solis","offers":[{"title":"Default Title","offer_id":63258908000605,"sku":"METER-3PH-CT3","price":130.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Solis3phaseMeterDTSD1352with3x150A5ACTs.jpg?v=1769963960"},{"product_id":"eastron-meter-3ph-v2-for-solis-with-3-x-300a-cts","title":"Eastron Meter 3PH V2 for Solis with 3 x 300A CTs","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eEastron Meter 3PH V2 for Solis with 3 x 300A CTs\u003c\/strong\u003e is a MID-certified three-phase multi-function energy meter designed for accurate monitoring and export limitation in Solis solar PV systems, including three 300A\/5A current transformers for precise electrical parameter measurement.\u003c\/p\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe Eastron SDM630MCT V2 is a high-precision three-phase DIN rail meter that enables full monitoring of power generation, consumption, and export in Solis inverter setups. It measures a wide range of parameters including kWh, kVarh, voltage, current, power, and frequency, supporting Modbus RTU communication for seamless integration. Supplied with three 300A\/5A split-core CTs, it is ideal for export power management and grid compliance in residential and commercial installations.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMID certified:\u003c\/strong\u003e Compliant for billing and accurate energy metering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-parameter measurement:\u003c\/strong\u003e Tracks kWh, kVarh, W, Var, VA, PF, Hz, THD, demand, etc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit-core CTs:\u003c\/strong\u003e Easy non-invasive installation with 3 x 300A\/5A CTs included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModbus RTU communication:\u003c\/strong\u003e RS485 for integration with Solis inverters and EPM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBi-directional metering:\u003c\/strong\u003e Measures imported and exported energy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN rail mount:\u003c\/strong\u003e Compact 72mm (4-module) width for easy panel installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh accuracy:\u003c\/strong\u003e Class 1 for active energy, Class 2 for reactive energy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e SDM630MCT V2 – Three-Phase Energy Meter with CTs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three-phase (3P4W\/3P3W\/1P2W).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage rating:\u003c\/strong\u003e 3x230\/400V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent input:\u003c\/strong\u003e 1A\/5A via CT (3 x 300A\/5A CTs included).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.5% for voltage\/current, ±1% for power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e RS485 Modbus RTU (baud rates 2400-38400).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -25°C to +55°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection rating:\u003c\/strong\u003e IP51 (front), suitable for indoor use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDimensions \u0026amp; Weights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeter width:\u003c\/strong\u003e 72 mm (4 DIN modules).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeter depth:\u003c\/strong\u003e 65 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeter height:\u003c\/strong\u003e 90 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT inner diameter:\u003c\/strong\u003e ~36 mm (for 300A CTs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (meter):\u003c\/strong\u003e ~0.4 kg.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (per CT):\u003c\/strong\u003e ~0.3 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSystem \u0026amp; Application Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for Solis 3-phase inverters for export limitation, zero-export, and energy monitoring.\u003c\/li\u003e\n\u003cli\u003eCompatible with Solis EPM for advanced power management.\u003c\/li\u003e\n\u003cli\u003eSuitable for residential and commercial PV systems requiring grid compliance.\u003c\/li\u003e\n\u003cli\u003eInstallation by qualified electricians; CTs clip around phase conductors.\u003c\/li\u003e\n\u003cli\u003eUse in conjunction with Solis inverters for accurate data logging and control.\u003c\/li\u003e\n\u003cli\u003eWarranty: 2 years standard (confirm with supplier).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Eastron","offers":[{"title":"Default Title","offer_id":63258959151453,"sku":"SOL-METER-3PH-EASTRON","price":147.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Eastron3phMeterwith3CTs300A.jpg?v=1769964563"},{"product_id":"iskra-mt174-ct-3-ph-ct-operated-generation-meter","title":"ISKRA MT174 CT - 3-ph CT Operated Generation Meter","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eISKRA MT174 CT - 3-ph CT Operated Generation Meter \u003c\/strong\u003eis a MID-certified three-phase electronic meter designed for accurate measurement and registration of active, reactive, and apparent energy in solar PV and generation systems, with CT operation for high-current applications.\u003c\/p\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe Iskra MT174 CT is a polyphase multi-tariff meter suitable for import\/export metering in three-phase networks. It features CT operation with a 200\/5A ratio, making it ideal for larger installations where direct connection is not feasible. With photovoltaic readiness and anti-tampering protection, it ensures reliable performance in renewable energy setups. The meter supports up to four tariffs, RS485 communication, and pulse outputs for integration with energy management systems.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMID certified:\u003c\/strong\u003e Compliant for billing and accurate energy metering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImport\/export metering:\u003c\/strong\u003e Measures bidirectional energy flow for generation and consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT operated:\u003c\/strong\u003e 200\/5A ratio for high-current applications without direct wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-tariff support:\u003c\/strong\u003e Up to four tariffs with external changeover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication interfaces:\u003c\/strong\u003e RS485 and optical port for data retrieval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse outputs:\u003c\/strong\u003e Two configurable outputs for energy or demand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-tampering package:\u003c\/strong\u003e Extensive protection against fraud.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotovoltaic ready:\u003c\/strong\u003e Designed for solar PV integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e MT174 CT – Three-Phase CT Operated Generation Meter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three-phase (3P4W).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3 x 230\/400 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent rating:\u003c\/strong\u003e 5 A (via CT, 200\/5A ratio).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy class:\u003c\/strong\u003e Class B (active energy EN 50470-3), Class 2 (reactive energy).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e RS485, optical port (IEC 62056-21).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -40°C to +60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection rating:\u003c\/strong\u003e IP54.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDimensions \u0026amp; Weights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 177 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 155 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 216 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~1.5 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSystem \u0026amp; Application Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for solar PV generation metering, export limitation, and billing in three-phase systems.\u003c\/li\u003e\n\u003cli\u003eCompatible with Solis and other inverters requiring CT-operated metering.\u003c\/li\u003e\n\u003cli\u003eSuitable for mechanical environment M1, electromagnetic E2.\u003c\/li\u003e\n\u003cli\u003eInstallation by qualified electricians; CTs connect to current terminals.\u003c\/li\u003e\n\u003cli\u003eSupports DIN rail mounting; use in 3- or 4-wire networks.\u003c\/li\u003e\n\u003cli\u003eWarranty: Standard manufacturer warranty (confirm with supplier).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Iskra","offers":[{"title":"Default Title","offer_id":63263364677981,"sku":"ISKRA-MT174-CT","price":130.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Iskra-MT174-CT-MID.jpg?v=1770003632"},{"product_id":"l-g-3-ph-generation-meter-zmd410-200a-100-pulse-kwh","title":"L\u0026G 3-ph generation meter ZMD410 200A - 100 pulse\/kWh","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eL\u0026amp;G 3-ph generation meter ZMD410 200A (100 pulse\/kWh)\u003c\/strong\u003e is a MID-certified three-phase CT-operated electronic meter designed for accurate measurement of active energy in solar PV and generation systems, with pulse output for integration with energy management.\u003c\/p\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe Landis+Gyr ZMD410 is a high-precision polyphase meter suitable for import\/export metering in three-phase networks up to 200A (~140kW systems). It features CT operation with a 200\/5A ratio, making it ideal for larger installations. With MID certification and photovoltaic readiness, it ensures reliable performance in renewable energy setups. The meter supports pulse outputs for remote reading and integration with inverters or monitoring systems.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMID certified:\u003c\/strong\u003e Compliant for billing and accurate energy metering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT operated:\u003c\/strong\u003e 200\/5A ratio for high-current applications without direct wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse output:\u003c\/strong\u003e 100 pulses per kWh for easy integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImport\/export metering:\u003c\/strong\u003e Measures bidirectional energy flow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo output contacts:\u003c\/strong\u003e For additional control or signaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad profiles:\u003c\/strong\u003e Up to 2 independent profiles for billing and quality measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTariff functions:\u003c\/strong\u003e Average demand, TOU (Time of Use).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-tampering:\u003c\/strong\u003e Extensive protection against fraud.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e ZMD410 – Three-Phase CT-Operated Generation Meter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase:\u003c\/strong\u003e Three-phase (3P4W\/3P3W).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e 3 x 230\/400 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent rating:\u003c\/strong\u003e 200\/5A (CT operated).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy class:\u003c\/strong\u003e Class 1 (active energy), Class 2 (reactive energy).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse constant:\u003c\/strong\u003e 100 pulses\/kWh.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -40°C to +60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection rating:\u003c\/strong\u003e IP54.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDimensions \u0026amp; Weights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 177 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 155 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 216 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e ~1.5 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSystem \u0026amp; Application Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for solar PV generation metering up to ~140kW, export limitation, and billing.\u003c\/li\u003e\n\u003cli\u003eCompatible with Solis and other inverters requiring CT-operated metering.\u003c\/li\u003e\n\u003cli\u003eSuitable for mechanical environment M1, electromagnetic E2.\u003c\/li\u003e\n\u003cli\u003eInstallation by qualified electricians; requires CTs (not included in this part no.).\u003c\/li\u003e\n\u003cli\u003eSupports DIN rail mounting; use in 3- or 4-wire networks.\u003c\/li\u003e\n\u003cli\u003eWarranty: Standard manufacturer warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Landis+Gyr","offers":[{"title":"Default Title","offer_id":63263386698077,"sku":"ZMD410","price":450.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Landisgyr3-phgenerationmeterZMD410.jpg?v=1770004297"},{"product_id":"solis-meter-1ph-eastron-with-external-ct-sdm120ct","title":"Solis Eastron SDM120CT Single-Phase MID Meter | External CT | RS485","description":"\u003c!-- SEO Product Name: Eastron SDM120CT Single-Phase MID Meter | External CT | RS485 --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; color:#1a1a1a; line-height:1.6;\"\u003e\n\u003cp style=\"margin:0 0 16px 0;\"\u003eThe \u003cstrong\u003eEastron SDM120CT single-phase energy meter\u003c\/strong\u003e is a compact, \u003cstrong\u003eCT-operated multifunction meter\u003c\/strong\u003e built for export limitation, zero-export control, and consumption monitoring on single-phase Solis hybrid inverter systems. Supplied complete with a clip-on \u003cstrong\u003eexternal current transformer (100A:100mA)\u003c\/strong\u003e, it installs without breaking into the live conductor, measuring imported and exported energy, voltage, current, power, power factor, and frequency with \u003cstrong\u003eMID-certified billing accuracy\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 16px 0;\"\u003eCommunication runs over \u003cstrong\u003eRS485 Modbus RTU or DLT645\u003c\/strong\u003e, giving Solis inverters (and other compatible monitoring platforms) the live import\/export data needed for accurate export limitation and self-consumption optimisation. The meter is \u003cstrong\u003eDIN rail mounted\u003c\/strong\u003e, requires no external power source beyond the monitored circuit, and reports to \u003cstrong\u003eClass 1 accuracy\u003c\/strong\u003e for active energy.\u003c\/p\u003e\n\n    \u003cdiv style=\"display:flex; flex-wrap:wrap; gap:10px; margin:0 0 24px 0;\"\u003e\n        \n        \u003cdiv style=\"flex:1 1 140px; min-width:140px; background:#f4faf9; border-top:3px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center;\"\u003e\n            \u003cdiv style=\"font-size:20px; font-weight:700; color:#008377CF;\"\u003eClass 1\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; color:#444; margin-top:4px; line-height:1.3;\"\u003eActive energy accuracy\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 140px; min-width:140px; background:#f4faf9; border-top:3px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center;\"\u003e\n            \u003cdiv style=\"font-size:20px; font-weight:700; color:#008377CF;\"\u003e100A:100mA\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; color:#444; margin-top:4px; line-height:1.3;\"\u003eExternal CT ratio\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 140px; min-width:140px; background:#f4faf9; border-top:3px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center;\"\u003e\n            \u003cdiv style=\"font-size:20px; font-weight:700; color:#008377CF;\"\u003e230V\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; color:#444; margin-top:4px; line-height:1.3;\"\u003eRated voltage, 1P+N\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 140px; min-width:140px; background:#f4faf9; border-top:3px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center;\"\u003e\n            \u003cdiv style=\"font-size:20px; font-weight:700; color:#008377CF;\"\u003eRS485\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; color:#444; margin-top:4px; line-height:1.3;\"\u003eModbus RTU \/ DLT645\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 140px; min-width:140px; background:#f4faf9; border-top:3px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center;\"\u003e\n            \u003cdiv style=\"font-size:20px; font-weight:700; color:#008377CF;\"\u003eMID\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; color:#444; margin-top:4px; line-height:1.3;\"\u003eCertified for billing\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 140px; min-width:140px; background:#f4faf9; border-top:3px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center;\"\u003e\n            \u003cdiv style=\"font-size:20px; font-weight:700; color:#008377CF;\"\u003e18mm\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; color:#444; margin-top:4px; line-height:1.3;\"\u003eDIN rail module width\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#eaf6f4; border-left:4px solid #008377CF; border-radius:4px; padding:14px 16px; margin:0 0 18px 0;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#04463d; margin-bottom:4px;\"\u003eBuilt for Solis hybrid inverter export control\u003c\/div\u003e\n        \u003cdiv style=\"color:#04463d; font-size:14.5px; line-height:1.55;\"\u003eThis meter pairs with \u003cstrong\u003eSolis single-phase hybrid inverters\u003c\/strong\u003e to provide the live grid import\/export reading the inverter needs for \u003cstrong\u003eexport power limitation\u003c\/strong\u003e and \u003cstrong\u003e24-hour consumption monitoring\u003c\/strong\u003e. It is preset for direct installation, so no on-meter parameter changes are required before commissioning.\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background:#fff8ea; border-left:4px solid #c8860d; border-radius:4px; padding:14px 16px; margin:0 0 18px 0;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#6b4a04; margin-bottom:4px;\"\u003eCT current direction and loop safety\u003c\/div\u003e\n        \u003cdiv style=\"color:#6b4a04; font-size:14.5px; line-height:1.55;\"\u003eThe external CT must be fitted with the correct current direction (per the arrow marking) around the live conductor only, and the upstream\/downstream supply must be isolated before installation to avoid electric shock. Confirm Modbus address, baud rate, and parity match the inverter or monitoring platform configuration before commissioning.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"display:flex; flex-wrap:wrap; gap:14px; margin:0 0 26px 0;\"\u003e\n        \n        \u003cdiv style=\"flex:1 1 260px; min-width:240px; background:#ffffff; border:1px solid #e2e2e2; border-top:3px solid #008377CF; border-radius:6px; padding:16px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px; font-size:15px;\"\u003eExternal CT, clip-on install\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14px; color:#333; line-height:1.55;\"\u003eSupplied with a \u003cstrong\u003e100A:100mA split-core current transformer\u003c\/strong\u003e that clips around the live conductor — no need to break the circuit or disconnect existing wiring runs during fitting.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 260px; min-width:240px; background:#ffffff; border:1px solid #e2e2e2; border-top:3px solid #008377CF; border-radius:6px; padding:16px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px; font-size:15px;\"\u003eMID-certified for billing\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14px; color:#333; line-height:1.55;\"\u003eCertified to \u003cstrong\u003eEU Directive 2014\/32\/EU\u003c\/strong\u003e (MID certificate 0120\/SGS0141), so readings are suitable for tariff billing and formal energy accounting, not just indicative monitoring.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 260px; min-width:240px; background:#ffffff; border:1px solid #e2e2e2; border-top:3px solid #008377CF; border-radius:6px; padding:16px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px; font-size:15px;\"\u003eBi-directional energy metering\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14px; color:#333; line-height:1.55;\"\u003eIndependently tracks \u003cstrong\u003eimported and exported active\/reactive energy\u003c\/strong\u003e, supporting export limitation, zero-export configurations, and self-consumption reporting on grid-tied PV systems.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 260px; min-width:240px; background:#ffffff; border:1px solid #e2e2e2; border-top:3px solid #008377CF; border-radius:6px; padding:16px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px; font-size:15px;\"\u003eRS485 Modbus RTU \/ DLT645\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14px; color:#333; line-height:1.55;\"\u003eCommunicates over \u003cstrong\u003eRS485\u003c\/strong\u003e using Modbus RTU (configurable baud rate 1200–9600 bps) or DLT645, for integration with Solis inverters or third-party monitoring and BMS platforms.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 260px; min-width:240px; background:#ffffff; border:1px solid #e2e2e2; border-top:3px solid #008377CF; border-radius:6px; padding:16px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px; font-size:15px;\"\u003eTwo pulse outputs\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14px; color:#333; line-height:1.55;\"\u003eA \u003cstrong\u003econfigurable pulse output\u003c\/strong\u003e (default 0.001 kWh\/pulse, total\/import\/export selectable) plus a fixed \u003cstrong\u003e1000 imp\/kWh\u003c\/strong\u003e output for straightforward remote metering integration.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 260px; min-width:240px; background:#ffffff; border:1px solid #e2e2e2; border-top:3px solid #008377CF; border-radius:6px; padding:16px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px; font-size:15px;\"\u003eCompact DIN rail housing\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14px; color:#333; line-height:1.55;\"\u003eJust \u003cstrong\u003e18mm wide\u003c\/strong\u003e on a standard DIN rail, so it drops into an existing consumer unit or inverter enclosure without needing extra panel space.\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 26px 0; display:flex; flex-direction:column; gap:18px;\"\u003e\n    \u003cdiv style=\"margin:0 0 4px 0;\"\u003e\n        \u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px; border-radius:6px 6px 0 0; font-size:14.5px;\"\u003eElectrical\u003c\/div\u003e\n        \u003cdiv style=\"border:1px solid #ececec; border-top:none; border-radius:0 0 6px 6px; overflow:hidden;\"\u003e\n            \n        \u003cdiv style=\"display:flex; background:#f7fbfa; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eRated voltage\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e230V AC, single phase (1P+N)\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#ffffff; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eInput current\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e100mA (via external CT, 100A:100mA ratio)\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#f7fbfa; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eOperational frequency\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e50\/60Hz\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#ffffff; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eInternal power consumption\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e≤ 2W \/ 10VA\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"margin:0 0 4px 0;\"\u003e\n        \u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px; border-radius:6px 6px 0 0; font-size:14.5px;\"\u003eAccuracy\u003c\/div\u003e\n        \u003cdiv style=\"border:1px solid #ececec; border-top:none; border-radius:0 0 6px 6px; overflow:hidden;\"\u003e\n            \n        \u003cdiv style=\"display:flex; background:#f7fbfa; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eVoltage\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e±0.5%\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#ffffff; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eCurrent\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e±0.5%\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#f7fbfa; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003ePower (P, Q, S)\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e±1%\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#ffffff; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eActive energy\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003eClass 1 (±1%)\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#f7fbfa; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eReactive energy\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e±2%\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"margin:0 0 4px 0;\"\u003e\n        \u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px; border-radius:6px 6px 0 0; font-size:14.5px;\"\u003eCommunication\u003c\/div\u003e\n        \u003cdiv style=\"border:1px solid #ececec; border-top:none; border-radius:0 0 6px 6px; overflow:hidden;\"\u003e\n            \n        \u003cdiv style=\"display:flex; background:#f7fbfa; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eInterface\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003eRS485, Modbus RTU or DLT645\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#ffffff; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eModbus baud rate\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e1200 \/ 2400 \/ 4800 \/ 9600 bps\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#f7fbfa; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eModbus address range\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e1–247\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#ffffff; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003ePulse output 1\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003eConfigurable — 0.001\/0.01\/0.1\/1 kWh or kVarh per pulse\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#f7fbfa; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003ePulse output 2\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003eFixed, 1000 imp\/kWh\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"margin:0 0 4px 0;\"\u003e\n        \u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px; border-radius:6px 6px 0 0; font-size:14.5px;\"\u003eCertification \u0026amp; standards\u003c\/div\u003e\n        \u003cdiv style=\"border:1px solid #ececec; border-top:none; border-radius:0 0 6px 6px; overflow:hidden;\"\u003e\n            \n        \u003cdiv style=\"display:flex; background:#f7fbfa; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eBilling certification\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003eMID (EU Directive 2014\/32\/EU), certificate 0120\/SGS0141\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#ffffff; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eReference standard\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003eIEC 62053-21 \/ EN 50470-1\/3\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#f7fbfa; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eInstallation category\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003eCAT III\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"margin:0 0 4px 0;\"\u003e\n        \u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px; border-radius:6px 6px 0 0; font-size:14.5px;\"\u003ePhysical \u0026amp; environmental\u003c\/div\u003e\n        \u003cdiv style=\"border:1px solid #ececec; border-top:none; border-radius:0 0 6px 6px; overflow:hidden;\"\u003e\n            \n        \u003cdiv style=\"display:flex; background:#f7fbfa; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eDimensions (W x D x H)\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e18mm x 64mm x 118mm\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#ffffff; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eWeight\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003eApprox. 0.3kg\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#f7fbfa; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eMounting\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e35mm DIN rail\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#ffffff; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eOperating temperature\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e-25°C to +55°C\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#f7fbfa; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eStorage temperature\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e-40°C to +70°C\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#ffffff; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eRelative humidity\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003e\u0026lt; 95%, non-condensing\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"display:flex; background:#f7fbfa; padding:9px 14px; border-bottom:1px solid #ececec;\"\u003e\n            \u003cdiv style=\"flex:0 0 46%; font-weight:600; color:#222; font-size:14px;\"\u003eProtection rating\u003c\/div\u003e\n            \u003cdiv style=\"flex:1; color:#333; font-size:14px;\"\u003eIP51 (indoor use)\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\n    \u003cdiv style=\"margin:8px 0 0 0;\"\u003e\n        \u003cdiv style=\"font-weight:700; font-size:17px; color:#111; margin:0 0 12px 0;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n        \n    \u003cdetails style=\"margin:0 0 8px 0; border:1px solid #e2e2e2; border-radius:6px; overflow:hidden;\"\u003e\n        \u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:12px 16px; cursor:pointer; list-style:none; font-size:14.5px;\"\u003eDoes this meter work with Solis inverters other than single-phase hybrids?\u003c\/summary\u003e\n        \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#333; line-height:1.6; background:#ffffff;\"\u003eThe SDM120CT is a \u003cstrong\u003esingle-phase CT-operated meter\u003c\/strong\u003e designed for Solis single-phase hybrid inverter installations requiring export limitation or consumption monitoring. Three-phase Solis systems require the equivalent three-phase Eastron meter instead.\u003c\/div\u003e\n    \u003c\/details\u003e\n    \u003cdetails style=\"margin:0 0 8px 0; border:1px solid #e2e2e2; border-radius:6px; overflow:hidden;\"\u003e\n        \u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:12px 16px; cursor:pointer; list-style:none; font-size:14.5px;\"\u003eIs the external CT included, or sold separately?\u003c\/summary\u003e\n        \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#333; line-height:1.6; background:#ffffff;\"\u003eThe \u003cstrong\u003e100A:100mA external current transformer is included\u003c\/strong\u003e with this meter — it is not sold separately and no additional CT purchase is required for a standard single-phase installation.\u003c\/div\u003e\n    \u003c\/details\u003e\n    \u003cdetails style=\"margin:0 0 8px 0; border:1px solid #e2e2e2; border-radius:6px; overflow:hidden;\"\u003e\n        \u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:12px 16px; cursor:pointer; list-style:none; font-size:14.5px;\"\u003eCan this meter be used purely for billing, not just Solis export control?\u003c\/summary\u003e\n        \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#333; line-height:1.6; background:#ffffff;\"\u003eYes. It is \u003cstrong\u003eMID certified\u003c\/strong\u003e, so the readings are legally suitable for tariff billing and formal energy accounting as well as inverter export limitation and consumption monitoring.\u003c\/div\u003e\n    \u003c\/details\u003e\n    \u003cdetails style=\"margin:0 0 8px 0; border:1px solid #e2e2e2; border-radius:6px; overflow:hidden;\"\u003e\n        \u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:12px 16px; cursor:pointer; list-style:none; font-size:14.5px;\"\u003eWho should install this meter?\u003c\/summary\u003e\n        \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#333; line-height:1.6; background:#ffffff;\"\u003eInstallation involves live electrical connections and should be carried out by a \u003cstrong\u003equalified electrician\u003c\/strong\u003e, with the upstream and downstream supply isolated before fitting the CT and wiring the meter, in line with current UK wiring regulations (BS 7671).\u003c\/div\u003e\n    \u003c\/details\u003e\n    \u003cdetails style=\"margin:0 0 8px 0; border:1px solid #e2e2e2; border-radius:6px; overflow:hidden;\"\u003e\n        \u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:12px 16px; cursor:pointer; list-style:none; font-size:14.5px;\"\u003eWhat communication protocol does it use with the inverter?\u003c\/summary\u003e\n        \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#333; line-height:1.6; background:#ffffff;\"\u003eThe meter communicates over \u003cstrong\u003eRS485\u003c\/strong\u003e using either \u003cstrong\u003eModbus RTU\u003c\/strong\u003e or \u003cstrong\u003eDLT645\u003c\/strong\u003e, selectable to match the Solis inverter or third-party monitoring platform it is connected to.\u003c\/div\u003e\n    \u003c\/details\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Solis","offers":[{"title":"Default Title","offer_id":63263789121885,"sku":"SDM120CTM","price":77.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SolisMeter1phEastronwithexternalCT-SDM120CT.jpg?v=1770012461"},{"product_id":"givenergy-meter-3ph-eastron-v2-with-ct","title":"Eastron SDM630MCT V2 Three Phase CT Energy Meter with CT Clamps — DIN Rail Modbus RS485 MID Certified Solar Import Export","description":"\u003cdiv style=\"font-size:16px;font-family:Arial,Helvetica,sans-serif;color:#1a1a1a;max-width:900px;margin:0 auto;line-height:1.6;\"\u003e\n\n  \u003c!-- ── INTRO ─────────────────────────────────────────────────────── --\u003e\n  \u003cp style=\"margin:0 0 18px;\"\u003e\n    The \u003cstrong\u003eEastron SDM630MCT V2\u003c\/strong\u003e is a \u003cstrong\u003ethree-phase multi-function CT-operated energy meter\u003c\/strong\u003e for DIN rail mounting, supplied complete with \u003cstrong\u003ethree CT clamps\u003c\/strong\u003e. It measures and displays a comprehensive set of electrical parameters — including import and export kWh, voltage, current, power, power factor, frequency, and THD — across single-phase (1P2W) and three-phase (3P3W and 3P4W) supplies. Connectivity via \u003cstrong\u003eRS485 Modbus RTU\u003c\/strong\u003e enables integration with solar inverters, hybrid battery systems, energy management platforms, and building management systems (BMS). The meter is \u003cstrong\u003eMID B+D certified\u003c\/strong\u003e (EU Directive 2014\/32\/EU, certificate 0120\/SGS0142) and ETL registered, meeting the legal accuracy and certification requirements for revenue-grade energy measurement. Rated at \u003cstrong\u003eClass 1.0 accuracy\u003c\/strong\u003e for active energy, with a \u003cstrong\u003e1A or 5A CT input\u003c\/strong\u003e, it works with a wide range of current transformers. DIN rail mounted, \u003cstrong\u003eIP51 rated\u003c\/strong\u003e, and sized at 94.5 × 72 × 65mm for compact panel installation.\n  \u003c\/p\u003e\n\n  \u003c!-- ── STAT STRIP ─────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin-bottom:20px;\"\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:19px;font-weight:700;\"\u003e3-Phase\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003e3P4W \/ 3P3W \/ 1P2W\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:19px;font-weight:700;\"\u003eClass 1.0\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eActive energy accuracy\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:19px;font-weight:700;\"\u003eRS485\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eModbus RTU\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:19px;font-weight:700;\"\u003eMID\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eB+D certified\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:19px;font-weight:700;\"\u003e3× CT\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eClamps included\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── TEAL USE-CASE CALLOUT ─────────────────────────────────────── --\u003e\n  \u003cdiv style=\"border-left:4px solid #008377CF;background:#e6f4f3;padding:10px 16px;margin-bottom:22px;border-radius:0 6px 6px 0;\"\u003e\n    \u003cstrong style=\"color:#005c54;\"\u003eℹ Typical Applications\u003c\/strong\u003e\u003cbr\u003e\n    The SDM630MCT V2 is widely used as a \u003cstrong\u003egrid import\/export meter for solar PV and battery storage systems\u003c\/strong\u003e — providing the hybrid inverter or energy management system with real-time grid consumption and export data for zero-export control, self-consumption optimisation, and tariff scheduling. It is also used in \u003cstrong\u003eEV charging metering\u003c\/strong\u003e, \u003cstrong\u003esub-metering of commercial and industrial premises\u003c\/strong\u003e, and as a \u003cstrong\u003egeneral-purpose three-phase energy monitoring solution\u003c\/strong\u003e wherever Modbus RS485 communication is required. CT installation means no interruption to supply is needed during installation — the clamps simply clip around live cables.\n  \u003c\/div\u003e\n\n  \u003c!-- ── FEATURES GRID ──────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Features \u0026amp; Benefits\n  \u003c\/div\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(255px,1fr));gap:12px;background:#e6f4f3;padding:14px;border-radius:0 0 6px 6px;margin-bottom:22px;\"\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ CT Clamp Installation — No Supply Interruption\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eCurrent measurement via \u003cstrong\u003eclip-on CT clamps\u003c\/strong\u003e (three included) means the meter can be installed on live cables without disconnecting supply to the property. The clamps close around the live conductors on each phase at the incoming supply — there is no need to break connections, cut wires, or isolate the supply for the current measurement side of the installation. Only the meter's own auxiliary supply (from the incoming voltage terminals) requires a brief connection.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Bi-Directional — Import \u0026amp; Export\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe SDM630MCT V2 measures \u003cstrong\u003eboth import (from grid) and export (to grid) energy\u003c\/strong\u003e independently — reporting both Imp_kWh and Exp_kWh. Negative power readings are also supported, with a CT reversal indicator for incorrect installation detection. This bi-directional capability is essential for solar PV monitoring, where the meter must distinguish between energy drawn from the grid and energy sent back to it, enabling accurate SEG (Smart Export Guarantee) calculations and self-consumption tracking.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ RS485 Modbus RTU — Universal Integration\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe RS485 Modbus RTU interface communicates with \u003cstrong\u003eup to 64 devices on a single bus at up to 1,000m cable distance\u003c\/strong\u003e, using standard baud rates from 2,400 to 38,400 bps. Modbus is the standard protocol for integration with solar hybrid inverters, battery storage systems, EV charge point management systems, and BMS platforms. The meter's Modbus register map is publicly available, enabling direct integration with custom systems and third-party monitoring platforms.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ 16 Measured Parameters\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe meter's backlit LCD display cycles through \u003cstrong\u003e16 measurement parameters\u003c\/strong\u003e: kWh (import and export), kVArh, kW, kVAr, kVA, voltage (per phase), current (per phase), power factor, frequency, THD (total harmonic distortion), and maximum demand current. All parameters are simultaneously available via Modbus for real-time and historical data access by connected systems. The LCD display enables on-site reading without a connected device.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ MID B+D Certified — Revenue Grade\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eMID (Measuring Instruments Directive) certification to EU Directive 2014\/32\/EU — certificate number \u003cstrong\u003e0120\/SGS0142\u003c\/strong\u003e — confirms the meter meets the legal accuracy and construction requirements for \u003cstrong\u003efiscal (billing) energy measurement\u003c\/strong\u003e in the UK and EU. B+D certification covers both the metering accuracy (Module B) and the quality system (Module D). ETL registration by Intertek confirms compliance with North American standards. This level of certification is required for energy measurement used in billing, sub-metering, and lease arrangements.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Flexible CT Input Options\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe standard SDM630MCT V2 accepts \u003cstrong\u003e1A or 5A secondary output CT clamps\u003c\/strong\u003e — the most common standard for metering CTs — enabling use with a wide range of primary current ratings from small domestic to large commercial installations. The meter can also be specified in variants for 40mA, 100mV, and 333mV CT inputs for specialist applications. The CT ratio is programmable via the configuration buttons on the meter, allowing accurate scaling for any current transformer ratio.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Configurable Pulse Output\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eTwo \u003cstrong\u003econfigurable pulse outputs\u003c\/strong\u003e allow the meter to send energy pulse signals to external counters, data loggers, or monitoring equipment — Pulse Output 2 is fixed at 3,200 impulses\/kWh. This enables integration with systems that accept pulse inputs rather than Modbus, including some older BMS platforms and standalone energy loggers. Pulse outputs are useful for simple energy counting without requiring a Modbus-capable controller.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ DIN Rail — IP51 — Compact\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eStandard 35mm DIN rail mounting at \u003cstrong\u003e94.5 × 72 × 65mm\u003c\/strong\u003e fits neatly in a standard domestic consumer unit, commercial distribution board, or dedicated meter enclosure. IP51 protection provides dust and drip resistance for installation in electrical panels. The compact 4-module width occupies minimal rail space. Operating temperature range –25°C to +55°C covers all UK indoor installation environments.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- ── SPEC TABLE ─────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Technical Specifications\n  \u003c\/div\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:22px;font-size:14px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\u003ctd style=\"padding:9px 14px;font-weight:600;width:44%;border-bottom:1px solid #c8e6e3;\" colspan=\"2\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eEastron Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSDM630MCT V2 (Modbus)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eMeasurement Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e3P4W, 3P3W, 1P2W — single or three phase\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eMID B+D (EU 2014\/32\/EU, cert. 0120\/SGS0142); ETL (Intertek); Class 1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eIEC 62053-21 \/ EN50470-1\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\" colspan=\"2\"\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e3 × 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e80%–120% of nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eCT Input (rated)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003e1A or 5A\u003c\/strong\u003e (standard) — also available as 40mA \/ 100mV \/ 333mV variants\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eCT Clamps Supplied\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e3 × CT clamps\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e≤ 2W \/ 10VA per phase\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\" colspan=\"2\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eActive Energy\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eClass 1 (±1% typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eReactive Energy\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eClass 2\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eVoltage \/ Current\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e±1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e0.2% of mid-frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\" colspan=\"2\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eProtocol\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eModbus RTU via RS485 (semi-duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eBaud Rate\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e2,400 \/ 4,800 \/ 9,600 \/ 19,200 \/ 38,400 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eAddress Range\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1–247\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eMax Bus Loading\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e64 devices\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eMax Communication Distance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003ePulse Outputs\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e2 — Output 1: configurable; Output 2: 3,200 imp\/kWh (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\" colspan=\"2\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e94.5 × 72 × 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e35mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eIP51 (indoor)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;\"\u003e≤ 90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- ── FAQ ────────────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Frequently Asked Questions\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #c8e6e3;border-top:none;border-radius:0 0 6px 6px;margin-bottom:8px;\"\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eWhich hybrid inverters and battery systems is this meter compatible with?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eThe SDM630MCT V2 communicates via standard \u003cstrong\u003eModbus RTU over RS485\u003c\/strong\u003e — the industry-standard protocol for energy meter integration. It is compatible with the vast majority of hybrid inverters and battery storage systems that require an external grid meter, including Sunsynk (Ecco and standard ranges), Solis, Fox ESS, SolarEdge, Fronius, Huawei, Sungrow, and others. Always confirm the specific Modbus register map and CT input specification required by your inverter manufacturer. Some inverters require the meter's Modbus address and baud rate to be set to specific values during commissioning.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#fff;\"\u003eDoes this work on a single-phase (1P2W) property?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eYes — the SDM630MCT V2 supports \u003cstrong\u003esingle-phase two-wire (1P2W) configuration\u003c\/strong\u003e in addition to three-phase configurations. For a single-phase property, only one CT clamp is required (on the live conductor at the incoming supply), and the meter is configured for 1P2W mode via its display buttons. This makes the SDM630MCT V2 a single product suitable for both single and three-phase applications, simplifying procurement.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eWhat does MID certification mean, and is it required?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eMID (Measuring Instruments Directive) certification confirms the meter has been independently assessed and meets the legal requirements for \u003cstrong\u003elegal-for-trade (fiscal) energy measurement\u003c\/strong\u003e in the UK and EU. It is required where the meter reading is used for billing, in sub-metering situations where tenants are charged for energy consumption, or in any contractual energy measurement role. For domestic solar monitoring and self-consumption optimisation (where no billing is involved), MID certification is not legally required — but it does confirm the meter is built and tested to a high accuracy standard. This meter's MID certificate number is 0120\/SGS0142.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#fff;\"\u003eCan the meter be installed without disconnecting supply?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eThe CT clamps can be fitted around live cables without disconnecting supply — they simply clip around each phase conductor at the incoming supply point, typically in the consumer unit or distribution board. \u003cstrong\u003eHowever, the meter's voltage sensing terminals must be connected to each phase and neutral\u003c\/strong\u003e, and this wiring must be carried out by a qualified electrician with the supply isolated or under careful live-working conditions. Installation in a consumer unit or distribution board constitutes electrical installation work under Part P of the Building Regulations in England — it must be carried out or certificated by a Part P registered electrician.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Eastron","offers":[{"title":"Default Title","offer_id":63263806030173,"sku":"METER-3PH-EASTRON","price":150.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SolisMeter3PHEastronV2withCT.png?v=1770012854"},{"product_id":"sigenergy-sigen-energy-gateway-homepro-sp-f-100a-single-phase-whole-home-backup","title":"Sigenergy Sigen Energy Gateway HomePro SP-F 100A Single Phase Whole-Home Backup","description":"\u003cstyle\u003e\n  .sgs-desc * { box-sizing: border-box; }\n  .sgs-desc { font-family: inherit; color: inherit; line-height: 1.7; font-size: 16px; }\n  .sgs-desc p, .sgs-desc li, .sgs-desc td, .sgs-desc th { font-size: 16px !important; line-height: 1.7; }\n  .sgs-desc h2 { font-size: 22px !important; font-weight: 700; color: #0d1a2e; border-bottom: 2px solid #e8401c; padding-bottom: 6px; margin: 2rem 0 1rem; line-height: 1.3; }\n  .sgs-desc h3 { font-size: 17px !important; font-weight: 700; color: #0d1a2e; margin: 1.2rem 0 0.4rem; line-height: 1.4; }\n  .sgs-desc p { margin: 0 0 1rem; }\n  .sgs-desc ul { padding-left: 1.5rem; margin: 0 0 1rem; }\n  .sgs-desc ul li { margin-bottom: 0.5rem; }\n\n  .sgs-intro-box { background: #fdf0ed; border-left: 4px solid #e8401c; padding: 1.1rem 1.4rem; border-radius: 0 6px 6px 0; margin-bottom: 1.5rem; }\n  .sgs-intro-box p { margin: 0 !important; }\n\n  .sgs-badge { display: inline-block; background: #e8401c; color: #fff; font-size: 13px !important; font-weight: 700; border-radius: 4px; padding: 2px 10px; margin-right: 6px; margin-bottom: 4px; vertical-align: middle; }\n  .sgs-badge.dark { background: #0d1a2e; }\n  .sgs-badge.grey { background: #555; }\n  .sgs-badge.green { background: #1a7a3c; }\n\n  .sgs-stat-bar { background: #0d1a2e; color: #fff; border-radius: 8px; padding: 1.1rem 1.4rem; margin: 1.2rem 0; display: flex; flex-wrap: wrap; gap: 1.5rem; align-items: center; justify-content: space-around; }\n  .sgs-stat { text-align: center; }\n  .sgs-stat .num { font-size: 26px !important; font-weight: 800; color: #ff7a5a; line-height: 1; }\n  .sgs-stat .lbl { font-size: 12px !important; color: #aab; margin-top: 2px; }\n\n  .sgs-grid { display: grid; grid-template-columns: repeat(auto-fill, minmax(230px, 1fr)); gap: 0.85rem; margin-bottom: 1.2rem; }\n  .sgs-card { background: #fdf0ed; border: 1px solid #f5c4b8; border-radius: 6px; padding: 1rem 1.1rem; line-height: 1.6; }\n  .sgs-card strong { display: block; color: #0d1a2e; margin-bottom: 0.35rem; font-size: 16px !important; }\n\n  .sgs-flow-grid { display: grid; grid-template-columns: repeat(auto-fill, minmax(160px, 1fr)); gap: 0.7rem; margin-bottom: 1.2rem; }\n  .sgs-flow-item { background: #0d1a2e; color: #fff; border-radius: 6px; padding: 0.85rem 1rem; text-align: center; font-size: 15px !important; line-height: 1.5; }\n  .sgs-flow-item .icon { font-size: 22px !important; display: block; margin-bottom: 0.3rem; }\n  .sgs-flow-item strong { display: block; color: #ff7a5a; font-size: 14px !important; margin-bottom: 0.2rem; }\n\n  .sgs-compare-table { width: 100%; border-collapse: collapse; margin-bottom: 1.2rem; }\n  .sgs-compare-table th { background: #0d1a2e; color: #fff !important; padding: 0.65rem 0.9rem; font-size: 15px !important; text-align: left; }\n  .sgs-compare-table th:not(:first-child) { text-align: center; }\n  .sgs-compare-table td { padding: 0.55rem 0.9rem; border-bottom: 1px solid #e8e0de; font-size: 15px !important; }\n  .sgs-compare-table td:not(:first-child) { text-align: center; }\n  .sgs-compare-table tr:nth-child(even) td { background: #fdf0ed; }\n  .sgs-compare-table td:first-child { font-weight: 600; color: #111; }\n  .sgs-compare-table .col-highlight { font-weight: 700; color: #e8401c !important; }\n\n  .sgs-callout { background: #fff8e6; border: 1px solid #f0d080; border-radius: 6px; padding: 1rem 1.3rem; margin: 1.2rem 0; color: #5a4a00; }\n  .sgs-callout p { margin: 0 !important; }\n\n  .sgs-spec-table { width: 100%; border-collapse: collapse; margin-bottom: 1.5rem; }\n  .sgs-spec-table th { background: #0d1a2e; color: #fff !important; text-align: left; padding: 0.7rem 1rem; font-weight: 700; font-size: 16px !important; }\n  .sgs-spec-table td { padding: 0.6rem 1rem; border-bottom: 1px solid #e8e0de; vertical-align: top; font-size: 16px !important; }\n  .sgs-spec-table tr:nth-child(even) td { background: #fdf0ed; }\n  .sgs-spec-table td:first-child { font-weight: 600; color: #111; width: 44%; }\n  .sgs-spec-table .section-head td { background: #e8401c !important; color: #fff !important; font-weight: 700 !important; font-size: 14px !important; text-transform: uppercase; letter-spacing: 0.05em; }\n\n  .sgs-faq-item { border-bottom: 1px solid #e8e0de; padding: 1rem 0; }\n  .sgs-faq-item:last-child { border-bottom: none; }\n  .sgs-faq-item p { margin: 0.4rem 0 0 !important; }\n\n  .sgs-infobox { background: #fdf0ed; border: 1px solid #f5c4b8; border-radius: 6px; padding: 1rem 1.2rem; margin-top: 1.5rem; font-size: 16px !important; line-height: 1.6; }\n\n  @media (max-width: 600px) {\n    .sgs-grid { grid-template-columns: 1fr 1fr; }\n    .sgs-flow-grid { grid-template-columns: repeat(3, 1fr); }\n    .sgs-stat-bar { justify-content: center; }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"sgs-desc\"\u003e\n\u003cdiv class=\"sgs-intro-box\"\u003e\n\u003cp\u003e\u003cspan class=\"sgs-badge\"\u003e100A Single Phase\u003c\/span\u003e\u003cspan class=\"sgs-badge dark\"\u003e0ms Switchover\u003c\/span\u003e\u003cspan class=\"sgs-badge green\"\u003eWhole-Home Backup\u003c\/span\u003e\u003cspan class=\"sgs-badge grey\"\u003eMPN: 11110030\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin-top:0.75rem !important;\"\u003eThe \u003cstrong\u003eSigenergy Sigen Energy Gateway HomePro SP-F\u003c\/strong\u003e is the backup switching and multi-source energy management hub for the SigenStor single-phase home energy system. It is the component that transforms a SigenStor installation from a solar-and-save system into a \u003cstrong\u003efull whole-home power-cut protection system\u003c\/strong\u003e. At 100A nominal current, the HomePro SP-F supports up to 22kW of continuous load — meaning the entire home stays live on battery and solar during a grid outage, with no load-shedding or critical-loads-only compromise. Switchover is \u003cstrong\u003e0ms load-side disruption\u003c\/strong\u003e, so sensitive electronics, NAS drives, routers and alarm systems are unaffected. The F suffix denotes the rear cable entry design, enabling a cleaner, more concealed wall installation compared to earlier models.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sgs-stat-bar\"\u003e\n\u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e100A\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eAC Current\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e22kW\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eBackup Capacity\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e0ms\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eSwitchover Time\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e350ms\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eAnti-Backflow\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003eIP55\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eProtection Rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e6\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eEnergy Sources Managed\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWhat the Gateway Does — Energy Sources Managed\u003c\/h2\u003e\n\u003cp\u003eThe HomePro SP-F acts as the central switching and management hub between all energy sources and your home. It handles six source types seamlessly:\u003c\/p\u003e\n\u003cdiv class=\"sgs-flow-grid\"\u003e\n\u003cdiv class=\"sgs-flow-item\"\u003e\n\u003cspan class=\"icon\"\u003e☀️\u003c\/span\u003e\u003cstrong\u003eSolar PV\u003c\/strong\u003eRoutes surplus PV to battery or grid, and PV to loads during backup\u003c\/div\u003e\n\u003cdiv class=\"sgs-flow-item\"\u003e\n\u003cspan class=\"icon\"\u003e🔋\u003c\/span\u003e\u003cstrong\u003eBattery (ESS)\u003c\/strong\u003eManages discharge to loads and switches to battery-only during outages\u003c\/div\u003e\n\u003cdiv class=\"sgs-flow-item\"\u003e\n\u003cspan class=\"icon\"\u003e⚡\u003c\/span\u003e\u003cstrong\u003eGrid\u003c\/strong\u003eMonitors grid voltage\/frequency; isolates instantly on fault detection\u003c\/div\u003e\n\u003cdiv class=\"sgs-flow-item\"\u003e\n\u003cspan class=\"icon\"\u003e🔌\u003c\/span\u003e\u003cstrong\u003eGenerator\u003c\/strong\u003eIntegrates diesel\/petrol generator via Smart Port with 2-wire auto-start\u003c\/div\u003e\n\u003cdiv class=\"sgs-flow-item\"\u003e\n\u003cspan class=\"icon\"\u003e🚗\u003c\/span\u003e\u003cstrong\u003eV2X \/ EV\u003c\/strong\u003eManages Vehicle-to-Home and Vehicle-to-Grid energy flows via the DC module\u003c\/div\u003e\n\u003cdiv class=\"sgs-flow-item\"\u003e\n\u003cspan class=\"icon\"\u003e🏠\u003c\/span\u003e\u003cstrong\u003eSmart Loads\u003c\/strong\u003eSmart Port controls EV chargers, heat pumps and other deferrable loads by SOC and time schedule\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"sgs-grid\"\u003e\n\u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e⚡ 0ms Load-Side Switchover\u003c\/strong\u003eWhen the grid fails, the HomePro SP-F detects the outage and switches the home to battery\/solar power with zero load-side disruption — before any connected device registers an interruption. This is achieved through Sigenergy's patented power control algorithm operating in coordination with the SigenStor Energy Controller and Battery. Sensitive electronics, smart home devices, and medical equipment remain online uninterrupted.\u003c\/div\u003e\n\u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e🏠 True Whole-Home 100A Backup\u003c\/strong\u003eUnlike gateway models limited to 54.6A (12kW), the HomePro SP-F operates at \u003cstrong\u003e100A \/ 22kW continuous\u003c\/strong\u003e — the full single-phase service capacity for most UK homes. There is no need to segregate critical from non-critical loads or rewire a separate backup sub-panel. Every socket and circuit in the home is protected during a power cut, up to the rating of the SigenStor battery and inverter combination.\u003c\/div\u003e\n\u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e🔁 Built-in Bypass Circuit\u003c\/strong\u003eAn integrated bypass circuit allows the home to remain connected directly to the grid even if the gateway itself requires service or maintenance. This means a gateway fault does not cut off the home from the grid — a key resilience and safety feature for professional installations. The bypass can be activated manually without powering down the system.\u003c\/div\u003e\n\u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e🔌 Generator Integration — Smart Port\u003c\/strong\u003eThe Smart Port (up to 55A \/ 12kW) supports connection of a diesel or petrol generator as an additional backup energy source. 2-wire auto-start is supported, enabling the mySigen app to automatically start and stop the generator based on battery state of charge, time of day, or load demand — no manual intervention required. Generator output is also managed to prevent backfeed onto the grid.\u003c\/div\u003e\n\u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e📡 350ms Anti-Backflow Protection\u003c\/strong\u003eReal-time current monitoring detects reverse power flow (backfeed towards the grid during backup operation) within 350ms and acts to prevent it — protecting the grid, the DNO infrastructure, and any engineers who may be working on the network during an outage. Fully compliant with G98\/G100 anti-islanding and backfeed prevention requirements.\u003c\/div\u003e\n\u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e📱 Smart Load Control via mySigen App\u003c\/strong\u003eThe Smart Port also controls connected smart loads — EV AC chargers, heat pumps, immersion heaters, or any other controllable device. Set loads to run only when battery SOC exceeds a threshold, during solar surplus hours, or during off-peak tariff windows. Remotely control generator start\/stop. All managed from the mySigen app alongside the wider SigenStor system dashboard.\u003c\/div\u003e\n\u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e🔧 Rear Cable Entry (SP-F Design)\u003c\/strong\u003eThe F suffix distinguishes this model from earlier HomePro SP variants by its \u003cstrong\u003erear wire entry\u003c\/strong\u003e design. Cables enter from behind the unit through the wall, keeping the front face and sides completely clear of visible conduit or trunking. Combined with the decorative cover (supplied), the installed unit presents a clean, modern appearance suitable for living areas and utility rooms alike.\u003c\/div\u003e\n\u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e🌡️ IP55 — Indoor \u0026amp; Sheltered Outdoor\u003c\/strong\u003eIP55 ingress protection makes the HomePro SP-F suitable for installation in garages, utility rooms, plant rooms, and sheltered external locations. Natural convection cooling requires no fan maintenance. Operating temperature range: -30°C to 55°C. Wall-mounted only.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eHomePro SP-F vs Standard HomePro SP\u003c\/h2\u003e\n\u003ctable class=\"sgs-compare-table\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eHomePro SP\u003c\/th\u003e\n\u003cth class=\"col-highlight\"\u003eHomePro SP-F (this product)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC current\u003c\/td\u003e\n\u003ctd\u003e54.6A\u003c\/td\u003e\n\u003ctd class=\"col-highlight\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal backup power\u003c\/td\u003e\n\u003ctd\u003e12kW\u003c\/td\u003e\n\u003ctd class=\"col-highlight\"\u003e22kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhole-home backup (100A supply)\u003c\/td\u003e\n\u003ctd\u003eNo — partial loads only\u003c\/td\u003e\n\u003ctd class=\"col-highlight\"\u003eYes — full home\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchover time\u003c\/td\u003e\n\u003ctd\u003e0ms\u003c\/td\u003e\n\u003ctd class=\"col-highlight\"\u003e0ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear cable entry\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd class=\"col-highlight\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBypass circuit\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd class=\"col-highlight\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator Smart Port\u003c\/td\u003e\n\u003ctd\u003eYes (12kW \/ 54.6A)\u003c\/td\u003e\n\u003ctd class=\"col-highlight\"\u003eYes (12kW \/ 55A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter connection current\u003c\/td\u003e\n\u003ctd\u003e54.6A \/ 32A\u003c\/td\u003e\n\u003ctd class=\"col-highlight\"\u003e55A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003ctd class=\"col-highlight\"\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest suited for\u003c\/td\u003e\n\u003ctd\u003eHomes with lower consumption, selective load backup\u003c\/td\u003e\n\u003ctd class=\"col-highlight\"\u003eAll homes — unrestricted whole-home backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"sgs-callout\"\u003e\u003cp\u003e⚠️ \u003cstrong\u003eRequired for backup power:\u003c\/strong\u003e The HomePro SP-F Gateway must be used \u003cstrong\u003etogether with a SigenStor Energy Controller and at least one SigenStor Battery module\u003c\/strong\u003e to achieve the 0ms load-side switchover. The gateway alone does not store or generate energy — it is the switching and management layer. The 0ms performance also requires that the Energy Controller's nominal power exceeds the total backup load at the time of switchover.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"sgs-spec-table\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eProduct Identity\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPN\u003c\/td\u003e\n\u003ctd\u003e11110030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel name\u003c\/td\u003e\n\u003ctd\u003eSigen Gateway HomePro SP-F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSigenergy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eGrid Connection\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid connection type\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC voltage\u003c\/td\u003e\n\u003ctd\u003e220 \/ 230 \/ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC power\u003c\/td\u003e\n\u003ctd\u003e22kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup switch disruption time\u003c\/td\u003e\n\u003ctd\u003e0ms (load-side; requires SigenStor EC + Battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eAC Output to Backup Port\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC voltage\u003c\/td\u003e\n\u003ctd\u003e220 \/ 230 \/ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC current\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC power\u003c\/td\u003e\n\u003ctd\u003e22kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eInverter Connection\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC voltage\u003c\/td\u003e\n\u003ctd\u003e220 \/ 230 \/ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC current\u003c\/td\u003e\n\u003ctd\u003e55A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC power\u003c\/td\u003e\n\u003ctd\u003e12kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eSmart Port (Generator \/ Smart Loads)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator output voltage\u003c\/td\u003e\n\u003ctd\u003e220 \/ 230 \/ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal current\u003c\/td\u003e\n\u003ctd\u003e55A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC power\u003c\/td\u003e\n\u003ctd\u003e12kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator 2-wire auto-start\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eGeneral Data\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e450 × 695 × 177mm (without decorative cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e25kg (without decorative cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operating altitude\u003c\/td\u003e\n\u003ctd\u003e4,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection rating\u003c\/td\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable entry\u003c\/td\u003e\n\u003ctd\u003eRear (concealed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation method\u003c\/td\u003e\n\u003ctd\u003eWall mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eFast Ethernet, RS485, dry contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti-backflow protection response\u003c\/td\u003e\n\u003ctd\u003e350ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cdiv class=\"sgs-faq-item\"\u003e\n\u003ch3\u003eDo I need this gateway if I already have a SigenStor EC and batteries?\u003c\/h3\u003e\n\u003cp\u003eOnly if you want backup power during a grid outage. Without the Gateway, a SigenStor installation operates as a grid-tied solar + storage system — it will charge and discharge normally, save money on bills, and export surplus solar, but it will shut down automatically when the grid fails (as required by G98\/G100 anti-islanding regulations). The Gateway is what enables the system to island safely, switch to battery\/solar, and keep the home powered during a power cut. If backup protection is a requirement, the Gateway is essential.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sgs-faq-item\"\u003e\n\u003ch3\u003eWhat is the difference between the HomePro SP and the HomePro SP-F?\u003c\/h3\u003e\n\u003cp\u003eThe HomePro SP-F is the upgraded, higher-current version. The most significant difference is the AC current rating: \u003cstrong\u003e100A on the SP-F vs 54.6A on the standard SP\u003c\/strong\u003e. This means the SP-F supports the full 22kW capacity of a standard UK 100A single-phase supply — the entire home stays on backup with no load restrictions. The SP-F also features \u003cstrong\u003erear cable entry\u003c\/strong\u003e (the F suffix), providing a cleaner installation aesthetic. Both models offer 0ms switchover, bypass circuits, generator Smart Port, and anti-backflow protection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sgs-faq-item\"\u003e\n\u003ch3\u003eCan I connect a generator and how does auto-start work?\u003c\/h3\u003e\n\u003cp\u003eYes. The Smart Port accepts a generator rated up to 12kW \/ 55A at 220–240V single phase. 2-wire auto-start is supported: connect the gateway's auto-start output to the generator's start terminals, then configure start\/stop rules in the mySigen app — for example, start the generator if battery SOC drops below 15%, stop it when SOC reaches 80%. This keeps the home continuously powered during extended outages without manual intervention. The gateway also prevents the generator from backfeeding the grid.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sgs-faq-item\"\u003e\n\u003ch3\u003eHow many SigenStor inverters can this gateway support?\u003c\/h3\u003e\n\u003cp\u003eThe HomePro SP-F inverter connection supports up to 12kW from the SigenStor Energy Controllers — typically one or two single-phase EC units depending on their rating. For larger multi-inverter installations exceeding this, Sigenergy offers higher-capacity gateway models in the HomePro range. The 100A grid and backup port rating means the gateway itself is not the bottleneck — the limit is the inverter connection port rated at 55A \/ 12kW.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sgs-infobox\"\u003e\n\u003cstrong\u003eℹ️ Required companion products:SigenStor Energy Controller\u003c\/strong\u003e (EC 3.6 SP, EC 6.0 SP, or larger) — must be installed for 0ms switchover ·\u003cstrong\u003eSigenStor Battery Module(s)\u003c\/strong\u003e (BAT 6.0, BAT 8.0, etc.) — provides the backup energy storage ·\u003cstrong\u003eOptional: Sigen CommMod\u003c\/strong\u003e — adds 4G connectivity for remote monitoring and app control without home Wi-Fi\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sigenergy","offers":[{"title":"Default Title","offer_id":63580873752925,"sku":"SIG-11110030","price":995.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SigenEnergyGatewayHomeProSP-F.jpg?v=1772097616"},{"product_id":"sigenergy-sigen-power-sensor-three-phase-external-ct-120a-din-rail-rs485-solar-import-export-monitoring","title":"Sigenergy Sigen Power Sensor | Three Phase External CT 120A | DIN Rail | RS485 | Solar Import\/Export Monitoring","description":"\u003cstyle\u003e\n  .sgs-desc * { box-sizing: border-box; }\n  .sgs-desc { font-family: inherit; color: inherit; line-height: 1.7; font-size: 16px; }\n  .sgs-desc p, .sgs-desc li, .sgs-desc td, .sgs-desc th { font-size: 16px !important; line-height: 1.7; }\n  .sgs-desc h2 { font-size: 22px !important; font-weight: 700; color: #0d1a2e; border-bottom: 2px solid #e8401c; padding-bottom: 6px; margin: 2rem 0 1rem; line-height: 1.3; }\n  .sgs-desc h3 { font-size: 17px !important; font-weight: 700; color: #0d1a2e; margin: 1.2rem 0 0.4rem; line-height: 1.4; }\n  .sgs-desc p { margin: 0 0 1rem; }\n  .sgs-desc ul { padding-left: 1.5rem; margin: 0 0 1rem; }\n  .sgs-desc ul li { margin-bottom: 0.5rem; }\n\n  .sgs-intro-box { background: #fdf0ed; border-left: 4px solid #e8401c; padding: 1.1rem 1.4rem; border-radius: 0 6px 6px 0; margin-bottom: 1.5rem; }\n  .sgs-intro-box p { margin: 0 !important; }\n\n  .sgs-badge { display: inline-block; background: #e8401c; color: #fff; font-size: 13px !important; font-weight: 700; border-radius: 4px; padding: 2px 10px; margin-right: 6px; margin-bottom: 4px; vertical-align: middle; }\n  .sgs-badge.dark { background: #0d1a2e; }\n  .sgs-badge.grey { background: #555; }\n  .sgs-badge.green { background: #1a7a3c; }\n\n  .sgs-stat-bar { background: #0d1a2e; color: #fff; border-radius: 8px; padding: 1.1rem 1.4rem; margin: 1.2rem 0; display: flex; flex-wrap: wrap; gap: 1.5rem; align-items: center; justify-content: space-around; }\n  .sgs-stat { text-align: center; }\n  .sgs-stat .num { font-size: 26px !important; font-weight: 800; color: #ff7a5a; line-height: 1; }\n  .sgs-stat .lbl { font-size: 12px !important; color: #aab; margin-top: 2px; }\n\n  .sgs-grid { display: grid; grid-template-columns: repeat(auto-fill, minmax(230px, 1fr)); gap: 0.85rem; margin-bottom: 1.2rem; }\n  .sgs-card { background: #fdf0ed; border: 1px solid #f5c4b8; border-radius: 6px; padding: 1rem 1.1rem; line-height: 1.6; }\n  .sgs-card strong { display: block; color: #0d1a2e; margin-bottom: 0.35rem; font-size: 16px !important; }\n\n  .sgs-enables-list { list-style: none !important; padding: 0 !important; margin: 0 0 1rem !important; display: grid; grid-template-columns: repeat(auto-fill, minmax(260px, 1fr)); gap: 0.5rem; }\n  .sgs-enables-list li { background: #fdf0ed; border: 1px solid #f5c4b8; border-radius: 5px; padding: 0.55rem 1rem 0.55rem 2.2rem !important; position: relative; font-size: 15px !important; margin: 0 !important; line-height: 1.55; }\n  .sgs-enables-list li::before { content: \"✓\"; position: absolute; left: 0.7rem; color: #e8401c; font-weight: 700; }\n  .sgs-enables-list li.req::before { content: \"✗\"; color: #888; }\n\n  .sgs-variant-table { width: 100%; border-collapse: collapse; margin-bottom: 1.2rem; }\n  .sgs-variant-table th { background: #0d1a2e; color: #fff !important; padding: 0.65rem 0.9rem; font-size: 15px !important; text-align: left; }\n  .sgs-variant-table th:not(:first-child) { text-align: center; }\n  .sgs-variant-table td { padding: 0.55rem 0.9rem; border-bottom: 1px solid #e8e0de; font-size: 15px !important; }\n  .sgs-variant-table td:not(:first-child) { text-align: center; }\n  .sgs-variant-table tr:nth-child(even) td { background: #fdf0ed; }\n  .sgs-variant-table td:first-child { font-weight: 600; color: #111; }\n  .sgs-variant-table .col-highlight { font-weight: 700; color: #e8401c !important; background: #fdf0ed; }\n\n  .sgs-callout { background: #fff8e6; border: 1px solid #f0d080; border-radius: 6px; padding: 1rem 1.3rem; margin: 1.2rem 0; color: #5a4a00; }\n  .sgs-callout p { margin: 0 !important; }\n\n  .sgs-spec-table { width: 100%; border-collapse: collapse; margin-bottom: 1.5rem; }\n  .sgs-spec-table th { background: #0d1a2e; color: #fff !important; text-align: left; padding: 0.7rem 1rem; font-weight: 700; font-size: 16px !important; }\n  .sgs-spec-table td { padding: 0.6rem 1rem; border-bottom: 1px solid #e8e0de; vertical-align: top; font-size: 16px !important; }\n  .sgs-spec-table tr:nth-child(even) td { background: #fdf0ed; }\n  .sgs-spec-table td:first-child { font-weight: 600; color: #111; width: 44%; }\n  .sgs-spec-table .section-head td { background: #e8401c !important; color: #fff !important; font-weight: 700 !important; font-size: 14px !important; text-transform: uppercase; letter-spacing: 0.05em; }\n\n  .sgs-faq-item { border-bottom: 1px solid #e8e0de; padding: 1rem 0; }\n  .sgs-faq-item:last-child { border-bottom: none; }\n  .sgs-faq-item p { margin: 0.4rem 0 0 !important; }\n\n  .sgs-infobox { background: #fdf0ed; border: 1px solid #f5c4b8; border-radius: 6px; padding: 1rem 1.2rem; margin-top: 1.5rem; font-size: 16px !important; line-height: 1.6; }\n\n  @media (max-width: 600px) {\n    .sgs-grid { grid-template-columns: 1fr 1fr; }\n    .sgs-stat-bar { justify-content: center; }\n    .sgs-enables-list { grid-template-columns: 1fr; }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"sgs-desc\"\u003e\n\n  \u003cdiv class=\"sgs-intro-box\"\u003e\n    \u003cp\u003e\n      \u003cspan class=\"sgs-badge\"\u003eThree Phase\u003c\/span\u003e\n      \u003cspan class=\"sgs-badge dark\"\u003e3 × 120A CT Included\u003c\/span\u003e\n      \u003cspan class=\"sgs-badge green\"\u003e±1% Accuracy\u003c\/span\u003e\n      \u003cspan class=\"sgs-badge grey\"\u003ePart No: SIG-SENSOR-TP-CT-DH\u003c\/span\u003e\n    \u003c\/p\u003e\n    \u003cp style=\"margin-top:0.75rem !important;\"\u003eThe \u003cstrong\u003eSigenergy Power Sensor TP-CT-DH\u003c\/strong\u003e is a three-phase energy metering device that connects via RS485 to Sigenergy inverters, energy controllers and the SigenStor system — providing real-time, high-accuracy measurement of grid import and export across all three phases. It is the essential component that enables the SigenStor EMS to make intelligent, load-aware decisions: without it, the system cannot see what the home is consuming or exporting, so advanced functions including dynamic load management, solar surplus EV charging, and export limitation are unavailable. Three external 120A split-core current transformers (CTs) are included in the box, making this a complete, ready-to-install metering solution for three-phase residential and light commercial supplies.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"sgs-stat-bar\"\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e3-Phase\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003e3P3W \/ 3P4W\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e120A\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eCT Rating\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e±1%\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003ePower Accuracy\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e100ms\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eData Refresh\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003eRS485\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eInterface\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003eIP51\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eProtection Rating\u003c\/div\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eWhat the Power Sensor Enables\u003c\/h2\u003e\n  \u003cp\u003eThe Power Sensor sits at the grid connection point (typically in or adjacent to the consumer unit) and feeds real-time import\/export data to the SigenStor Energy Controller via RS485. This measurement is the foundation for a wide range of intelligent energy management functions:\u003c\/p\u003e\n  \u003cul class=\"sgs-enables-list\"\u003e\n    \u003cli\u003eDynamic load management — prevents main fuse overload by throttling inverter\/charger output in real time\u003c\/li\u003e\n    \u003cli\u003eSolar surplus EV charging (Solar Boost, 100% PV modes) via the Sigen EV AC Charger\u003c\/li\u003e\n    \u003cli\u003eExport limitation — caps grid export to a set threshold (e.g. 0W or 3.68kW) for DNO compliance\u003c\/li\u003e\n    \u003cli\u003eImport limitation — prevents grid draw above a set threshold for demand management\u003c\/li\u003e\n    \u003cli\u003eSelf-consumption optimisation — tells the EMS when to charge battery vs export surplus\u003c\/li\u003e\n    \u003cli\u003eAI tariff scheduling — real-time consumption data feeds the mySigen AI energy optimiser\u003c\/li\u003e\n    \u003cli\u003eAccurate energy flow display in the mySigen app — grid import\/export, household load, solar generation\u003c\/li\u003e\n    \u003cli\u003eAnti-backflow protection when used with the Sigen Energy Gateway\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cdiv class=\"sgs-callout\"\u003e\n    \u003cp\u003e⚠️ \u003cstrong\u003eRequired for key functions:\u003c\/strong\u003e Dynamic load management and all solar-priority EV charging modes (Solar Boost, 100% PV, PV Storage \u0026amp; Charging) on the Sigen EV AC Charger \u003cstrong\u003erequire a Power Sensor to be installed\u003c\/strong\u003e. Without it, the inverter\/controller has no visibility of household consumption and cannot prevent overload or optimise EV charging against solar surplus. Export limitation for DNO\/G98 compliance also requires the Power Sensor.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eKey Features\u003c\/h2\u003e\n  \u003cdiv class=\"sgs-grid\"\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e📡 Three External Split-Core CTs Included\u003c\/strong\u003eThree split-core current transformers (CTs) are supplied in the box — one per phase. Split-core design means the CT can be clipped around the existing live conductor without disconnecting or stripping any wiring. Each CT is rated to 120A with a 16mm inner bore, accommodating standard residential and light commercial cable sizes up to approximately 25–35mm². CT cable length: 1 metre each.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e⚡ 100ms Data Refresh — Instantaneous Response\u003c\/strong\u003eMeasurements are updated every 100 milliseconds and transmitted to the Energy Controller via RS485 (Modbus RTU, 9600 baud). This rapid update rate ensures the EMS can react to sudden load changes — such as a cooker switching on or an EV charger ramping up — fast enough to prevent overload or unnecessary grid draw before the next billing interval.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e🎯 ±1% Power Accuracy — Revenue Grade\u003c\/strong\u003eVoltage accuracy 0.5%, current accuracy 0.5%, power accuracy 1%, frequency accuracy 0.2%. This accuracy class is sufficient for export metering, demand management, and SEG export tracking, and meets the measurement precision required by DNOs for export limitation schemes and smart export guarantee compliance.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e📺 LCD Real-Time Display\u003c\/strong\u003eAn integrated LCD screen shows live readings directly on the unit — useful for commissioning checks, fault-finding, and routine inspection without needing to open the mySigen app. Displays voltage, current, power and frequency per phase, giving installers an instant at-a-glance view of grid conditions at the metering point.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e🔌 Plug-and-Play with Sigenergy Devices\u003c\/strong\u003eConnects via the RS485 port on the Energy Controller or SigenStor system. No configuration or pairing procedure is needed beyond the standard Sigenergy system commissioning process — the controller automatically recognises the sensor on the RS485 bus. Compatible with all Sigen Energy Controller, Hybrid Inverter, and Energy Gateway products.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e📐 DIN Rail Mounting — Consumer Unit Ready\u003c\/strong\u003e35mm DIN rail mounting (standard across UK consumer units and distribution boards) makes installation straightforward in any domestic or light commercial enclosure. Compact dimensions of 72 × 94.5 × 65mm occupy only two or three DIN module spaces. Weight: 200g (sensor body) + 270g (3 × CTs).\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eChoosing the Right CT Rating\u003c\/h2\u003e\n  \u003cp\u003eThe Power Sensor is available in three CT ratings. Select based on the maximum current expected at the grid connection point, which is typically the DNO fuse \/ main incomer rating:\u003c\/p\u003e\n  \u003ctable class=\"sgs-variant-table\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth\u003ePart No\u003c\/th\u003e\n        \u003cth\u003eCT Rating\u003c\/th\u003e\n        \u003cth\u003eCT Bore\u003c\/th\u003e\n        \u003cth class=\"col-highlight\"\u003eTypical Application\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd class=\"col-highlight\"\u003eSIG-SENSOR-TP-CT-DH ★ (this product)\u003c\/td\u003e\n        \u003ctd\u003e120A\u003c\/td\u003e\n        \u003ctd\u003e16mm\u003c\/td\u003e\n        \u003ctd\u003eThree-phase homes and small commercial — up to ~83kVA per phase \/ 120A service\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eSIG-SENSOR-TP-CT300-DH\u003c\/td\u003e\n        \u003ctd\u003e300A\u003c\/td\u003e\n        \u003ctd\u003elarger\u003c\/td\u003e\n        \u003ctd\u003eLarger commercial premises — up to 300A three-phase supply\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eSIG-SENSOR-TP-CT600-DH\u003c\/td\u003e\n        \u003ctd\u003e600A\u003c\/td\u003e\n        \u003ctd\u003e36mm\u003c\/td\u003e\n        \u003ctd\u003eIndustrial \/ large commercial — up to 600A three-phase supply\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n  \u003cp style=\"font-size:14px !important; color:#666;\"\u003eFor single-phase supplies, see the equivalent single-phase variants: \u003cstrong\u003eSIG-SENSOR-SP-DH\u003c\/strong\u003e (direct connection, up to 100A) and \u003cstrong\u003eSIG-SENSOR-SP-CT-DH\u003c\/strong\u003e (with external 120A CT).\u003c\/p\u003e\n\n  \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable class=\"sgs-spec-table\"\u003e\n    \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eProduct Identity\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003ePart No\u003c\/td\u003e\n\u003ctd\u003eSIG-SENSOR-TP-CT-DH\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eDatasheet model designation\u003c\/td\u003e\n\u003ctd\u003eTP-CT120-DH\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSigenergy\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003ePower Supply \u0026amp; Grid Connection\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eGrid connection type\u003c\/td\u003e\n\u003ctd\u003e3P3W \/ 3P4W (three-phase three-wire \/ four-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eAC input voltage range\u003c\/td\u003e\n\u003ctd\u003e173–480 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eNominal AC frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eMeasurement Accuracy\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eVoltage accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCurrent accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003ePower accuracy\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eFrequency accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eData refresh rate\u003c\/td\u003e\n\u003ctd\u003e100ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eCommunication\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eBaud rate\u003c\/td\u003e\n\u003ctd\u003e9,600 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eGeneral Data — Sensor Body\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e72 × 94.5 × 65mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e200g\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD (real-time voltage, current, power, frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eInstallation method\u003c\/td\u003e\n\u003ctd\u003eDIN Rail 35mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eIngress protection rating\u003c\/td\u003e\n\u003ctd\u003eIP51\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e0–90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eCT Accessories (× 3 supplied)\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eNumber of CTs supplied\u003c\/td\u003e\n\u003ctd\u003e3 (one per phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCT type\u003c\/td\u003e\n\u003ctd\u003eSplit-core (clip-on, no disconnection required)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMax. operating current per CT\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCT inner bore diameter\u003c\/td\u003e\n\u003ctd\u003e16mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCT cable length\u003c\/td\u003e\n\u003ctd\u003e1 metre\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eWeight per CT\u003c\/td\u003e\n\u003ctd\u003e90g\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eStandards\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eStandard compliance\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1:2010, EN 61010-2-030:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003ch2\u003eFAQs\u003c\/h2\u003e\n  \u003cdiv class=\"sgs-faq-item\"\u003e\n    \u003ch3\u003eIs a Power Sensor always required with a SigenStor system?\u003c\/h3\u003e\n    \u003cp\u003eNot strictly — the SigenStor will operate for basic solar self-consumption and tariff-scheduled charging without a Power Sensor, using the inverter's own output measurement and a fixed schedule. However, it is \u003cstrong\u003erequired\u003c\/strong\u003e for dynamic load management (preventing fuse overloads), all solar surplus EV charging modes, export limitation for DNO compliance, and for the mySigen app to display accurate household consumption figures. In practice, the Power Sensor is considered essential for any well-functioning installation and most professional installers include it as standard.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"sgs-faq-item\"\u003e\n    \u003ch3\u003eWhere are the CTs installed?\u003c\/h3\u003e\n    \u003cp\u003eThe three CTs are clipped around the incoming live conductors at the grid connection point — typically on the tails between the DNO cutout fuse and the main consumer unit, or on the main incomer cables inside a distribution board. They must be positioned to measure total import\/export across all three phases, on the grid side of the system (before the inverter connection). The 1m CT cables connect back to the sensor body, which mounts on the DIN rail in the consumer unit or an adjacent enclosure.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"sgs-faq-item\"\u003e\n    \u003ch3\u003eDo I need the CT120 or a higher-rated CT variant?\u003c\/h3\u003e\n    \u003cp\u003eFor most UK three-phase residential and small commercial installations, the 120A CT (this product) is appropriate. A typical UK three-phase residential supply is 100A per phase — well within the 120A CT rating. If your supply is larger (e.g. a commercial premises with a 200A or 300A three-phase incomer), choose the CT300 or CT600 variant accordingly. If in doubt, check the rating of the DNO fuse or main incomer breaker on each phase.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"sgs-infobox\"\u003e\n    \u003cstrong\u003eℹ️ Often purchased with:\u003c\/strong\u003e\n    \u003cstrong\u003eSigenStor EC 6.0 SP or larger\u003c\/strong\u003e — three-phase Power Sensor matches three-phase or larger single-phase installs ·\n    \u003cstrong\u003eSigen EV AC Charger 7kW\u003c\/strong\u003e — Power Sensor is required for all solar charging modes on the EV charger ·\n    \u003cstrong\u003eSigen Energy Gateway HomePro SP-F\u003c\/strong\u003e — works with Power Sensor for real-time anti-backflow and load monitoring ·\n    \u003cstrong\u003eSIG-SENSOR-TP-CT300-DH\u003c\/strong\u003e — if CT120 is insufficient for your supply current\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Sigenergy","offers":[{"title":"Default Title","offer_id":63581116989789,"sku":"SIG-SENSOR-TP-CT-DH","price":220.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SigenergyPowerSensorThreePhaseExternalCTDH.jpg?v=1771914600"},{"product_id":"sigenergy-sigen-power-sensor-three-phase-external-ct-300a-din-rail-rs485-solar-import-export-monitoring","title":"Sigenergy 3-Phase Smart Meter with 300A CTs | TP-CT300 | RS48","description":"\u003c!-- SEO Product Name: Sigenergy 3-Phase Smart Meter with 300A CTs | TP-CT300 | RS485 --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; color:#1f2933; line-height:1.6;\"\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eSigenergy Sigen Sensor TP-CT300\u003c\/strong\u003e is a \u003cstrong\u003ethree phase smart power sensor\u003c\/strong\u003e that measures \u003cstrong\u003egrid import and export\u003c\/strong\u003e at the point of connection, so your Sigenergy system always knows what the site is drawing from or sending to the grid. It uses \u003cstrong\u003eindirect measurement\u003c\/strong\u003e through \u003cstrong\u003ethree external 300 A current transformers (included)\u003c\/strong\u003e, and reports back over \u003cstrong\u003eRS485 using Modbus RTU\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eWith support for \u003cstrong\u003e3P3W and 3P4W\u003c\/strong\u003e supplies and CTs rated to \u003cstrong\u003e300 A per phase\u003c\/strong\u003e, it suits \u003cstrong\u003elarger three-phase homes and commercial sites\u003c\/strong\u003e running \u003cstrong\u003eSigenStor\u003c\/strong\u003e systems. The compact \u003cstrong\u003e19 mm wide DIN rail\u003c\/strong\u003e housing mounts neatly inside the distribution board or a dedicated enclosure.\u003c\/p\u003e\n\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:10px; margin:20px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e3-Phase\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003e3P3W \/ 3P4W supplies\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e3 x 300 A\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eCTs included, 24 mm inner diameter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eRS485\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eModbus RTU, 9,600 bps\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e1%\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003ePower measurement accuracy\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e19 mm\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eCompact DIN rail housing\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eIP20\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003e-25 to 65 °C operating range\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FDECEA; border-left:5px solid #C62828; border-radius:6px; padding:14px 16px; margin:14px 0;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#C62828; margin-bottom:4px;\"\u003eInstallation Safety\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933;\"\u003eInstallation must be carried out by a \u003cstrong\u003ecompetent, qualified electrician\u003c\/strong\u003e in line with \u003cstrong\u003eBS 7671\u003c\/strong\u003e and Sigenergy's installation guide. Isolate the supply before working on the meter or fitting the CTs, and follow the manufacturer's instructions for CT orientation, phase matching and wiring.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFF4E0; border-left:5px solid #E69100; border-radius:6px; padding:14px 16px; margin:14px 0;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#E69100; margin-bottom:4px;\"\u003eCompatibility and Model Selection\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933;\"\u003eThis is the \u003cstrong\u003eTP-CT300\u003c\/strong\u003e with \u003cstrong\u003e300 A CTs\u003c\/strong\u003e for \u003cstrong\u003ethree phase\u003c\/strong\u003e supplies. Choose the CT rating to suit the incoming supply per phase, and note that the \u003cstrong\u003eTP-CT300-DH\u003c\/strong\u003e is a different Sigenergy model. Always check your Sigenergy inverter or SigenStor model supports this sensor before ordering.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E6F2F1; border-left:5px solid #008377CF; border-radius:6px; padding:14px 16px; margin:14px 0;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:4px;\"\u003eWhat Is in the Box\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933;\"\u003e\n\u003cstrong\u003e1 x Sigen Sensor TP-CT300 meter\u003c\/strong\u003e and \u003cstrong\u003e3 x 300 A current transformers\u003c\/strong\u003e with 1 m cables, so no separate CT purchase is needed.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"font-size:20px; font-weight:700; color:#008377CF; margin:26px 0 10px 0;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:12px; margin-bottom:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:8px; padding:14px 16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eThree Phase Import and Export Metering\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933; font-size:15px;\"\u003eMeasures \u003cstrong\u003epower flowing to and from the grid\u003c\/strong\u003e across all three phases, giving the system the data it needs to balance solar, battery and site load.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:8px; padding:14px 16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003e1% Power Accuracy\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933; font-size:15px;\"\u003e\n\u003cstrong\u003e0.5% voltage accuracy\u003c\/strong\u003e, \u003cstrong\u003e0.5% current accuracy\u003c\/strong\u003e (12 to 300 A) and \u003cstrong\u003e1% power accuracy\u003c\/strong\u003e for dependable control and reporting.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:8px; padding:14px 16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eThree Included 300 A CTs\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933; font-size:15px;\"\u003e\n\u003cstrong\u003eThree external CTs rated to 300 A\u003c\/strong\u003e each, with a \u003cstrong\u003e24 mm inner diameter\u003c\/strong\u003e and \u003cstrong\u003e1 m lead\u003c\/strong\u003e, supplied in the box.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:8px; padding:14px 16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eRS485 Modbus RTU\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933; font-size:15px;\"\u003eIndustry-standard \u003cstrong\u003eRS485 communication\u003c\/strong\u003e at \u003cstrong\u003e9,600 bps\u003c\/strong\u003e for a reliable, wired link to Sigenergy equipment.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:8px; padding:14px 16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eCompact DIN Rail Mount\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933; font-size:15px;\"\u003eJust \u003cstrong\u003e19 mm wide\u003c\/strong\u003e and \u003cstrong\u003e35 mm DIN rail\u003c\/strong\u003e mounted, with a meter weight of only \u003cstrong\u003e0.08 kg\u003c\/strong\u003e, so it takes minimal space in the enclosure.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:8px; padding:14px 16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eWide Voltage and Temperature Range\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933; font-size:15px;\"\u003eAccepts \u003cstrong\u003e90 to 277 Vac (L-N)\u003c\/strong\u003e and \u003cstrong\u003e156 to 480 Vac (L-L)\u003c\/strong\u003e at \u003cstrong\u003e50 \/ 60 Hz\u003c\/strong\u003e, operating from \u003cstrong\u003e-25 to 65 °C\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"font-size:20px; font-weight:700; color:#008377CF; margin:26px 0 4px 0;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:8px; overflow:hidden; margin:12px 0 24px 0;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px;\"\u003eGeneral\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eManufacturer\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003eSigenergy\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eModel \/ MPN\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003eSigen Sensor TP-CT300\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eGrid connection type\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e3P3W \/ 3P4W (three phase, three or four wire)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eMeasurement type\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003eIndirect, via external CTs\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eMounting\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e35 mm DIN rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eIngress protection\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003eIP20 (indoor, inside an enclosure or distribution board)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px;\"\u003eElectrical and Measurement\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eAC input voltage range\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e90 to 277 Vac (L-N), 156 to 480 Vac (L-L)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eNominal frequency\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e50 \/ 60 Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eVoltage accuracy\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e0.5%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eCurrent accuracy\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e0.5% (12 to 300 A)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003ePower accuracy\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e1%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eFrequency accuracy\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e0.2%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px;\"\u003eCommunication\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eInterface\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003eRS485\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eProtocol\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003eModbus RTU\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eBaud rate\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e9,600 bps\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px;\"\u003eCurrent Transformers (Included)\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eNumber of CTs\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eRated current per CT\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e300 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eCT inner diameter\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e24 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eCT cable length\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e1 m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eCT set weight\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e1.06 kg (3 CTs)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px;\"\u003ePhysical and Environmental\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eDimensions (W x H x D)\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e19 x 94.5 x 68.5 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eMeter weight\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e0.08 kg\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eOperating temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e-25 to 65 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eStorage temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e-40 to 70 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eRelative humidity\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e0% to 95%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eStandards\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003eEN 61010-1:2010, EN 61010-2-030:2010\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"font-size:20px; font-weight:700; color:#008377CF; margin:26px 0 10px 0;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:11px 14px; cursor:pointer;\"\u003eAre the current transformers included?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; color:#1f2933;\"\u003eYes. The kit includes \u003cstrong\u003ethree 300 A CTs\u003c\/strong\u003e, one per phase, each with a 1 m cable and a 24 mm inner diameter. You do not need to buy CTs separately.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:11px 14px; cursor:pointer;\"\u003eIs this meter suitable for a single phase supply?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; color:#1f2933;\"\u003eNo. The TP-CT300 is a \u003cstrong\u003ethree phase (3P3W \/ 3P4W)\u003c\/strong\u003e sensor. For single phase properties you need a single phase Sigen power sensor.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:11px 14px; cursor:pointer;\"\u003eWhat size of supply is this sensor intended for?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; color:#1f2933;\"\u003eThe included CTs are rated to \u003cstrong\u003e300 A per phase\u003c\/strong\u003e, with \u003cstrong\u003e0.5% current accuracy across 12 to 300 A\u003c\/strong\u003e. Select the CT rating to suit the incoming supply for your site.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:11px 14px; cursor:pointer;\"\u003eWhat does the meter connect to?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; color:#1f2933;\"\u003eIt communicates over \u003cstrong\u003eRS485 (Modbus RTU)\u003c\/strong\u003e and is designed for use with \u003cstrong\u003eSigenergy SigenStor\u003c\/strong\u003e systems as the grid-side meter. Check compatibility of your specific inverter or storage model with Sigenergy before ordering.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:11px 14px; cursor:pointer;\"\u003eHow is the TP-CT300 mounted?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; color:#1f2933;\"\u003eIt clips onto \u003cstrong\u003e35 mm DIN rail\u003c\/strong\u003e. At 19 mm wide and IP20 rated, it should be installed inside a suitable enclosure or distribution board by a qualified electrician.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:11px 14px; cursor:pointer;\"\u003eDoes the TP-CT300 need an installer?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; color:#1f2933;\"\u003eYes. Wiring it into the supply and fitting the CTs must be done by a \u003cstrong\u003ecompetent person\u003c\/strong\u003e in accordance with \u003cstrong\u003eBS 7671\u003c\/strong\u003e and the manufacturer's instructions.\u003c\/div\u003e\u003c\/details\u003e\n\n\u003c\/div\u003e","brand":"Sigenergy","offers":[{"title":"Default Title","offer_id":63581174071645,"sku":"14370007","price":270.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Sigenergy3-PhaseSmartMeterwith300ACTTP-CT300.jpg?v=1792491799"},{"product_id":"sigenergy-sigen-power-sensor-three-phase-external-ct-600a-din-rail-rs485-industrial-import-export-monitoring","title":"Sigenergy Sigen Power Sensor | Three Phase External CT 600A | DIN Rail | RS485 | Industrial Import\/Export Monitoring","description":"\u003cstyle\u003e\n  .sgs-desc * { box-sizing: border-box; }\n  .sgs-desc { font-family: inherit; color: inherit; line-height: 1.7; font-size: 16px; }\n  .sgs-desc p, .sgs-desc li, .sgs-desc td, .sgs-desc th { font-size: 16px !important; line-height: 1.7; }\n  .sgs-desc h2 { font-size: 22px !important; font-weight: 700; color: #0d1a2e; border-bottom: 2px solid #e8401c; padding-bottom: 6px; margin: 2rem 0 1rem; line-height: 1.3; }\n  .sgs-desc h3 { font-size: 17px !important; font-weight: 700; color: #0d1a2e; margin: 1.2rem 0 0.4rem; line-height: 1.4; }\n  .sgs-desc p { margin: 0 0 1rem; }\n  .sgs-desc ul { padding-left: 1.5rem; margin: 0 0 1rem; }\n  .sgs-desc ul li { margin-bottom: 0.5rem; }\n\n  .sgs-intro-box { background: #fdf0ed; border-left: 4px solid #e8401c; padding: 1.1rem 1.4rem; border-radius: 0 6px 6px 0; margin-bottom: 1.5rem; }\n  .sgs-intro-box p { margin: 0 !important; }\n\n  .sgs-badge { display: inline-block; background: #e8401c; color: #fff; font-size: 13px !important; font-weight: 700; border-radius: 4px; padding: 2px 10px; margin-right: 6px; margin-bottom: 4px; vertical-align: middle; }\n  .sgs-badge.dark { background: #0d1a2e; }\n  .sgs-badge.grey { background: #555; }\n  .sgs-badge.green { background: #1a7a3c; }\n  .sgs-badge.blue { background: #1a4a7a; }\n  .sgs-badge.purple { background: #5a1a7a; }\n\n  .sgs-stat-bar { background: #0d1a2e; color: #fff; border-radius: 8px; padding: 1.1rem 1.4rem; margin: 1.2rem 0; display: flex; flex-wrap: wrap; gap: 1.5rem; align-items: center; justify-content: space-around; }\n  .sgs-stat { text-align: center; }\n  .sgs-stat .num { font-size: 26px !important; font-weight: 800; color: #ff7a5a; line-height: 1; }\n  .sgs-stat .lbl { font-size: 12px !important; color: #aab; margin-top: 2px; }\n\n  .sgs-grid { display: grid; grid-template-columns: repeat(auto-fill, minmax(230px, 1fr)); gap: 0.85rem; margin-bottom: 1.2rem; }\n  .sgs-card { background: #fdf0ed; border: 1px solid #f5c4b8; border-radius: 6px; padding: 1rem 1.1rem; line-height: 1.6; }\n  .sgs-card strong { display: block; color: #0d1a2e; margin-bottom: 0.35rem; font-size: 16px !important; }\n\n  .sgs-enables-list { list-style: none !important; padding: 0 !important; margin: 0 0 1rem !important; display: grid; grid-template-columns: repeat(auto-fill, minmax(260px, 1fr)); gap: 0.5rem; }\n  .sgs-enables-list li { background: #fdf0ed; border: 1px solid #f5c4b8; border-radius: 5px; padding: 0.55rem 1rem 0.55rem 2.2rem !important; position: relative; font-size: 15px !important; margin: 0 !important; line-height: 1.55; }\n  .sgs-enables-list li::before { content: \"✓\"; position: absolute; left: 0.7rem; color: #e8401c; font-weight: 700; }\n\n  .sgs-variant-table { width: 100%; border-collapse: collapse; margin-bottom: 1.2rem; }\n  .sgs-variant-table th { background: #0d1a2e; color: #fff !important; padding: 0.65rem 0.9rem; font-size: 14px !important; text-align: left; }\n  .sgs-variant-table th:not(:first-child) { text-align: center; }\n  .sgs-variant-table td { padding: 0.55rem 0.9rem; border-bottom: 1px solid #e8e0de; font-size: 14px !important; }\n  .sgs-variant-table td:not(:first-child) { text-align: center; }\n  .sgs-variant-table tr:nth-child(even) td { background: #fdf0ed; }\n  .sgs-variant-table td:first-child { font-weight: 600; color: #111; }\n  .sgs-variant-table .col-highlight td:first-child { color: #e8401c !important; font-weight: 700; }\n\n  .sgs-callout { background: #fff8e6; border: 1px solid #f0d080; border-radius: 6px; padding: 1rem 1.3rem; margin: 1.2rem 0; color: #5a4a00; }\n  .sgs-callout p { margin: 0 !important; }\n\n  .sgs-spec-table { width: 100%; border-collapse: collapse; margin-bottom: 1.5rem; }\n  .sgs-spec-table th { background: #0d1a2e; color: #fff !important; text-align: left; padding: 0.7rem 1rem; font-weight: 700; font-size: 16px !important; }\n  .sgs-spec-table td { padding: 0.6rem 1rem; border-bottom: 1px solid #e8e0de; vertical-align: top; font-size: 16px !important; }\n  .sgs-spec-table tr:nth-child(even) td { background: #fdf0ed; }\n  .sgs-spec-table td:first-child { font-weight: 600; color: #111; width: 44%; }\n  .sgs-spec-table .section-head td { background: #e8401c !important; color: #fff !important; font-weight: 700 !important; font-size: 14px !important; text-transform: uppercase; letter-spacing: 0.05em; }\n\n  .sgs-faq-item { border-bottom: 1px solid #e8e0de; padding: 1rem 0; }\n  .sgs-faq-item:last-child { border-bottom: none; }\n  .sgs-faq-item p { margin: 0.4rem 0 0 !important; }\n\n  .sgs-infobox { background: #fdf0ed; border: 1px solid #f5c4b8; border-radius: 6px; padding: 1rem 1.2rem; margin-top: 1.5rem; font-size: 16px !important; line-height: 1.6; }\n\n  @media (max-width: 600px) {\n    .sgs-grid { grid-template-columns: 1fr 1fr; }\n    .sgs-stat-bar { justify-content: center; }\n    .sgs-enables-list { grid-template-columns: 1fr; }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"sgs-desc\"\u003e\n\n  \u003cdiv class=\"sgs-intro-box\"\u003e\n    \u003cp\u003e\n      \u003cspan class=\"sgs-badge\"\u003eThree Phase\u003c\/span\u003e\n      \u003cspan class=\"sgs-badge dark\"\u003e3 × 600A CT Included\u003c\/span\u003e\n      \u003cspan class=\"sgs-badge green\"\u003e±1% Accuracy\u003c\/span\u003e\n      \u003cspan class=\"sgs-badge blue\"\u003eIndustrial Scale\u003c\/span\u003e\n      \u003cspan class=\"sgs-badge grey\"\u003ePart No: SIG-SENSOR-TP-CT600-DH\u003c\/span\u003e\n    \u003c\/p\u003e\n    \u003cp style=\"margin-top:0.75rem !important;\"\u003eThe \u003cstrong\u003eSigenergy Power Sensor TP-CT600-DH\u003c\/strong\u003e is the highest-capacity variant in the Sigen Power Sensor range — a three-phase energy metering device for large commercial and industrial installations where the incoming three-phase supply is rated above 300A per phase. Three external split-core current transformers rated to \u003cstrong\u003e600A per phase\u003c\/strong\u003e, with a 36mm inner bore diameter to accommodate large-section busbars and cables, are included in the box. The sensor connects via RS485 Modbus RTU to Sigenergy inverters, energy controllers and the SigenStor EMS, delivering real-time, high-accuracy monitoring of grid import and export across all three phases — enabling the full suite of Sigenergy intelligent energy management functions at industrial scale.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"sgs-stat-bar\"\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e3-Phase\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003e3P3W \/ 3P4W\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e600A\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eCT Rating\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e36mm\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eCT Bore\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e±1%\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003ePower Accuracy\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e100ms\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eData Refresh\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003eRS485\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eInterface\u003c\/div\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eWhat the Power Sensor Enables\u003c\/h2\u003e\n  \u003cp\u003ePositioned at the main grid connection point, the Power Sensor delivers live three-phase import\/export data to the Energy Controller every 100ms — enabling precise, real-time energy management across the full site load at commercial and industrial scale:\u003c\/p\u003e\n  \u003cul class=\"sgs-enables-list\"\u003e\n    \u003cli\u003eDynamic load management — real-time inverter\/battery throttling to prevent incomer overload\u003c\/li\u003e\n    \u003cli\u003eMaximum demand management — limits grid import below a contracted demand threshold\u003c\/li\u003e\n    \u003cli\u003eExport limitation — enforces a maximum export cap per DNO \/ G99 connection agreement\u003c\/li\u003e\n    \u003cli\u003eSelf-consumption optimisation — multi-inverter battery dispatch reduces import across all three phases\u003c\/li\u003e\n    \u003cli\u003eAI tariff scheduling — live consumption data feeds the mySigen AI energy optimiser\u003c\/li\u003e\n    \u003cli\u003eAccurate mySigen app energy flow display — site import\/export, solar generation, battery and load\u003c\/li\u003e\n    \u003cli\u003eAnti-backflow control when used with the Sigen Energy Gateway\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cdiv class=\"sgs-callout\"\u003e\n    \u003cp\u003e💡 \u003cstrong\u003eIndustrial-scale metering:\u003c\/strong\u003e The 600A CT rating and 36mm bore diameter accommodate the large busbars and cable cross-sections typical of industrial switchgear, MCC enclosures and commercial distribution systems with high-current incomers. This is the correct variant for sites with three-phase supplies rated above 300A per phase and up to 600A per phase.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eKey Features\u003c\/h2\u003e\n  \u003cdiv class=\"sgs-grid\"\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e🏭 3 × 600A Split-Core CTs — 36mm Bore\u003c\/strong\u003eThree split-core 600A current transformers are included. The 36mm inner bore diameter is sized for large-section cables and busbars found in industrial switchgear and commercial distribution panels. Split-core design allows the CT to be fitted around existing conductors with no disconnection or shutdown required — critical for installation on live commercial systems.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e⚡ Industrial Supply Coverage\u003c\/strong\u003eRated to 600A per phase, this sensor handles the largest three-phase supplies for which Sigenergy currently offers a metering solution. Supports 3P3W (delta) and 3P4W (star\/wye with neutral) configurations, with a voltage range of 173–480 Vac covering UK, European and international industrial supply standards.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e⚡ 100ms Data Refresh\u003c\/strong\u003eMeasurements update every 100 milliseconds, giving the Energy Controller real-time visibility of rapid load changes across all three phases simultaneously — essential for responsive demand management on industrial sites with large motor loads, compressors, or process equipment with high inrush currents.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e🎯 ±1% Power Accuracy\u003c\/strong\u003eVoltage ±0.5%, current ±0.5%, power ±1%, frequency ±0.2% — consistent across the full Sigen Sensor range regardless of CT size. Suitable for export limitation compliance, maximum demand management and Smart Export Guarantee metering.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e📺 LCD Real-Time Display\u003c\/strong\u003eIntegrated LCD displays live three-phase measurements at the unit — useful on large commercial installations where monitoring equipment may be in a separate control room and an on-site reading is needed during commissioning, maintenance or fault investigation.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e📐 DIN Rail Mounting\u003c\/strong\u003eStandard 35mm DIN rail installation for integration into commercial distribution boards and MCC panels. Sensor body dimensions: 72 × 94.5 × 65mm \/ 200g — the same compact form factor as the other three-phase CT variants.\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eThree Phase CT Rating Selection Guide\u003c\/h2\u003e\n  \u003ctable class=\"sgs-variant-table\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth\u003ePart No\u003c\/th\u003e\n        \u003cth\u003eCT Rating\u003c\/th\u003e\n        \u003cth\u003eCT Bore\u003c\/th\u003e\n        \u003cth\u003eTypical Application\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eSIG-SENSOR-TP-CT-DH\u003c\/td\u003e\n        \u003ctd\u003e120A\u003c\/td\u003e\n        \u003ctd\u003e16mm\u003c\/td\u003e\n        \u003ctd\u003eThree-phase residential and small commercial — up to 120A per phase\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eSIG-SENSOR-TP-CT300-DH\u003c\/td\u003e\n        \u003ctd\u003e300A\u003c\/td\u003e\n        \u003ctd\u003e—\u003c\/td\u003e\n        \u003ctd\u003eLight commercial \/ medium industrial — 121A to 300A per phase\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr class=\"col-highlight\"\u003e\n        \u003ctd\u003eSIG-SENSOR-TP-CT600-DH ★ (this product)\u003c\/td\u003e\n        \u003ctd\u003e600A\u003c\/td\u003e\n        \u003ctd\u003e36mm\u003c\/td\u003e\n        \u003ctd\u003eLarge commercial \/ industrial — 301A to 600A per phase\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable class=\"sgs-spec-table\"\u003e\n    \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eProduct Identity\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003ePart No\u003c\/td\u003e\n\u003ctd\u003eSIG-SENSOR-TP-CT600-DH\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSigenergy\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003ePower Supply \u0026amp; Grid Connection\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eGrid connection type\u003c\/td\u003e\n\u003ctd\u003e3P3W \/ 3P4W (three-phase three-wire \/ four-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eAC input voltage range\u003c\/td\u003e\n\u003ctd\u003e173–480 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eNominal AC frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eMeasurement Accuracy\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eVoltage accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCurrent accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003ePower accuracy\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eFrequency accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eData refresh rate\u003c\/td\u003e\n\u003ctd\u003e100ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eCommunication\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eBaud rate\u003c\/td\u003e\n\u003ctd\u003e9,600 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eGeneral Data — Sensor Body\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e72 × 94.5 × 65mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e200g\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD (real-time voltage, current, power, frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eInstallation method\u003c\/td\u003e\n\u003ctd\u003eDIN Rail 35mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eIngress protection rating\u003c\/td\u003e\n\u003ctd\u003eIP51\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e0–90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eCT Accessories (× 3 supplied)\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eNumber of CTs supplied\u003c\/td\u003e\n\u003ctd\u003e3 (one per phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCT type\u003c\/td\u003e\n\u003ctd\u003eSplit-core (clip-on, no disconnection required)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMax. operating current per CT\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCT inner bore diameter\u003c\/td\u003e\n\u003ctd\u003e36mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eStandards\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eStandard compliance\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1:2010, EN 61010-2-030:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003ch2\u003eFAQs\u003c\/h2\u003e\n  \u003cdiv class=\"sgs-faq-item\"\u003e\n    \u003ch3\u003eHow do I confirm which CT rating I need?\u003c\/h3\u003e\n    \u003cp\u003eCheck the rated current of the DNO main fuse or incomer protection device on each phase at the grid connection point. If the per-phase rating is between 301A and 600A, this 600A variant is the correct choice. If it is 300A or below, the \u003cstrong\u003eSIG-SENSOR-TP-CT300-DH\u003c\/strong\u003e provides adequate headroom with a smaller CT and may be easier to handle. Always select the CT rating that exceeds — not merely equals — your maximum expected per-phase current to preserve measurement accuracy at full load.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"sgs-faq-item\"\u003e\n    \u003ch3\u003eWill the 36mm bore CT fit around my cables or busbars?\u003c\/h3\u003e\n    \u003cp\u003eThe 36mm inner bore diameter accommodates cable conductors or busbar sections up to approximately 36mm in their narrowest dimension. For very large flat busbars or conductors in tight groupings, verify the physical dimensions on site before ordering. If the bore is insufficient, consult Sigenergy or your distributor — higher CT bore accessories may be available for large industrial installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"sgs-faq-item\"\u003e\n    \u003ch3\u003eIs a G99 application needed when connecting Sigenergy storage to an industrial supply?\u003c\/h3\u003e\n    \u003cp\u003eFor commercial and industrial installations connecting generating plant (including battery storage in export mode) to the Distribution Network, a G99 application to the DNO is typically required where total export capacity exceeds 16A per phase. The Power Sensor's export limitation capability allows the system to enforce a zero-export or maximum-export limit as a condition of the DNO connection agreement, but the G99 process itself must be managed by the responsible engineer or DNO connection team. This description is for general guidance only — always confirm compliance requirements with your DNO and a qualified electrical engineer.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"sgs-infobox\"\u003e\n    \u003cstrong\u003eℹ️ Often purchased with:\u003c\/strong\u003e\n    \u003cstrong\u003eSigenStor EC TP series or multi-inverter SigenStor stacks\u003c\/strong\u003e — three-phase Energy Controllers for large commercial installations ·\n    \u003cstrong\u003eSigen Energy Gateway HomePro\u003c\/strong\u003e — site-wide backup switching and demand management ·\n    \u003cstrong\u003eSIG-SENSOR-TP-CT300-DH\u003c\/strong\u003e — if supply is rated 300A or below ·\n    \u003cstrong\u003eSigen CommMod (11170009)\u003c\/strong\u003e — 4G connectivity where Ethernet is not available at the inverter location\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Sigenergy","offers":[{"title":"Default Title","offer_id":63581187637597,"sku":"SIG-SENSOR-TP-CT600-DH","price":320.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SigenergyPowerSensorThreePhaseExternalCTDH.jpg?v=1771914600"},{"product_id":"sigenergy-sigen-power-sensor-single-phase-external-ct-120a-din-rail-rs485-solar-import-export-monitoring","title":"Sigenergy Sigen Power Sensor | Single Phase External CT 120A | DIN Rail | RS485 | Solar Import\/Export Monitoring","description":"\u003cstyle\u003e\n  .sgs-desc * { box-sizing: border-box; }\n  .sgs-desc { font-family: inherit; color: inherit; line-height: 1.7; font-size: 16px; }\n  .sgs-desc p, .sgs-desc li, .sgs-desc td, .sgs-desc th { font-size: 16px !important; line-height: 1.7; }\n  .sgs-desc h2 { font-size: 22px !important; font-weight: 700; color: #0d1a2e; border-bottom: 2px solid #e8401c; padding-bottom: 6px; margin: 2rem 0 1rem; line-height: 1.3; }\n  .sgs-desc h3 { font-size: 17px !important; font-weight: 700; color: #0d1a2e; margin: 1.2rem 0 0.4rem; line-height: 1.4; }\n  .sgs-desc p { margin: 0 0 1rem; }\n  .sgs-desc ul { padding-left: 1.5rem; margin: 0 0 1rem; }\n  .sgs-desc ul li { margin-bottom: 0.5rem; }\n\n  .sgs-intro-box { background: #fdf0ed; border-left: 4px solid #e8401c; padding: 1.1rem 1.4rem; border-radius: 0 6px 6px 0; margin-bottom: 1.5rem; }\n  .sgs-intro-box p { margin: 0 !important; }\n\n  .sgs-badge { display: inline-block; background: #e8401c; color: #fff; font-size: 13px !important; font-weight: 700; border-radius: 4px; padding: 2px 10px; margin-right: 6px; margin-bottom: 4px; vertical-align: middle; }\n  .sgs-badge.dark { background: #0d1a2e; }\n  .sgs-badge.grey { background: #555; }\n  .sgs-badge.green { background: #1a7a3c; }\n\n  .sgs-stat-bar { background: #0d1a2e; color: #fff; border-radius: 8px; padding: 1.1rem 1.4rem; margin: 1.2rem 0; display: flex; flex-wrap: wrap; gap: 1.5rem; align-items: center; justify-content: space-around; }\n  .sgs-stat { text-align: center; }\n  .sgs-stat .num { font-size: 26px !important; font-weight: 800; color: #ff7a5a; line-height: 1; }\n  .sgs-stat .lbl { font-size: 12px !important; color: #aab; margin-top: 2px; }\n\n  .sgs-grid { display: grid; grid-template-columns: repeat(auto-fill, minmax(230px, 1fr)); gap: 0.85rem; margin-bottom: 1.2rem; }\n  .sgs-card { background: #fdf0ed; border: 1px solid #f5c4b8; border-radius: 6px; padding: 1rem 1.1rem; line-height: 1.6; }\n  .sgs-card strong { display: block; color: #0d1a2e; margin-bottom: 0.35rem; font-size: 16px !important; }\n\n  .sgs-enables-list { list-style: none !important; padding: 0 !important; margin: 0 0 1rem !important; display: grid; grid-template-columns: repeat(auto-fill, minmax(260px, 1fr)); gap: 0.5rem; }\n  .sgs-enables-list li { background: #fdf0ed; border: 1px solid #f5c4b8; border-radius: 5px; padding: 0.55rem 1rem 0.55rem 2.2rem !important; position: relative; font-size: 15px !important; margin: 0 !important; line-height: 1.55; }\n  .sgs-enables-list li::before { content: \"✓\"; position: absolute; left: 0.7rem; color: #e8401c; font-weight: 700; }\n\n  .sgs-variant-table { width: 100%; border-collapse: collapse; margin-bottom: 1.2rem; }\n  .sgs-variant-table th { background: #0d1a2e; color: #fff !important; padding: 0.65rem 0.9rem; font-size: 14px !important; text-align: left; }\n  .sgs-variant-table th:not(:first-child) { text-align: center; }\n  .sgs-variant-table td { padding: 0.55rem 0.9rem; border-bottom: 1px solid #e8e0de; font-size: 14px !important; }\n  .sgs-variant-table td:not(:first-child) { text-align: center; }\n  .sgs-variant-table tr:nth-child(even) td { background: #fdf0ed; }\n  .sgs-variant-table td:first-child { font-weight: 600; color: #111; }\n  .sgs-variant-table .col-highlight td { background: #fdf0ed; font-weight: 700; color: #e8401c !important; }\n  .sgs-variant-table .col-highlight td:first-child { color: #e8401c !important; }\n\n  .sgs-callout { background: #fff8e6; border: 1px solid #f0d080; border-radius: 6px; padding: 1rem 1.3rem; margin: 1.2rem 0; color: #5a4a00; }\n  .sgs-callout p { margin: 0 !important; }\n\n  .sgs-spec-table { width: 100%; border-collapse: collapse; margin-bottom: 1.5rem; }\n  .sgs-spec-table th { background: #0d1a2e; color: #fff !important; text-align: left; padding: 0.7rem 1rem; font-weight: 700; font-size: 16px !important; }\n  .sgs-spec-table td { padding: 0.6rem 1rem; border-bottom: 1px solid #e8e0de; vertical-align: top; font-size: 16px !important; }\n  .sgs-spec-table tr:nth-child(even) td { background: #fdf0ed; }\n  .sgs-spec-table td:first-child { font-weight: 600; color: #111; width: 44%; }\n  .sgs-spec-table .section-head td { background: #e8401c !important; color: #fff !important; font-weight: 700 !important; font-size: 14px !important; text-transform: uppercase; letter-spacing: 0.05em; }\n\n  .sgs-faq-item { border-bottom: 1px solid #e8e0de; padding: 1rem 0; }\n  .sgs-faq-item:last-child { border-bottom: none; }\n  .sgs-faq-item p { margin: 0.4rem 0 0 !important; }\n\n  .sgs-infobox { background: #fdf0ed; border: 1px solid #f5c4b8; border-radius: 6px; padding: 1rem 1.2rem; margin-top: 1.5rem; font-size: 16px !important; line-height: 1.6; }\n\n  @media (max-width: 600px) {\n    .sgs-grid { grid-template-columns: 1fr 1fr; }\n    .sgs-stat-bar { justify-content: center; }\n    .sgs-enables-list { grid-template-columns: 1fr; }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"sgs-desc\"\u003e\n\n  \u003cdiv class=\"sgs-intro-box\"\u003e\n    \u003cp\u003e\n      \u003cspan class=\"sgs-badge\"\u003eSingle Phase\u003c\/span\u003e\n      \u003cspan class=\"sgs-badge dark\"\u003e1 × 120A CT Included\u003c\/span\u003e\n      \u003cspan class=\"sgs-badge green\"\u003e±1% Accuracy\u003c\/span\u003e\n      \u003cspan class=\"sgs-badge grey\"\u003ePart No: SIG-SENSOR-SP-CT-DH\u003c\/span\u003e\n    \u003c\/p\u003e\n    \u003cp style=\"margin-top:0.75rem !important;\"\u003eThe \u003cstrong\u003eSigenergy Power Sensor SP-CT-DH\u003c\/strong\u003e is a single-phase energy metering device that connects via RS485 to any compatible Sigenergy inverter or energy controller, giving the SigenStor EMS real-time, high-accuracy visibility of grid import and export. This external CT variant uses a \u003cstrong\u003esplit-core current transformer\u003c\/strong\u003e that clips around the existing main live conductor — no disconnection of live wiring required during installation. One 120A split-core CT with a 1m cable is included in the box. It is the recommended single-phase metering solution for installs where the main incoming cable cannot be routed through the sensor body, or where the incomer is too large for a direct-connection sensor.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"sgs-stat-bar\"\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e1-Phase\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003e1P2W\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e120A\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eCT Rating\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e±1%\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003ePower Accuracy\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003e100ms\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eData Refresh\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003eRS485\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eInterface\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sgs-stat\"\u003e\n\u003cdiv class=\"num\"\u003eIP51\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eProtection Rating\u003c\/div\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eWhat the Power Sensor Enables\u003c\/h2\u003e\n  \u003cp\u003ePositioned at the grid connection point, the Power Sensor feeds live import\/export data to the Energy Controller every 100ms via RS485 Modbus RTU. This measurement underpins the full range of SigenStor intelligent energy management features:\u003c\/p\u003e\n  \u003cul class=\"sgs-enables-list\"\u003e\n    \u003cli\u003eDynamic load management — throttles inverter output in real time to prevent main fuse overload\u003c\/li\u003e\n    \u003cli\u003eSolar surplus EV charging (Solar Boost, 100% PV, PV Storage \u0026amp; Charging modes) on the Sigen EV AC Charger\u003c\/li\u003e\n    \u003cli\u003eExport limitation — caps grid export for DNO \/ G98 compliance\u003c\/li\u003e\n    \u003cli\u003eImport limitation — prevents grid draw exceeding a set threshold\u003c\/li\u003e\n    \u003cli\u003eSelf-consumption optimisation — battery charges\/discharges to minimise import\u003c\/li\u003e\n    \u003cli\u003eAI tariff scheduling — real consumption data feeds the mySigen AI energy optimiser\u003c\/li\u003e\n    \u003cli\u003eAccurate mySigen app energy flow display — grid, solar, battery and household load\u003c\/li\u003e\n    \u003cli\u003eAnti-backflow protection when used with the Sigen Energy Gateway\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cdiv class=\"sgs-callout\"\u003e\n    \u003cp\u003e⚠️ \u003cstrong\u003eRequired for key functions:\u003c\/strong\u003e Dynamic load management and all solar-priority EV charging modes on the Sigen EV AC Charger \u003cstrong\u003erequire a Power Sensor\u003c\/strong\u003e. Without it, the SigenStor system has no visibility of household consumption and cannot prevent overload or optimise EV charging against solar surplus.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eKey Features\u003c\/h2\u003e\n  \u003cdiv class=\"sgs-grid\"\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e🔌 External Split-Core CT — No Live Disconnection\u003c\/strong\u003eThe included 120A split-core CT clips around the existing live conductor without any need to cut, disconnect or strip wiring. The split-core design opens on a hinge and snaps closed around the cable — making installation faster, safer, and suitable as a retrofit to systems already in service. CT bore diameter: 16mm; cable length: 1m.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e⚡ 100ms Data Refresh\u003c\/strong\u003eMeasurements update every 100 milliseconds over RS485 (Modbus RTU, 9600 baud). This rapid rate ensures the Energy Controller can react to sudden load changes fast enough to prevent overload trips or unnecessary grid draw in real time.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e🎯 ±1% Power Accuracy\u003c\/strong\u003eVoltage accuracy ±0.5%, current accuracy ±0.5%, power accuracy ±1%, frequency accuracy ±0.2%. Sufficient for export metering, demand management, and Smart Export Guarantee (SEG) export tracking.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e📺 LCD Real-Time Display\u003c\/strong\u003eIntegrated LCD shows live voltage, current, power and frequency — useful for commissioning and fault-finding without requiring the mySigen app. Installers get an instant at-a-glance view of grid conditions at the metering point.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e🔗 Plug-and-Play with Sigenergy Devices\u003c\/strong\u003eRS485 connection to the Energy Controller requires no configuration or pairing beyond standard Sigenergy commissioning. Compatible with all Sigen Energy Controller, Hybrid Inverter, Storage Controller and Energy Gateway products.\u003c\/div\u003e\n    \u003cdiv class=\"sgs-card\"\u003e\n\u003cstrong\u003e📐 DIN Rail Mounting\u003c\/strong\u003e35mm DIN rail mounting for direct installation in a domestic consumer unit or distribution board. Compact sensor body: 18 × 118 × 64mm \/ 70g — one of the most space-efficient units in the Sigen Sensor range.\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eSingle Phase Sensor Variants — Which to Choose\u003c\/h2\u003e\n  \u003ctable class=\"sgs-variant-table\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth\u003ePart No\u003c\/th\u003e\n        \u003cth\u003eType\u003c\/th\u003e\n        \u003cth\u003eMax Current\u003c\/th\u003e\n        \u003cth\u003eCT Included\u003c\/th\u003e\n        \u003cth\u003eBest For\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eSIG-SENSOR-SP-DH\u003c\/td\u003e\n        \u003ctd\u003eDirect connection\u003c\/td\u003e\n        \u003ctd\u003e100A\u003c\/td\u003e\n        \u003ctd\u003eBuilt-in (internal)\u003c\/td\u003e\n        \u003ctd\u003eInstalls where incomer cable routes through sensor body; tidy single-unit solution\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr class=\"col-highlight\"\u003e\n        \u003ctd\u003eSIG-SENSOR-SP-CT-DH ★ (this product)\u003c\/td\u003e\n        \u003ctd\u003eExternal CT\u003c\/td\u003e\n        \u003ctd\u003e120A (CT rated)\u003c\/td\u003e\n        \u003ctd\u003e1 × 120A split-core CT\u003c\/td\u003e\n        \u003ctd\u003eRetrofits, large cable sizes, or where cable cannot pass through sensor; clip-on installation\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable class=\"sgs-spec-table\"\u003e\n    \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eProduct Identity\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003ePart No\u003c\/td\u003e\n\u003ctd\u003eSIG-SENSOR-SP-CT-DH\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eDatasheet model designation\u003c\/td\u003e\n\u003ctd\u003eSP-CT120-DH\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSigenergy\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003ePower Supply \u0026amp; Grid Connection\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eGrid connection type\u003c\/td\u003e\n\u003ctd\u003e1P2W (single-phase two-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eAC input voltage range\u003c\/td\u003e\n\u003ctd\u003e176–276 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eNominal AC frequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eMeasurement Accuracy\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eVoltage accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCurrent accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003ePower accuracy\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eFrequency accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eData refresh rate\u003c\/td\u003e\n\u003ctd\u003e100ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eCommunication\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eBaud rate\u003c\/td\u003e\n\u003ctd\u003e9,600 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eGeneral Data — Sensor Body\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e18 × 118 × 64mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e70g\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD (real-time voltage, current, power, frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eInstallation method\u003c\/td\u003e\n\u003ctd\u003eDIN Rail 35mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eIngress protection rating\u003c\/td\u003e\n\u003ctd\u003eIP51\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e0–90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eCT Accessory (× 1 supplied)\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eNumber of CTs supplied\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCT type\u003c\/td\u003e\n\u003ctd\u003eSplit-core (clip-on, no disconnection required)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMax. operating current\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCT inner bore diameter\u003c\/td\u003e\n\u003ctd\u003e16mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCT cable length\u003c\/td\u003e\n\u003ctd\u003e1 metre\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eWeight per CT\u003c\/td\u003e\n\u003ctd\u003e90g\u003c\/td\u003e\n\u003c\/tr\u003e\n\n      \u003ctr class=\"section-head\"\u003e\u003ctd colspan=\"2\"\u003eStandards\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eStandard compliance\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1:2010, EN 61010-2-030:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003ch2\u003eFAQs\u003c\/h2\u003e\n  \u003cdiv class=\"sgs-faq-item\"\u003e\n    \u003ch3\u003eShould I choose this (SP-CT-DH) or the direct-connection sensor (SP-DH)?\u003c\/h3\u003e\n    \u003cp\u003eIf the main incoming live cable can physically pass through the sensor body, the direct-connection \u003cstrong\u003eSP-DH\u003c\/strong\u003e gives a slightly tidier, single-component installation with no separate CT to manage. The \u003cstrong\u003eSP-CT-DH\u003c\/strong\u003e (this product) is the better choice when the cable cannot be rerouted, when it is larger than the sensor body's aperture will accept, or when you are retrofitting to an existing installation and want to avoid any disconnection of live wiring. Both variants deliver identical measurement performance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"sgs-faq-item\"\u003e\n    \u003ch3\u003eIs the 120A CT suitable for my installation?\u003c\/h3\u003e\n    \u003cp\u003eMost UK single-phase residential supplies are rated at 60A, 80A or 100A at the DNO cutout fuse. The 120A CT in this product comfortably covers all of these. If you have an unusually large single-phase supply exceeding 120A, contact Sigenergy or your distributor — a higher-rated CT may be available as an accessory. For three-phase installations, see the TP variant range.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"sgs-faq-item\"\u003e\n    \u003ch3\u003eWhere exactly does the CT get installed?\u003c\/h3\u003e\n    \u003cp\u003eThe CT clips around the incoming main live conductor at the grid side of the installation — typically on the service tails between the DNO cutout fuse and the main switch in the consumer unit. It must be positioned to measure total grid import and export, on the grid side of the inverter connection point. The 1m CT cable runs back to the sensor body, which mounts on the DIN rail in the consumer unit.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"sgs-infobox\"\u003e\n    \u003cstrong\u003eℹ️ Often purchased with:\u003c\/strong\u003e\n    \u003cstrong\u003eSigenStor EC 3.6 SP or EC 6.0 SP\u003c\/strong\u003e — single-phase Energy Controllers this sensor monitors ·\n    \u003cstrong\u003eSigen EV AC Charger 7kW\u003c\/strong\u003e — Power Sensor required for solar charging modes ·\n    \u003cstrong\u003eSigen Gateway HomePro SP-F\u003c\/strong\u003e — works with Power Sensor for anti-backflow and load monitoring ·\n    \u003cstrong\u003eSIG-SENSOR-SP-DH\u003c\/strong\u003e — direct-connection alternative if cable routing permits\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Sigenergy","offers":[{"title":"Default Title","offer_id":63581200056669,"sku":"SIG-SENSOR-SP-CT-DH","price":110.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/eastron-SDM230-modbus.jpg?v=1763485387"},{"product_id":"sigenergy-sigen-power-sensor-single-phase-direct-connection-100a-din-rail-rs485-solar-import-export-monitoring","title":"Sigenergy 1-Phase Smart Meter with 100A CT | SP-CT100 | RS485","description":"\u003c!-- SEO Product Name: Sigenergy 1-Phase Smart Meter with 100A CT | SP-CT100 | RS485 --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; color:#1f2933; line-height:1.6;\"\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eSigenergy Sigen Sensor SP-CT100\u003c\/strong\u003e is a \u003cstrong\u003esingle phase smart power sensor\u003c\/strong\u003e that measures \u003cstrong\u003egrid import and export\u003c\/strong\u003e at the point of connection, so your Sigenergy system always knows what the property is drawing from or sending to the grid. It uses \u003cstrong\u003eindirect measurement\u003c\/strong\u003e through an \u003cstrong\u003eexternal 100 A current transformer (included)\u003c\/strong\u003e, and reports back over \u003cstrong\u003eRS485 using Modbus RTU\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eIt is the grid-side meter for \u003cstrong\u003eSigenStor and Sigen hybrid inverter\u003c\/strong\u003e installations on \u003cstrong\u003e1-phase supplies\u003c\/strong\u003e, enabling live energy-flow monitoring, \u003cstrong\u003eexport limitation\u003c\/strong\u003e and smart battery control. The compact \u003cstrong\u003e19 mm wide DIN rail\u003c\/strong\u003e housing fits neatly alongside the consumer unit or in a dedicated enclosure.\u003c\/p\u003e\n\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:10px; margin:20px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e1-Phase\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003e1P2W grid connection\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e100 A CT\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eIncluded, 24 mm inner diameter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eRS485\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eModbus RTU, 9,600 bps\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e1%\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003ePower measurement accuracy\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e19 mm\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eCompact DIN rail housing\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eIP20\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003e-25 to 65 °C operating range\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FDECEA; border-left:5px solid #C62828; border-radius:6px; padding:14px 16px; margin:14px 0;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#C62828; margin-bottom:4px;\"\u003eInstallation Safety\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933;\"\u003eInstallation must be carried out by a \u003cstrong\u003ecompetent, qualified electrician\u003c\/strong\u003e in line with \u003cstrong\u003eBS 7671\u003c\/strong\u003e and Sigenergy's installation guide. Isolate the supply before working on the meter or fitting the CT, and follow the manufacturer's instructions for CT orientation and wiring.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFF4E0; border-left:5px solid #E69100; border-radius:6px; padding:14px 16px; margin:14px 0;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#E69100; margin-bottom:4px;\"\u003eCompatibility\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933;\"\u003eThe SP-CT100 is a \u003cstrong\u003esingle phase\u003c\/strong\u003e sensor for \u003cstrong\u003e1P2W\u003c\/strong\u003e supplies. Three-phase properties require a three-phase Sigen power sensor. Always check your Sigenergy inverter or SigenStor model supports this sensor before ordering.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E6F2F1; border-left:5px solid #008377CF; border-radius:6px; padding:14px 16px; margin:14px 0;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:4px;\"\u003eWhat Is in the Box\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933;\"\u003e\n\u003cstrong\u003e1 x Sigen Sensor SP-CT100 meter\u003c\/strong\u003e and \u003cstrong\u003e1 x 100 A current transformer\u003c\/strong\u003e with a 1 m cable, so no separate CT purchase is needed.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"font-size:20px; font-weight:700; color:#008377CF; margin:26px 0 10px 0;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:12px; margin-bottom:24px;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:8px; padding:14px 16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eGrid Import and Export Metering\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933; font-size:15px;\"\u003eMeasures \u003cstrong\u003epower flowing to and from the grid\u003c\/strong\u003e at the supply point, giving the system the data it needs to balance solar, battery and household load.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:8px; padding:14px 16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003e1% Power Accuracy\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933; font-size:15px;\"\u003e\n\u003cstrong\u003e0.5% voltage and current accuracy\u003c\/strong\u003e (current from 4 to 100 A) and \u003cstrong\u003e1% power accuracy\u003c\/strong\u003e for dependable control and reporting.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:8px; padding:14px 16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eIncluded 100 A CT\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933; font-size:15px;\"\u003e\n\u003cstrong\u003eExternal CT rated to 100 A\u003c\/strong\u003e with a \u003cstrong\u003e24 mm inner diameter\u003c\/strong\u003e and \u003cstrong\u003e1 m lead\u003c\/strong\u003e supplied in the box.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:8px; padding:14px 16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eRS485 Modbus RTU\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933; font-size:15px;\"\u003eIndustry-standard \u003cstrong\u003eRS485 communication\u003c\/strong\u003e at \u003cstrong\u003e9,600 bps\u003c\/strong\u003e for a reliable, wired link to Sigenergy equipment.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:8px; padding:14px 16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eCompact DIN Rail Mount\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933; font-size:15px;\"\u003eJust \u003cstrong\u003e19 mm wide\u003c\/strong\u003e and \u003cstrong\u003e35 mm DIN rail\u003c\/strong\u003e mounted, weighing only \u003cstrong\u003e0.07 kg\u003c\/strong\u003e, so it takes minimal space in the enclosure.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #008377CF; border-top:4px solid #008377CF; border-radius:8px; padding:14px 16px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eWide Operating Range\u003c\/div\u003e\n\u003cdiv style=\"color:#1f2933; font-size:15px;\"\u003eWorks from \u003cstrong\u003e-25 to 65 °C\u003c\/strong\u003e and up to \u003cstrong\u003e95% relative humidity\u003c\/strong\u003e, across a \u003cstrong\u003e100 to 276 Vac\u003c\/strong\u003e input range at \u003cstrong\u003e50 \/ 60 Hz\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"font-size:20px; font-weight:700; color:#008377CF; margin:26px 0 4px 0;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:8px; overflow:hidden; margin:12px 0 24px 0;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px;\"\u003eGeneral\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eManufacturer\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003eSigenergy\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eModel \/ MPN\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003eSigen Sensor SP-CT100\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eGrid connection type\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e1P2W (single phase, two wire)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eMeasurement type\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003eIndirect, via external CT\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eMounting\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e35 mm DIN rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eIngress protection\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003eIP20 (indoor, inside an enclosure or consumer unit)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px;\"\u003eElectrical and Measurement\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eAC input voltage range\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e100 to 276 Vac\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eNominal frequency\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e50 \/ 60 Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eVoltage accuracy\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e0.5%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eCurrent accuracy\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e0.5% (4 to 100 A)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003ePower accuracy\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e1%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eFrequency accuracy\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e0.2%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px;\"\u003eCommunication\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eInterface\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003eRS485\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eProtocol\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003eModbus RTU\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eBaud rate\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e9,600 bps\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px;\"\u003eCurrent Transformer (Included)\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eNumber of CTs\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eRated current\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e100 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eCT inner diameter\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e24 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eCT cable length\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e1 m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eCT weight\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e0.09 kg\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px;\"\u003ePhysical and Environmental\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eDimensions (W x H x D)\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e19 x 94.5 x 68.5 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eMeter weight\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e0.07 kg\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eOperating temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e-25 to 65 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eStorage temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e-40 to 70 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#ffffff; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eRelative humidity\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003e0% to 95%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; background:#EEF6F5; padding:9px 14px; border-bottom:1px solid #d6e6e4;\"\u003e\n\u003cdiv style=\"flex:1 1 220px; font-weight:700; color:#1f2933;\"\u003eStandards\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 300px; color:#1f2933;\"\u003eEN 61010-1:2010, EN 61010-2-030:2010\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"font-size:20px; font-weight:700; color:#008377CF; margin:26px 0 10px 0;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:11px 14px; cursor:pointer;\"\u003eIs a current transformer included?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; color:#1f2933;\"\u003eYes. The kit includes \u003cstrong\u003eone 100 A CT\u003c\/strong\u003e with a 1 m cable and a 24 mm inner diameter. You do not need to buy a CT separately.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:11px 14px; cursor:pointer;\"\u003eIs this meter suitable for a three-phase supply?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; color:#1f2933;\"\u003eNo. The SP-CT100 is a \u003cstrong\u003esingle phase (1P2W)\u003c\/strong\u003e sensor. For three-phase properties you need a three-phase Sigen power sensor.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:11px 14px; cursor:pointer;\"\u003eWhat does the meter connect to?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; color:#1f2933;\"\u003eIt communicates over \u003cstrong\u003eRS485 (Modbus RTU)\u003c\/strong\u003e and is designed for use with \u003cstrong\u003eSigenergy SigenStor and Sigen hybrid inverter\u003c\/strong\u003e systems as the grid-side meter. Check compatibility of your specific inverter or storage model with Sigenergy before ordering.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:11px 14px; cursor:pointer;\"\u003eWhat is the maximum current it can measure?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; color:#1f2933;\"\u003eThe included CT is rated to \u003cstrong\u003e100 A\u003c\/strong\u003e, with \u003cstrong\u003e0.5% current accuracy across 4 to 100 A\u003c\/strong\u003e. This suits typical UK single phase domestic supplies.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:11px 14px; cursor:pointer;\"\u003eHow is the SP-CT100 mounted?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; color:#1f2933;\"\u003eIt clips onto \u003cstrong\u003e35 mm DIN rail\u003c\/strong\u003e. At 19 mm wide and IP20 rated, it should be installed inside a suitable enclosure or consumer unit by a qualified electrician.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:11px 14px; cursor:pointer;\"\u003eDoes the SP-CT100 need an installer?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px; color:#1f2933;\"\u003eYes. Wiring it into the supply and fitting the CT must be done by a \u003cstrong\u003ecompetent person\u003c\/strong\u003e in accordance with \u003cstrong\u003eBS 7671\u003c\/strong\u003e and the manufacturer's instructions.\u003c\/div\u003e\u003c\/details\u003e\n\n\u003c\/div\u003e","brand":"Sigenergy","offers":[{"title":"Default Title","offer_id":63581216833885,"sku":"14370005","price":99.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SigenergySP-CT1001phIndirectMeterwith100ACT.png?v=1792482656"},{"product_id":"sigenergy-gateway-c120-6-three-phase-120kw-up-to-6-sigenstor-units-backup","title":"Sigenergy Gateway C120-6 Three Phase 120kW | Up to 6 SigenStor Units Backup","description":"\u003cstyle\u003e\n.qh-pd, .qh-pd *::before, .qh-pd *::after { box-sizing: border-box; margin: 0; padding: 0; }\n.qh-pd { font-family: inherit; font-size: 16px; line-height: 1.65; color: #1a1a2e; }\n.qh-pd .badge-row { display: flex; flex-wrap: wrap; gap: 6px; margin-bottom: 1.2rem; }\n.qh-pd .badge { display: inline-block; font-size: 11px; font-weight: 700; border-radius: 4px; padding: 3px 9px; letter-spacing: 0.04em; text-transform: uppercase; }\n.qh-pd .b-orange { background: #e8720c; color: #fff; }\n.qh-pd .b-navy   { background: #1a1a2e; color: #fff; }\n.qh-pd .b-green  { background: #1b7a40; color: #fff; }\n.qh-pd .b-blue   { background: #1565c0; color: #fff; }\n.qh-pd .b-teal   { background: #006064; color: #fff; }\n.qh-pd .b-purple { background: #6a1b9a; color: #fff; }\n.qh-pd .b-red    { background: #b71c1c; color: #fff; }\n.qh-pd .b-grey   { background: #555;    color: #fff; }\n.qh-pd .prod-desc { font-size: 15.5px; color: #2a2a2a; margin-bottom: 1.4rem; line-height: 1.75; }\n.qh-pd .feat-list { list-style: none; margin-bottom: 1.4rem; padding: 0; }\n.qh-pd .feat-list li { padding: 4px 0 4px 20px; position: relative; font-size: 15px; }\n.qh-pd .feat-list li::before { content: \"✓\"; position: absolute; left: 0; color: #e8720c; font-weight: 700; }\n.qh-pd .section-label { font-size: 11px; font-weight: 700; letter-spacing: 0.12em; text-transform: uppercase; color: #888; margin-bottom: 0.6rem; margin-top: 1.6rem; }\n.qh-pd .table-scroll { width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch; margin-bottom: 1.5rem; border-radius: 8px; box-shadow: 0 1px 4px rgba(0,0,0,0.08); }\n.qh-pd .variant-table { width: 100%; border-collapse: collapse; font-size: 13px; min-width: 480px; }\n.qh-pd .variant-table thead tr { background: #1a1a2e; color: #fff; }\n.qh-pd .variant-table th { padding: 9px 12px; text-align: left; font-size: 10px; letter-spacing: 0.08em; text-transform: uppercase; font-weight: 700; white-space: nowrap; }\n.qh-pd .variant-table td { padding: 9px 12px; border-bottom: 1px solid #eee; vertical-align: top; }\n.qh-pd .variant-table tr:last-child td { border-bottom: none; }\n.qh-pd .variant-table tr:nth-child(even) td { background: #faf8f4; }\n.qh-pd .variant-table tr:nth-child(odd)  td { background: #fff; }\n.qh-pd .sku  { font-family: 'Courier New', monospace; font-size: 11.5px; background: #f0f0f0; padding: 2px 5px; border-radius: 3px; word-break: break-all; display: inline-block; }\n.qh-pd .mpn  { font-family: 'Courier New', monospace; font-size: 11.5px; color: #e8720c; font-weight: 700; word-break: break-word; }\n.qh-pd .power { font-weight: 700; color: #1a1a2e; white-space: nowrap; }\n.qh-pd .note  { font-size: 12px; color: #666; }\n.qh-pd .spec-table { width: 100%; border-collapse: collapse; margin-bottom: 1.5rem; font-size: 14px; }\n.qh-pd .spec-table td { padding: 8px 12px; border-bottom: 1px solid #eee; vertical-align: top; }\n.qh-pd .spec-table tr:nth-child(even) td { background: #faf8f4; }\n.qh-pd .spec-table tr:nth-child(odd)  td { background: #fff; }\n.qh-pd .spec-table td:first-child { font-weight: 600; color: #333; width: 38%; }\n.qh-pd .callout { padding: 0.8rem 1.1rem; border-radius: 0 6px 6px 0; margin: 0.8rem 0; font-size: 14.5px; }\n.qh-pd .callout-orange { background: #fff3e0; border-left: 4px solid #e8720c; color: #4a2500; }\n.qh-pd .callout-blue   { background: #e8f4fd; border-left: 4px solid #1565c0; color: #0a2a50; }\n.qh-pd .callout-green  { background: #e8f5e9; border-left: 4px solid #1b7a40; color: #0a2a18; }\n.qh-pd .callout-red    { background: #fdecea; border-left: 4px solid #b71c1c; color: #4a0a0a; }\n\u003c\/style\u003e\n\n\u003cdiv class=\"qh-pd\"\u003e\n\n  \u003cdiv class=\"badge-row\"\u003e\n    \u003cspan class=\"badge b-orange\"\u003eThree Phase\u003c\/span\u003e\n    \u003cspan class=\"badge b-navy\"\u003e120 kW Max Output\u003c\/span\u003e\n    \u003cspan class=\"badge b-purple\"\u003eUp to 6 SigenStor Units\u003c\/span\u003e\n    \u003cspan class=\"badge b-blue\"\u003eWhole \u0026amp; Partial Home Backup\u003c\/span\u003e\n    \u003cspan class=\"badge b-green\"\u003eGenerator Ready\u003c\/span\u003e\n    \u003cspan class=\"badge b-teal\"\u003e0 ms Switchover\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cp class=\"prod-desc\"\u003e\n    The Sigenergy Gateway C120-6 is a three-phase commercial and industrial energy gateway that enables seamless backup power, intelligent energy management, and generator integration across installations of up to six SigenStor Energy Controllers. With a maximum backup output of 120 kW across three phases, it is suited to small and medium commercial premises, larger residential properties, and multi-unit residential developments. Multiple breaker positions within the enclosure support a mix of SigenStor loads and other critical circuits. In the event of a grid outage, the gateway executes a 0 ms load-side transition — using Sigenergy's patented switchover algorithm — so connected loads experience no interruption. A 350 ms reverse power flow protection circuit safeguards both the grid connection and any connected generator. Smart Port connectivity enables centralised monitoring and control via the mySigen App.\n  \u003c\/p\u003e\n\n  \u003cul class=\"feat-list\"\u003e\n    \u003cli\u003eSupports up to 6 SigenStor Energy Controllers — scales from 60 kW to 120 kW of connected generation\u003c\/li\u003e\n    \u003cli\u003e120 kW maximum three-phase backup output — suited to commercial premises and larger sites\u003c\/li\u003e\n    \u003cli\u003e0 ms load-side switchover — patented algorithm; connected loads experience no interruption\u003c\/li\u003e\n    \u003cli\u003e350 ms reverse power flow protection — protects grid and generator connections\u003c\/li\u003e\n    \u003cli\u003eWhole home and partial home backup — configurable via internal breaker positions\u003c\/li\u003e\n    \u003cli\u003eGenerator-ready — supports diesel or gas generator with 2-wire auto-start control\u003c\/li\u003e\n    \u003cli\u003eHeat pump and controllable load integration — smart port supports direct load control\u003c\/li\u003e\n    \u003cli\u003eUninterrupted power supply via combined PV, ESS, grid, and generator sources\u003c\/li\u003e\n    \u003cli\u003emySigen App monitoring — energy flow, backup status, and load control remotely\u003c\/li\u003e\n    \u003cli\u003eAluminium construction — lightweight, corrosion-resistant, extended service life\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cdiv class=\"callout callout-blue\"\u003e\n    ℹ️ \u003cstrong\u003eC120-6 vs C60-2:\u003c\/strong\u003e The C120-6 connects up to 6 SigenStor units and delivers up to 120 kW; the C60-2 connects up to 2 units for up to 60 kW. For sites running two EC TP units at up to 25 kW each with full home backup, the C60-2 is sufficient. The C120-6 is required when three or more Energy Controllers are deployed or when backup load demand exceeds 60 kW.\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"section-label\"\u003eProduct Details \u0026amp; Specifications\u003c\/div\u003e\n  \u003ctable class=\"spec-table\"\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"sku\"\u003eSIG-GATEWAY-TP-C120-6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManufacturer MPN\u003c\/td\u003e\n\u003ctd\u003eSigen Gateway C120-6\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMax Backup Output\u003c\/td\u003e\n\u003ctd\u003e120 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMax Connected SigenStor Units\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eGrid Switchover Time\u003c\/td\u003e\n\u003ctd\u003e0 ms (load side) — patented\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eReverse Power Flow Protection\u003c\/td\u003e\n\u003ctd\u003e350 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Mode\u003c\/td\u003e\n\u003ctd\u003eWhole home backup \u0026amp; partial home backup\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eGenerator Support\u003c\/td\u003e\n\u003ctd\u003eYes — 2-wire auto-start, diesel or gas\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSmart Load Control\u003c\/td\u003e\n\u003ctd\u003eHeat pump, EV charger, and other controllable loads\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eAluminium enclosure — corrosion-resistant, lightweight\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003emySigen App \/ Smart Port\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCompatible Inverters\u003c\/td\u003e\n\u003ctd\u003eSigenStor EC TP (three phase) series\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv class=\"callout callout-orange\"\u003e\n    ⚠️ \u003cstrong\u003eProfessional installation required:\u003c\/strong\u003e The Gateway C120-6 is a high-power distribution and switching device. Installation must be carried out by a qualified electrician familiar with three-phase systems and DNO notification requirements. Datasheet available on request — please contact us by email.\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Sigenergy","offers":[{"title":"Default Title","offer_id":63627660362077,"sku":"SIG-GATEWAY-TP-C120-6","price":4300.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SigenergyGatewayHomeMaxC120SeriesThreePhase.jpg?v=1772097818"},{"product_id":"sigenergy-gateway-c60-2-three-phase-60kw-sig-gateway-tp-c60-2-2x-sigenstor-full-home-backup","title":"Sigenergy Gateway C60-2 Three Phase 60kW | SIG-GATEWAY-TP-C60-2 | 2x SigenStor Full Home Backup","description":"\u003cstyle\u003e\n.qh-pd, .qh-pd *::before, .qh-pd *::after { box-sizing: border-box; margin: 0; padding: 0; }\n.qh-pd { font-family: inherit; font-size: 16px; line-height: 1.65; color: #1a1a2e; }\n.qh-pd .badge-row { display: flex; flex-wrap: wrap; gap: 6px; margin-bottom: 1.2rem; }\n.qh-pd .badge { display: inline-block; font-size: 11px; font-weight: 700; border-radius: 4px; padding: 3px 9px; letter-spacing: 0.04em; text-transform: uppercase; }\n.qh-pd .b-orange { background: #e8720c; color: #fff; }\n.qh-pd .b-navy   { background: #1a1a2e; color: #fff; }\n.qh-pd .b-green  { background: #1b7a40; color: #fff; }\n.qh-pd .b-blue   { background: #1565c0; color: #fff; }\n.qh-pd .b-teal   { background: #006064; color: #fff; }\n.qh-pd .b-purple { background: #6a1b9a; color: #fff; }\n.qh-pd .b-red    { background: #b71c1c; color: #fff; }\n.qh-pd .b-grey   { background: #555;    color: #fff; }\n.qh-pd .prod-desc { font-size: 15.5px; color: #2a2a2a; margin-bottom: 1.4rem; line-height: 1.75; }\n.qh-pd .feat-list { list-style: none; margin-bottom: 1.4rem; padding: 0; }\n.qh-pd .feat-list li { padding: 4px 0 4px 20px; position: relative; font-size: 15px; }\n.qh-pd .feat-list li::before { content: \"✓\"; position: absolute; left: 0; color: #e8720c; font-weight: 700; }\n.qh-pd .section-label { font-size: 11px; font-weight: 700; letter-spacing: 0.12em; text-transform: uppercase; color: #888; margin-bottom: 0.6rem; margin-top: 1.6rem; }\n.qh-pd .table-scroll { width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch; margin-bottom: 1.5rem; border-radius: 8px; box-shadow: 0 1px 4px rgba(0,0,0,0.08); }\n.qh-pd .variant-table { width: 100%; border-collapse: collapse; font-size: 13px; min-width: 480px; }\n.qh-pd .variant-table thead tr { background: #1a1a2e; color: #fff; }\n.qh-pd .variant-table th { padding: 9px 12px; text-align: left; font-size: 10px; letter-spacing: 0.08em; text-transform: uppercase; font-weight: 700; white-space: nowrap; }\n.qh-pd .variant-table td { padding: 9px 12px; border-bottom: 1px solid #eee; vertical-align: top; }\n.qh-pd .variant-table tr:last-child td { border-bottom: none; }\n.qh-pd .variant-table tr:nth-child(even) td { background: #faf8f4; }\n.qh-pd .variant-table tr:nth-child(odd)  td { background: #fff; }\n.qh-pd .sku  { font-family: 'Courier New', monospace; font-size: 11.5px; background: #f0f0f0; padding: 2px 5px; border-radius: 3px; word-break: break-all; display: inline-block; }\n.qh-pd .mpn  { font-family: 'Courier New', monospace; font-size: 11.5px; color: #e8720c; font-weight: 700; word-break: break-word; }\n.qh-pd .power { font-weight: 700; color: #1a1a2e; white-space: nowrap; }\n.qh-pd .note  { font-size: 12px; color: #666; }\n.qh-pd .spec-table { width: 100%; border-collapse: collapse; margin-bottom: 1.5rem; font-size: 14px; }\n.qh-pd .spec-table td { padding: 8px 12px; border-bottom: 1px solid #eee; vertical-align: top; }\n.qh-pd .spec-table tr:nth-child(even) td { background: #faf8f4; }\n.qh-pd .spec-table tr:nth-child(odd)  td { background: #fff; }\n.qh-pd .spec-table td:first-child { font-weight: 600; color: #333; width: 38%; }\n.qh-pd .callout { padding: 0.8rem 1.1rem; border-radius: 0 6px 6px 0; margin: 0.8rem 0; font-size: 14.5px; }\n.qh-pd .callout-orange { background: #fff3e0; border-left: 4px solid #e8720c; color: #4a2500; }\n.qh-pd .callout-blue   { background: #e8f4fd; border-left: 4px solid #1565c0; color: #0a2a50; }\n.qh-pd .callout-green  { background: #e8f5e9; border-left: 4px solid #1b7a40; color: #0a2a18; }\n.qh-pd .callout-red    { background: #fdecea; border-left: 4px solid #b71c1c; color: #4a0a0a; }\n\u003c\/style\u003e\n\n\u003cdiv class=\"qh-pd\"\u003e\n\n  \u003cdiv class=\"badge-row\"\u003e\n    \u003cspan class=\"badge b-orange\"\u003eThree Phase\u003c\/span\u003e\n    \u003cspan class=\"badge b-navy\"\u003e60 kW Max Output\u003c\/span\u003e\n    \u003cspan class=\"badge b-purple\"\u003eUp to 2 SigenStor Units\u003c\/span\u003e\n    \u003cspan class=\"badge b-blue\"\u003eFull Home Backup\u003c\/span\u003e\n    \u003cspan class=\"badge b-green\"\u003eGenerator Ready\u003c\/span\u003e\n    \u003cspan class=\"badge b-teal\"\u003e0 ms Switchover\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cp class=\"prod-desc\"\u003e\n    The Sigenergy Gateway C60-2 is the entry-point three-phase energy gateway in the Sigenergy C\u0026amp;I range, designed for residential three-phase properties and small commercial premises with up to two SigenStor Energy Controllers. With a maximum backup output of 60 kW, it can support two EC TP units at up to 25 kW each — delivering full three-phase home backup for a typical UK house. Like all Sigenergy gateways, it uses the patented 0 ms load-side switchover, 350 ms reverse power flow protection, and supports generator integration via 2-wire auto-start. Multiple internal breaker positions allow selective circuit protection for either whole-home or partial backup configurations.\n  \u003c\/p\u003e\n\n  \u003cul class=\"feat-list\"\u003e\n    \u003cli\u003eDesigned for 2x SigenStor EC TP units — ideal for full three-phase home backup on a standard UK property\u003c\/li\u003e\n    \u003cli\u003e60 kW maximum three-phase backup output — sufficient for most domestic and small commercial loads\u003c\/li\u003e\n    \u003cli\u003e0 ms load-side switchover — no interruption to connected loads on grid loss\u003c\/li\u003e\n    \u003cli\u003e350 ms reverse power flow protection — grid and generator protection\u003c\/li\u003e\n    \u003cli\u003eWhole home and partial home backup modes — configured via internal breaker positions\u003c\/li\u003e\n    \u003cli\u003eGenerator-ready — 2-wire auto-start for diesel or gas generators\u003c\/li\u003e\n    \u003cli\u003eSmart load control — heat pump, EV charger, and other controllable loads via Smart Port\u003c\/li\u003e\n    \u003cli\u003emySigen App monitoring — real-time energy flow, backup status, remote control\u003c\/li\u003e\n    \u003cli\u003eAluminium construction — rust-free, lightweight, extended service life\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cdiv class=\"callout callout-blue\"\u003e\n    ℹ️ \u003cstrong\u003eC60-2 vs C120-6:\u003c\/strong\u003e The C60-2 supports up to 2 SigenStor units (up to 60 kW) and is the right choice for most three-phase residential installations. If more than two Energy Controllers are needed or backup demand exceeds 60 kW, use the C120-6 instead.\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"section-label\"\u003eProduct Details \u0026amp; Specifications\u003c\/div\u003e\n  \u003ctable class=\"spec-table\"\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"sku\"\u003eSIG-GATEWAY-TP-C60-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManufacturer MPN\u003c\/td\u003e\n\u003ctd\u003eSigen Gateway C60-2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMax Backup Output\u003c\/td\u003e\n\u003ctd\u003e60 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMax Connected SigenStor Units\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eGrid Switchover Time\u003c\/td\u003e\n\u003ctd\u003e0 ms (load side) — patented\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eReverse Power Flow Protection\u003c\/td\u003e\n\u003ctd\u003e350 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackup Mode\u003c\/td\u003e\n\u003ctd\u003eWhole home backup \u0026amp; partial home backup\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eGenerator Support\u003c\/td\u003e\n\u003ctd\u003eYes — 2-wire auto-start, diesel or gas\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSmart Load Control\u003c\/td\u003e\n\u003ctd\u003eHeat pump, EV charger, and other controllable loads\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eAluminium enclosure — corrosion-resistant, lightweight\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003emySigen App \/ Smart Port\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCompatible Inverters\u003c\/td\u003e\n\u003ctd\u003eSigenStor EC TP (three phase) series\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv class=\"callout callout-orange\"\u003e\n    ⚠️ \u003cstrong\u003eProfessional installation required:\u003c\/strong\u003e The Gateway C60-2 is a high-power distribution and switching device. Installation must be carried out by a qualified electrician familiar with three-phase systems. Datasheet available on request — please contact us by email.\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Sigenergy","offers":[{"title":"Default Title","offer_id":63627734188381,"sku":"SIG-GATEWAY-TP-C60-2","price":1245.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SigenergyGatewayHomePro.webp?v=1772097818"},{"product_id":"viridian-ct-clamp-for-clearline-inverter-vir-csi-ct-export-power-limiting-dno-compliance-g98-g99-export-cap-requires-vir-csi-wifi","title":"Viridian CT Clamp for Clearline Inverter | VIR-CSI-CT | Export Power Limiting | DNO Compliance | G98 G99 Export Cap | Requires VIR-CSI-WIFI","description":"\u003cdiv style=\"font-family:inherit;font-size:16px;line-height:1.65;color:#1a1a1a;\"\u003e\n\u003cp style=\"margin-bottom:1.25rem;line-height:2.2;\"\u003e\n\u003cspan style=\"display:inline-block;background:#c0392b;color:#ffffff;border:1.5px solid #c0392b;border-radius:4px;padding:3px 10px;font-size:11px;font-weight:700;letter-spacing:.05em;text-transform:uppercase;line-height:1.6;margin-right:5px;margin-bottom:5px;\"\u003eExport Power Limiting\u003c\/span\u003e\n\u003cspan style=\"display:inline-block;background:#1d4d1d;color:#ffffff;border:1.5px solid #1d4d1d;border-radius:4px;padding:3px 10px;font-size:11px;font-weight:700;letter-spacing:.05em;text-transform:uppercase;line-height:1.6;margin-right:5px;margin-bottom:5px;\"\u003eDNO Compliance\u003c\/span\u003e\n\u003cspan style=\"display:inline-block;background:#2e6e2e;color:#ffffff;border:1.5px solid #2e6e2e;border-radius:4px;padding:3px 10px;font-size:11px;font-weight:700;letter-spacing:.05em;text-transform:uppercase;line-height:1.6;margin-right:5px;margin-bottom:5px;\"\u003eGrid Import\/Export Meter\u003c\/span\u003e\n\u003cspan style=\"display:inline-block;background:#e8850a;color:#ffffff;border:1.5px solid #e8850a;border-radius:4px;padding:3px 10px;font-size:11px;font-weight:700;letter-spacing:.05em;text-transform:uppercase;line-height:1.6;margin-right:5px;margin-bottom:5px;\"\u003eClearline Inverter Add-On\u003c\/span\u003e\n\u003cspan style=\"display:inline-block;background:#555555;color:#ffffff;border:1.5px solid #555555;border-radius:4px;padding:3px 10px;font-size:11px;font-weight:700;letter-spacing:.05em;text-transform:uppercase;line-height:1.6;margin-right:5px;margin-bottom:5px;\"\u003eRequires WiFi Module\u003c\/span\u003e\n\u003cspan style=\"display:inline-block;background:#ffffff;color:#2e6e2e;border:1.5px solid #2e6e2e;border-radius:4px;padding:3px 10px;font-size:11px;font-weight:700;letter-spacing:.05em;text-transform:uppercase;line-height:1.6;margin-right:5px;margin-bottom:5px;\"\u003eViridian Solar\u003c\/span\u003e\n\u003c\/p\u003e\n\u003cp style=\"font-size:15.5px;color:#2a2a2a;margin-bottom:1.4rem;line-height:1.8;\"\u003eThe \u003cstrong style=\"color:#1d4d1d;\"\u003eViridian CT Clamp for Clearline Inverter\u003c\/strong\u003e (VIR-CSI-CT) is the current transformer accessory that enables \u003cstrong style=\"color:#1d4d1d;\"\u003eexport power limiting\u003c\/strong\u003e on Clearline CSI inverters. Installed on the main grid supply cable in the consumer unit, it continuously measures the real-time power flow at the grid connection point and sends this data to the inverter, which dynamically adjusts its output to stay within a configured maximum export limit. This is essential where your \u003cstrong style=\"color:#1d4d1d;\"\u003eDNO (Distribution Network Operator) connection approval specifies a maximum permitted export\u003c\/strong\u003e — for example, a G98 approval with a 3.68 kW export cap or a G99 approval with a specific export level. The CT clamp \u003cstrong style=\"color:#1d4d1d;\"\u003emust be used alongside the VIR-CSI-WIFI WiFi module\u003c\/strong\u003e — both are required for the export limiting function to operate.\u003c\/p\u003e\n\u003cp style=\"background:#fdf0ed;border-left:4px solid #c0392b;border-radius:0 6px 6px 0;padding:.85rem 1.15rem;margin:.9rem 0;font-size:14.5px;line-height:1.7;color:#4a0800;\"\u003e🔴 \u003cstrong style=\"color:#1d4d1d;\"\u003eImportant:\u003c\/strong\u003e The CT clamp must be installed on the \u003cstrong style=\"color:#1d4d1d;\"\u003egrid supply cable\u003c\/strong\u003e (the live conductor between the electricity meter and the consumer unit) by a \u003cstrong style=\"color:#1d4d1d;\"\u003equalified electrician\u003c\/strong\u003e. Incorrect installation will result in incorrect export measurement and may cause the inverter to export more power than permitted. \u003cstrong style=\"color:#1d4d1d;\"\u003eBoth VIR-CSI-WIFI and VIR-CSI-CT are required for export limiting — neither works for this purpose without the other.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:10.5px;font-weight:800;letter-spacing:.14em;text-transform:uppercase;color:#2e6e2e;margin-top:1.7rem;margin-bottom:.55rem;padding-bottom:4px;border-bottom:2px solid #2e6e2e;\"\u003eKey Features\u003c\/p\u003e\n\u003cul style=\"list-style:none;padding:0;margin:0 0 1.4rem 0;\"\u003e\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eEnables export power limiting\u003c\/strong\u003e on any Clearline CSI inverter — essential for DNO compliance where a maximum export cap is specified in your G98\/G99 connection approval\u003c\/li\u003e\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eClamp-on installation\u003c\/strong\u003e — clips around the live (or neutral) grid supply conductor; no need to cut or splice the cable, minimising installation time\u003c\/li\u003e\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eConnects to the inverter's RS485\/CT communication port\u003c\/strong\u003e — dedicated port on all Clearline CSI models; no external data logger or meter required\u003c\/li\u003e\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eContinuous real-time measurement\u003c\/strong\u003e — the inverter reads the CT output many times per second and adjusts its AC output power in real time to maintain the export set-point\u003c\/li\u003e\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eSet export limit via WE Mate app\u003c\/strong\u003e — the installer configures the target export power level (in watts) under Advanced Settings → Power Limit; the inverter maintains this limit automatically\u003c\/li\u003e\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eZero-export operation\u003c\/strong\u003e — set the export limit to 0 W if your DNO or DNO approval requires no export at all (self-consumption only mode)\u003c\/li\u003e\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eWorks with all Clearline CSI models\u003c\/strong\u003e — compatible with all single-phase Clearline inverters from CSI1000S through CSI6000D\u003c\/li\u003e\n  \u003cli style=\"padding:5px 0 5px 22px;position:relative;font-size:15px;line-height:1.65;\"\u003e\n\u003cspan style=\"position:absolute;left:0;color:#2e6e2e;font-weight:800;\"\u003e✓\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eMust be used with VIR-CSI-WIFI or VIR-CSI-WIFI-S\u003c\/strong\u003e — the WiFi module provides the communication pathway between the CT clamp reading and the inverter's power control algorithm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:10.5px;font-weight:800;letter-spacing:.14em;text-transform:uppercase;color:#2e6e2e;margin-top:1.7rem;margin-bottom:.55rem;padding-bottom:4px;border-bottom:2px solid #2e6e2e;\"\u003eWhen Do I Need a CT Clamp?\u003c\/p\u003e\n\u003cp style=\"background:#fef3e2;border-left:4px solid #e8850a;border-radius:0 6px 6px 0;padding:.85rem 1.15rem;margin:.9rem 0;font-size:14.5px;line-height:1.7;color:#4a2800;\"\u003e\u003cstrong style=\"color:#1d4d1d;\"\u003eYou need the CT clamp if your DNO connection approval (G98 or G99) includes any of the following:\u003c\/strong\u003e\n\n• A maximum permitted export power (e.g. 3.68 kW, 2 kW, or 0 kW)\n• A requirement for export limiting or zero-export operation\n• A condition that inverter output must be curtailed based on grid conditions\n\nIf your connection approval has no export restriction, the CT clamp is not required. Check your DNO connection offer letter or consult your MCS installer for guidance.\u003c\/p\u003e\n\u003cp style=\"font-size:10.5px;font-weight:800;letter-spacing:.14em;text-transform:uppercase;color:#2e6e2e;margin-top:1.7rem;margin-bottom:.55rem;padding-bottom:4px;border-bottom:2px solid #2e6e2e;\"\u003eTechnical Specifications\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;margin-bottom:1.5rem;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:13.5px;min-width:360px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#1d4d1d;color:#ffffff;font-weight:700;text-align:left;padding:7px 11px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background:#1d4d1d;color:#ffffff;font-weight:700;text-align:left;padding:7px 11px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;font-weight:600;color:#1d4d1d;\"\u003eFunction\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;\"\u003eCurrent transformer for real-time grid import\/export measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;font-weight:600;color:#1d4d1d;\"\u003eInstallation Point\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;\"\u003eGrid supply cable between electricity meter and consumer unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;font-weight:600;color:#1d4d1d;\"\u003eInstallation Method\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;\"\u003eClamp-on (split-core CT) — no cable cutting required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;font-weight:600;color:#1d4d1d;\"\u003eConnection to Inverter\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;\"\u003eRS485 \/ CT communication port (COM port 2 on all Clearline CSI models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;font-weight:600;color:#1d4d1d;\"\u003eRequired Companion\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;\"\u003eVIR-CSI-WIFI or VIR-CSI-WIFI-S WiFi module (must be fitted for export limiting to function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;font-weight:600;color:#1d4d1d;\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;\"\u003eVia WE Mate app — Advanced Settings → Power Limit → Enable Power Limit → Set Export Power and CT Ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;font-weight:600;color:#1d4d1d;\"\u003eCompatible Inverters\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;\"\u003eAll Viridian Clearline CSI range (CSI1000S–CSI6000D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;font-weight:600;color:#1d4d1d;\"\u003eInstaller Requirement\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#e8f5e8;\"\u003eQualified electrician — installation at consumer unit level involves live equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;font-weight:600;color:#1d4d1d;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #c8e6c8;vertical-align:top;background:#ffffff;\"\u003eViridian Solar Ltd, Papworth, Cambridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:10.5px;font-weight:800;letter-spacing:.14em;text-transform:uppercase;color:#2e6e2e;margin-top:1.7rem;margin-bottom:.55rem;padding-bottom:4px;border-bottom:2px solid #2e6e2e;\"\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp style=\"border-bottom:1px solid #c8e6c8;padding:.85rem 0 .85rem 1.4rem;position:relative;margin:0;\"\u003e\u003cspan style=\"position:absolute;left:0;top:.85rem;color:#2e6e2e;font-weight:900;font-size:14.5px;\"\u003eQ\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;font-size:14.5px;\"\u003eDo I need a CT clamp if my DNO approval has no export restriction?\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;color:#2a2a2a;line-height:1.7;\"\u003eNo. If your G98 or G99 connection approval places no restriction on export power, the CT clamp is not needed. Most simple domestic G98 systems under 3.68 kW can export freely. Check your DNO connection offer document to confirm whether an export limit applies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"border-bottom:1px solid #c8e6c8;padding:.85rem 0 .85rem 1.4rem;position:relative;margin:0;\"\u003e\u003cspan style=\"position:absolute;left:0;top:.85rem;color:#2e6e2e;font-weight:900;font-size:14.5px;\"\u003eQ\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;font-size:14.5px;\"\u003eCan I use the CT clamp without the WiFi module?\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;color:#2a2a2a;line-height:1.7;\"\u003eNo. \u003cstrong style=\"color:#1d4d1d;\"\u003eBoth the VIR-CSI-CT and VIR-CSI-WIFI are required together for export limiting.\u003c\/strong\u003e The CT clamp measures the current; the WiFi module communicates that measurement to the inverter's control system. Without the WiFi module, the inverter cannot read the CT clamp data.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"border-bottom:1px solid #c8e6c8;padding:.85rem 0 .85rem 1.4rem;position:relative;margin:0;\"\u003e\u003cspan style=\"position:absolute;left:0;top:.85rem;color:#2e6e2e;font-weight:900;font-size:14.5px;\"\u003eQ\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;font-size:14.5px;\"\u003eWhere exactly is the CT clamp installed?\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;color:#2a2a2a;line-height:1.7;\"\u003eThe CT clamp is installed on the \u003cstrong style=\"color:#1d4d1d;\"\u003emain grid supply conductor\u003c\/strong\u003e — typically the live (line) cable between your electricity meter and the main consumer unit. This allows it to measure the total power flowing to or from the grid (import and export). Installation at this point must be carried out by a qualified electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"border-bottom:1px solid #c8e6c8;padding:.85rem 0 .85rem 1.4rem;position:relative;margin:0;\"\u003e\u003cspan style=\"position:absolute;left:0;top:.85rem;color:#2e6e2e;font-weight:900;font-size:14.5px;\"\u003eQ\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;font-size:14.5px;\"\u003eCan I set zero export (self-consumption only)?\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;color:#2a2a2a;line-height:1.7;\"\u003eYes. Set the export limit to \u003cstrong style=\"color:#1d4d1d;\"\u003e0 W\u003c\/strong\u003e in the WE Mate app under Advanced Settings → Power Limit. The inverter will then continuously adjust its output to match household consumption, preventing any power from flowing back to the grid. Note that zero-export operation cannot be guaranteed under all dynamic conditions — response time means small transient exports may occasionally occur; this is normal and accepted by most DNOs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"border-bottom:1px solid #c8e6c8;padding:.85rem 0 .85rem 1.4rem;position:relative;margin:0;\"\u003e\u003cspan style=\"position:absolute;left:0;top:.85rem;color:#2e6e2e;font-weight:900;font-size:14.5px;\"\u003eQ\u003c\/span\u003e\u003cstrong style=\"color:#1d4d1d;font-size:14.5px;\"\u003eWhat happens if the CT clamp cable is disconnected after commissioning?\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;color:#2a2a2a;line-height:1.7;\"\u003eIf the CT clamp communication is lost, the inverter will typically fall back to outputting at its unrestricted rated power. This may cause an export limit breach. Ensure the CT cable is routed and secured to avoid accidental disconnection, and check the WE Mate app for any communication fault alerts.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Viridian Solar","offers":[{"title":"Default Title","offer_id":63646266294621,"sku":"VIR-CSI-CT","price":69.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Fox-ESS-CT-Clampwithcable.jpg?v=1765171650"},{"product_id":"solaredge-230-400v-energy-meter-with-modbus-connection","title":"SolarEdge 230\/400V Energy Meter with Modbus Connection","description":"\u003cdiv style=\"font-size:16px;font-family:Arial,Helvetica,sans-serif;color:#1a1a1a;max-width:900px;margin:0 auto;line-height:1.6;\"\u003e\n\n  \u003c!-- ── INTRO ─────────────────────────────────────────────────────── --\u003e\n  \u003cp style=\"margin:0 0 18px;\"\u003e\n    The \u003cstrong\u003eSolarEdge SE-WND-3Y400-MB-K2\u003c\/strong\u003e is SolarEdge's dedicated \u003cstrong\u003eModbus energy meter\u003c\/strong\u003e for accurate \u003cstrong\u003eproduction, consumption, and import\/export monitoring\u003c\/strong\u003e in both single-phase and three-phase solar PV installations. It connects to any SolarEdge inverter or Control and Communication Gateway via \u003cstrong\u003eRS485 Modbus\u003c\/strong\u003e, enabling real-time energy flow data in the SolarEdge monitoring platform. The \u003cstrong\u003eK2 version is required for export limitation (G100)\u003c\/strong\u003e — it supports Engineering Recommendation G100 Issue 1 Amendment 1 2017 and is the version specified by DNOs for feed-in control in the UK. Compact DIN-rail mounting and a \u003cstrong\u003e5-year warranty\u003c\/strong\u003e make it a standard inclusion on any SolarEdge installation.\n  \u003c\/p\u003e\n\n  \u003c!-- ── STAT STRIP ─────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin-bottom:20px;\"\u003e\n    \u003cdiv style=\"flex:1;min-width:120px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003e230\/400 V\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003e1PH \u0026amp; 3PH\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:120px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003eRS485\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eModbus connection\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:120px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003e±1.0%\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eAccuracy @ 25°C\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:120px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003eG100\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eExport limitation\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:120px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003e5 years\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eWarranty\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── RED INSTALLER CALLOUT ─────────────────────────────────────── --\u003e\n  \u003cdiv style=\"border-left:4px solid #c0392b;background:#fff5f5;padding:10px 16px;margin-bottom:14px;border-radius:0 6px 6px 0;\"\u003e\n    \u003cstrong style=\"color:#c0392b;\"\u003e⚠ Installer Note\u003c\/strong\u003e — Installation must be carried out by a qualified electrician. The meter operates at mains voltage. \u003cstrong\u003eAlways isolate supply before wiring.\u003c\/strong\u003e Current transformers (CTs) are required and \u003cstrong\u003esold separately\u003c\/strong\u003e — one CT per phase. Do not apply power until CTs are correctly fitted and CT leads are fully connected.\n  \u003c\/div\u003e\n\n  \u003c!-- ── AMBER COMPATIBILITY CALLOUT ───────────────────────────────── --\u003e\n  \u003cdiv style=\"border-left:4px solid #f59e0b;background:#fff8e1;padding:10px 16px;margin-bottom:22px;border-radius:0 6px 6px 0;\"\u003e\n    \u003cstrong style=\"color:#b45309;\"\u003e⚡ Compatibility \u0026amp; CT Notice\u003c\/strong\u003e — This meter is \u003cstrong\u003ecompatible with SolarEdge inverters and the SolarEdge Control and Communication Gateway only\u003c\/strong\u003e. It is not compatible with inverters from other manufacturers. \u003cstrong\u003eCurrent transformers must be ordered separately\u003c\/strong\u003e — available ratings: 100 A (SECT-SPL-100A-A), 250 A (SECT-SPL-250A-A), and 1000 A (SECT-SPL-1000A-A). Specify K2 on project documentation when export limitation is required.\n  \u003c\/div\u003e\n\n  \u003c!-- ── TECH SPEC TABLE ────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Technical Specifications\n  \u003c\/div\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:22px;font-size:14px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;width:45%;border-bottom:1px solid #c8e6e3;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSolarEdge Technologies\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSE-WND-3Y400-MB-K2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eNominal Voltage — Line to Neutral\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\u003cstrong\u003e230 Vac\u003c\/strong\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eNominal Voltage — Line to Line\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\u003cstrong\u003e400 Vac\u003c\/strong\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eOperating Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e184–264 Vac (L-N) \/ 320–460 Vac (L-L)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eAC Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e48–62 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eGrids Supported\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSingle phase (L \/ N \/ PE) \u0026amp; three phase (L1 \/ L2 \/ L3 \/ N \/ PE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1.8 W (typical)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eCommunication Interface\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\u003cstrong\u003eRS485 Modbus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eResponse Time\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e≤ 1 second\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eDefault Modbus Device ID\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eRS485 Line Termination\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e120 Ω\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eAccuracy (@ 25°C, PF: 1)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003e±1.0%\u003c\/strong\u003e across 1%–100% of rated CT current\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eDimensions (H × W × D)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e85 × 153 × 38 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e310 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eEnclosure\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eHigh-impact ABS \/ ABS-PC plastic, UL 94V-0 \/ IEC FV-0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eMounting\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eDIN rail or wall mount\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–40°C to +75°C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e5–90% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eIndoor; outdoor when installed in a suitable outdoor enclosure\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eExport Limitation Standard\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003eEngineering Recommendation G100 Issue 1 Amendment 1 2017\u003c\/strong\u003e (ENA, UK)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eSafety Standard\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eIEC 61010-1 (3rd Edition)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eEmissions\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eFCC Part 15 Class B, CISPR11:2009 Class B\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eWiring — AC\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1.3–2.0 mm diameter (16–12 AWG), 600 V stranded\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eWiring — RS485\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eMin. 3-wire shielded twisted pair, 0.2–1 mm² (24–18 AWG); CAT5 acceptable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;\"\u003eWarranty\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;\"\u003e\u003cstrong\u003e5 years\u003c\/strong\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- ── CT ACCESSORIES TABLE ───────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Compatible Current Transformers (sold separately — one per phase)\n  \u003c\/div\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:22px;font-size:14px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background:#005c54;color:#fff;\"\u003e\n        \u003cth style=\"padding:9px 14px;text-align:left;\"\u003eModel\u003c\/th\u003e\n        \u003cth style=\"padding:9px 14px;text-align:left;\"\u003eRated RMS Current\u003c\/th\u003e\n        \u003cth style=\"padding:9px 14px;text-align:left;\"\u003eInternal \/ External Dimensions\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSECT-SPL-100A-A\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\u003cstrong\u003e100 A\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e16 × 16 mm \/ 44 × 31 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSECT-SPL-250A-A\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\u003cstrong\u003e250 A\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e24 × 25 mm \/ 46.2 × 65.4 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;\"\u003eSECT-SPL-1000A-A\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;\"\u003e\u003cstrong\u003e1000 A\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;\"\u003e52 × 52 mm \/ 120 × 125 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- ── FAQ ────────────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Frequently Asked Questions\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #c8e6e3;border-top:none;border-radius:0 0 6px 6px;margin-bottom:8px;\"\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eWhy is the K2 version required for export limitation?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eThe \u003cstrong\u003eK2 designation confirms compliance with UK Engineering Recommendation G100\u003c\/strong\u003e (Issue 1 Amendment 1, 2017), which is the standard that Distribution Network Operators (DNOs) in Great Britain require for active export limitation on solar PV systems. If your DNO has issued a G100 connection agreement with an export limit, you must use the K2 meter. Earlier variants of the WND meter do not carry this certification and will not satisfy DNO requirements.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#fff;\"\u003eWhere is the meter installed — grid side or inverter side?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eFor \u003cstrong\u003eexport limitation (G100)\u003c\/strong\u003e, the meter must be installed at the \u003cstrong\u003egrid connection point\u003c\/strong\u003e (i.e. the main incomer, between the grid and the consumer unit \/ inverter). For consumption monitoring only, it can be installed on the main load circuit. \u003cstrong\u003eOne CT per phase\u003c\/strong\u003e is required — three CTs for a three-phase installation, one CT for single-phase. CT lead length is 2.4 m; if longer RS485 cable runs are needed, use shielded twisted pair over 10 m.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eWhich CT rating should I choose?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eSelect the CT based on the \u003cstrong\u003emaximum rated current of the supply fuse or main incomer\u003c\/strong\u003e at the installation. For residential properties with a 100 A supply, use \u003cstrong\u003eSECT-SPL-100A-A\u003c\/strong\u003e. For commercial properties with higher demand, use \u003cstrong\u003eSECT-SPL-250A-A\u003c\/strong\u003e or \u003cstrong\u003eSECT-SPL-1000A-A\u003c\/strong\u003e accordingly. Always choose the CT that matches or exceeds the maximum expected current — undersizing the CT will cause the reading to clip and may invalidate the G100 compliance.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#fff;\"\u003eHow does the meter connect to the SolarEdge inverter?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eThe meter connects via \u003cstrong\u003eRS485 (Modbus RTU)\u003c\/strong\u003e to the inverter's RS485 port. Wiring is a minimum 3-wire shielded twisted pair (0.2–1 mm²); CAT5 cable is acceptable for runs up to approximately 10 m indoors. For runs over 10 m in areas with lightning risk, external surge protection is recommended. The meter's default Modbus device ID is 2 and the RS485 termination is set to 120 Ω. Multiple meters or inverters can be daisy-chained on the same RS485 bus using the inverter's second RS485 port or a Commercial Gateway.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":64053020361053,"sku":"SE-WND-3Y400-MB-K2","price":130.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SolarEdge230-400VEnergyMeterwithModbusConnection.webp?v=1775019658"},{"product_id":"solaredge-split-core-current-transformer-for-energy-meter-100a-250a-1000a","title":"SolarEdge Split-Core Current Transformer for Energy Meter — 100A \/ 250A \/ 1000A","description":"\u003c!-- SEO Product Name: SolarEdge Split-Core Current Transformer for Energy Meter — 100A \/ 250A \/ 1000A (SE-CT-SPL-100A-A \/ 250A-A \/ 1000A-A) --\u003e\n\u003cdiv style=\"font-size:16px;font-family:Arial,Helvetica,sans-serif;color:#1a1a1a;max-width:900px;margin:0 auto;line-height:1.6;\"\u003e\n\n  \u003c!-- ── INTRO ─────────────────────────────────────────────────────── --\u003e\n  \u003cp style=\"margin:0 0 18px;\"\u003e\n    SolarEdge \u003cstrong\u003eSplit-Core Current Transformers (CTs)\u003c\/strong\u003e are the required accessory for the SolarEdge Energy Meter with Modbus Connection (SE-WND-3Y400-MB-K2). They provide a \u003cstrong\u003esimple, non-intrusive way to measure current flow\u003c\/strong\u003e on each phase without disconnecting existing cables — the split-core design clamps around the live conductor. Available in \u003cstrong\u003e100 A, 250 A, and 1000 A\u003c\/strong\u003e ratings to cover residential and commercial supply sizes. Each CT outputs \u003cstrong\u003e333 mVac at rated current\u003c\/strong\u003e, achieving \u003cstrong\u003e±1% accuracy\u003c\/strong\u003e across the full 1%–100% of rated current range. \u003cstrong\u003eOne CT is required per phase\u003c\/strong\u003e — one for single-phase, three for three-phase installations.\n  \u003c\/p\u003e\n\n  \u003c!-- ── STAT STRIP ─────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin-bottom:20px;\"\u003e\n    \u003cdiv style=\"flex:1;min-width:120px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003eSplit-core\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eNo rewiring needed\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:120px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003e±1%\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eAccuracy\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:120px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003e333 mVac\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eOutput at rated current\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:120px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003e2.4 m\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eLead wire length\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── RED INSTALLER CALLOUT ─────────────────────────────────────── --\u003e\n  \u003cdiv style=\"border-left:4px solid #c0392b;background:#fff5f5;padding:10px 16px;margin-bottom:14px;border-radius:0 6px 6px 0;\"\u003e\n    \u003cstrong style=\"color:#c0392b;\"\u003e⚠ Installer Note\u003c\/strong\u003e — CTs must only be installed and wired by a qualified electrician. \u003cstrong\u003eNever open CT leads while energised.\u003c\/strong\u003e Connect CT wiring to the meter before applying power. The CT circuit must not be left open-circuited — always connect to the meter terminal or short the leads before removing from the meter.\n  \u003c\/div\u003e\n\n  \u003c!-- ── AMBER COMPATIBILITY CALLOUT ───────────────────────────────── --\u003e\n  \u003cdiv style=\"border-left:4px solid #f59e0b;background:#fff8e1;padding:10px 16px;margin-bottom:22px;border-radius:0 6px 6px 0;\"\u003e\n    \u003cstrong style=\"color:#b45309;\"\u003e⚡ Compatibility\u003c\/strong\u003e — Compatible with the \u003cstrong\u003eSolarEdge Energy Meter SE-WND-3Y400-MB-K2\u003c\/strong\u003e and SE-MTR-3Y-400V-A. The \u003cstrong\u003e100A CT (SE-CT-SPL-100A-A) is a 1:1 replacement\u003c\/strong\u003e for the discontinued 50A (SE-ACT-0750-50) and 70A (SE-CTML-0350-070) models. Not compatible with third-party energy meters.\n  \u003c\/div\u003e\n\n  \u003c!-- ── VARIANT COMPARISON TABLE ──────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Choose Your Variant\n  \u003c\/div\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:22px;font-size:14px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background:#005c54;color:#fff;\"\u003e\n        \u003cth style=\"padding:9px 14px;text-align:left;\"\u003eAttribute\u003c\/th\u003e\n        \u003cth style=\"padding:9px 14px;text-align:left;\"\u003e100 A\u003c\/th\u003e\n        \u003cth style=\"padding:9px 14px;text-align:left;\"\u003e250 A\u003c\/th\u003e\n        \u003cth style=\"padding:9px 14px;text-align:left;\"\u003e1000 A\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003ePart No\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSE-CT-SPL-100A-A\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSE-CT-SPL-250A-A\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSE-CT-SPL-1000A-A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eManufacturer MPN\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSECT-SPL-100A-A\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSECT-SPL-250A-A\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSECT-SPL-1000A-A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eRated RMS Current\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\u003cstrong\u003e100 A\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\u003cstrong\u003e250 A\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\u003cstrong\u003e1000 A\u003c\/strong\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eInternal aperture (A × B)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e16 × 16 mm\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e24 × 25 mm\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e52 × 52 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eExternal dimensions (C × D)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e44 × 31 mm\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e46.2 × 65.4 mm\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e120 × 125 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;\"\u003eTypical application\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;\"\u003eResidential (60–100 A main fuse)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;\"\u003eSmall commercial (up to 250 A incomer)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;\"\u003eLarge commercial \/ industrial busbars\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- ── TECH SPEC TABLE ────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Technical Specifications (all variants)\n  \u003c\/div\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:22px;font-size:14px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;width:45%;border-bottom:1px solid #c8e6e3;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSolarEdge Technologies\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eCT Type\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSplit-core (clamp design) — no conductor disconnection required\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eOutput Voltage (at rated current)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\u003cstrong\u003e333 mVac\u003c\/strong\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eAccuracy (1%–100% of rated current)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\u003cstrong\u003e±1%\u003c\/strong\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eAccuracy Standards\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eIEEE C57.13, IEC 60044-1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eGrid Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e50 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eLead Wire Length\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e2.4 m, twisted pair\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eBurden Resistor\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eBuilt-in — no shorting blocks needed\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eIndoor \/ Outdoor\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eIndoor use only\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eCompatible Meters\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSolarEdge SE-WND-3Y400-MB-K2, SE-MTR-3Y-400V-A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;\"\u003eQuantity Required\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;\"\u003e\n\u003cstrong\u003e1 per phase\u003c\/strong\u003e (1× single-phase; 3× three-phase)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- ── FAQ ────────────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Frequently Asked Questions\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #c8e6e3;border-top:none;border-radius:0 0 6px 6px;margin-bottom:8px;\"\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eWhich CT rating do I need?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eChoose a CT rated at or above the \u003cstrong\u003emaximum rated current of your main supply fuse or incomer MCB\/MCCB\u003c\/strong\u003e. For most UK residential properties with a 60–100 A main fuse, the \u003cstrong\u003e100 A CT (SE-CT-SPL-100A-A)\u003c\/strong\u003e is correct. For commercial premises with 101–250 A incomers use the \u003cstrong\u003e250 A\u003c\/strong\u003e; for large commercial or industrial sites with busbars over 250 A, use the \u003cstrong\u003e1000 A\u003c\/strong\u003e. Never fit a CT with a lower rating than the maximum possible current — it will saturate and give inaccurate readings.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#fff;\"\u003eWill the CT fit around my existing cable without disconnecting it?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eYes — the \u003cstrong\u003esplit-core (clamp) design\u003c\/strong\u003e opens and closes around the live conductor without breaking the circuit. Check the \u003cstrong\u003einternal aperture\u003c\/strong\u003e of your chosen CT against the outer diameter of the cable or busbar it needs to clamp around: 16×16 mm (100A), 24×25 mm (250A), or 52×52 mm (1000A). If the cable OD is borderline, use the next size up. The CT must be clamped on a \u003cstrong\u003esingle-core conductor only\u003c\/strong\u003e — never clamp around a multicore cable or the readings will cancel out.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eIs the 100A CT backward-compatible with older 50A and 70A models?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eYes — SolarEdge updated the CT range and the \u003cstrong\u003e100A SECT-SPL-100A-A is a direct 1:1 replacement\u003c\/strong\u003e for the discontinued 50A (SE-ACT-0750-50) and 70A (SE-CTML-0350-070) CTs. The meter firmware automatically detects the CT rating, so no reconfiguration is required when replacing older models on existing installations.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"SolarEdge","offers":[{"title":"100A","offer_id":64053115060573,"sku":"SECT-SPL-100A-A","price":29.0,"currency_code":"GBP","in_stock":true},{"title":"250A","offer_id":64053115093341,"sku":"SECT-SPL-250A-A","price":33.0,"currency_code":"GBP","in_stock":true},{"title":"1000A","offer_id":64053115126109,"sku":"SECT-SPL-1000A-A","price":67.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Split-CoreCurrentTransformerforSolarEdgeEnergyMeterswithModbusConnection.jpg?v=1775020778"},{"product_id":"belcom-double-pair-rs485-cable-4-core-lszh-priced-per-metre","title":"Belcom Double Pair RS485 Cable 4-Core LSZH — Priced per Metre","description":"\u003cdiv style=\"font-size:16px;font-family:Arial,Helvetica,sans-serif;color:#1a1a1a;max-width:900px;margin:0 auto;line-height:1.6;\"\u003e\n\n  \u003c!-- ── INTRO ─────────────────────────────────────────────────────── --\u003e\n  \u003cp style=\"margin:0 0 18px;\"\u003e\n    The \u003cstrong\u003eBelcom 4402P2454\u003c\/strong\u003e is a \u003cstrong\u003edouble-pair, 4-core, 24 AWG shielded RS485 data cable\u003c\/strong\u003e designed for reliable Modbus and RS485 communication in solar PV, building automation, and industrial control applications. The \u003cstrong\u003e4 cores are twisted as two pairs\u003c\/strong\u003e — ideal for RS485 A\/B plus ground and shield drain — with an \u003cstrong\u003eoverall aluminium\/polyester tape screen and 80% tinned copper braid\u003c\/strong\u003e for superior noise rejection. The \u003cstrong\u003eLSZH FireFighter® UV-stable outer jacket\u003c\/strong\u003e makes it suitable for both indoor and exposed outdoor runs. Sold and priced \u003cstrong\u003eper metre\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n  \u003c!-- ── STAT STRIP ─────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin-bottom:20px;\"\u003e\n    \u003cdiv style=\"flex:1;min-width:120px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003e4-core\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003e2 twisted pairs\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:120px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003e24 AWG\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eTinned copper\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:120px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003eDouble shielded\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eFoil + 80% braid\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:120px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003eLSZH\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eFireFighter® UV jacket\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── TEAL INFO CALLOUT ──────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"border-left:4px solid #008377CF;background:#e6f4f3;padding:10px 16px;margin-bottom:22px;border-radius:0 6px 6px 0;\"\u003e\n    \u003cstrong style=\"color:#005c54;\"\u003eℹ Priced per metre\u003c\/strong\u003e — Enter the quantity in metres at checkout. The SolarEdge installation guide specifies a minimum 3-wire shielded twisted pair for RS485 wiring (0.2–1 mm² \/ 24–18 AWG); this cable meets and exceeds that specification. Maximum recommended RS485 bus length: \u003cstrong\u003e1200 m\u003c\/strong\u003e.\n  \u003c\/div\u003e\n\n  \u003c!-- ── SPEC TABLE ─────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Product Specifications\n  \u003c\/div\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:22px;font-size:14px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;width:42%;border-bottom:1px solid #c8e6e3;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eBelcom Cables\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e4402P2454\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eConductor\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eStranded tinned copper wire, \u003cstrong\u003e24 AWG\u003c\/strong\u003e\n\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eInsulation\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003ePolyethylene (PE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eFormation\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003e4 cores as two twisted pairs\u003c\/strong\u003e: BLUE\/white – WHITE\/blue \u0026amp; ORANGE\/white – WHITE\/orange\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eScreen\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eOverall aluminium\/polyester tape\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eDrain Wire\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eStranded tinned copper, 24 AWG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eBraid\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eTinned copper wire braid, \u003cstrong\u003e80% coverage\u003c\/strong\u003e\n\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eOuter Jacket\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003eLSZH FireFighter®\u003c\/strong\u003e, UV-stable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eApplications\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eRS485 \/ Modbus RTU — SolarEdge inverter \u0026amp; meter wiring, BACnet, building automation, industrial control\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 14px;font-weight:600;\"\u003ePricing Unit\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 14px;\"\u003e\u003cstrong\u003ePer metre\u003c\/strong\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- ── FAQ ────────────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Frequently Asked Questions\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #c8e6e3;border-top:none;border-radius:0 0 6px 6px;margin-bottom:8px;\"\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eIs this cable suitable for wiring a SolarEdge energy meter to an inverter?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eYes — this cable fully meets the SolarEdge RS485 wiring specification: minimum 3-wire shielded twisted pair, 0.2–1 mm² (24–18 AWG). The 4-core format gives you a dedicated pair for RS485 A and B, plus extra cores for GND and shield termination. \u003cstrong\u003eUse one pair for RS485 A\/B and terminate the screen drain wire at one end only\u003c\/strong\u003e (typically at the inverter end) to avoid ground loops.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#fff;\"\u003eWhy does it need double shielding (foil + braid)?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eIn solar PV installations, RS485 cables often run near DC cables, inverters, and switching equipment that generate electrical noise. The \u003cstrong\u003ealuminium\/polyester foil provides 100% coverage\u003c\/strong\u003e against high-frequency interference, while the \u003cstrong\u003e80% tinned copper braid adds mechanical protection and improves low-frequency shielding\u003c\/strong\u003e. Together they ensure reliable communication over long runs in electrically noisy environments.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eHow much cable do I need for a typical SolarEdge meter installation?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eThe CT lead wires are 2.4 m long, so the meter should ideally be mounted within 2.4 m of the main incomer. Allow enough RS485 cable to run from the meter terminal to the inverter RS485 port — typically \u003cstrong\u003e3–10 m\u003c\/strong\u003e for a standard domestic installation where the consumer unit and inverter are in the same area, or more for commercial sites where equipment is spread across multiple rooms. \u003cstrong\u003eSolarEdge recommends external surge protection for runs over 10 m\u003c\/strong\u003e in lightning-risk areas.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Belcom","offers":[{"title":"Default Title","offer_id":64053130854749,"sku":"4402P2454","price":2.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/BelcomDoublePairRS485Cable4-CoreLSZH4402P2454_c782f4e0-12cb-4949-b21a-79112d7d7611.webp?v=1775022697"},{"product_id":"emlite-emp1-aznet-emp1-av-net-3-phase-bi-directional-generation-meter-100a-1000-pulse-kwh","title":"Emlite EMP1-AZNET EMP1.av NET 3-Phase Bi-Directional Generation Meter 100A 1000 Pulse kWh","description":"\u003c!-- SEO Product Name: Emlite EMP1-AZNET EMP1.av NET 3-Phase Bi-Directional Generation Meter 100A 1000 Pulse kWh — Three Phase Solar Battery Storage Hybrid MCS SEG --\u003e\n\u003cdiv style=\"font-size:16px;font-family:Arial,Helvetica,sans-serif;color:#1a1a1a;max-width:900px;margin:0 auto;line-height:1.6;\"\u003e\n\n  \u003c!-- ── INTRO ─────────────────────────────────────────────────────── --\u003e\n  \u003cp style=\"margin:0 0 18px;\"\u003e\n    The \u003cstrong\u003eEmlite EMP1-AZNET (EMP1.av NET)\u003c\/strong\u003e is a \u003cstrong\u003ethree-phase, direct-connect 100A per phase MID-approved bi-directional electricity meter with 1000 pulse\/kWh output\u003c\/strong\u003e, factory-configured to display \u003cstrong\u003eImport, Export, and NET registers\u003c\/strong\u003e — with NET as the primary reading for MCS and SEG compliance. It is the correct generation meter for \u003cstrong\u003ethree-phase solar PV installations co-located with DC-coupled or hybrid battery storage\u003c\/strong\u003e, where the MCS and Ofgem SEG co-location guidance (SEG v6.1) requires a NET export figure rather than a gross generation reading. Where a standard generation meter counts all kWh produced by the array (including energy used to charge the battery from the grid), the EMP1-AZNET's NET register deducts grid import from export — delivering the true net amount of energy that left the property. Required for battery retrofits on existing three-phase PV systems, and for new three-phase hybrid inverter installations from the outset. Fully \u003cstrong\u003eMID approved to Class B (1% accuracy, EN 50470-1\/3) for active energy\u003c\/strong\u003e and \u003cstrong\u003eClass 2 (IEC 62053-23) for reactive energy\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n  \u003c!-- ── TEAL NET CALLOUT ───────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"border-left:4px solid #008377CF;background:#e6f4f3;padding:10px 16px;margin-bottom:22px;border-radius:0 6px 6px 0;\"\u003e\n    \u003cstrong style=\"color:#005c54;\"\u003eℹ EMP1-AZNET vs EMP1-AZ — Choosing the Right Three-Phase Meter\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eEMP1-AZ (standard bi-directional):\u003c\/strong\u003e Suitable for three-phase PV-only installations or where basic import and export registers are sufficient. Shows Import and Export with the NET accessible on the display cycle.\u003cbr\u003e\u003cbr\u003e\n    \u003cstrong\u003eEMP1-AZNET (this meter — NET configured):\u003c\/strong\u003e Required where the \u003cstrong\u003eNET figure is the primary compliance reading\u003c\/strong\u003e — specifically for \u003cstrong\u003eDC-coupled storage, hybrid inverters, and any three-phase installation co-locating battery storage under Ofgem's SEG v6.1 co-location guidance\u003c\/strong\u003e. The NET register (Export minus Import) ensures grid-charged battery discharge is not counted as solar generation in the official kWh figure submitted to MCS and the SEG energy supplier. This meter is also used when replacing a legacy generation meter on an existing three-phase PV system where battery storage has been retrofitted.\n  \u003c\/div\u003e\n\n  \u003c!-- ── RED INSTALLER CALLOUT ─────────────────────────────────────── --\u003e\n  \u003cdiv style=\"border-left:4px solid #c0392b;background:#fff5f5;padding:10px 16px;margin-bottom:22px;border-radius:0 6px 6px 0;\"\u003e\n    \u003cstrong style=\"color:#c0392b;\"\u003e⚠ Qualified Installation Required\u003c\/strong\u003e — Must be installed by a \u003cstrong\u003equalified electrician\u003c\/strong\u003e in accordance with BS 7671, Part P of the Building Regulations, and the Emlite EMP1 installation manual. The meter must be installed correctly to measure the generation circuit accurately — incorrect connection on a three-phase system will result in erroneous NET figures. Verify connection polarity and phase assignment before commissioning. The meter is \u003cstrong\u003enot fitted with a disconnection switch\u003c\/strong\u003e — a suitable isolator must be provided.\n  \u003c\/div\u003e\n\n  \u003c!-- ── STAT STRIP ─────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin-bottom:20px;\"\u003e\n    \u003cdiv style=\"flex:1;min-width:90px;background:#008377CF;color:#fff;border-radius:6px;padding:11px 8px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:17px;font-weight:700;\"\u003e3-phase\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003e100A per phase\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:90px;background:#008377CF;color:#fff;border-radius:6px;padding:11px 8px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:17px;font-weight:700;\"\u003eNET configured\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eImport · Export · NET\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:90px;background:#008377CF;color:#fff;border-radius:6px;padding:11px 8px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:17px;font-weight:700;\"\u003eMID Class B\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003e1% accuracy\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:90px;background:#008377CF;color:#fff;border-radius:6px;padding:11px 8px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:17px;font-weight:700;\"\u003e1000 pulse\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eper kWh\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:90px;background:#008377CF;color:#fff;border-radius:6px;padding:11px 8px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:17px;font-weight:700;\"\u003eIP54\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eIngress protected\u003c\/div\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── FEATURES GRID ──────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003eFeatures \u0026amp; Benefits\u003c\/div\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(255px,1fr));gap:12px;background:#e6f4f3;padding:14px;border-radius:0 0 6px 6px;margin-bottom:22px;\"\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ NET Register — The Critical Figure for Battery Co-Location\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe \u003cstrong\u003eNET reading (Export minus Import)\u003c\/strong\u003e is the figure that MCS and Ofgem's SEG v6.1 co-location guidance require when a battery is present in the system. Without a NET meter, a standard generation meter would count grid energy used to charge the battery as solar generation — inflating the kWh figures submitted for MCS commissioning and SEG payments. The EMP1-AZNET's NET register ensures \u003cstrong\u003eonly the genuine surplus that left the property counts\u003c\/strong\u003e. All three registers — Import, Export, and NET — auto-cycle on the LCD and are individually readable via the optical port for reporting and commissioning documentation.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ MID Approved — Legal for MCS \u0026amp; SEG Compliance\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003e\n\u003cstrong\u003eMID (Measuring Instruments Directive 2004\/22\/EC) approval\u003c\/strong\u003e is the legal requirement for generation and export meters used in UK MCS commissioning and SEG energy supplier registration. Without a MID-approved meter, an installation cannot be officially signed off and the homeowner cannot register for SEG payments. The EMP1-AZNET carries full MID approval to \u003cstrong\u003eClass B (1% accuracy, EN 50470-1\/3)\u003c\/strong\u003e for active energy, satisfying all DNO and MCS submission requirements for three-phase solar plus storage systems.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ 4-Quadrant Energy Measurement Across All 3 Phases\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe EMP1-AZNET measures \u003cstrong\u003e4-quadrant active energy across all three phases simultaneously\u003c\/strong\u003e — tracking import and export in both forward and reverse directions. This correctly handles mixed-direction energy flow, which occurs in three-phase battery systems where different phases may have different generation and load profiles at any given moment. Separate registers for each quadrant are stored and accessible via the optical port. Optional power quality data (per-phase voltage, current, and power) is also available for system performance analysis and G99 compliance monitoring.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ 1000 Pulse\/kWh — Opto-Isolated Output\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe \u003cstrong\u003e1000 pulse per kWh opto-isolated output\u003c\/strong\u003e (IEC 62053-31, conforming to class A) on the auxiliary terminals feeds real-time energy data into energy management systems, BMS, AMR data loggers, and inverter monitoring platforms. Each pulse represents 1Wh of energy — at 1000 pulses\/kWh the resolution is fine enough for accurate sub-hourly monitoring of net export. Compatible with most commercial three-phase inverter and monitoring platforms that accept an S0 or open-collector pulse input. The opto-isolated output prevents ground-loop issues when connecting to third-party equipment.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ 100A Per Phase — Direct Connected — 25mm² Terminals\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003e\n\u003cstrong\u003eDirect-connect (whole current) meter rated at 100A per phase\u003c\/strong\u003e — no external current transformers required, covering three-phase solar PV and battery installations up to approximately 69kW combined at 230V per phase. \u003cstrong\u003eDIN43857-Part 2\u003c\/strong\u003e terminal arrangement with 150mm fixing centres and solid brass terminals with 8.2mm cable entry accepting \u003cstrong\u003eup to 25mm² meter tails\u003c\/strong\u003e. Main supply terminals numbered 1\/3 (L1), 4\/6 (L2), 7\/9 (L3), 10\/12 (N) with numbered test terminals 2, 5, 8, 11. The meter is not fitted with a supply disconnection switch.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Optical Port — Tamper Resistant — IP54\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eAn \u003cstrong\u003eoptical communications port\u003c\/strong\u003e (IEC 629056-21) enables electronic meter reading using a standard probe — useful for commissioning verification and quarterly remote read submissions. The meter is tamper resistant and suitable for both new installations and replacement of legacy generation meters on existing three-phase PV systems where battery storage is being retrofitted. \u003cstrong\u003eIP54\u003c\/strong\u003e ingress protection (BS EN 60529) — protected against dust deposits and water splashing from any direction — suitable for meter board and distribution board installations. Operational from \u003cstrong\u003e–25°C to +55°C\u003c\/strong\u003e.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- ── SPEC TABLE ─────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003eTechnical Specifications — Emlite EMP1-AZNET (EMP1.av NET)\u003c\/div\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:22px;font-size:14px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;width:44%;border-bottom:1px solid #c8e6e3;\"\u003eManufacturer \/ MPN\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eEmlite — \u003cstrong\u003eEMP1-AZNET\u003c\/strong\u003e (EMP1.av NET)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003ePhase\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eThree phase (3×230V \/ 400V, four-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eRegisters Displayed\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003eImport · Export · NET\u003c\/strong\u003e (Export minus Import) — auto-cycling LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eEnergy Measurement\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e4-quadrant active energy (all 3 phases); reactive energy\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e3 × 230V (phase-to-neutral); 400V withstand continuously\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e50Hz ± 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eReference \/ Max Current\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eIref 5–20A per phase; \u003cstrong\u003eImax 100A per phase\u003c\/strong\u003e — direct connected\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eAccuracy — Active Energy\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003eClass B (1%)\u003c\/strong\u003e — EN 50470-1\/3; fully MID approved\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eAccuracy — Reactive Energy\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eClass 2 — IEC 62053-23\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003ePulse Output\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003e1000 pulses\/kWh\u003c\/strong\u003e — opto-isolated transistor, IEC 62053-31 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e8-digit LCD with phase indicators and energy direction symbol\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eOptical Port\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eIEC 629056-21\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eTerminal Standard\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eDIN43857-Part 2; 150 ± 1mm fixing centres; 8.2mm solid brass; 25mm² capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eIP Rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003eIP54\u003c\/strong\u003e (BS EN 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;\"\u003e170 × 200.2 × 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- ── FAQ ────────────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #c8e6e3;border-top:none;border-radius:0 0 6px 6px;margin-bottom:8px;\"\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eWhy is a NET meter required for three-phase solar systems with battery storage?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eWhen a battery is present in a solar PV system, the inverter can \u003cstrong\u003echarge the battery from the grid\u003c\/strong\u003e — particularly at night on cheap-rate tariffs such as Octopus Go or Economy 7. If a standard generation meter (measuring only outbound energy from the array) were used, grid energy discharged from the battery to the home would not be counted. However, a simple export meter (measuring only outbound energy from the property) could \u003cstrong\u003ecount grid-charged battery discharge as solar export\u003c\/strong\u003e, inflating the export figure and creating false SEG payment claims. The NET meter solves this: it measures both what leaves the property (export) and what enters from the grid (import), and deducts import from export to produce a NET figure — the genuine solar energy that left the building, uncontaminated by any grid-charged battery round-trip. Ofgem's SEG co-location guidance (v6.1) mandates this approach for co-located storage under the Smart Export Guarantee.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#fff;\"\u003eWhat is the difference between the EMP1-AZNET and the EMP1-AZ?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eBoth the EMP1-AZ and the EMP1-AZNET are three-phase bi-directional meters on the Emlite EMP1 platform, with identical hardware, accuracy class, and physical specifications. The difference is in \u003cstrong\u003econfiguration and intended application\u003c\/strong\u003e. The \u003cstrong\u003eEMP1-AZ\u003c\/strong\u003e is the standard bi-directional variant where all registers (Import, Export, NET) are available but the meter is not specifically configured for NET-primary display — suitable for general three-phase generation metering and monitoring. The \u003cstrong\u003eEMP1-AZNET\u003c\/strong\u003e is factory-configured with the \u003cstrong\u003eNET register as the primary compliance reading\u003c\/strong\u003e and is supplied specifically for battery co-location compliance under MCS and SEG v6.1. If your installation includes battery storage and the DNO or MCS submission explicitly requires a NET meter, specify the EMP1-AZNET. If the application is a PV-only three-phase system without storage, the EMP1-AZ is the appropriate choice.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eCan I use this meter to replace an existing generation meter when retrofitting battery storage?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eYes — the EMP1-AZNET is specifically recommended for \u003cstrong\u003ebattery storage retrofits on existing three-phase solar PV installations\u003c\/strong\u003e. When battery storage is added to an existing PV system that already has a standard (non-bi-directional) generation meter, the generation meter must be replaced with a NET meter to comply with the updated MCS and SEG co-location requirements. The EMP1-AZNET can be installed in place of the existing generation meter — same DIN43857 terminal layout and same installation footprint as the standard EMP1 meters means the swap is straightforward. The MCS installer will need to update the MCS certificate to reflect the new meter serial number.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#fff;\"\u003eWhat reading do I give my energy supplier for SEG payments?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eFor systems with battery storage under the Smart Export Guarantee, you should provide the \u003cstrong\u003eNET register reading\u003c\/strong\u003e to your energy supplier — not the Import or Export registers. The NET figure (Export minus Import, as accumulated over the period since the last reading) represents the genuine net amount of energy your property exported to the grid over the billing period. Some energy suppliers read the meter remotely via smart meter infrastructure; others require you to submit meter readings. When submitting, clearly identify it as the \"NET\" register reading from the generation meter — not the house import meter — to avoid confusion. Check your specific SEG tariff agreement for the reading submission process.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eIs this meter suitable for large commercial three-phase solar installations?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eYes — the EMP1-AZNET is suitable for \u003cstrong\u003ethree-phase commercial solar PV and battery storage installations\u003c\/strong\u003e up to 100A per phase. At 3×230V, this covers combined installations up to approximately 69kW, encompassing the majority of commercial rooftop solar plus storage systems requiring a direct-connect NET meter. For very large commercial systems where per-phase currents exceed 100A, a CT-metered solution with appropriate current transformers would be required. The MID Class B approval applies to all commercial billing and official reporting contexts, and the meter is compatible with commercial energy management systems via the opto-isolated pulse output and optical port.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#fff;\"\u003eCan the pulse output be connected to my inverter monitoring platform?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eYes — the \u003cstrong\u003e1000 pulse\/kWh opto-isolated output\u003c\/strong\u003e (IEC 62053-31 Class A) connects to energy management systems, BMS, AMR data loggers, and inverter monitoring platforms that accept an S0 or open-collector pulse input. Most commercial three-phase inverter monitoring platforms (Solis, GivEnergy, SolarEdge, Huawei, Fox ESS, etc.) accept a pulse input for independent generation or NET export verification. The output polarity must be observed — consult your monitoring platform's wiring diagram for the correct terminal orientation. The optical port (IEC 629056-21) provides a secondary communications route for electronic meter reading without requiring a pulse input on the monitoring device.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Emlite","offers":[{"title":"Default Title","offer_id":64181175583069,"sku":"EMP1-AZNET","price":133.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/EmLiteEMP1ThreePhaseSolarPVImportExportMeter.webp?v=1760365398"},{"product_id":"sunsynk-wireless-ct-clamp-sunct-rs03-acure-inverter","title":"Sunsynk Wireless CT Clamp SUNCT-RS03 Acure Inverter","description":"\u003cdiv style=\"font-size:16px;font-family:Arial,Helvetica,sans-serif;color:#222;max-width:900px;margin:0 auto;line-height:1.65;\"\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eSunsynk Wireless CT (SUNCT-RS03)\u003c\/strong\u003e is a \u003cstrong\u003eLoRa-enabled current transformer clamp\u003c\/strong\u003e designed for the Sunsynk Acure inverter range. Traditional wired CT clamps must be cabled all the way back to the inverter — a route that can cross rooms, floors, and finished walls. The SUNCT-RS03 eliminates this entirely: clip the sensor around the incomer cable at your consumer unit, and it \u003cstrong\u003etransmits grid import\/export data wirelessly to the Acure\u003c\/strong\u003e over the inverter's built-in LoRa radio, \u003cstrong\u003etested to 200 metres\u003c\/strong\u003e. Up to \u003cstrong\u003etwo wireless CTs can be paired per Acure inverter\u003c\/strong\u003e. The result is a \u003cstrong\u003ecleaner, faster installation\u003c\/strong\u003e — no CT cable routes to plan, no conduit, no surface trunking.\u003c\/p\u003e\n\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;margin:20px 0;\"\u003e\n  \u003cdiv style=\"flex:1;min-width:130px;background:#008377CF;color:#fff;border-radius:8px;padding:16px;text-align:center;\"\u003e\n    \u003cdiv style=\"font-size:24px;font-weight:700;\"\u003e200 m\u003c\/div\u003e\n    \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003eTested LoRa Range\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"flex:1;min-width:130px;background:#008377CF;color:#fff;border-radius:8px;padding:16px;text-align:center;\"\u003e\n    \u003cdiv style=\"font-size:24px;font-weight:700;\"\u003e2 max\u003c\/div\u003e\n    \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003ePer Acure Inverter\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"flex:1;min-width:130px;background:#008377CF;color:#fff;border-radius:8px;padding:16px;text-align:center;\"\u003e\n    \u003cdiv style=\"font-size:24px;font-weight:700;\"\u003eZero\u003c\/div\u003e\n    \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003eCT Signal Cables\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"flex:1;min-width:130px;background:#008377CF;color:#fff;border-radius:8px;padding:16px;text-align:center;\"\u003e\n    \u003cdiv style=\"font-size:24px;font-weight:700;\"\u003eAcure\u003c\/div\u003e\n    \u003cdiv style=\"font-size:12px;margin-top:4px;\"\u003eCompatible Range Only\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"border-left:4px solid #c0392b;background:#fff5f5;padding:14px 16px;border-radius:6px;margin:16px 0;\"\u003e\n  \u003cstrong style=\"color:#c0392b;\"\u003e⚠ Compatibility \u0026amp; Installation:\u003c\/strong\u003e The SUNCT-RS03 is \u003cstrong\u003eonly compatible with Sunsynk Acure series inverters\u003c\/strong\u003e (SunC1 and SunC2). It will not pair with other Sunsynk models. The CT clamp must be fitted on the \u003cstrong\u003elive conductor of the grid incomer\u003c\/strong\u003e — the cable between the meter\/cutout and the consumer unit. \u003cstrong\u003eDirectional arrow on the sensor must point toward the load (consumer unit) side.\u003c\/strong\u003e Never fit on neutral or earth conductors.\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:4px solid #e67e22;background:#fffbf0;padding:14px 16px;border-radius:6px;margin:16px 0;\"\u003e\n  \u003cstrong style=\"color:#e67e22;\"\u003e⚡ Zero-Export Use:\u003c\/strong\u003e For \u003cstrong\u003ezero-export limiting\u003c\/strong\u003e, the CT must measure the \u003cstrong\u003egrid incomer\u003c\/strong\u003e (not a sub-circuit). An incorrectly positioned CT will feed the inverter erroneous import\/export values, causing incorrect throttling or unwanted grid export.\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:4px solid #008377;background:#e6f4f3;padding:14px 16px;border-radius:6px;margin:16px 0;\"\u003e\n  \u003cstrong style=\"color:#005c54;\"\u003eℹ Installation Benefit:\u003c\/strong\u003e The SUNCT-RS03 is especially valuable where the \u003cstrong\u003einverter and consumer unit are in different locations\u003c\/strong\u003e — for example, a garage-mounted inverter with the house consumer unit in a hallway. No CT signal cable route is required between the two locations.\n\u003c\/div\u003e\n\n\u003cp style=\"color:#005c54;font-weight:700;font-size:15px;margin-top:24px;\"\u003eKey Features\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;margin:20px 0;\"\u003e\n\n  \u003cdiv style=\"flex:1;min-width:240px;border:1px solid #dde8e7;border-radius:8px;padding:18px;\"\u003e\n    \u003cdiv style=\"color:#008377;font-weight:700;font-size:15px;margin-bottom:8px;\"\u003eLoRa Wireless Transmission\u003c\/div\u003e\n    \u003cdiv style=\"font-size:14px;line-height:1.6;color:#333;\"\u003eUses the \u003cstrong\u003esub-GHz LoRa band\u003c\/strong\u003e built into every Acure inverter — the same radio as the Smartlynk switch. LoRa penetrates concrete floors and masonry walls far more effectively than Wi-Fi or Bluetooth, sustaining reliable readings in electrically noisy environments.\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"flex:1;min-width:240px;border:1px solid #dde8e7;border-radius:8px;padding:18px;\"\u003e\n    \u003cdiv style=\"color:#005c54;font-weight:700;font-size:15px;margin-bottom:8px;\"\u003eBidirectional Grid Measurement\u003c\/div\u003e\n    \u003cdiv style=\"font-size:14px;line-height:1.6;color:#333;\"\u003eThe CT measures \u003cstrong\u003ebidirectional current on the grid incomer\u003c\/strong\u003e, giving the inverter real-time import and export data. This drives \u003cstrong\u003ezero-export limiting, self-consumption optimisation\u003c\/strong\u003e, and accurate energy accounting in Sunsynk Connect Pro.\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"flex:1;min-width:240px;border:1px solid #dde8e7;border-radius:8px;padding:18px;\"\u003e\n    \u003cdiv style=\"color:#008377;font-weight:700;font-size:15px;margin-bottom:8px;\"\u003eFaster, Cleaner Installations\u003c\/div\u003e\n    \u003cdiv style=\"font-size:14px;line-height:1.6;color:#333;\"\u003eEliminating the CT signal cable \u003cstrong\u003esaves significant installation time\u003c\/strong\u003e and avoids the need to route cable between meter position and inverter — particularly valuable in multi-storey or open-plan properties where chasing or surface trunking is unacceptable.\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"flex:1;min-width:240px;border:1px solid #dde8e7;border-radius:8px;padding:18px;\"\u003e\n    \u003cdiv style=\"color:#005c54;font-weight:700;font-size:15px;margin-bottom:8px;\"\u003eUp to Two CTs per Inverter\u003c\/div\u003e\n    \u003cdiv style=\"font-size:14px;line-height:1.6;color:#333;\"\u003eA single Acure supports \u003cstrong\u003etwo SUNCT-RS03 sensors simultaneously\u003c\/strong\u003e — useful where separate monitoring of an EV charge circuit or a sub-distribution board is required alongside the main incomer measurement.\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"flex:1;min-width:240px;border:1px solid #dde8e7;border-radius:8px;padding:18px;\"\u003e\n    \u003cdiv style=\"color:#008377;font-weight:700;font-size:15px;margin-bottom:8px;\"\u003eEnables Zero-Export Control\u003c\/div\u003e\n    \u003cdiv style=\"font-size:14px;line-height:1.6;color:#333;\"\u003eMany DNOs and private landowners require \u003cstrong\u003ezero export to the grid\u003c\/strong\u003e. The SUNCT-RS03 gives the Acure the real-time grid signal it needs to throttle inverter output and \u003cstrong\u003eprevent any net export\u003c\/strong\u003e, satisfying G99 conditions where export is not permitted.\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"flex:1;min-width:240px;border:1px solid #dde8e7;border-radius:8px;padding:18px;\"\u003e\n    \u003cdiv style=\"color:#005c54;font-weight:700;font-size:15px;margin-bottom:8px;\"\u003ePairs via Acure Touchscreen\u003c\/div\u003e\n    \u003cdiv style=\"font-size:14px;line-height:1.6;color:#333;\"\u003eRegistration is performed directly on the \u003cstrong\u003eAcure's colour touchscreen\u003c\/strong\u003e — no laptop or separate commissioning app is required on site. The sensor joins the inverter's LoRa network within seconds of pairing.\u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"overflow-x:auto;margin:24px 0;\"\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-family:inherit;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"2\" style=\"background:#005c54;color:#fff;padding:10px 12px;text-align:left;font-size:14px;\"\u003eTechnical Specifications\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377;color:#fff;font-weight:700;padding:8px 10px;font-size:13px;\"\u003eGENERAL\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#f7fafa;\"\u003e\n\u003ctd style=\"padding:7px 10px;font-weight:600;width:46%;font-size:13px;color:#333;border-bottom:1px solid #eee;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;font-size:13px;color:#444;border-bottom:1px solid #eee;\"\u003eSUNCT-RS03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:7px 10px;font-weight:600;font-size:13px;color:#333;border-bottom:1px solid #eee;\"\u003eCommunication Technology\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;font-size:13px;color:#444;border-bottom:1px solid #eee;\"\u003eLoRa (sub-GHz wireless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7fafa;\"\u003e\n\u003ctd style=\"padding:7px 10px;font-weight:600;font-size:13px;color:#333;border-bottom:1px solid #eee;\"\u003eTested Communication Range\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;font-size:13px;color:#444;border-bottom:1px solid #eee;\"\u003e200 m (line of sight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:7px 10px;font-weight:600;font-size:13px;color:#333;border-bottom:1px solid #eee;\"\u003eMax. Sensors per Acure Inverter\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;font-size:13px;color:#444;border-bottom:1px solid #eee;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7fafa;\"\u003e\n\u003ctd style=\"padding:7px 10px;font-weight:600;font-size:13px;color:#333;border-bottom:1px solid #eee;\"\u003eCompatible Inverters\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;font-size:13px;color:#444;border-bottom:1px solid #eee;\"\u003eSunsynk Acure Series only (SunC1 and SunC2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:7px 10px;font-weight:600;font-size:13px;color:#333;border-bottom:1px solid #eee;\"\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;font-size:13px;color:#444;border-bottom:1px solid #eee;\"\u003eBidirectional AC current (grid import and export)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7fafa;\"\u003e\n\u003ctd style=\"padding:7px 10px;font-weight:600;font-size:13px;color:#333;border-bottom:1px solid #eee;\"\u003eRecommended Installation Position\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;font-size:13px;color:#444;border-bottom:1px solid #eee;\"\u003eLive conductor of grid incomer (between meter and consumer unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:7px 10px;font-weight:600;font-size:13px;color:#333;border-bottom:1px solid #eee;\"\u003eSignal Cable to Inverter Required\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;font-size:13px;color:#444;border-bottom:1px solid #eee;\"\u003eNone — fully wireless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7fafa;\"\u003e\n\u003ctd style=\"padding:7px 10px;font-weight:600;font-size:13px;color:#333;border-bottom:1px solid #eee;\"\u003ePairing Method\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;font-size:13px;color:#444;border-bottom:1px solid #eee;\"\u003eVia Acure inverter colour touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:7px 10px;font-weight:600;font-size:13px;color:#333;border-bottom:1px solid #eee;\"\u003eWorks Alongside Smartlynk Switches?\u003c\/td\u003e\n\u003ctd style=\"padding:7px 10px;font-size:13px;color:#444;border-bottom:1px solid #eee;\"\u003eYes — shares the same Acure LoRa network (up to 2 CTs + 10 Smartlynks per inverter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin:24px 0;\"\u003e\n\u003cp style=\"font-size:15px;font-weight:700;color:#005c54;margin-bottom:12px;\"\u003eFrequently Asked Questions\u003c\/p\u003e\n\n\u003cdetails style=\"border:1px solid #dde8e7;border-radius:6px;margin-bottom:8px;\"\u003e\n  \u003csummary style=\"background:#008377;color:#fff;padding:12px 14px;font-weight:600;cursor:pointer;border-radius:5px;font-size:14px;\"\u003eIs a wired CT included with the Acure inverter?\u003c\/summary\u003e\n  \u003cdiv style=\"padding:14px 16px;font-size:14px;line-height:1.7;color:#333;\"\u003eThe Acure supports both wired and wireless CT connection. A wired CT is typically supplied with the inverter for standard installations. The SUNCT-RS03 is an \u003cstrong\u003eoptional wireless upgrade\u003c\/strong\u003e for situations where running a CT cable is impractical or undesirable.\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"border:1px solid #dde8e7;border-radius:6px;margin-bottom:8px;\"\u003e\n  \u003csummary style=\"background:#008377;color:#fff;padding:12px 14px;font-weight:600;cursor:pointer;border-radius:5px;font-size:14px;\"\u003eWhere exactly should the CT be fitted?\u003c\/summary\u003e\n  \u003cdiv style=\"padding:14px 16px;font-size:14px;line-height:1.7;color:#333;\"\u003eClip the SUNCT-RS03 around the \u003cstrong\u003elive conductor of the grid incomer\u003c\/strong\u003e — the cable entering the consumer unit from the meter or service cutout. Do not fit it on a neutral or earth conductor. Ensure the \u003cstrong\u003edirectional arrow on the sensor body points toward the load (consumer unit side)\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"border:1px solid #dde8e7;border-radius:6px;margin-bottom:8px;\"\u003e\n  \u003csummary style=\"background:#008377;color:#fff;padding:12px 14px;font-weight:600;cursor:pointer;border-radius:5px;font-size:14px;\"\u003eWill it work reliably through thick walls?\u003c\/summary\u003e\n  \u003cdiv style=\"padding:14px 16px;font-size:14px;line-height:1.7;color:#333;\"\u003eLoRa is specifically chosen for its \u003cstrong\u003ewall-penetrating capability\u003c\/strong\u003e. The sub-GHz signal passes through brick, blockwork, and concrete far more effectively than 2.4 GHz Wi-Fi. Real-world installations consistently achieve reliable readings through multiple floors and thick masonry at typical UK domestic and commercial distances.\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"border:1px solid #dde8e7;border-radius:6px;margin-bottom:8px;\"\u003e\n  \u003csummary style=\"background:#008377;color:#fff;padding:12px 14px;font-weight:600;cursor:pointer;border-radius:5px;font-size:14px;\"\u003eCan this be used to enforce zero export on a G99 connection?\u003c\/summary\u003e\n  \u003cdiv style=\"padding:14px 16px;font-size:14px;line-height:1.7;color:#333;\"\u003eYes. The SUNCT-RS03 feeds the Acure real-time grid current data, which the inverter uses to \u003cstrong\u003ethrottle its AC output and prevent any net export\u003c\/strong\u003e to the grid. This is the standard method for zero-export compliance on G99 connections where the DNO prohibits export or where an export cap is required.\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"border:1px solid #dde8e7;border-radius:6px;margin-bottom:8px;\"\u003e\n  \u003csummary style=\"background:#008377;color:#fff;padding:12px 14px;font-weight:600;cursor:pointer;border-radius:5px;font-size:14px;\"\u003eCan I use this CT and Smartlynk switches on the same inverter?\u003c\/summary\u003e\n  \u003cdiv style=\"padding:14px 16px;font-size:14px;line-height:1.7;color:#333;\"\u003eYes. Both share the Acure's LoRa radio. A single Acure inverter can manage \u003cstrong\u003eup to 2 wireless CTs and up to 10 Smartlynk switches simultaneously\u003c\/strong\u003e, all communicating over the same LoRa network with no conflict or interference.\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sunsynk","offers":[{"title":"Default Title","offer_id":64745856696669,"sku":"SUNCT-RS03","price":107.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SunsynkWirelessCTClampSUNCT-RS03AcureInverter.webp?v=1779271647"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/collections\/EmLiteEMP1ThreePhaseSolarPVImportExportMeter.webp?v=1761580229","url":"https:\/\/qualityheating.co.uk\/collections\/metering.oembed?page=3","provider":"AIZO Quality Heating","version":"1.0","type":"link"}